VIM RESS - RESD - RESF VAV CAV regulated register Installation instructions
PDF
Document
Advertisement
Advertisement
Modbus Interface Description VAV-Compact Volumetric flow compact control device Edition 2023-12 / V3.08 NT00000923-RESS-RESD-MODBUS-REGISTER-VAV-V3-08-AN-231201 Contents Modbus general notes General information Modbus RTU Parametrisation Register implementation 4 Supported commands Command “Read Discrete Inputs” Interpret values in the registers 32-bit values in two registers 5 Operation, Service 6 Modbus register overview Modbus register description 7–9 4 Interface description / VAV-Compact / General notes Modbus general notes General information Date 01.12.2023 Product Name VAV-Compact Actuator Type ..MV-D3-MOD, ..HV24A-MOD Protocol Modbus RTU over RS-485 Transmission Formats Address 1-8-N-2, 1-8-N-1, 1-8-E-1, 1-8-O-1 (Default: 1-8-N-2) 9'600, 19'200, 38'400, 76'800, 115'200 Bd (Default: 38'400 Bd) 1...247 (Default: 1) Number of Nodes Max. 32 (without repeater) Terminating Resistor 120 Ω Parametrisation Tool ZTH EU Quick addressing Actuators support quick addressing via the “Address” and “Adaption” buttons. For detailed information, please see product datasheet (chapter Service). Register implementation All data is arranged in a table and addressed by 1..n (Register No.) or 0..n-1 (Address). No distinction is made between data types (Discrete Inputs, Coils, Input Registers and Holding Registers). As a consequence, all data can be accessed with the two commands for Holding Register. The commands for Discrete Inputs and Input Registers can be used as an alternative. Supported commands Standard commands: Read Holding Registers [3] Write Single Register [6] Command “Read Discrete Inputs” The command reads one or more bits and can alternatively be used for Register No. 105 (Malfunction and Service Information). Modbus RTU Baud Rates Optional commands: Read Discrete Inputs [2] Read Input Registers [4] Write Multiple Registers [16] Example: The start address to be used is 1664 -> 104 (Register Address) * 16 (Bit) = 1664 Interpret values in the registers All values in the register are unsigned integer data types. Example: Read (Function 03, 1 Register) Value Register No. x = 0001 1010 1100 10002 = 6,85610 Actual value = value * scaling factor * unit = 6,856 * 0.01 * unit = 68.56 unit Subject to technical modifications Interface description / VAV-Compact / General notes 32-bit values in two registers Values that exceed 65,535 are stored in two consecutive Registers and have to be interpreted as “little endian” / LSW (Least Significant Word) first. Example: Register No. x (Value LowWord) = 14,55110 = 0011 1000 1101 01112 Value LowWord = 14,551 = 0011 1000 1101 01112 Register No. x + 1 (Value HighWord) = 1910 = 0000 0000 0001 00112 Value HighWord = 19 = 0000 0000 0001 00112 32-bit value = 0000 0000 0001 0011 0011 1000 1101 01112 = 1,259,73510 = 1,259.735 unit Math formula: 32-bit value = (Value HighWord * 65,536) + Value LowWord 32-bit value = (19 * 65,536) + 14,551 = 1,259,735 = 1,259.735 unit Deactivated registers Subject to technical modifications If a register is not supported by a device or by a device setting, this is indicated by 65,535 (1111 1111 1111 11112). 5 6 Interface description / VAV-Compact / Modbus Modbus register overview Operation Service ! Subject to technical modifications No. Address Register Access 1 0 Setpoint [%] R/W 2 1 Override Control R/W 3 2 Command R/W 4 3 Actuator Type R 5 4 Relative Position [%] R 6 5 Absolute Position [°] [mm] R 7 6 Relative Volumetric Flow [%] 8 7 Absolute Volumetric Flow [m /h] R 9 8 Sensor Value 1 [mV] [–] R 10 9 – 11 10 12 11 13 12 No. Address Register Access 100 99 Bus Termination R 101 100 Series Number 1st part 102 101 Series Number 2nd part 103 102 Series Number 4th part 104 103 Firmware Version R 105 104 Malfunction and Service Information R 106 105 Min [%] R 107 106 Max [%] R/W 108 107 Sensor Type 1 R/W 109 108 Bus Fail Position R/W 110 109 Communication Watchdog 111 110 Nominal Volumetric Flow [m /h] – 112 111 – – 113 112 114 113 115 114 – – 116 115 – – 117 116 Control Mode R/W 118 117 Unit Selection Flow R/W 119 118 Setpoint Source R/W R 3 – Absolute Flow in unit selected LowWord HighWord Analog Setpoint [%] R R R R/W 3 Nominal Volumetric Flow in unit selected LowWord HighWord R All writeable registers >100 are persistent and are not supposed to be written on a regular basis. Interface description / VAV-Compact / Modbus Modbus register description No. Address Description Comment Range, enumeration Unit Scaling Access 1 0 Setpoint Setpoint for actuator between 0 and Max (No. 107) 0...10'000 Default: 0 % 0.01 R/W 2 1 Override control Overrides setpoint with defined values. Use of Fast open / Fast close: Fast open and Fast close cycles lead to increased mechanical load. Usage should be limited to certain time-critical events (e.g. frost protection). 0: None 1: Open 2: Close 3: Min 4: Mid 5: Max 6: Fast open 7: Fast close Default: None(0) – – R/W 3 2 Command Initiation of actuator functions for service and test. After command is sent, register returns to None(0). With Reset(4), all alfunction and service information (Register No. 105) can be reset. 0: None 1: Adaption 2: Test 3: Sync 4: Reset Default: None(0) – – R/W 4 3 Actuator type 0: Actuator not connected – 1: Air / water 2: VAV / EPIV 3: Fire 4: Energy Valve 5: 6way EPIV – R 5 4 Relative position 0...10'000 % 0.01 R 6 5 Absolute position The unit depends on the device: [°] for actuators with rotary movement [mm] for actuators with linear movement 0...max angle / stroke ° mm 1 1 R 7 6 Relative volumetric flow Relative volumetric flow of Vn'om 0...10'000 % 0.01 R 8 7 Absolute volumetric flow 0...V'nom m3/h Pa 1 R 9 8 Sensor 1 value Current value of sensor 1, depending on the setting of the Sensor 1 type (Register No. 108) [mV] if Sensor 1 type (Register No. 108) is Active(1) [0 / 1] if Sensor 1 type (Register No. 108) is Switch(4) 0...65'535 mV – 0/1 R 10 9 – – – – – 11 10 Absolute volumetric flow Absolute flow in unit selected (Register No. 118) LowWord Lower 16 bit of 32-bit value 12 11 Absolute volumetric flow Absolute flow in unit selected (Register No. 118) HighWord Upper 16 bit of 32-bit value – UnitSel 0.001 R 13 12 Analog setpoint Shows the setpoint in % if actuator is controlled by analog signal. 0...10'000 % R Subject to technical modifications 0.01 7 8 Interface description / VAV-Compact / Modbus No. Address Description Comment Range, enumeration Unit Scaling Access 100 99 Bus termination Indicates if bus termination (120 Ω) is enabled. Bus termination can be set with the configuration tools. 0: Inactive 1: Active Default: Inactive(0) – – R 101 100 Series number 1st part Each device has an unambiguous series number, which is either impressed on or glued to the housing. The series number consists of 4 segments, although only parts 1, 2 and 4 are displayed on Modbus. – – – R Example: 00839-31324-064-008 1st part: 00839 2nd part: 31324 4th part: 008 102 101 Series number 2 nd part – – – R 103 102 Series number 4 part – – – R 104 103 Firmware version Firmware version of communication module – – – R Bitmask = – – R th Example: 302, Version 3.02 105 104 Malfunction and service information Value is bit-coded. More than one bit can be set to 1. Not all bits mentioned in the enumeration are used for this actuator range. 1: M echanical travel increased: The actuator has been moved outside the adapted working range. 2: A ctuator cannot move: Mechanical overload, e.g. blocked actuator, etc. 8: Internal activity: Actuator performs a test run, adaptation, etc. 9: Gear train disengaged: The manual override button is pressed. 10: Bus Watchdog triggered: Timeout for the Bus Watchdog expired. Bit0: – Bit1: Mechanical travel increased Bit2: Actuator cannot move Bit3: – Bit4: – Bit5: – Bit6: – Bit7: – Bit8: Internal activity Bit9: Gear train disengaged Bit10: Bus Watchdog triggered Bit11: – Bit12: – Bit13: – Bit14: – Bit15: – 106 105 Vmin Min has to be ≤ Max 0...Vmax Default: 0 % 0.01 R/W 107 106 Vmax Max has to be ≥ Min and >20% Vmin...10'000 Default: 10'000 % 0.01 R/W 108 107 Sensor 1 type If Setpoint Source (Register No. 119) is Analog (hybrid mode), the sensor type 1 can be set to Active(1) in order to see the Analog Setpoint in mV. Note: After changing the sensor type, it might be necessary to restart the actuator in order for correct sensor values to be read out. For setting “4: Switch” it is mandatory that the control signal is parametrised to 2...10 V. 0: None 1: Active / hybrid 2: – 3: – 4: Switch Default: None(0) – – R/W Subject to technical modifications Interface description / VAV-Compact / Modbus No. Address Description Comment Unit Scaling Access 109 108 Bus fail position 0: None / last setpoint Modbus communication is not monitored by default. 1: Fast close In the event of a breakdown in communication, the 2: Fast open actuator retains the current setpoint. 3: Mid position (parametrised) The bus implementation tracks the Modbus Default: None(0) communication. If neither the Setpoint (Register No. 1) nor the Override Control (Register No. 2) is renewed before the timout for Bus Watchdog (Register No. 110) expires, the actuator moves to the Bus Fail Position. Triggered bus watchdog is indicated in the Malfunction and Service Information (Register No. 105). In hybrid mode (SpSource (Register No. 119) = Analog), bus monitoring is not activated. – – R/W 110 109 Timeout for bus watchdog in s Time until Bus Fail will be detected. If Bus Watchdog = 0 then deactivated If Bus Fail Position (Register No. 109) different from 0, the Bus Fail Position becomes active after the Timeout for Bus Watchdog has expired. 0...3'600 s Default: 0 If Bus Fail Position (Register No. 109) not None(0), then Default: 120 1 R/W 111 110 Nominal volumetric flow – m3/h 1 R 112 111 – – – – – 113 112 Nominal volumetric flow Vnom in unit selected (Register No. 118) LowWord Lower 16 bit of 32-bit value – UnitSel 0.001 R 114 113 Nominal volumetric flow Vnom in unit selected (Register No. 118) HighWord Upper 16 bit of 32-bit value 115 114 – – – – – 116 115 – – – – – 117 116 Control mode 0: Position control 1: Flow control – – R/W 118 117 Unit selection flow 0: m3/s 1: m3/h 2: l/s 3: l/min – – R/W 119 118 Setpoint source Analog: Setpoint from analog signal 0...10 V on wire 3. Bus: Setpoint from Modbus (Register No. 1). 0: Analog 1: Bus Default: Bus(1) – – R/W Description Access: R = Read, W = Write Subject to technical modifications Range, enumeration 4: l/h 5: gpm 6: cfm Default: m3/h(1) 9 All inclusive. Belimo as a global market leader develops innovative solutions for the controlling of heating, ventilation and air-conditioning systems. Damper actuators, control valves, sensors and meters represent our core business. Always focusing on customer value, we deliver more than only products. We offer you the complete product range for the regulation and control of HVAC systems from a single source. At the same time, we rely on tested Swiss quality with a five-year warranty. Our worldwide representatives in over 80 countries guarantee short delivery times and comprehensive support through the entire product life. Belimo does indeed include everything. The “small” Belimo devices have a big impact on comfort, energy efficiency, safety, installation and maintenance. 5-year warranty On site around the globe Complete product range Tested quality Short delivery times In short: Small devices, big impact. EN – 2023-12/A – Subject to technical modifications Comprehensive support BELIMO Automation AG Brunnenbachstrasse 1, 8340 Hinwil, Switzerland +41 43 843 61 11, [email protected], www.belimo.com ">
/
Download
Just a friendly reminder. You can view the document right here. But most importantly, our AI has already read it. It can explain complex things in simple terms, answer your questions in any language, and help you quickly navigate even the longest or most compilcated documents.
Advertisement