Intermec JANUS JG2020 User manual

Add to My manuals
119 Pages

advertisement

Intermec JANUS JG2020 User manual | Manualzz
User’s Manual
P/N 064673-004
JANUS 2.4 GHz
Installation Utility (4MB)
®
Intermec Technologies Corporation
6001 36th Avenue West
P.O. Box 4280
Everett, WA 98203-9280
U.S. service and technical support: 1-800-755-5505
U.S. media supplies ordering information: 1-800-227-9947
Canadian service and technical support: 1-800-688-7043
Canadian media supplies ordering information: 1-800-268-6936
Outside U.S. and Canada: Contact your local Intermec service supplier.
The information contained herein is proprietary and is provided solely for the purpose of allowing
customers to operate and/or service Intermec manufactured equipment and is not to be released,
reproduced, or used for any other purpose without written permission of Intermec.
Information and specifications in this manual are subject to change without notice.
 1998 by Intermec Technologies Corporation
All Rights Reserved
The word Intermec, the Intermec logo, JANUS, IRL, TRAKKER, Antares, Duratherm, Precision Print,
PrintSet, Virtual Wedge, and CrossBar are either trademarks or registered trademarks of Intermec
Corporation.
Throughout this manual, trademarked names may be used. Rather than put a trademark () symbol
in every occurrence of a trademarked name, we state that we are using the names only in an
editorial fashion, and to the benefit of the trademark owner, with no intention of infringement.
Manual Change Record
This page records the changes to this manual, which was originally released as version 001.
Version
Date
Description of Change
002
12/96
New information was added for the JG2050 and for UDP Plus
terminal emulation.
003
9/97
New information was added to describe using the installation utility
on a JG2010.
004
7/98
Installation utility software was modified to streamline the
installation/configuration process.
Contents
Contents
Before You Begin ix
Cautions and Notes ix
About This Manual ix
Other Related Manuals xii
1
Learning About the Installation Utility
Unpacking the Installation Utility Kit 1-3
What the Installation Utility Does 1-3
How the Installation Utility Works 1-4
Modifying the JANUS Drive Images 1-5
Drive C Image 1-5
Drive D Image 1-5
Downloading the New JANUS Drive Images 1-6
System Requirements 1-7
Host PC Requirements 1-7
Making a Backup Copy 1-7
Navigating Within Screens 1-8
2
Preparing to Run the Installation Utility
Why Read This Chapter? 2-3
Setting Up the Host PC 2-3
Creating a HOSTS File 2-3
Understanding Configuration Parameters 2-4
Terminal Selection Screen 2-4
Network/Protocol Selection Screen 2-4
Character Set Screen 2-5
About the Network Parameters 2-6
LAN WorkPlace for DOS Parameters 2-7
NetWare Client for DOS Parameters 2-8
FTP PC/TCP for DOS Parameters 2-9
About the Radio Parameters 2-10
v
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
Shelling Out to DOS 2-12
Configuring Multiple JANUS RF Devices 2-13
3
Running the Installation Utility
Starting the Installation Utility 3-3
Configuring the First JANUS RF Device 3-3
Choosing the Configuration Parameters 3-3
Shelling Out to DOS to Modify the JANUS Drive Images 3-7
Downloading the Modified JANUS Drive Images 3-8
Configuring Multiple JANUS RF Devices 3-10
Restoring the Host PC to the Original Configuration 3-11
4
Troubleshooting
General Problems 4-3
Error Messages 4-4
Drive A Error Messages 4-8
A
Deleted, Modified, and New Files
Deleted Files A-3
Files Removed From Drive C A-3
Files Removed From Drive D A-3
Modified CONFIG.SYS File A-4
JG2010 CONFIG.SYS A-4
JG2020 CONFIG.SYS A-6
JG2050 CONFIG.SYS A-8
Modified AUTOEXEC.BAT File A-10
JG2010 AUTOEXEC.BAT A-10
JG2020 AUTOEXEC.BAT A-12
JG2050 AUTOEXEC.BAT A-14
NET.CFG File A-16
JG2010 NET.CFG A-16
JG2020 NET.CFG A-17
vi
Contents
JG2050 NET.CFG A-18
About the NET.CFG Parameters A-20
PCTCP.INI File A-20
NET.BAT File A-22
JG2010 NET.BAT for NetWare Client A-22
JG2010 NET.BAT for LanWorkplace A-22
JG2010 NET.BAT for FTP Application A-23
JG2020 NET.BAT for NetWare Client A-23
JG2020 NET.BAT for LAN WorkPlace A-24
JG2020 NET.BAT for FTP Application A-24
JG2050 NET.BAT for NetWare Client A-25
JG2050 NET.BAT for LAN WorkPlace A-25
JG2050 NET.BAT for FTP Application A-26
About the NET.BAT Parameters A-26
Other Useful Files A-27
APP.BAT for LAN WorkPlace for DOS A-27
APP.BAT for NetWare Client for DOS A-27
APP.BAT for FTP Application A-27
GO.BAT for LAN WorkPlace for DOS and FTP Application A-28
GO.BAT for NetWare Client for DOS A-28
UNNET.BAT for LAN WorkPlace for DOS A-28
UNNET.BAT for NetWare Client for DOS A-28
UNNET.BAT for FTP Application A-29
IMLOGIN.BAT A-29
IMLOGOUT.BAT A-29
UDPPLUS.INI A-29
Minimum Files for LAN WorkPlace Installations A-30
B
Helpful Information
NetWare Client User Information B-3
ARP Table Entry for TCP/IP Applications B-3
Setting the Security ID on Your JANUS RF Devices B-5
Customizing the J24TE.INI File B-10
Creating a JANUS.INI File B-11
Configuring Multiple JANUS RF Devices Using Batch Files B-13
vii
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
G
I
viii
Glossary
Index
Before You Begin
Before You Begin
This section introduces you to cautions, document formatting conventions, and
sources of additional product information.
Cautions and Notes
The cautions and notes in this manual use the following format.
CAUTION
Caution
A caution alerts you to an operating procedure, practice, condition, or
statement that must be strictly observed to prevent equipment damage or
destruction, or corruption or loss of data.
Conseil
Une précaution vous avertit d’une procédure de fonctionnement, d’une
méthode, d’un état ou d’un rapport qui doit être strictement respecté pour
empêcher l’endommagement ou la destruction de l’équipement, ou l’altération
ou la perte de données.
Note: Notes either provide extra information about a topic or contain special
instructions for handling a particular condition or set of circumstances.
About This Manual
This manual provides you with information on the features of the JANUS 2.4
GHz Installation Utility, how to use it, how to configure it, and what the error
messages mean. To run this Installation Utility, you must be familiar with your
host PC, JANUS RF devices, and your network.
ix
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
What You Will Find in This Manual
This table summarizes the information in each chapter of this manual:
For Information On
Refer To
Understanding the
Installation Utility
Chapter 1, “Learning About the Installation Utility.”
Explains the Installation Utility features and how it
works. This chapter also provides system and host
PC requirements.
Information you need to
gather before running the
Installation Utility
Chapter 2, “Preparing to Run the Installation
Utility.” Explains the network and radio parameters.
Running the Installation
Utility
Chapter 3, “Running the Installation Utility.”
Explains how to run the Installation Utility.
Troubleshooting information
Chapter 4, “Troubleshooting.” Provides solutions to
problems you may encounter while running the
Installation Utility.
Which files are deleted,
modified, and created
Appendix A, “Deleted, Modified, and New Files.”
Provides printouts of the modified CONFIG.SYS and
AUTOEXEC.BAT files and the new NET.CFG,
NET.BAT, APP.BAT, GO.BAT, PCTCP.INI, and
UNNET.BAT files.
Special Information
Appendix B, “Helpful Information.” Provides
helpful information you may need when running the
Installation Utility.
In addition, this manual contains a glossary and an index.
x
Before You Begin
Format Conventions for Input From a Keyboard or Keypad
This table describes the formatting conventions for input from host PC
keyboards and JANUS keypads:
Convention
How to Interpret the Convention
Special text
Shows the command as you should enter it into the device. See
“Format Conventions for Commands” later in this section.
Italic text
Indicates that you must replace the parameter with a value. See
“Format Conventions for Commands” later in this section.
Bold text
Indicates the keys you must press on a PC or host computer
keyboard. For example, “press Enter” means you press the key
labeled “Enter” on the PC or host computer keyboard.
@
><A
A<
–
@
Shows the key you must press on the device. For example,
“press
” directs you to press the key labeled “Enter” on the
device keypad.
><A
Shows a series of device keys you must press and release in the
order shown. For example, “Press
to boot the
device.”
Shows a series of device keys you must press simultaneously.
Also, you must press and hold the keys in the order shown. For
example, “Press
– to enter Control mode.”
A<
Format Conventions for Commands
This manual includes sample commands that are shown exactly as you should
type them on your device. The manual also describes the syntax for many
commands, defining each parameter in the command. This example illustrates
the format conventions used for commands:
When you use the LOADADD command, follow this syntax:
loadadd [path\]filename [path\filename path\filename...]
where:
path
is the drive and directory of the file(s) to include in the image file.
If you do not include a path, the current directory is used.
filename
is the name of the file or files to include in the image file and load
to the device.
You can include multiple path\filename and path\*.* parameters in the
command. The path\*.* parameter loads all the files in a directory. For example,
type this command at the DOS prompt and press
:
@
loadadd c:\janus\config.sys c:\atadrv\*.* c:\data\*.*
xi
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
This table defines the conventions used in the example:
Convention
Description
Special text
Commands appear in this font. You enter the command exactly
as it is shown.
Italic text
Italics indicate a variable, which you must replace with a real
value, such as a number, filename, or keyword.
[]
Brackets enclose a parameter that you may omit from the
command. Do not include the brackets in the command.
Required
parameters
If a parameter is not enclosed in brackets [ ], the parameter is
required. You must include the parameter in the command;
otherwise, the command will not execute correctly.
where
This word introduces a list of the command’s parameters and
explains the values you can specify for them.
Other Related Manuals
You may need additional information when working with JANUS devices in a
data collection system. Please visit our web site at www.intermec.com for a list
of available manuals or to access many of our current manuals in PDF format.
To order printed versions of the Intermec manuals, contact your local Intermec
representative or distributor.
xii
1
Learning About the Installation Utility
Learning About the Installation Utility
1
This chapter introduces you to the JANUS 2.4 GHz Installation Utility and describes
how it works with JANUS RF devices and your host PC. It also explains the contents of
the installation kit and defines the system requirements.
Unpacking the Installation Utility Kit
When you receive your JANUS 2.4 GHz Installation Utility kit, you need to
verify the contents of the kit. Each kit comes with:
•
Installation Utility disk
•
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
•
JANUS 2.4 GHz terminal emulation application disk
•
JANUS 2.4 GHz terminal emulation for Model 200 Controller application
disk
•
JANUS 2.4 GHz Terminal Emulation Quick Reference Guide
•
Security ID Configuration disk
•
JANUS 2010 (4MB) companion disks (3 disks)
•
JANUS 2020 (4MB) companion disks (3 disks)
•
JANUS 2050 (4MB) companion disks (3 disks)
The Installation Utility disk contains a README file that provides additional
information that became available after the printing of this manual.
Note: Contact your Intermec sales representative to order the FTPPC/TCP Stack Disk
(P/N 067791).
What the Installation Utility Does
The JANUS 2.4 GHz Installation Utility configures JANUS RF devices to work
in an Intermec 2.4 GHz RF network. The Installation Utility creates drive
images for the devices that include the network software that allows these
devices to connect with a Novell network or a TCP/IP-based network. The
Installation Utility runs on a host PC in the DOS environment or a DOS
window and uses a DOS text-based interface to prompt you for client network
and radio operating parameters.
The Installation Utility:
•
Allows you to easily configure your JANUS device. All you have to do is fill
in the fields and follow the instructions on your screen.
•
Verifies that your host PC has the necessary files, memory, and hard disk
space to ensure successful installation.
1-3
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
•
Frees enough space on the JANUS device to install the network software.
The Installation Utility deletes the IRL Desktop, the Intermec 900 MHz RF
Protocol Handler, and some DOS utilities.
•
Provides a shell out option before the drive images are built to allow you to
change the contents of the drive images, add a security ID, modify JANUS
configuration parameters, or perform any other DOS command.
•
Saves time when configuring multiple JANUS RF devices by retaining the
drive C and drive D images from the first device.
In a typical Intermec 2.4 GHz RF network, the JANUS RF devices communicate
with the access points, wireless to wired bridges, that pass the packets through
Ethernet on to the host.
A Typical Intermec 2.4 GHz RF Network
Host
JANUS
Devices
Access
Point
Ethernet
JANUSQ.001
How the Installation Utility Works
This section provides you with an overview of how the Installation Utility
works.
1. JANUS drive images are extracted from the companion disks.
2. Selected JANUS files are removed from the drive C and drive D
subdirectories to create space for the network software and radio drivers.
•
Network software, radio drivers, configuration files, and optional
terminal emulation software are added.
•
Data collection applications can be added.
3. New JANUS drive C and drive D images are downloaded to the connected
JANUS device.
1-4
Learning About the Installation Utility
1
Note: After you configure the first JANUS device, additional devices may be
programmed using most of the data you entered on the first installation. The
Installation Utility provides the option for multiple installations, allowing you to
change the data you entered on the first installation. The Installation Utility then
rebuilds the applicable images for downloading to the next device.
Modifying the JANUS Drive Images
The Installation Utility gives you a chance to modify the contents of drives C
and D before the drive images are built. When running the Installation Utility, a
message box appears asking if you want to shell out to the DOS command line.
Using DOS commands or a DOS file editor, you can add, delete, or change files.
Drive C Image
The scratch drive (\IM_FLASH\DRIVEC) is where the drive C image is built
that is downloaded to the JANUS RF device. In this directory, the Installation
Utility removes files that are not needed for the JANUS device to operate in an
Intermec 2.4 GHz RF network.
The list of files that are going to be deleted are in \IM_FLASH\DRIVECX. If
there is a file that you do not want the Installation Utility to delete in the
DRIVECX subdirectory, copy the file back to \IM_FLASH\DRIVEC. If you add
too many files to the subdirectory and it does not have enough free disk space
to load the network software, an error message will appear. Choose files in
DRIVEC to delete to create the necessary free disk space.
See Appendix A for a complete list of the files that are deleted to create the
necessary free space.
Drive D Image
The scratch drive (\IM_FLASH\DRIVED) is where the drive D image is built
that is downloaded to the JANUS RF device. In this directory, the Installation
Utility creates the necessary disk space for the Novell network software by
deleting unnecessary JANUS files. See Appendix A for a complete list of the
files that are deleted to create the necessary free space.
The Installation Utility copies the Novell network subdirectory structure from
the installation directory to the DRIVED directory.
•
If you are installing NetWare Client for DOS, the JANUS drive D network
subdirectory structure looks like:
D:\NWCLIENT
|_ NLS
|_ ENGLISH
1-5
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
•
If you are installing LAN WorkPlace for DOS, or PC/TCP for DOS, the
JANUS drive D network subdirectory structure looks like:
D:\NET
|_ BIN
|_ HSTACC
|_ PROFILE
|_ DRIVERS
|_ SCRIPT
|_ TCP
|_ LANG
See Appendix A for a list of the minimum required files for a LAN
WorkPlace installation.
This list of files that are going to be deleted are in \IM_FLASH\DRIVEDX.
Default drive D files are copied to \IM_FLASH\DRIVED. If there is a file that
you do not want to delete in DRIVEDX, you need to copy it back to the
DRIVED directory and choose another file in the DRIVED directory to delete so
you can create the necessary free disk space.
The Installation Utility also copies special drivers from the program disk to the
RAM drive directory. These drivers are:
•
RL2OEM.COM, the radio driver
•
MINIPM.EXE, the radio power management driver
Downloading the New JANUS Drive Images
The Installation Utility makes a new drive C image from the files in
\IM_FLASH\DRIVEC. It makes a new drive D image from the files in
\IM_FLASH\DRIVED. It then downloads these new drive images to the
JANUS RF device.
The Installation Utility asks you if you want to perform another installation on
another device. You can save time by configuring all the devices in your
network at the same time. For each subsequent device you configure, the
Installation Utility does not download and then upload the drive C and D
images again.
When you finish running the Installation Utility, a message box appears asking
you if you want to discard the files that it generated. You can save the files for
future reference or you can discard the files.
1-6
Learning About the Installation Utility
1
System Requirements
You must have the following hardware/software components and network
information before installing your data collection network.
•
JANUS 2.4 GHz RF devices
•
JANUS 2.4 GHz Installation Utility kit
•
Optical adapter or communications dock (JG2010 or JG2020)
•
Null modem cable
•
Access points
•
IP addresses for each device, the default router address, and the subnet
mask, if this information will not be obtained from a BOOTP or RARP
server at boot time.
Host PC Requirements
You can use any type of PC (desktop, laptop, or notebook) as your host PC if it
meets the following minimum system requirements:
•
Hard disk with at least 14MB of disk space available
•
3.5-inch high-density drive A
•
Serial port
•
PC-DOS or MS-DOS v5.0 or above, Windows 3.1 (DOS prompt), or
Windows 95 (DOS prompt)
Making a Backup Copy
Intermec recommends that you make a backup copy of all the disks that ship in
your original JANUS 2.4 GHz Installation Utility kit. Place the original disks in
a safe place. Run the Installation Utility using the backup copy. You need to
provide:
•
3.5-inch, high-density, formatted disks
To make a backup copy
1. Insert the disk in drive A of your host PC.
2. From a DOS prompt, type:
diskcopy a: a:
3. Follow the instructions on the screen to make your backup copy.
1-7
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
Navigating Within Screens
You can navigate the screens in the Installation Utility in several ways. You can
use many of the same conventions that you know from other software
programs. When you open a screen, there may already be values in some of the
fields. For toggle fields, use the spacebar to switch between options.
Press the F1 key on your host PC to view the navigation help screen. This
screen appears:
1-8
2
Preparing to Run the Installation Utility
Preparing to Run the Installation Utility
2
This chapter tells you what information you need to obtain before running the
Installation Utility. It also helps you understand the parameters.
Why Read This Chapter?
Running the Installation Utility, it can take up to 10 minutes to configure your
first JANUS RF device depending on the baud rate you use for data
transmission. Once you start running the Installation Utility, you must either
complete the entire procedure to configure the first JANUS RF device or
abandon the procedure and start over again. You cannot stop and then restart
the process in the middle. Completing the installation tasks will be easier if you
understand this chapter and have the correct configuration parameter
information before you start.
Setting Up the Host PC
You can use any type of PC as your host PC as long as it meets the minimum
system requirements listed in “Host PC Requirements” in Chapter 1.
Creating a HOSTS File
If you are using Intermec or Novell terminal emulation (LAN WorkPlace for
DOS), you can create a HOSTS file in the directory \NET\TCP on the host PC.
The Installation Utility will download the HOSTS file to the JANUS RF device.
The HOSTS file is a hostname database that contains a list of the remote hosts
that you can reach. Each line contains the host IP address and its aliases. For
example:
192.9.175.274 host1
192.9.175.13 sunhost1
This ASCII text file must be less than 50K or it will not fit on the JANUS device.
50K is enough space to support a large network, most data collection networks
will require a much smaller file. If you choose not to create a HOSTS file, this
non-fatal diagnostic message appears during the installation.
Warning, HOSTS Too Large or Not Found, Continue?
Refer to your network documentation for help on creating and interpreting
HOSTS files.
2-3
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
Understanding Configuration Parameters
Use the following configuration parameter definitions when you fill in fields on
the terminal selection, character set, network, and radio parameters screens.
Terminal Selection Screen
Use the Choose a Device to Configure screen to specify the type of JANUS
device that you want to configure.
Network/Protocol Selection Screen
If your JANUS device is going to emulate a terminal, use the Select a
Network/Protocol screen to specify the terminal type. The Installation Utility
will load the appropriate terminal emulation application. Refer to the JANUS
2.4 GHz Terminal Emulation Quick Reference Guide for information about using
Intermec terminal emulation software.
Note: If you configure your JANUS device to run terminal emulation software, a
terminal emulation session will start after you complete the installation and reboot the
device. If you do not want the terminal session to start, you need to modify your
APP.BAT file or you can add a REM before the statement in the AUTOEXEC.BAT file
that calls the APP.BAT file.
Intermec TNVTxxx Emulation This Intermec software allows your device to
emulate a VT120/220/320 or ANSI terminal using a telnet session.
2-4
Preparing to Run the Installation Utility
2
Intermec 3270 or 5250 Emulation This Intermec software allows your device to
emulate an IBM 3270 or 5250 terminal using a telnet session.
Note: The UDP+ option is for communication with the Model 200 Controller.
Novell TNVTxxx Emulation Select this option to configure your JANUS device to
emulate a VT120/220/320 or ANSI terminal using a telnet session. You may
also need to load an application when running this emulation.
NetWare Client for DOS This Novell software allows your device to run your
applications using SPX/IPX protocol.
FTP PC/TCP Stack This TCP/IP stack allows your JANUS device to run
applications using the PC/TCP stack from FTP Corporation.
Note: To install the FTP PC/TCP stack you will need to purchase the FTP PC/TCP
Stack Disk (P/N 067791). See your Intermec sales representative to order the FTP disk.
Character Set Screen
The Choose a Character Set selection screen configures your JANUS RF device
for the selected character set.
The Installation Utility supports international character sets for France,
Germany, Italy, and Spain. The default BIOS keyboard driver supports the U.S.
character set. An international character set allows DOS to display date and
time prompts, currency symbols, date separators, time separators, and decimal
separators in the standard format of the chosen country. The international
character set drivers do not translate DOS message text.
If you select a non-U.S. character set, these actions are performed when the
CONFIG.SYS file is processed:
•
The COUNTRY configuration command is executed, which customizes
country-dependent information (such as date and time formats, currency
symbols, collating sequences, etc.) for a particular country.
•
The DISPLAY.SYS device driver is loaded to support code page (character
set) switching for the console device (LCD).
2-5
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
If you select a non-U.S. character set, these actions are performed when the
AUTOEXEC.BAT file is processed:
•
The appropriate code page is selected.
•
The appropriate code page is prepared.
•
The KEYB.COM program is loaded to replace the current keyboard driver.
Switching Between Keypads
Use the following commands to switch between keypad configurations on your
JANUS RF device.
•
•
> < G to switch to the U.S. keypad.
> < H to switch to the keypad driver installed for the country you
selected.
Conventional Memory Required
Configuring for international character sets requires an additional 17K to 35K
of conventional memory on your JANUS device.
About the Network Parameters
Use the Installation Options screens to enter the network parameters for FTP
PC/TCP for DOS, NetWare Client for DOS or LAN WorkPlace for DOS and the
radio parameters. At this point, the utility checks to make sure that you have at
least 14MB of hard disk space available on your host PC.
The Installation Options screen that appears depends on which terminal
software option you chose in the Terminal Selection screen.
2-6
•
LAN WorkPlace for DOS. This screen appears if you choose to load
software that uses TCP/IP (Intermec TNVTxxx, 3270 or 5250, or Novell
TNVTxxx).
•
NetWare Client for DOS. This screen appears if you choose to load software
that uses SPX/IPX (NetWare Client).
•
FTP PC/TCP for DOS. This screen appears if you choose to load software
that uses PC/TCP for DOS.
Preparing to Run the Installation Utility
2
LAN WorkPlace for DOS Parameters
Field
Description
Version
Choose the version of LAN WorkPlace for DOS you
are installing (4.2, 5.0, or provided).
Path to LAN WorkPlace
Installation
Enter the location (drive:\pathname) of LAN
WorkPlace for DOS on your host PC (for version 4.2
or 5.0).
Drive that will be used to
build new flash images
Enter the hard drive (or partition) on your host PC
that you want to use as a scratch drive to build the
JANUS drive images. 14MB is required.
Station IP Address
Enter the JANUS device IP address.
Unix User Name
Enter a valid user name for the UNIX environment.
Subnet Mask
The Installation Utility enters the first part of the
subnet mask based on the Station IP address. Enter
the last part of the subnet mask.
Default Router
The Installation Utility enters the first part of the
default router address based on the Station IP
address. Enter the last part of the default router
address.
Host IP Address or Host
Name.
The Installation Utility enters the first part of the
host IP address based on the Station IP address.
Enter the last part of the host IP address or enter a
host name.
0200 Controller IP Address
(UDP Plus only) Enter the IP address of the Model
200 Controller that you plan to communicate with.
2-7
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
NetWare Client for DOS Parameters
2-8
Field
Description
Version
(3.12, 4.x) Choose the version of NetWare Client for
DOS you are installing.
Path to NetWare Client
Installation
Enter the location (drive:\pathname) of NetWare
Client for DOS files on your host PC.
Drive that will be used to
build new flash images
Enter the hard drive (or partition) on your host PC
that you want to use as a scratch drive to build the
JANUS drive images. It must have at least 14MB
free.
Novell User Name
(Optional) Enter the user’s login name that will be
used to log in to the network.
Novell Server Name
(Optional) Enter the server name to which the
JANUS device will connect.
Bindery Emulation
(Optional) Choose Yes to enable bindery emulation.
Preferred Tree
(v4.x only) Enter the preferred tree.
Name Context
See your Novell NetWare Client documentation.
Preparing to Run the Installation Utility
2
FTP PC/TCP for DOS Parameters
Field
Description
Path to Network Installation
Enter the location (drive:\pathname) of FTP PC/TCP
files on your host PC.
Temporary drive for flash
images
Enter the hard drive (or partition) on your host PC
that you want to use as a scratch drive to build the
JANUS drive images. It must have at least 14MB
free.
Install Novell compatibility
shim
(Optional) Installing the Novell compatibility shim
allows you to run applications written for the Novell
stack to run on top of the FTP stack.
Station IP Address
Enter the JANUS device IP address.
Subnet Mask
The Installation Utility enters the first part of the
subnet mask based on the Station IP address. Enter
the last part of the subnet mask.
Default Router
The Installation Utility enters the first part of the
default router address based on the Station IP
address. Enter the last part of the default router
address.
2-9
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
About the Radio Parameters
Use the Radio Parameters screen to configure the parameters that are required
for your JANUS RF device to communicate with access points. All devices in
the same subnetwork must have the same domain and the same security ID.
Security IDs are optional. Use different domains on devices if they are in the
same area and you want the devices to communicate to different hosts.
Each domain (subnetwork), must have one acting master to coordinate
communications from the various stations. For most network operating
systems, the access point is the master. If the master unit is turned off or is out
of range, then one of the other access points configured as an alternate master
becomes the master. For most network operating systems, the JANUS RF
devices are stations.
If the inactivity settings are exceeded and your radio is placed into Sleep mode,
you can wake up the radio by either answering yes to the Wake Up on
Broadcast parameter, or you can physically suspend and resume the JANUS RF
device (press the
button twice) when the device is running.
L
Note: Intermec recommends that you keep the default settings for Inactivity Minutes
and Inactivity Seconds. The default setting ensures that you will receive optimum
battery life on JANUS devices with removable batteries.
2-10
Preparing to Run the Installation Utility
2
Radio Parameters Screen Field Descriptions
Field
Description
Station Type
You can choose master, alternate master, or station as your
station type. The default is station.
Alternate masters act either as a master or a station. If an
alternate master unit is unable to locate any other master within
range, it acts as a master. If a master station is already present,
then the alternate master acts as a station.
Master Name
Masters and alternate masters. This optional parameter can be
up to 11 alphanumeric characters. Each master name specifies a
name that simplifies the identification of each master in your
network.
Channel
Masters and alternate masters. Enter the channel (1 to 15)
through which the master communicates with its stations.
For each domain (subnetwork), select a different channel for
each master to communicate with all the stations. The channels
are 1 to 15. The default is 1.
Each channel separates communications for each subnetwork to
allow for a higher data rate transmission capability in the same
airspace. Each channel provides 1.6 Mbps, for a maximum total
bandwidth of 24 Mbps in a particular area.
Subchannel
Masters only. Enter the subchannel (1 to 15) through which the
master communicates with its stations.
If you have more than 15 masters in the same area, change the
subchannel to a different value to separate the various
networks. The subchannels are designated 1 to 15. The default
is 1.
Domain
Enter the domain (0 to 15) of the subnetwork.
If you want stations to be able to roam between masters in a
subnetwork, all station types (master, alternate master, station)
require the same domain number. The domain is a number
from 0 to 15. The default is 0.
Inactivity Minutes
This parameter, with inactivity seconds, defines the length of
time that the device stays on when there is no activity. If this
time is exceeded, the radio is placed in a Sleep mode. The
maximum amount of inactivity time you can set is 21 minutes,
15 seconds. The default and recommended setting is 0.
2-11
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
Field
Description
Inactivity Seconds
This parameter, with inactivity minutes, defines the length of
time that the device stays on when there is no activity. If this
time is exceeded, the radio is placed in a Sleep mode. Inactivity
seconds can be from 0 to 60, in multiples of 5. The default and
recommended setting is 5, which means that the radio will
enter the Sleep mode after five seconds of inactivity.
If you specify a number of seconds greater than 0, but less than
5, this parameter will automatically jump to 5 seconds.
Wakeup on
Broadcast
Choose Yes if you want the radio to wake up and receive a
broadcast packet when it is sent through the network. The
default is No.
After you JANUS radio enters Sleep mode, it enters a Standby mode where the
clock power is lessened to save power. Also, you may want to use the
automatic shutoff feature on your JANUS RF device to save power. The
automatic shutoff command defines the length of time of inactivity on the
JANUS device before it enters Suspend mode.
Shelling Out to DOS
When the Installation Utility has uploaded the JANUS images to the host PC,
you can shell out to DOS if you need to perform any of these tasks.
•
Create a custom JANUS.INI file. If you are installing Novell TNVTxxx or
NetWare Client for DOS on your JANUS device you need to create this file.
For help, see “Creating a JANUS.INI File” in Appendix B.
•
Modify the J24TE.INI file. If you are installing Intermec terminal emulation
on your JANUS device you may want to customize this file to permanently
change your JANUS operating environment. For help, see “Customizing the
J24TE.INI File” in Appendix B.
•
Add your data collection application.
Note: Intermec recommends that you do not run any other applications, such as
Windows, from the DOS command line. Only use the DOS file editor or DOS
commands to edit the files or directories.
If the files you want to copy to drive C exceed the capacity of the drive, the
following messages appear when you type exit at the DOS prompt.
2-12
Preparing to Run the Installation Utility
2
Do you want to shell out to DOS and reduce number of files? (Y/N)
To correct this problem, choose Y to shell out to DOS. Delete files from
\IM_FLASH\DRIVEC. This message will keep repeating each time you type
exit until you create enough free disk space for the drive C image.
Configuring Multiple JANUS RF Devices
After the Installation Utility has configured your first JANUS device, a message
box asks you if you want to do another installation.
At this point, you can:
•
Configure another JANUS RF device.
•
Save your drive images so that you can configure another JANUS device
later.
Intermec recommends that you test the device before you exit the Installation
Utility or before you configure other JANUS RF devices. If the device is not
configured correctly, proceed with another installation and change the
parameter that is causing the failure (for example, incorrect domain, IP address,
etc.).
If you choose to configure another JANUS device, a message box asks you to
confirm the type of installation you want to perform. If you choose Y, the
Installation Options screen appears again. You are not be able to change the
options in the first four fields. During the same installation, each device must
be configured for the same network software, version, path, and flash image
drive. Depending on your network software, you can change the following
parameters:
2-13
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
If you are installing
You can change
NetWare Client for DOS
Novell User Name
Novell Server Name
Bindery Emulation
Preferred Tree
Name Context
For an explanation of these parameters,
refer to “NetWare Client for DOS
Parameters” earlier in this chapter.
LAN WorkPlace for DOS
•
•
•
•
Intermec TNVTxxx Emulation
Intermec 3270 Emulation
Intermec 5250 Emulation
Novell TNVTxxx Emulation
FTP PC/TCP
Station IP Address
Unix User Name
Subnet Mask
Default Router
Host IP Address or Host Name
For an explanation of these parameters,
refer to “LAN WorkPlace for DOS
Parameters” earlier in this chapter.
Station IP Address
Subnet Mask
Default Router
If you press N, you can change the type of terminal emulation software that
you want to install before going to the Installation Options screen. If you
change the terminal emulation, you will need to insert the TE Applications disk
so the Installation Utility can get the necessary terminal emulation software.
2-14
3
Running the Installation Utility
Running the Installation Utility
3
This chapter explains how to use the Installation Utility to configure one or more
JANUS RF devices. For more detailed information about these procedures, see
Chapter 2, “Preparing to Run the Installation Utility.”
Starting the Installation Utility
•
At the DOS prompt of your host PC, type this command and press Enter.
a:install
Configuring the First JANUS RF Device
For help understanding any of the processes or parameters, see Chapter 2,
“Preparing to Run the Installation Utility.”
Choosing the Configuration Parameters
1. The Choose a Device to Configure screen is the first to appear. Use the
arrow key to select the type of JANUS RF device that is connected to your
host PC and press Enter.
2. The Select a Network/Protocol screen appears. Use the arrow key to select
the type of software that you want to install on the device and press Enter.
3-3
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
3. The Choose a Character Set screen appears for TNVT and Netware Client
installations only. Use the arrow key to select the appropriate character set
and press Enter.
4. A message box appears with your selections. Choose Y if the selections are
correct and you want to proceed to Step 5.
Or, choose N to return to the first configuration screen. Go to Step 1.
5. The Installation Options screen appears.
•
If you specified Intermec terminal emulation or Novell TNVTxxx on the
Select Network/Protocol screen, the Novell Product to Install is LAN
WorkPlace for DOS.
•
If you specified FTP Customer Application on the Select
Network/Protocol screen, the product to install is FTP PC/TCP for
DOS.
A message box appears when you tab out of the Drive that will be used to
build new flash images field on the Installation Options screen, if there is an
existing C:IM_FLASH subdirectory.
OK to delete subdirectory C:\IM_FLASH (Y/N)? Y
3-4
Running the Installation Utility
3
If you choose N, a message box appears asking if you want to copy the files
to another directory. Choose Y to shell out to DOS and use DOS command
to copy the files to another directory. Or, choose N.
Shell out to DOS and copy files to another directory? (Y/N)
If you choose N, a message box appears informing you that the files have
been saved and then the Installation Utility will start over.
Save the files in C:\IM_FLASH, then re-run the Install Program.
Enter the information in the Installation Options screen.
3-5
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
For help with LAN WorkPlace for DOS, see “LAN WorkPlace for DOS
Parameters” in Chapter 2.
For help with NetWare Client for DOS, see “NetWare Client for DOS
Parameters” in Chapter 2.
For help with FTP PC/TCP for DOS, see “FTP PC/TCP for DOS
Parameters” in Chapter 2.
3-6
Running the Installation Utility
3
6. Press F10 to accept your selections. A message box prompts you to enter the
JANUS 2020 Boot Utilities companion disk. Insert the disk and press any
key to continue.
Insert the Boot Utilities Companion Disk in A: or B:
7. A message box prompts you to confirm the letter of the drive containing the
disk. Use the spacebar to toggle between drives A and B. Press Enter to
confirm the disk location.
Boot Utilities Companion Disk is in Drive A:
8. A message box appears prompting you to insert the Installation Utility disk.
Insert the disk and press any key to continue.
Insert the Installation Utility Disk in A:
9. The Radio Parameters screen appears. Enter the information in the fields.
10. Press F10 to exit the screen and save your changes. The Installation and
Configuration Tasks screen indicates the progress of the installation.
If you are doing an FPT Customer Application, a message box will appear
prompting you to insert the FTP stack disk. Insert the disk and press any
key.
Please Insert the “FTP Stack Disk” in Drive A.
Shelling Out to DOS to Modify the JANUS Drive Images
When the Installation Utility has created the new drive C and drive D file
structures, the following message appears.
Shell out to DOS before JANUS images built? (Y/N)
3-7
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
If you need to modify your JANUS images to create custom .INI files, add your
application, or set a security ID, choose Y.
If you do not need to modify your JANUS images, choose N.
To use the shell out feature
1. Press any key on your PC keyboard. You go to a DOS prompt on your host
PC.
2. Use DOS commands or a DOS file editor to modify your files in
\IM_FLASH\DRIVEC and \IM_FLASH\DRIVED.
3. When you have modified the files for your JANUS drive images, type exit
and press Enter to return to the Installation Utility.
If the files you want to add to the directories exceed the capacity of the JANUS
drive C or drive D, this message appears when you type exit at the DOS
prompt.
Too many files, Shell out to reduce ? (Y/N)
To correct this problem, choose Y to shell out to DOS and delete files from
\IM_FLASH\DRIVEC to create enough free disk space.
Downloading the Modified JANUS Drive Images
The Installation Utility creates and then downloads the modified JANUS drive
C and drive D images. This process can take from 5 to 10 minutes.
To download the modified JANUS images
1. On the host PC, a message box appears asking if you want to change the
baud rate for the Interlnk connection. Choose Y to change the baud rate to
19200, 38400, or 115200. Choose N to keep the baud rate at 57600.
Set Baud Rate for Loader (Default = 57600)? (Y/N)
If you choose Y, select the baud rate. Use the spacebar to toggle the options.
Press Enter to confirm the baud rate selection.
3-8
Running the Installation Utility
3
2. Another message box appears asking if you want to change the serial port
where the JANUS device is connected to the host PC. Choose Y to change
the serial port. Choose N to keep the same serial port you selected when
you downloaded the default drive images.
Change Serial Port ? (Y/N)
If you choose Y, select the COM port. Use the spacebar to toggle between
COM1, COM2, COM3, and COM4. Press Enter to confirm the serial port
selection.
3. If the Boot Loader menu is not on the JANUS screen, use these steps.
a. Press
b. Press
c. Press
d. Press
L
IB
L
to place the JANUS device in a suspend state.
.
.
to turn the JANUS device on again.
4. From the Boot Loader menu, select LOAD and press
@
.
5. If the password is set, the Password screen prompts you to type in the
password. You are allowed three tries to enter the password.
Note: The JANUS device comes from the factory with the password disabled.
6. Press any key on your PC keyboard. The Janus 2000 Flash Loader screen
appears. This screen provides status information on the download process.
On the JANUS screen, you see the same status information.
When the Installation Utility finishes downloading the new images, a
flashing message box on the host PC informs you that the flash
programming on the JANUS device is complete.
This message appears on the JANUS screen.
Calculating Checksum
Checksum Good
7. Press any key on your PC keyboard to continue. Another message box
informs you that the installation process was successful.
8. Press any key on your PC keyboard to continue.
3-9
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
9. A message box asks you if you want to do another installation. Choose Y, if
you want to configure another JANUS device. Follow the instructions for
“Configure Multiple JANUS RF Devices” in the next section.
Or, choose N, if you have no more JANUS devices to configure and you
want to exit the Installation Utility. Follow the instructions for “Restoring
the Host PC to the Original Configuration” later in this chapter.
Note: Test the device to make sure it is configured correctly before exiting the
Installation Utility or configuring another JANUS device. If the device is not
configured correctly, choose Y and make the necessary changes.
If you configure your JANUS device to run terminal emulation software, a
terminal emulation session will start after installation is completed and you
reboot the device.
Configuring Multiple JANUS RF Devices
1. A message box appears asking you if you want to install the same
network/protocol. Choose Y to install the same TE application or SPX/IPX
protocol. Choose N to install another application.
For example, if you installed Intermec TNVTXXX TE on your JANUS
device, the message box contains this message:
Another Intermec TNVTxxx TE Installation? (Y/N)
2. If you choose N, the Select a Network/Protocol screen appears. Use the
arrow key to select the type of software that you want to install on the
device and press Enter.
3. In the Installation Options screen, make any necessary changes to the fields.
Press F10. The Radio Parameters screen appears.
4. In the Radio Parameters screen, make any necessary changes to the fields.
Press F10.
5. A message box appears asking if you want to use the shell out feature.
Choose Y if you need to make changes to your JANUS drive images. When
you are finished modifying the files for your JANUS drive images, type
exit and press Enter to return to the Installation Utility. Or, choose N.
Shell out to DOS before JANUS images built? (Y/N)
6. Make sure the next JANUS device that you want to configure is connected
to the host PC.
7. Follow Steps 1 through 9 in the previous procedure, “Downloading the
Modified JANUS Drive Images.”
3-10
Running the Installation Utility
3
Restoring the Host PC to the Original Configuration
1. When you finish configuring JANUS devices, choose N when a message
box asks you if you want to do another installation.
2. A message box asks you if you want to delete files generated by the install.
If you want to delete all of the files that were created by the Installation
Utility, choose Y.
If you want to save these files in the subdirectories on the host PC, choose
N. The Installation Utility creates batch files in these subdirectories that will
facilitate further modification to the JANUS drive images. For help using
these batch files, see “Configuring Multiple JANUS RF Devices Using Batch
Files” in Appendix B.
Do you want to delete the files generated by the install?
(Y/N)
You have successfully installed the network software on your JANUS devices.
3-11
4
Troubleshooting
Troubleshooting
4
The troubleshooting chapter provides you with information on how to troubleshoot the
Installation Utility.
General Problems
This table lists general troubleshooting problems you may have while using the
Installation Utility. Use the problem and solution columns to help you correct
the problem.
Symptom
Problem
Solution
The JANUS device is
overheating.
The application you are
running on the JANUS device
is sending too many packets to
the host.
Try reducing the number of packets
sent to 2 or 3 packets per second.
You may not have loaded all
the Novell network software
subdirectories.
1.
Make sure the Novell network
software on your host PC has the
correct directory structure.
2.
Reinstall the Novell network
software on your host PC and
rerun the Installation Utility.
Or,
The JANUS device seems to be
working better in a cold
environment than a warm
environment.
The Novell network software
on your device is not running
properly.
You have too many files in
your Novell network software
subdirectories.
You may have answered ‘Yes’
to Windows support when
loading the Novell network
software on your host PC.
Reinstall the Novell network software
and answer ‘No’ to Windows support.
You are missing some of the
files on the backup copy of the
Installation Utility disk or the
Boot companion disk.
You may not have copied all
the subdirectories when you
were making the backup copy
of the Installation Utility disk.
Recopy the disks using DISKCOPY.
You created a custom
configuration file and it
disappeared.
You may have saved the
custom JANUS.INI file to
drive E and performed a cold
boot on the device.
Recreate the custom configuration file
and save the file to drive C.
You saved a custom
configuration file to drive C
and the device cannot find it.
You may not have updated the
path for the JANUS.INI in
your AUTOEXEC.BAT.
Change the pathname to the
JANUS.INI in your AUTOEXEC.BAT
file.
Change the pathname to the
JANUS.INI in your AUTOEXEC.BAT
file.
4-3
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
Error Messages
You may encounter error messages while running the Installation Utility. This
table lists the error messages in alphabetical order. If an error message appears
on your screen, locate it in the table and use the problem and solution columns
to help you correct the error.
Error Message
Problem
Solution
C: is an Invalid Drive
(where C: is scratch drive
specified by user).
You did not specify a valid
drive for your scratch drive.
Make sure that the drive letter that you
specify is a valid physical hard drive.
Channel must be a number
between 1 and 15.
You did not select a valid
channel.
Select a number between 1 and 15 for
the channel.
Creattemp() ERROR: Path or
file name not found.
The system could not find the
\NWCLIENT\NLS directory
on the scratch drive of the host
PC. You may not have loaded
all the Novell network
software subdirectories.
1.
Make sure the NetWare Client for
DOS software on the scratch drive
of your host PC has the directory
structure listed in the section
“Modifying the JANUS Drive
Images” in Chapter 1.
2.
Reinstall NetWare Client for DOS
on your host PC and rerun the
Installation Utility.
Creattemp() ERROR:
Permission denied.
You should not get this error.
Call Intermec Technical Support.
Creattemp() ERROR: Too
many open files.
Your system is out of file
handles.
Modify the CONFIG.SYS file on the
Installation Utility disk and increase
the FILES= parameter.
DEVICE ERROR!
(hardware error on a non-disk
device.)
•
Serial link error.
•
Restart the Installation Utility.
•
System error, bad COM
port or cable.
•
Replace the bad port or cable.
Domain must be a number
between 0 and 15.
You did not select a valid
domain.
Select a number between 0 and 15 for
the domain. The domain must be the
same for all devices in the subnetwork.
Error, IP address is a special
case IP address.
You have entered a special
case IP address (host,
broadcast, or loopback
address) on the Installation
Options screen.
To enter a special case IP address,
leave the IP address field blank on the
Installation Options screen. Use the
Shell Out option to edit the NET.CFG
file and enter the special case address
in the NET.CFG.
4-4
Troubleshooting
4
Error Message
Problem
Solution
ERROR:JG20xx selected,
JG20xx platform detected
You have specified a JANUS
model number that is different
from the device that you are
configuring. xx is the 10, 20, or
50 as appropriate.
The JANUS model number you specify
during the installation must match the
device that is connected to the host PC.
Retry running the Installation Utility
and specify the correct model number.
ERROR:JG20xx selected, J2010
w/a PCMCIA back detected
You have specified a JANUS
model number that is different
from the device that you are
configuring. xx is the 10, 20, or
50 as appropriate.
The JANUS model number you specify
during the installation must match the
device that is connected to the host PC.
Retry running the Installation Utility
and specify the correct model number.
Error Loading RL2OEM.COM.
If you get this message when
the JANUS device boots, it
indicates that the radio failed
to initialize because of a
hardware problem.
Contact Intermec Technical Support.
Error, This IP address is the
same as the 0200 Controller IP
address.
You are using a duplicate IP
address.
Verify that you are using the correct IP
address.
Error, This IP address is the
same as the Host IP address.
You are using a duplicate IP
address.
Verify that you are using the correct IP
address.
Error, This IP address is the
same as the Router IP address.
You are using a duplicate IP
address.
Verify that you are using the correct IP
address.
Error, This IP address is the
same as the Station IP address.
You are using a duplicate IP
address.
Verify that you are using the correct IP
address.
External AC Power was not
Plugged In, Try Again?
External AC power supply
was not plugged into the
JANUS device.
1.
Make sure you have an external
AC power supply plugged into the
JANUS device.
2.
Choose Yes to try programming
flash memory again.
Failure Copying
C:\NET\TCP\PROTOCOL to
D:\NET\TCP
D:\NET\TCP\PROTOCOL
successfully created
A file required for the
installation was missing and
the Installation Utility created
the file.
Acknowledge the message by pressing
any key and continue with the
installation.
Flash Loader Aborted by User,
Try Again?
You pressed Ctrl-Break to
interrupt the Flash Loader
program.
Choose Yes if you want to restart the
JANUS 2000 Flash Loader program.
Flash Loader Reported a
Communication Failure Error,
Try Again?
Serial link failed.
Choose No if you do not want to
complete the installation.
•
Choose Yes to try programming
flash memory again.
•
Restart the Installation Utility.
4-5
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
Error Message
Problem
Solution
Flash Loader Reported a
General Failure Error, Try
Again?
General failure.
•
Choose Yes to try programming
flash memory again.
•
Restart the Installation Utility.
Host must be running DOS 5.0
or above.
You are not running DOS 5.0
or above on your host PC.
•
Install DOS 5.0 or above on your
host PC.
•
Use a different host PC that is
running DOS 5.0 or above.
INSTALL.EXE Error:
Command line parameter
error.
Software error.
Contact your Intermec representative.
INSTALL.EXE Error: File is
Wrong Size.
Software error.
Contact your Intermec representative.
INSTALL.EXE Error: File not
Found.
Software error.
Contact your Intermec representative.
INSTALL.EXE Error: Unable
to Open File.
Software error.
Contact your Intermec representative.
Installation Disk MUST be in
Drive A.
•
You are trying to run
PCSETUP from drive B.
•
The Installation Utility
disk is no longer in drive
A.
Place the Installation Utility disk in
drive A of your host PC and type
a:\install.
Insufficient Memory.
Invalid Port, LOAD Not
Selected, or Cable Unplugged,
Try Again?
System error.
•
You may have selected the
wrong serial port on your
host PC (COM1, COM2,
COM3, or COM4).
•
You may not have selected
LOAD and pressed e on
your JANUS device.
•
Manufacturing ID not
Received, Try Again?
4-6
You may not have the host
PC and the JANUS device
connected with a null
modem cable.
Manufacturing ID not
received.
•
Restart the Installation Utility.
•
Perform diagnostics on the host
PC.
•
Make sure that you selected the
correct serial port on your host PC
where your JANUS device is
connected. Choose Yes to try
again.
•
Make sure you selected LOAD and
pressed
on your JANUS
device. Choose Yes to try again.
•
Connect a null modem cable from
your host PC to the serial port on
the JANUS. Choose Yes to try
again.
@
Answer Yes to try programming flash
memory again.
Troubleshooting
4
Error Message
Problem
Solution
Need at least rK of Extended
Memory, only have iK.
•
You do not have enough
extended memory on your
host PC.
Make sure that your host PC has at
least 4MB of RAM.
•
You are running the
Installation Utility on a
host PC that does not
follow the established
CMOS standards.
r = Total kilobytes of extended
memory required
i = Total kilobytes of extended
memory installed
You must have at least 14MB
of free space on your scratch
drive.
•
Make sure that you specify a valid
physical hard drive.
•
Remove or move files from the
drive you are using for the scratch
drive until you have 14MB of free
space.
Path must include a drive
specifier.
You did not type a drive letter
when you specified the
pathname.
Add a drive letter, colon, and back
slash to the pathname. For example:
C:\
Subchannel must be a number
between 1 and 15.
You did not select a valid
subchannel.
Select a number between 1 and 15 for
the subchannel.
Unable to Create New JANUS
Drive C Image!
System error. You may have
copied too many files to the
\IM_FLASH\DRIVEC
directory.
Restart the Installation Utility.
Unable to Create New JANUS
Drive D Image!
System error.
Restart the Installation Utility.
Unable to Find Application
Image in Archive File.
Bad companion disk 1.
Make another copy of the Boot Utilities
companion disk from the original disk.
Unable to Find Specified Block
in 4MEG2_4.INI.
Software error. You may have
modified this .INI file.
Contact your Intermec representative.
Unable to Find System Image
in Archive File.
Bad boot utilities disk.
Make another copy of the Boot Utilities
companion disk from the original disk.
Unable to Find User Image in
Archive File.
Bad boot utilities disk.
Make another copy of the Boot Utilities
companion disk from the original disk.
Unable to Free Enough Drive
D Space.
You have too many files in the
NetWare Client or LAN
WorkPlace subdirectories.
Review the source subdirectories and
eliminate unnecessary files. If the
software was installed using Windows
support, delete the Windows files and
reinstall the software without
Windows support.
Only X bytes available on C:,
Need Y.
X = Total bytes available.
C: = Scratch drive specified by
user.
Y = Total bytes required.
4-7
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
Error Message
Problem
Solution
Unable to Update Flash, Try
Again?
Unknown flash loader error.
Contact your Intermec representative.
Unable to Verify Installation
Path.
You specified an installation
path that does not exist.
Enter the name of an installation path
that does exist.
v1.31 detected, must be v4.00 v4.99
The JANUS software you are
using is an older version and
can’t be installed.
Make sure you follow the procedure to
download the default drive images
from the Installation Utility disk to the
JANUS device.
VPP Programming Voltage not
Present, Try Again?
AC adapter bad, not plugged
in, or loose.
•
Connect an external AC power
supply to the JANUS device (or
make sure it is pushed in all the
way).
•
Choose Yes to try programming
the JANUS flash memory again.
WARNING, current IP address
matches previous IP address.
Do you want to change the
current IP address?
On additional installations, the
Installation Utility provides
this warning message if you
use a duplicate IP address
Verify you are using the correct IP
address and continue. You have the
option of changing the IP address at
this time.
Warning, HOSTS Too Large or
Not Found, Continue?
Your HOSTS file must be less
than 50K.
•
Ignore this message if you do not
have a HOSTS file and answer Yes
to continue.
•
Reduce the number of alias lists in
your HOSTS file and answer Yes to
continue.
Drive A Error Messages
These disk drive error messages refer to the current drive being accessed. This
table lists the error messages in alphabetical order. If an error message appears
on your screen, locate it in the table and use the problem and solution columns
to help you correct the error.
Error Message
Problem
Solution
Error: data error (CRC) on the
A: Drive.
DOS was unable to read or
write the data correctly.
•
Retry the operation.
•
Replace the disk.
This error is usually caused by
a defective area on the disk.
•
Check your disk using the
CHKDSK command.
4-8
Troubleshooting
4
Error Message
Problem
Solution
Error: general failure on the A:
Drive.
•
The disk is incompatible
with your host PC drive.
•
•
The drive door is open or
the disk is not in the drive.
Make sure that you are not using a
high density disk in a low density
drive.
•
•
Disk is not properly
formatted.
Properly insert the disk and close
the drive door.
•
Reformat the disk.
•
Replace the disk.
Error: invalid disk change on
the A: Drive.
You changed disks before all
the files were closed.
Reinsert the original disk so the files
can be closed.
Error: read fault on the A:
Drive.
•
Drive media error.
•
DOS was unable to read
data from the disk.
• Make sure that the disk is properly
seated in the drive and retry the
operation.
• Replace the disk.
Error: sector not found on the
A: Drive.
Error: seek error on the A:
Drive.
•
Drive media error.
• Retry the operation.
•
DOS could not find the
disk sector containing the
requested data.
• Make a copy of the bad disk and
reformat the bad disk.
The disk drive could not find
the specified disk cylinder.
• Make another copy of the
Installation Utility disk from the
original Installation Utility disk.
• Retry the operation.
• Replace the disk.
• Perform diagnostics to determine
the type of failure.
Error: unknown media type on
the A: Drive.
Drive media error.
Installation Disk w/file
4MEG2_4.INI MUST be in
Drive A.
The Installation Utility cannot
find the 4MEG2_4.INI file.
• Replace the disk.
• Reformat the disk.
• Make sure that you inserted the
Installation Utility disk in drive A.
• Make sure the Installation Utility
disk in drive A contains the
4MEG2_4.INI file. If you cannot
find the file, contact Intermec
Technical Support.
4-9
A
Deleted, Modified, and New Files
Deleted, Modified, and New Files
A
This appendix lists the files that the Installation Utility deletes from the JANUS
devices. It provides printouts of the modified CONFIG.SYS and AUTOEXEC.BAT files
and the new NET.CFG, NET.BAT, APP.BAT, GO.BAT, UNNET.BAT, PCTCP.INI, and
UDPPLUS.INI files. It also lists the minimum required files for a LAN WorkPlace for
DOS installation.
Deleted Files
This section lists the files that are deleted from the JANUS drives C and D. If
you use the shell out feature, you can restore selected files that the Installation
Utility removes. You can also add the application that you will be running to
drive C or D. Use DOS commands to choose which files you want to keep and
which ones you want to delete.
Files Removed From Drive C
The Installation Utility removes the following files from drive C on the JANUS
device. These files are stored in \IM_FLASH\DRIVECX.
CARDINFO.EXE
COMMAND.COM
INITENV.EXE
JANUS.MRF
MCFORMAT.EXE
Files Removed From Drive D
To fit the Intermec or Novell software on the JANUS device, the Installation
Utility needs at least 700K of free space.
The Installation Utility removes these files from drive D on the JANUS device.
These files are stored in the \IM_FLASH\DRIVEDX directory.
ANSI.SYS
LABEL.EXE
ATTRIB.EXE
PHIMEC.EXE
DEBUG.EXE
PHPCSTD.EXE
EDLIN.EXE
RFPH.EXE
FC.EXE
SETVER.EXE
INTERSVR.EXE
SORT.EXE
IRL.BAT
SUBST.EXE
IRL001.DAT
UNDELETE.EXE
IRLDESK.EXE
A-3
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
These files are conditionally deleted from drive D if additional space is
required. Files are deleted in the order listed.
ANSI.SYS
PHPCSTD.EXE
PHIMEC.EXE
INTERSVR.EXE
CHKDSK.EXE
FORMAT.COM
MEM.EXE
MORE.COM
XCOPY.EXE
DOSKEY.EXE
Modified CONFIG.SYS File
The Installation Utility modifies the CONFIG.SYS file that was on the JANUS
device. The following are examples of the new files.
JG2010 CONFIG.SYS
REM *
REM * FILENAME: CONFIG.SYS
REM *
REM * PROD ID: J2010
REM *
REM * VERSION: 4.04H
REM *
REM * SETUP BOOT MENU ITEMS
[MENU]
MENUITEM=SRAM, SRAM PCCARD
MENUITEM=ATA, ATA PCCARD
MENUITEM=FLASH, FLASH PCCARD
MENUITEM=IO, I/O PCCARD
MENUITEM=NO, NO PCCARD
MENUCOLOR=15,0
MENUDEFAULT=SRAM, 20
[COMMON]
REM * COMMON TO ALL CONFIGURATIONS
REM * SET ENVIRONMENT SIZE
SHELL=COMMAND.COM /E:2000 /P
A-4
Deleted, Modified, and New Files
A
JG2010 CONFIG.SYS (continued)
DEVICE=D:\HIMEM.SYS /TESTMEM:OFF
DOS=HIGH
REM * LOAD APM POWER MANAGEMENT
DEVICE=D:\POWER.EXE /LOW
REM * LOAD DRIVE E: RAMDISK
DEVICE=D:\SRAMDISK.SYS 256 512 /E
REM * REQUIRED TO RESUME PCCARD CONTROLLER
INSTALL=D:\CARD_SR.EXE
[SRAM]
REM * MEMORY CARDS
DEVICE=D:\CS.EXE /POLL:1
DEVICE=D:\CSALLOC.EXE D:\CSALLOC.INI
DEVICE=MTSRAM.EXE
DEVICE=MTDDRV.EXE
[ATA]
REM * ATA CARDS
DEVICE=D:\CS.EXE /POLL:1
DEVICE=D:\CSALLOC.EXE D:\CSALLOC.INI
DEVICE=D:\ATADRV.EXE /S:2
DEVICE=MTDDRV.EXE
DEVICE=D:\CARDID.EXE
[FLASH]
REM * FLASH CARDS
DEVICE=D:\CS.EXE /POLL:1
DEVICE=D:\CSALLOC.EXE D:\CSALLOC.INI
DEVICE=D:\MTI1.EXE
DEVICE=D:\MTI2P.EXE
DEVICE=MTDDRV.EXE
DEVICE=D:\FTL.EXE
[IO]
REM * I/O AND MEMORY CARDS
DEVICE=D:\CS.EXE /POLL:1
DEVICE=D:\CSALLOC.EXE D:\CSALLOC.INI
DEVICE=MTSRAM.EXE
DEVICE=MTDDRV.EXE
DEVICE=D:\CARDID.EXE
[NO]
REM * NO PCCARD CARDS
A-5
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
JG2010 CONFIG.SYS (continued)
[COMMON]
REM * AUTO LOADER HOOK IF ACTIVE
DEVICE=D:\INTERLNK.EXE /DRIVES:5 /NOPRINTER /COM:1 /AUTO
BUFFERS=10
REM * FOR INTERMEC IRL SUPPORT.
FILES=50
STACKS=9,256
JG2020 CONFIG.SYS
REM *
REM * FILENAME: CONFIG.SYS
REM *
REM * PROD ID: J2020
REM *
REM * VERSION: 4.01D
REM *
REM * SETUP BOOT MENU ITEMS
[MENU]
MENUITEM=SRAM, SRAM PCCARD
MENUITEM=ATA, ATA PCCARD
MENUITEM=FLASH, FLASH PCCARD
MENUITEM=IO, I/O PCCARD
MENUITEM=NO, NO PCCARD
MENUCOLOR=15,0
MENUDEFAULT=SRAM, 20
[COMMON]
REM * COMMON TO ALL CONFIGURATIONS
REM * SET ENVIRONMENT SIZE
SHELL=COMMAND.COM /E:2000 /P
DEVICE=D:\HIMEM.SYS /TESTMEM:OFF
DOS=HIGH
REM * LOAD APM POWER MANAGEMENT
DEVICE=D:\POWER.EXE /LOW
REM * LOAD DRIVE E: RAMDISK
DEVICE=D:\SRAMDISK.SYS 256 512 /E
A-6
Deleted, Modified, and New Files
A
JG2020 CONFIG.SYS (continued)
REM * REQUIRED TO RESUME PCCARD CONTROLLER
INSTALL=D:\CARD_SR.EXE
[SRAM]
REM * MEMORY CARDS
DEVICE=D:\CS.EXE /POLL:1
DEVICE=D:\CSALLOC.EXE D:\CSALLOC.INI
DEVICE=MTSRAM.EXE
DEVICE=MTDDRV.EXE
[ATA]
REM * ATA CARDS
DEVICE=D:\CS.EXE /POLL:1
DEVICE=D:\CSALLOC.EXE D:\CSALLOC.INI
DEVICE=D:\ATADRV.EXE /S:2
DEVICE=MTDDRV.EXE
DEVICE=D:\CARDID.EXE
[FLASH]
REM * FLASH CARDS
DEVICE=D:\CS.EXE /POLL:1
DEVICE=D:\CSALLOC.EXE D:\CSALLOC.INI
DEVICE=D:\MTI1.EXE
DEVICE=D:\MTI2P.EXE
DEVICE=MTDDRV.EXE
DEVICE=D:\FTL.EXE
[IO]
REM * I/O AND MEMORY CARDS
DEVICE=D:\CS.EXE /POLL:1
DEVICE=D:\CSALLOC.EXE D:\CSALLOC.INI
DEVICE=MTSRAM.EXE
DEVICE=MTDDRV.EXE
DEVICE=D:\CARDID.EXE
[NO]
REM * NO PCCARD CARDS
[COMMON]
REM * AUTO LOADER HOOK IF ACTIVE
DEVICE=D:\INTERLNK.EXE /DRIVES:5 /NOPRINTER /COM:1 /AUTO
BUFFERS=10
REM * FOR INTERMEC IRL SUPPORT.
FILES=50
STACKS=9,256
A-7
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
JG2050 CONFIG.SYS
REM *
REM * FILENAME: CONFIG.SYS
REM *
REM * PROD ID: J2050
REM *
REM * VERSION: 4.01F
REM *
REM * SETUP BOOT MENU ITEMS
[MENU]
MENUITEM=SRAM, SRAM PCCARD
MENUITEM=ATA, ATA PCCARD
MENUITEM=FLASH, FLASH PCCARD
MENUITEM=IO, I/O PCCARD
MENUITEM=NO, NO PCCARD
MENUCOLOR=15,0
MENUDEFAULT=SRAM, 20
[COMMON]
REM * COMMON TO ALL CONFIGURATIONS
REM * SET ENVIRONMENT SIZE
SHELL=COMMAND.COM /E:2000 /P
DEVICE=D:\HIMEM.SYS /TESTMEM:OFF
DOS=HIGH
REM * LOAD APM POWER MANAGEMENT
DEVICE=D:\POWER.EXE /LOW
REM * LOAD DRIVE E: RAMDISK
DEVICE=D:\SRAMDISK.SYS 256 512 /E
REM * REQUIRED TO RESUME PCCARD CONTROLLER
INSTALL=D:\CARD_SR.EXE
[SRAM]
REM * MEMORY CARDS
DEVICE=D:\CS.EXE /POLL:1
DEVICE=D:\CSALLOC.EXE D:\CSALLOC.INI
DEVICE=MTSRAM.EXE
DEVICE=MTDDRV.EXE
A-8
Deleted, Modified, and New Files
A
JG2050 CONFIG.SYS (continued)
[ATA]
REM * ATA CARDS
DEVICE=D:\CS.EXE /POLL:1
DEVICE=D:\CSALLOC.EXE D:\CSALLOC.INI
DEVICE=D:\ATADRV.EXE /S:2
DEVICE=MTDDRV.EXE
DEVICE=D:\CARDID.EXE
[FLASH]
REM * FLASH CARDS
DEVICE=D:\CS.EXE /POLL:1
DEVICE=D:\CSALLOC.EXE D:\CSALLOC.INI
DEVICE=D:\MTI1.EXE
DEVICE=D:\MTI2P.EXE
DEVICE=MTDDRV.EXE
DEVICE=D:\FTL.EXE
[IO]
REM * I/O AND MEMORY CARDS
DEVICE=D:\CS.EXE /POLL:1
DEVICE=D:\CSALLOC.EXE D:\CSALLOC.INI
DEVICE=MTSRAM.EXE
DEVICE=MTDDRV.EXE
DEVICE=D:\CARDID.EXE
[NO]
REM * NO PCCARD CARDS
[COMMON]
REM * AUTO LOADER HOOK IF ACTIVE
DEVICE=D:\INTERLNK.EXE /DRIVES:5 /NOPRINTER /COM:1 /AUTO
BUFFERS=10
REM * FOR INTERMEC IRL SUPPORT.
FILES=50
STACKS=9,256
A-9
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
Modified AUTOEXEC.BAT File
The Installation Utility modifies the AUTOEXEC.BAT file installed on the
JANUS device. The following are examples of the new files.
JG2010 AUTOEXEC.BAT
@ECHO OFF
CLS
:*
:* FILENAME: AUTOEXEC.BAT
:*
:* PRODUCT: J2010
:*
:* VERSION: 4.04H
:*
:* ------------- ! AUTO-INTERROGATING DRIVE C: INSTALLATION ! -------------:*
:* INTERMEC AUTOMATIC DRIVE C: INSTALLER HOOK; (DO NOT REMOVE!)
:*
ECHO OFF
CLS
IF NOT EXIST AUTOINST.BAT GOTO T2
CALL AUTOINST
GOTO T3
:T2
IF EXIST D:\AUTOINST.BAT CALL D:\AUTOINST
:T3
:*
:* ------------- AUTO-INTERROGATING DRIVE C: INSTALLATION ENDS ------------SET PROMPT=$P$G
PATH=C:\;D:\;E:\
REM * REQUIRED FOR MORE.COM TO WORK ON ROM DRIVES
SET TEMP=E:\
REM * USED BY READER SERVICES
SET IM_ERRPATH=E:\
D:
REM * REQUIRED TO RESUME IF NO APM_4M
D:\IPM_4M.EXE
REM * LOAD FOR PCMCIA CARD DETECT ON RESUME
REM D:\APM_4M.EXE
A-10
Deleted, Modified, and New Files
A
JG2010 AUTOEXEC.BAT (continued)
REM * LOAD BARCODE READER FUNCTIONALITY
IF EXIST D:\LOADUMA.EXE D:\LOADUMA
REM * REQUIRED FOR COMPLETE DISPLAY FUNCTION
D:\IM_DISP.EXE
REM * SET READER CONFIG
D:\IC /L C:\J24TE.INI
REM * CONFIGURE BARCODE WEDGE (DEFAULT DISABLE)
REM *
0= DISABLE WITH EXKBD
REM *
1= ENABLE WITH EXKBD
REM *
2= ENABLE WITHOUT EXKBD
REM *
3= DISABLE WITHOUT EXKBD
REM *
4= DISPLAY STATUS
REM D:\KWC.COM
REM * LOADS ONLY IF RF BACK INSTALLED
REM RFPH 4
REM * IF FTA EXISTS CALL TO DETERMINE IF HOST TRANSFER
REM * NOTE: THE RAMDRIVE E: IS USED SO FILES CAN BE
REM *
ACCESSED WITHOUT SPECIFYING THE FULL PATH.
IF NOT EXIST C:\FTA.EXE GOTO DOS_PROMPT
E:
FTA.EXE CHECKHOST; EXIT
REM * START POSSIBLE HOST SET IM_APPLICATION
REM * TO EXECUTE A DOWNLOADED APPLICATION
%IM_APPLICATION%
:DOS_PROMPT
REM * END AT C: DOS PROMPT
C:
CLS
D:
CD \NET\BIN
C:
PATH=%PATH%;D:\NET\BIN;D:\NET\DRIVERS
IF EXIST C:\DOS_NLS.BAT CALL C:\DOS_NLS.BAT
D:\NET\DRIVERS\MINIPM.EXE
D:\KWC.COM 0
@ECHO.
@ECHO.
CHOICE /C:YN /TY,5 Run Network?
IF ERRORLEVEL 2 GOTO PROMPT
CALL NET.BAT
IF EXIST APP.BAT CALL APP.BAT
IF EXIST UNNET.BAT CALL UNNET.BAT
:PROMPT
A-11
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
JG2020 AUTOEXEC.BAT
@ECHO OFF
CLS
:*
:* FILENAME: AUTOEXEC.BAT
:*
:* PRODUCT: J2020
:*
:* VERSION: 4.01D
:*
:* ------------- ! AUTO-INTERROGATING DRIVE C: INSTALLATION ! -------------:*
:* INTERMEC AUTOMATIC DRIVE C: INSTALLER HOOK; (DO NOT REMOVE!)
:*
ECHO OFF
CLS
IF NOT EXIST AUTOINST.BAT GOTO T2
CALL AUTOINST
GOTO T3
:T2
IF EXIST D:\AUTOINST.BAT CALL D:\AUTOINST
:T3
:*
:* ------------- AUTO-INTERROGATING DRIVE C: INSTALLATION ENDS ------------SET PROMPT=$P$G
PATH=C:\;D:\;E:\
REM * REQUIRED FOR MORE.COM TO WORK ON ROM DRIVES
SET TEMP=E:\
REM * USED BY READER SERVICES
SET IM_ERRPATH=E:\
D:
REM * REQUIRED TO RESUME IF NO APM_4M
D:\IPM_4M.EXE
REM * LOAD FOR PCMCIA CARD DETECT ON RESUME
REM D:\APM_4M.EXE
REM * LOAD BARCODE READER FUNCTIONALITY
IF EXIST D:\LOADUMA.EXE D:\LOADUMA
A-12
Deleted, Modified, and New Files
A
JG2020 AUTOEXEC.BAT (continued)
REM * REQUIRED FOR COMPLETE DISPLAY FUNCTION
D:\IM_DISP.EXE
REM * SET READER CONFIG
D:\IC /L C:\J24TE.INI
REM
REM
REM
REM
REM
REM
REM
* CONFIGURE BARCODE WEDGE (DEFAULT DISABLE)
*
0= DISABLE WITH EXKBD
*
1= ENABLE WITH EXKBD
*
2= ENABLE WITHOUT EXKBD
*
3= DISABLE WITHOUT EXKBD
*
4= DISPLAY STATUS
D:\KWC.COM
REM * LOADS ONLY IF RF BACK INSTALLED
REM RFPH 4
REM * IF FTA EXISTS CALL TO DETERMINE IF HOST TRANSFER
REM * NOTE: THE RAMDRIVE E: IS USED SO FILES CAN BE
REM *
ACCESSED WITHOUT SPECIFYING THE FULL PATH.
IF NOT EXIST C:\FTA.EXE GOTO DOS_PROMPT
E:
FTA.EXE CHECKHOST; EXIT
REM * START POSSIBLE HOST SET IM_APPLICATION
REM * TO EXECUTE A DOWNLOADED APPLICATION
%IM_APPLICATION%
:DOS_PROMPT
REM * END AT C: DOS PROMPT
C:
CLS
D:
CD \NET\BIN
C:
PATH=%PATH%;D:\NET\BIN;D:\NET\DRIVERS
IF EXIST C:\DOS_NLS.BAT CALL C:\DOS_NLS.BAT
D:\NET\DRIVERS\MINIPM.EXE
D:\KWC.COM 0
@ECHO.
@ECHO.
CHOICE /C:YN /TY,5 Run Network?
IF ERRORLEVEL 2 GOTO PROMPT
CALL NET.BAT
IF EXIST APP.BAT CALL APP.BAT
IF EXIST UNNET.BAT CALL UNNET.BAT
:PROMPT
A-13
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
JG2050 AUTOEXEC.BAT
@echo off
cls
:*
:* Filename: autoexec.bat
:*
:* Product: J2050
:*
:* Version: 4.01f
:*
:* ------------- ! AUTO-INTERROGATING DRIVE C: INSTALLATION ! -------------:*
:* Intermec automatic Drive C: installer hook; (DO NOT REMOVE!)
:*
ECHO OFF
CLS
IF NOT EXIST AUTOINST.BAT GOTO T2
CALL AUTOINST
GOTO T3
:T2
IF EXIST D:\AUTOINST.BAT CALL D:\AUTOINST
:T3
:*
:* ------------- AUTO-INTERROGATING DRIVE C: INSTALLATION ENDS ------------set prompt=$p$g
path=c:\;d:\;e:\
REM * required for more.com to work on rom drives
set temp=e:\
REM * used by reader services
set IM_ERRPATH=e:\
d:
REM * required to resume if no apm_4m
d:\ipm_4m.exe
REM * load for PCMCIA card detect on resume
REM d:\apm_4m.exe
REM * load barcode reader functionality
IF exist d:\loaduma.exe d:\loaduma
REM * required for complete display function
d:\im_disp.exe
REM * set reader config
d:\ic /l e:\janus.ini
A-14
Deleted, Modified, and New Files
A
JG2050 AUTOEXEC.BAT (continued)
rem * configure barcode wedge (default disable)
rem *
0= Disable with Exkbd
rem *
1= Enable with Exkbd
rem *
2= Enable without Exkbd
rem *
3= Disable without Exkbd
rem *
4= Display Status
d:\kwc.com 0
REM * loads only if RF back installed
RFPH 4
rem * IF FTA exists call to determine if host transfer
rem * Note: The Ramdrive e: is used so files can be
rem *
accessed without specifying the full path.
IF not exist c:\fta.exe goto DOS_PROMPT
e:
fta.exe CheckHost; Exit
rem * Start possible host set IM_APPLICATION
rem * to execute a downloaded application
%IM_APPLICATION%
:DOS_PROMPT
rem * End at c: dos prompt
c:
cls
A-15
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
NET.CFG File
The Installation Utility creates a NET.CFG file based on the software you are
using and the network parameters you set. The following are examples of what
the NET.CFG files may look like.
JG2010 NET.CFG
LINK SUPPORT
BUFFERS 8 1500
MEMPOOL 4096
MAX STACKS 8
PROTOCOL TCPIP
PATH LANG_CFG
PATH SCRIPT
PATH PROFILE
PATH LWP_CFG
PATH TCP_CFG
IP_ROUTER
IP_NETMASK
IP_ADDRESS
D:\NET\LANG
D:\NET\SCRIPT
D:\NET\PROFILE
D:\NET\HSTACC
D:\NET\TCP
192.9.175.0
255.255.255.0
192.9.175.235
PROTOCOL IPXODI
SPX LISTEN TIMEOUT 5400
SPX VERIFY TIMEOUT 5400
;WAIT TIME IN TICS BEFORE IT REQUESTS A SEND
;FREQ IN TICKS THAT SPX SENDS A PACKET
NETWARE DOS REQUESTER
FIRST NETWORK DRIVE = H
USE DEFAULTS = OFF
VLM = CONN.VLM
VLM = IPXNCP.VLM
VLM = TRAN.VLM
VLM = SECURITY.VLM
VLM = NDS.VLM
VLM = BIND.VLM
VLM = NWP.VLM
VLM = FIO.VLM
VLM = GENERAL.VLM
VLM = REDIR.VLM
VLM = PRINT.VLM
VLM = NETX.VLM
A-16
Deleted, Modified, and New Files
A
JG2010 NET.CFG (continued)
LINK DRIVER RL2OEM
FRAME ETHERNET_802.2
FRAME ETHERNET_II
INT 7
PORT 270
SNIFF_TIME 0
;KEEP-ALIVE PACKET DISABLED
PEER_TO_PEER N
;BRIDGING ONLY
RADIO_MODE 0
;800KBS MODE
ROAM_CONFIG 0
;SLOW ROAMING
STATION_TYPE 0
DOMAIN 0
INACTIVITY_MIN 0
INACTIVITY_SEC 5
JG2020 NET.CFG
LINK SUPPORT
BUFFERS 8 1500
MEMPOOL 4096
MAX STACKS 8
PROTOCOL TCPIP
PATH LANG_CFG
PATH SCRIPT
PATH PROFILE
PATH LWP_CFG
PATH TCP_CFG
IP_ROUTER
IP_NETMASK
IP_ADDRESS
D:\NET\LANG
D:\NET\SCRIPT
D:\NET\PROFILE
D:\NET\HSTACC
D:\NET\TCP
192.9.175.0
255.255.255.0
192.9.175.235
PROTOCOL IPXODI
SPX LISTEN TIMEOUT 5400
SPX VERIFY TIMEOUT 5400
;WAIT TIME IN TICS BEFORE IT REQUESTS A SEND
;FREQ IN TICKS THAT SPX SENDS A PACKET
A-17
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
JG2020 NET.CFG (continued)
NETWARE DOS REQUESTER
FIRST NETWORK DRIVE = H
USE DEFAULTS = OFF
VLM = CONN.VLM
VLM = IPXNCP.VLM
VLM = TRAN.VLM
VLM = SECURITY.VLM
VLM = NDS.VLM
VLM = BIND.VLM
VLM = NWP.VLM
VLM = FIO.VLM
VLM = GENERAL.VLM
VLM = REDIR.VLM
VLM = PRINT.VLM
VLM = NETX.VLM
LINK DRIVER RL2OEM
FRAME ETHERNET_802.2
FRAME ETHERNET_II
INT 7
PORT 270
SNIFF_TIME 0
;KEEP-ALIVE PACKET DISABLED
PEER_TO_PEER N
;BRIDGING ONLY
RADIO_MODE 0
;800KBS MODE
ROAM_CONFIG 0
;SLOW ROAMING
STATION_TYPE 0
DOMAIN 0
INACTIVITY_MIN 0
INACTIVITY_SEC 5
JG2050 NET.CFG
LINK SUPPORT
BUFFERS 8 1500
MEMPOOL 4096
MAX STACKS 8
PROTOCOL TCPIP
PATH LANG_CFG
PATH SCRIPT
PATH PROFILE
PATH LWP_CFG
PATH TCP_CFG
A-18
D:\NET\LANG
D:\NET\SCRIPT
D:\NET\PROFILE
D:\NET\HSTACC
D:\NET\TCP
Deleted, Modified, and New Files
A
JG2050 NET.CFG (continued)
IP_ROUTER
IP_NETMASK
IP_ADDRESS
192.9.175.0
255.255.255.0
192.9.175.235
PROTOCOL IPXODI
SPX LISTEN TIMEOUT 5400
SPX VERIFY TIMEOUT 5400
;WAIT TIME IN TICS BEFORE IT REQUESTS A SEND
;FREQ IN TICKS THAT SPX SENDS A PACKET
NETWARE DOS REQUESTER
FIRST NETWORK DRIVE = H
USE DEFAULTS = OFF
VLM = CONN.VLM
VLM = IPXNCP.VLM
VLM = TRAN.VLM
VLM = SECURITY.VLM
VLM = NDS.VLM
VLM = BIND.VLM
VLM = NWP.VLM
VLM = FIO.VLM
VLM = GENERAL.VLM
VLM = REDIR.VLM
VLM = PRINT.VLM
VLM = NETX.VLM
LINK DRIVER RL2OEM
FRAME ETHERNET_802.2
FRAME ETHERNET_II
INT 7
PORT 270
SNIFF_TIME 0
;KEEP-ALIVE PACKET DISABLED
PEER_TO_PEER N
;BRIDGING ONLY
RADIO_MODE 0
;800KBS MODE
ROAM_CONFIG 0
;SLOW ROAMING
STATION_TYPE 0
DOMAIN 0
INACTIVITY_MIN 0
INACTIVITY_SEC 0
A-19
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
About the NET.CFG Parameters
Depending on how you filled in the fields in the Installation Options screen, the
following parameters are added to the NET.CFG file.
IP Address, Default Router, Subnet Mask When the TCP/IP protocol stack is
loaded, it checks for values for the IP address, default router, and subnet mask.
If it does not find values for these parameters, the TCP/IP stack generates a
RARP packet to be processed by a BOOTP server or an RARP server.
If you specified values for these parameters in the Installation Options screen,
the Installation Utility adds the following lines under the subroutine Protocol
TCPIP:
ip_router
ip_netmask
ip_address
defaultrouter
subnetmask
ipaddress
PCTCP.INI File
The PCTCP.INI file is used to configure the FTP stack. PCTCP.INI is provided
on the FTP stack disk and is modified by the Install Tool to incorporate the IP
address information.
[[pctcp time]
time-zone-subsection = us-pst
dst-begins = 94
dst-ends = 305
[pctcp time us-pst]
time-zone-name = PST
time-zone-full-name = US/Pacific Standard Time
time-zone-offset = 8:00
dst-rule = US Federal
dst-name = PDT
dst-offset = 7:00
dst-begin-day = M4.1.0
dst-end-day = M10.5.0
dst-begin-time = 2:00
dst-end-time = 2:00
[pctcp ifcust 0]
ip-address =
subnet-mask =
router =
interface-type = PKTDRV
frame-type = DIX-Ethernet
A-20
Deleted, Modified, and New Files
A
PCTCP.INI File (continued)
[pctcp general]
etc-dir = c:\
user = PQM
name-resolution = dns
time-zone-name = PST
time-zone-offset = 480
[pctcp kernel]
interface = ifcust 0
kernel-does-dns = yes
mtu-discovery = yes
multicast = no
pktdrv-loopback = yes
router-discovery = no
[pctcp language]
dll = enu
[pctcp idrive]
map-character = ~
[pctcp netbios]
cache-elements = 10
names = 16
[pctcp vpctcp]
MinimumCopySpace = 12
HiTSRFenceSegment = A000h
[pctcp pctcpnet]
use-advanced = yes
A-21
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
NET.BAT File
The installation utility creates a NET.BAT file for the Novell software you are
using. The NET.BAT file loads the radio and network files.
JG2010 NET.BAT for NetWare Client
C:CD \
SET NWLANGUAGE=ENGLISH
D:\NWCLIENT\LSL.COM
D:\NWCLIENT\RL2OEM.COM
IF NOT ERRORLEVEL 1 GOTO CARD_OK
ECHO *
ECHO * ERROR LOADING
ECHO * RL2OEM.COM
ECHO *
PAUSE
:CARD_OK
D:\NWCLIENT\IPXODI.COM
D:\NWCLIENT\VLM.EXE /MX
JG2010 NET.BAT for LanWorkplace
C:
CD \
D:\NET\DRIVERS\LSL.COM
D:\NET\DRIVERS\RL2OEM.COM
IF NOT ERRORLEVEL 1 GOTO CARD_OK
ECHO *
ECHO * ERROR LOADING
ECHO * RL2OEM.COM
ECHO *
PAUSE
:CARD_OK
SET NAME=renaldo
BREAK ON
D:\NET\DRIVERS\TCPIP.EXE
A-22
Deleted, Modified, and New Files
A
JG2010 NET.BAT for FTP Application
C:
CD \
D:\NET\DRIVERS\LSL.COM
D:\NET\DRIVERS\RL2OEM.COM
IF NOT ERRORLEVEL 1 GOTO CARD_OK
ECHO *
ECHO * ERROR LOADING
ECHO * RL2OEM.COM
ECHO *
PAUSE
:CARD_OK
SET PCTCP=C:\PCTCP.INI
BREAK ON
D:\NET\BIN\ODIPKT.COM
D:\NET\BIN\ETHDRV.EXE
D:\NET\BIN\LWPE
JG2020 NET.BAT for NetWare Client
SET NWLANGUAGE=ENGLISH
D:\NWCLIENT\LSL.COM
D:\NWCLIENT\RL2OEM.COM
IF NOT ERRORLEVEL 1 GOTO CARD_OK
ECHO *
ECHO * ERROR LOADING
ECHO * RL2OEM.COM
ECHO *
PAUSE
:CARD_OK
D:\NWCLIENT\IPXODI.COM
D:\NWCLIENT\VLM.EXE /MX /PS=Newone
A-23
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
JG2020 NET.BAT for LAN WorkPlace
D:\NET\DRIVERS\LSL.COM
D:\NET\DRIVERS\RL2OEM.COM
IF NOT ERRORLEVEL 1 GOTO CARD_OK
ECHO *
ECHO * ERROR LOADING
ECHO * RL2OEM.COM
ECHO *
PAUSE
:CARD_OK
SET NAME=Yourname
BREAK ON
D:\NET\DRIVERS\TCPIP.EXE
JG2020 NET.BAT for FTP Application
C:
CD \
D:\NET\DRIVERS\LSL.COM
D:\NET\DRIVERS\RL2OEM.COM
IF NOT ERRORLEVEL 1 GOTO CARD_OK
ECHO *
ECHO * ERROR LOADING
ECHO * RL2OEM.COM
ECHO *
PAUSE
:CARD_OK
SET PCTCP=C:\PCTCP.INI
BREAK ON
D:\NET\BIN\ODIPKT.COM
D:\NET\BIN\ETHDRV.EXE
D:\NET\BIN\LWPE
A-24
Deleted, Modified, and New Files
A
JG2050 NET.BAT for NetWare Client
SET NWLANGUAGE=ENGLISH
D:\NWCLIENT\LSL.COM
D:\NWCLIENT\RL2OEM.COM
IF NOT ERRORLEVEL 1 GOTO CARD_OK
ECHO *
ECHO * ERROR LOADING
ECHO * RL2OEM.COM
ECHO *
PAUSE
:CARD_OK
D:\NWCLIENT\IPXODI.COM
D:\NWCLIENT\VLM.EXE /MX /PS=waldron
JG2050 NET.BAT for LAN WorkPlace
D:\NET\DRIVERS\LSL.COM
D:\NET\DRIVERS\RL2OEM.COM
IF NOT ERRORLEVEL 1 GOTO CARD_OK
ECHO *
ECHO * ERROR LOADING
ECHO * RL2OEM.COM
ECHO *
PAUSE
:CARD_OK
SET NAME=Yourname
BREAK ON
D:\NET\DRIVERS\TCPIP.EXE
A-25
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
JG2050 NET.BAT for FTP Application
C:
CD \
D:\NET\DRIVERS\LSL.COM
D:\NET\DRIVERS\RL2OEM.COM
IF NOT ERRORLEVEL 1 GOTO CARD_OK
ECHO *
ECHO * ERROR LOADING
ECHO * RL2OEM.COM
ECHO *
PAUSE
:CARD_OK
SET PCTCP=C:\PCTCP.INI
BREAK ON
D:\NET\BIN\ODIPKT.COM
D:\NET\BIN\ETHDRV.EXE
D:\NET\BIN\LWPE
About the NET.BAT Parameters
Depending on how you filled in the fields in the Installation Options screen, the
following parameters are added to the NET.BAT file.
Novell User Name The Installation Utility adds the Novellusername to the
LOGIN.EXE command line.
Novell Server Name The Installation Utility adds /PS=Novellservername to the
VLM.EXE command line.
Bindery Emulation If you answer Yes to enable bindery emulation, the
Installation Utility adds /b to the LOGIN.EXE command line.
Preferred Tree If you specify a preferred tree, the Installation Utility adds
/PT=PreferredTree to the VLM.EXE command line.
Unix User Name If you specify a UNIX user name, the Installation Utility adds
set name=UnixUserName.
A-26
Deleted, Modified, and New Files
A
Other Useful Files
Several other files are installed on the JANUS when you run the installation
utility program.
•
APP.BAT calls the network application.
•
GO.BAT can be run from the DOS command line. It reloads the network
drivers, and then calls the application.
•
UNNET.BAT file unloads the radio and network drivers. Unloading the
network drivers is performed to maximize battery life, and to provide the
maximum amount of conventional memory on the JANUS device.
•
IMLOGIN.BAT changes to the network drive and logs in to the NetWare
network.
•
IMLOGOUT.BAT unloads the radio and network drivers and logs out of
the NetWare network
•
UDPPLUS.INI contains the IP address of the Model 200 controller and the
JANUS device.
The following are examples of these files.
APP.BAT for LAN WorkPlace for DOS
@echo off
c:\tnvt 192.9.175.1
c:
cd \
APP.BAT for NetWare Client for DOS
@echo off
call c:\imlogin.bat
c:
cd \
APP.BAT for FTP Application
An APP.BAT file is not automatically generated for FTP. If you are using the
FPT stack, you will need to create this file to call a network application.
A-27
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
GO.BAT for LAN WorkPlace for DOS and FTP Application
@echo off
c:
cd \
call net.bat
call app.bat
call unnet.bat
GO.BAT for NetWare Client for DOS
@echo off
c:
cd \
call net.bat
call imlogin.bat
UNNET.BAT for LAN WorkPlace for DOS
@echo off
d:\net\drivers\tcpip u
d:\net\drivers\rl2oem u
d:\net\drivers\lsl u
UNNET.BAT for NetWare Client for DOS
@echo off
d:\nwclient\vlm u
d:\nwclient\ipxodi u
d:\nwclient\rl2oem u
d:\nwclient\lsl u
A-28
Deleted, Modified, and New Files
A
UNNET.BAT for FTP Application
@echo off
d:\net\bin\lwpe -u
d:\net\bin\inet unload
d:\net\bin\odipkt unl
d:\net\drivers\rl2oem u
d:\net\drivers\lsl u
IMLOGIN.BAT
@ECHO OFF
H:\LOGIN WALDRON/Yourname /B
IMLOGOUT.BAT
@LOGOUT
c:
cd \
if exist unnet.bat call unnet.bat
UDPPLUS.INI
Controller:
Terminal:
192.9.175.5
192.9.175.235
A-29
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
Minimum Files for LAN WorkPlace Installations
Intermec recommends that you install LAN WorkPlace for DOS on a host PC
that does not already have other copies/versions of LAN WorkPlace installed
and perform a full LAN WorkPlace installation. Then, you can use the host PC
with the full copy of LAN WorkPlace as the host PC.
When you install LAN WorkPlace for DOS on a host PC that already has other
copies/versions of LAN WorkPlace, Novell’s LAN WorkPlace installation
procedure may not perform a full installation. If this occurs, this may cause the
Installation Utility to fail. When you specify a LAN WorkPlace installation to
the Installation Utility, it checks for certain files in certain directories and the
existence of the HSTACC directory. For example, if you specify that you are
installing LAN WorkPlace v5.0 and C:\NET as the LAN WorkPlace directory to
for the installation, the Installation Utility verifies that the following paths exist:
C:\NET\BIN\TCPIP.EXE (file)
C:\NET\BIN\LSL.COM (file)
(Or, have C:\NET\BIN\STARTNET.BAT start with path\LSL.COM)
C:\NET\BIN\FTP.EXE (file)
C:\NET\BIN\FTP.MSG (file)
C:\NET\BIN\TNVT220.EXE (file)
C:\NET\BIN\TNVT220.MSG (file)
C:\NET\BIN\LWP.MSG (file)
C:\NET\BIN\TELAPI.EXE (file)
C:\NET\BIN\TELAPI.MSG (file)
C:\NET\BIN\TELSVC.EXE (file)
C:\NET\BIN\TELSVC.MSG (file)
C:\NET\HSTACC\EXTMAP.BIN (file)
C:\NET\HSTACC\HOSTTOPC.MAP (file)
C:\NET\HSTACC\PCTOHOST.MAP (file)
C:\NET\HSTACC\T4_DEF.PAR (file)
C:\TCP\HOSTS (optional file, but will generate message if it does not exist)
C:\TCP\SERVICES (directory)
C:\TCP\NETWORKS (directory)
C:\TCP\PROTOCOL (directory)
A-30
Deleted, Modified, and New Files
A
If you specify that you are installing LAN WorkPlace v4.2 and C:\NET4.2 as
the LAN WorkPlace directory for the installation, the Installation Utility
verifies that the following paths exist:
C:\NET4.2\NWCLIENT\LSL.COM (file)
C:\NET4.2\BIN\TCPIP.EXE (file)
C:\NET4.2\BIN\FTP.EXE (file)
C:\NET4.2\BIN\FTP.MSG (file)
C:\NET4.2\BIN\TNVT220.EXE (file)
C:\NET4.2\BIN\TNVT220.MSG (file)
C:\NET4.2\BIN\LWP.MSG (file)
C:\NET4.2\BIN\TELAPI.EXE (file)
C:\NET4.2\BIN\TELAPI.MSG (file)
C:\NET4.2\HSTACC (directory)
C:\TCP\HOSTS (optional file, but will generate message if it does not exist)
C:\TCP\SERVICES (directory)
C:\TCP\NETWORKS (directory)
C:\TCP\PROTOCOL (directory)
A-31
B
Helpful Information
Helpful Information
B
This appendix explains the login procedures for NetWare servers and describes ARP
table entries for TCP/IP applications. It also provides information for setting a security
ID, for creating or modifying JANUS.INI files, and for configuring multiple JANUS
devices using special batch files.
NetWare Client User Information
If you are a NetWare Client user, you must type IMLOGIN instead of LOGIN
on your JANUS RF device when logging into a NetWare server.
When you reboot your JANUS device, it automatically runs IMLOGIN. You
will usually type IMLOGIN in these situations:
•
You roam out of range of an access point for an extended period of time and
the NetWare server logs your device out. When you return within range of
an access point, you need to type IMLOGIN to log back onto the server.
•
You do not transmit any packets using your device for an extended period
of time. Your device may be placed in a suspend state, and the NetWare
server will log your device out. When you press the button to resume
using the device, you must type IMLOGIN to log back onto the network.
L
ARP Table Entry for TCP/IP Applications
Intermec recommends that you create permanent entries for all your JANUS RF
devices in the ARP (Address Resolution Protocol) table of all the hosts the
devices may communicate with. For help on creating ARP tables, see your
TCP/IP manual.
Note: If the TCP/IP application is running on the device and it initiates an ARP packet
to the host, the ARP packet from the device automatically forces an entry into the ARP
table.
The ARP table maps the IP address to the physical Ethernet address. To make a
permanent entry for your JANUS device in an ARP table, you need to know its
host name (for example, janus1, janus2), or the IP address, along with the
physical Ethernet address of the JANUS device.
During installation, the IP address is entered into a HOSTS file along with the
host names and any aliases.
Example of HOSTS file
192.9.299.154
192.9.200.155
192.9.200.156
192.9.200.157
accesspoint
janus1
janus2
janus3
B-3
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
To find out the physical Ethernet address, also called the node address, for a
JANUS device internal RF card, load the RL2OEM driver (normally executed in
NET.BAT).
Example Showing the Node Address
C:\>rl2pcm
ROM Version V1.41e
Node Type STA, Domain 15
Inactivity Time Out 5 seconds
Sniffing On Standby Is: Enabled
Int 3, Port 360, Mem 0B00,
Node Address 20A6101021 L
Max Frame 1514 bytes,
Board 1, Frame ETHERNET_II, LSB Mode
Board 2, Frame ETHERNET_802.2, LSB Mode
Instructions for making permanent entries into the ARP table are dependent on
the host platform (for example UNIX, DOS, OS/2) and the TCP/IP stack being
used.
For example, if you are using UNIX TCP/IP, you may enter the following
command lines.
> arp -s janus1 00:20:A6:10:10:21
> arp -s janus2 00:20:A6:10:12:CF
> arp -s janus3 00:20:A6:10:12:DC
The first line shows the first entry host name=janus1 with Ethernet
address=00:20:A6:10:10:21.
B-4
Helpful Information
B
Setting the Security ID on Your JANUS RF Devices
As an added security measure, you can set a security ID on all JANUS devices
and access points in a 2.4 GHz RF network. All devices must have the same
security ID to communicate. Setting the security ID is optional. Run this utility
when you have finished configuring each JANUS device.
Use the Security ID Configuration disk to:
•
set or remove a security ID on a JANUS RF device.
•
identify the JANUS device node address.
•
verify that the JANUS device can synchronize with an access point.
There are two ways to run this utility:
•
Connect the JANUS device to a host PC and use Interlnk. The RF setup
utility copies the files to the host PC. Your host PC will need 500KB of free
disk space on drive C. The utility deletes these files when you exit the
program. Follow the procedure to start the utility using Interlnk and then
follow the procedure to set the security ID.
•
Copy the entire contents of the Security ID Configuration disk to an SRAM
card. Follow the procedure to start the utility using an SRAM card and then
follow the procedure to set the security ID.
Note: You need to perform these steps on the JANUS device. You can only see one
section of a PC-size screen on the smaller display of a JG2010 or JG2020. Use the
viewporting feature to move around the screen.
To start the utility using Interlnk
1. Connect your JANUS RF device to the host PC using a null modem cable.
To connect a JG2010 or JG2020, you also need a communications dock or
optical link adapter. Refer to your JANUS user’s manual for more
information.
2. Insert the Security ID Configuration disk in drive A on the host PC.
3. At the DOS prompt on the host PC, type this command and press Enter.
a:rfsetup
Note: If the optical link adapter supports the baud rate set to 115200, at the DOS
prompt, type rfsetup /h.
The utility copies the files from the disk to the drive C on the host PC.
><A
4. Press any key on the host PC keyboard.
5. Reboot the JANUS device by pressing
.
B-5
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
To start the utility using an SRAM card
1. Insert the Security ID Configuration disk in drive A on the host PC.
2. Insert a formatted SRAM card into a PCMCIA (PC) drive on the host PC.
3. At the DOS prompt, type this command and press Enter.
a:sramset drive
><A
where drive is the drive letter of the PC drive on the host PC.
4. Reboot the JANUS device by pressing
Note: You can press
?
.
to skip the memory test and save time.
@
On the JANUS screen, when you see the MS-DOS 6.2 Startup screen, choose
and press
.
5. On the JANUS device, this prompt appears.
@
&A%
@
2$"(#
@
Network?
Type
6. Type
7. Type
B-6
and press
.
and press
.
and press
.
Helpful Information
To set the security ID
1. On the JANUS device, choose the Test/Utilities button and press
2. Press
AM
(tab) to choose the Security ID button and press
@
B
@
.
.
B-7
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
3. A warning message about the security ID option appears
Warning: AccessNet cards communicate only with other AccessNet
cards with the same Security ID. Be sure to set the Security
ID on all AccessNet cards in the same subnetwork to the same
value.
Press
@
@
to choose the Continue button.
4. Enter the security ID and press
. You can use up to 20 alphanumeric
characters. The security ID is case-sensitive.
Or, delete the security ID if you no longer want to use this feature.
5. A message informs you that your security ID has been updated.
@
Your AccessNet security ID has been updated.
Press
B-8
to continue.
Helpful Information
B
6. A message informs you that the operation was successful. The message box
also informs you of the JANUS device node address.
If you are not within range of an access point with the security ID set, you
can ignore the message that the JANUS device could not find a Master to
synchronize with.
However, if you are within range of an access point and the security ID is
correct, the message box informs you that the JANUS device is
synchronized to the access point and provides the node address of the
access point. For example:
AM
AM
Synchronized to 0020a63051df
7. Press
8. Press
@
@
(tab) to choose the Done button and press
(tab) to select the Exit button and press
.
.
9. On the host PC, press Alt-F4 to exit Interlnk. The utility deletes the files it
copied to drive C.
If you installed terminal emulation software on the JANUS device, it will try to
start a session with the host.
B-9
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
Customizing the J24TE.INI File
For Intermec terminal emulation installations, the J24TE.INI file is copied from
the TE Applications disk to a subdirectory on your host PC. You may want to
customize the J24TE.INI file to permanently change your JANUS operating
environment. You can customize the J24TE.INI file to enable or disable
supported symbologies or to change other operating parameters such as beep
volume, display, viewport size and movement.
To customize the J24TE.INI file
1. Shell out to DOS during the installation process.
2. Type the following command from a DOS prompt on the host PC to start
Intersvr on the host.
a:intersvr
3. After Intersvr is running, remove the Installation Utility disk from drive A.
Note: Drive A must be empty or this process will not work.
><A
4. Reboot the JANUS device by pressing
. When the JANUS
device boots, the Microsoft Interlnk Server Version Intermec menu appears
along with the server/client drive mapping screen.
Note: If you do not reboot the JANUS device while Intersvr is running on the host
PC, Interlnk will not load on the JANUS device and you will not be able to access
the drives on the host PC.
("
5. At the JANUS DOS prompt, type
configuration application (IC.EXE).
and press
@
@
@
to start the
6. Select the LOAD option from the File menu.
7. Select the IM_FLASH\ directory and press
@
8. Select the DRIVEC\ directory and press
9. Select J24TE.INI and press
.
.
.
10. Use IC.EXE to make your configuration changes. See your JANUS user’s
manual for more information on IC.EXE.
B-10
Helpful Information
11. Select SAVE from the File menu and press
@
B
.
Note: You can omit steps 8-11 if you can type X:\IM_FLASH\DRIVEC\J24TE.INI at
the NAME prompt and save the file. Where X is the drive letter on the host PC that
you are mapping to.
12. Select EXIT from the File menu.
13. Select No when you are prompted to update the online configuration on the
JANUS device.
14. Reinsert the Installation Utility disk in drive A on the host PC.
$7(3
15. Press Alt-F4 on the host PC to exit Intersvr.
16. Type
at the DOS prompt on the JANUS device and press
You can now continue with the installation.
@
.
Creating a JANUS.INI File
For Novell TNVTxxx and NetWare Client for DOS installations, you may want
to create a JANUS.INI file to permanently change your JANUS operating
environment. You can use a JANUS.INI file to enable or disable supported
symbologies or to change other operating parameters such as beep volume,
display, viewport size and movement.
To create a JANUS.INI file
1. Shell out to DOS during the installation process.
2. On the host PC , edit the \IM_FLASH\DRIVEC\AUTOEXEC.BAT file to
change:
d:\ic /l e:\janus.ini
to
d:\ic /l c:\janus.ini
3. Save the changed AUTOEXEC.BAT file.
4. At the DOS prompt on the host PC, type this command to start Intersvr.
a:intersvr
5. After Intersvr is running, remove the Installation Utility disk from drive A.
Note: Drive A must be empty or this process will not work.
B-11
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
><A
6. Reboot the JANUS device by pressing
. When the JANUS
device boots, the Microsoft Interlnk Server Version Intermec menu is
displayed along with the server/client drive mapping screen.
Note: If you do not reboot the JANUS device while Intersvr is running on the host
PC, Interlnk will not load on the JANUS device and you will not be able to access
the drives on the host PC.
("
7. At the JANUS DOS prompt, type
configuration application (IC.EXE).
and press
@
to start the
8. Use IC.EXE to make your configuration changes. See your JANUS user’s
manual for more information on IC.EXE.
9. Select the SAVE AS option from the File menu. Type the drive letter on the
host PC that you are mapping to (refer to the server/client drive mapping
screen) and
at the NAME prompt and press
.
O(-(
@
@
10. Select the IM_FLASH\ directory and press
11. Select the DRIVEC\ directory and press
.
@
.
@
12. Save the configuration you created as JANUS.INI and press
. You are
saving the .INI file you created using the configuration application to the
drive on the host PC where the JANUS drive C image will be built. This file
is written to the JANUS flash memory and becomes a permanent part of
your configuration.
Note: You can omit steps 9-12 if you type X:\IM_FLASH\DRIVEC\JANUS.INI at the
NAME prompt and save the file. Where X is the drive letter on the host PC that
you are mapping to.
13. Select EXIT from the File menu.
14. Select No when you are prompted to update the online configuration on the
JANUS device.
15. Reinsert the Installation Utility disk in drive A on the host PC.
$7(3
16. Press Alt-F4 on the host PC to exit Intersvr.
17. Type
at the DOS prompt on the JANUS device and press
You can now continue with the installation.
B-12
@
.
Helpful Information
B
Configuring Multiple JANUS RF Devices Using Batch Files
The Installation Utility disk contains five batch files that can help you easily
configure multiple JANUS devices if you have exited the Installation Utility.
You can quickly edit a file in the DRIVEC or DRIVED subdirectory and then
use the batch files to create the JANUS drive image and download it.
These batch files exist after you have run the Installation Utility once AND you
have saved your files that were created by a previous install. That is, during the
first install, you need to choose N when prompted with this question:
Do you want to delete the files created by the install? (Y/N)
When the files created by the install are saved, the applicable batch files are also
copied from the Installation Utility disk to the \IM_FLASH directory. If you
performed a complete installation, that is if you did not use any switches after
you typed the pcsetup command, all batch files are copied to this directory. If
you used the /drivec or /drived switch, only the applicable batch files are
copied.
MKC.BAT Creates the JANUS drive C image on the host PC from the files in
the \IM_FLASH\DRIVEC directory.
LOADC.BAT
device.
Downloads the JANUS drive C image to the connected JANUS
MKD.BAT Creates the JANUS drive D image on the host PC from the files in
the \IM_FLASH\DRIVED directory.
LOADD.BAT
device.
Downloads the JANUS drive D image to the connected JANUS
LOADALL.BAT Downloads the JANUS drive C image, drive D image, and the
system images to the connected JANUS device.
To create and download a modified drive C image
1. Make any changes to the files in the \IM_FLASH\DRIVEC directory.
2. Connect your JANUS RF device to the host PC using a null modem cable.
To connect a JG2010 or JG2020, you also need a communications dock or
optical link adapter. Refer to your JANUS user’s manual for more
information.
3. On the host PC, go to the \IM_FLASH directory.
4. On the host PC, type mkc and press Enter. The batch file runs the JANUS
drive image builder utility and creates the binary image file
\IM_FLASH\DRIVE_C.IMG.
B-13
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
L
IB
L
5. On the JANUS device, use these steps to bring up the Boot Loader menu.
a. Press
b. Press
c. Press
d. Press
to place the JANUS device in a suspend state.
.
.
to turn the JANUS device on again.
6. From the Boot Loader menu, select LOAD and press
@
.
7. On the host PC, type loadc and press Enter.
The Janus 2000 Flash Loader screen appears and downloads the modified
JANUS drive C image to the connected JANUS device.
To create and download a modified drive D image
1. Make any changes to the files in the \IM_FLASH\DRIVED directory.
2. Connect your JANUS RF device to the host PC using a null modem cable.
To connect a JG2010 or JG2020, you also need a communications dock or
optical link adapter. Refer to your JANUS user’s manual for more
information.
3. On the host PC, go to the \IM_FLASH directory.
4. On the host PC, type mkd and press Enter. The batch file runs the JANUS
drive image builder utility and creates the binary image file
\IM_FLASH\DRIVE_D.IMG.
L
IB
L
5. On the JANUS device, use these steps to bring up the Boot Loader menu.
a. Press
b. Press
c. Press
d. Press
to place the JANUS device in a suspend state.
.
.
to turn the JANUS device on again.
6. From the Boot Loader menu, select LOAD and press
@
.
7. On the host PC, type loadd and press Enter.
The Janus 2000 Flash Loader screen appears and downloads the modified
JANUS drive D image to the connected JANUS device.
To create and download modified drive C and drive D images
1. Make any changes to the files in the \IM_FLASH\DRIVEC directory.
2. Connect your JANUS RF device to the host PC using a null modem cable.
To connect a JG2010 or JG2020, you also need a communications dock or
optical link adapter. Refer to your JANUS user’s manual for more
information.
B-14
Helpful Information
B
3. On the host PC, go to the \IM_FLASH directory.
4. On the host PC, type mkc and press Enter. The batch file runs the JANUS
drive image builder utility and creates the binary image file
\IM_FLASH\DRIVE_C.IMG.
5. Make any changes to the files in the \IM_FLASH\DRIVED directory.
6. On the host PC, type mkd and press Enter. The batch file runs the JANUS
drive image builder utility and creates the binary image file
\IM_FLASH\DRIVE_D.IMG.
7. Verify that the \IM_FLASH directory contains a file systemx.xxx where
x.xxx is the version of a valid unarchived JANUS system image.
L
IB
L
8. On the JANUS device, use these steps to bring up the Boot Loader menu.
a. Press
b. Press
c. Press
d. Press
to place the JANUS device in a suspend state.
.
.
to turn the JANUS device on again.
9. From the Boot Loader menu, select LOAD and press
@
.
10. Type loadall and press Enter.
The Janus 2000 Flash Loader screen appears and downloads the modified
JANUS drive D image, drive C image, and system image to the connected
JANUS device.
B-15
G
Glossary
Glossary
G
This glossary contains definitions for terms specific to this manual and the Novell
software network user environment.
Access Point
Intermec’s wireless bridge that allows RF packets to go from an Intermec 2.4
GHz RF network to Token Ring or Ethernet network.
alphanumeric
Character set containing letters, numbers, and other characters, such as
punctuation marks.
API (application programming interface)
A set of routines that an application program uses to request and carry out
lower-level services performed by a computer’s operating system.
bandwidth
The size in Hertz of the frequency range that a signal transmission occupies.
Typical narrow band signals occupy a 25 KHz bandwidth. The 2.4 GHz radio
frequency signal occupies a 1 MHz bandwidth.
bindery emulation
NetWare 4.0 feature that lets you emulate the bindery database system that was
available in all previous versions.
BOOTP (Bootstrap Protocol) server
A device that assigns an IP address in response to a query from an IP node. In
this query, the IP node supplies its physical address. The BOOTP server then
checks its tables to determine the corresponding IP address.
bridge
An internetworking device connects two LAN segments at the data link layer
of the OSI model
broadcast
A type of transmission in which a message sent from the host is received by all
devices on the system.
buffer
An area of storage used to hold data being transferred from one device to
another.
G-3
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
channel
The path for transmitting data from a device to the host computer. In RF
networks, it is the frequency hopping sequence the card follows. The 2.4 GHz
bandwidth can be divided into 15 different channels.
controller
An electronic device that interfaces between the data collection devices and the
system computer.
CSMA/CD (Carrier Sense Multiple Access/Collision Detection)
CSMA is a protocol in which each node senses whether or not a channel is in
use before attempting to transmit information. CD is an algorithm by which
channel time is reserved to avoid collisions.
data collection device
A device used with a scanner to collect data from scanned bar codes and send it
to a host computer.
data transmission
An event in which a block of data is transmitted from one device to another.
device
Any physical item that is attached to a computer. A terminal, a printer, a
reader, and a controller are all devices.
device address
A type of address that is used by the host to identify a particular data collection
device.
domain
The area within a LAN that defines a region administered by a controller or
server. The domain is also called a subnetwork.
driver
A software module that controls an input/output port or external device.
Ethernet
A type of LAN that allows the transmission of computer data, audio data, and
video data. Ethernet uses the access method known as Carrier Sense Multiple
Access with Collision Detection (CSMA/CD). See IEEE 802.3 standard for the
specifications.
G-4
Glossary
G
frequency hopping
A spread spectrum technique by which the band is divided into a number of
channels and the transmissions hop from channel to channel in a prespecified
sequence.
hand-held scanner
A scanner held and operated by a human. The scanner is moved to the object to
be scanned, instead of moving the object close to the scanner.
host computer
If several computers are connected together on a network, the controlling
computer is the host computer. A host computer can be a desktop, laptop, or
notebook PC.
HOSTS file
A database that contains a list of remote hosts’ IP addresses and their logical
names (aliases) that any device on the network can reach.
interference
A situation that occurs when an unwanted RF signal occupies the same
frequency band as a desired signal.
IP (Internet Protocol)
This protocol provides a method for transmitting blocks of data (IP datagrams)
between hosts.
IP address
This address is a network level address assigned to each device in a TCP/IP
network.
IPX (Internet Packet eXchange)
This protocol provides a means for message packets to be exchanged on an
internetwork.
LAN (Local Area Network)
A group of intelligent workstations that are hooked together to allow them to
share data, printers, and other devices. LANs are usually used over a small
geographic area.
LSL (Link Support Layer)
This layer serves as an intermediary between ODI and the link driver that
supplies an interface between the network board and the rest of the operating
system.
G-5
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
network
A collection of devices that can store and manipulate electronic data,
interconnected in such a way that its users can store, retrieve, and share
information with each other.
network node
An end point in a network to which or from which you can route data. Usually
this is a workstation or host computer.
Novell user name
This parameter identifies the user to the Novell software running on a remote
host.
operating system
Refers to the code that operates a computer by managing its file systems,
handling user input and output, and running programs. DOS, Windows, and
UNIX are all operating systems.
OSI model
Open Systems Interconnection reference model. A framework developed by the
International Standards Organization (ISO) to provide worldwide standards for
computer communications.
packet
The unit of information by which the network communicates. A packet consists
of a single network message with its associated header, addressing information,
data, and optional trailer. A packet can also be called a frame or datagram.
port
The physical place where devices connect to each other for communication
purposes.
preferred tree
The tree you specify that you first want to connect to in a NetWare 4.X network
if you have multiple trees. If this tree has a server with a free connection, the
NetWare DOS Requester attaches to it.
protocol stack
A group of drivers that work together to span the layers in the network
protocol hierarchy.
G-6
Glossary
G
RAM (Random Access Memory)
A memory that can be written into, or read, by locating any data address. A
device that permits individual interrogation of any memory cell in a completely
random sequence.
RFDC system
This term (radio frequency data collection system) refers to a data collection
system in which the individual components communicate with each other by
radio signals.
router
A software and hardware connection between two or more networks that
permits traffic to be routed from one network to another on the basis of the
intended destinations of that traffic.
scratch drive
The physical hard drive that you use to build the JANUS device’s drive images.
serial
A communications scheme in which the bits of a byte are transferred one at a
time. Often serial transmission is used to link host computers to terminals and
PCs to printers.
server
A computer that is configured to provide services to the network.
shell out feature
This feature allows you to go to the DOS command line without exiting the
Installation Utility.
spread spectrum
A radio data transmission modulation technique by which the transmitted
signal is spread over a bandwidth wider than the information bandwidth.
SNMP (Simple Network Management Protocol)
A protocol used to manage network activity.
SPX (Sequenced Packet eXchange)
This protocol provides a method for two workstations or applications to
communicate across the network. SPX works with IPX to deliver the messages.
However, SPX guarantees the delivery of the messages and maintains the order
of messages on the packet stream.
G-7
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
subnet mask
This mask is used in the IP protocol to differentiate between the subnet address
and the host address.
subnetwork
A section of a large network that functions as an independent network, but
does not appear separate to remote networks.
TCP (Transport Control Protocol)
This protocol provides a method for creating a connection-oriented, reliable,
error-free, full-duplex, byte-stream communication between two processes. See
also IP.
UNIX user name
This parameter is a variable in the DOS environment. The UNIX user name
identifies the user to the Novell software running on a remote host.
UDP
User datagram protocol. UDP is an alternative to TCP. This protocol is the
Internet standard for wireless devices. You can use UDP when you do not need
a guaranteed delivery. You can also use UDP when you do not require all of the
services of TCP.
UDP Plus
This Intermec-designed protocol is based on UDP. UDP Plus improves the
performance of devices in a mobile wireless environment. Intermec uses this
protocol to communicate with the Model 200 Controller.
G-8
I
Index
Index
Numbers
2.4 GHz RF network, figure, 1-4
A
Access Point, definition, G-3
access points
identifying node address, B-9
synchronizing with JANUS devices, B-5, B-9
AccessNet/ISA Setup screen, B-7
adding your data collection application, 2-12
alphanumeric, definition, G-3
API, definition, G-3
APP.BAT file
FTP Application, A-27
LAN WorkPlace, A-27
NetWare Client, A-27
application programming interface, See API
application, installing on the JANUS device, A-3
ARP table, creating entries for TCP/IP applications, B-3
AUTOEXEC.BAT file, printout, A-10, A-12, A-14
B
backup copy, making, 1-7
bandwidth, definition, G-3
batch files
LOADALL.BAT, B-13
LOADC.BAT, B-13
LOADD.BAT, B-13
MKC.BAT, B-13
MKD.BAT, B-13
using to modify drive images, B-13
battery life, optimizing, 2-10
baud rate, selecting, 3-8
bindery emulation
definition, G-3
in NET.BAT, A-26
Bindery Emulation field, 2-8
Boot Loader menu, accessing, 3-9
BOOTP server, definition, G-3
bootstrap protocol server, See BOOTP server
bridge, definition, G-3
broadcast, definition, G-3
buffer, definition, G-3
building drive images, 1-6
C
carrier sense multiple access/collision detection, See
CSMA/CD
cautions, explanation of, ix
Channel field, 2-11
channel, definition, G-4
character set, choosing, 2-5
Choose a Character Set screen, 2-5, 3-4
I
choosing the configuration parameters, 3-3
COM port, selecting, 3-9
command format conventions, xi
CONFIG.SYS file
printout, A-4, A-6, A-8
configuration parameters
choosing, 3-3
understanding, 2-4
configuring multiple JANUS devices, 2-13, 3-10
controller, definition, G-4
conventional memory, for international character sets,
2-6
creating a HOSTS file, 2-3
creating a JANUS.INI file, 2-12, B-11
creating the NET.CFG file
JG2010, A-16
JG2020, A-17
JG2050, A-18
CSMA/CD, definition, G-4
customizing the J24TE.INI file, 2-12, B-10
D
data collection application, adding, 2-12
data collection device, definition, G-4
data transmission, definition, G-4
default router, in NET.CFG, A-20
Default Router field, 2-7, 2-9
device address, definition, G-4
device, definition, G-4
domain, 2-10
definition, G-4
Domain field, 2-11
downloading new drive images, 1-6
downloading the modified drive images, 3-8
drive A, error messages, 4-8
drive C
files conditionally removed, A-4
files removed, A-3
drive D, files removed, A-3
drive images
building, 1-6
building drive C, 1-5
building drive D, 1-5
downloading, 1-6, 3-8
modifying, 1-5, 3-7
using batch files to modify, B-13
Drive to build flash images field, 2-7, 2-8, 2-9
DRIVEC
creating drive C image, 1-6
deleting files, 2-13
modifying contents, 3-7
DRIVEC subdirectory, 1-5
DRIVECX subdirectory, 1-5
DRIVED subdirectory, 1-6
DRIVED, modifying contents, A-3
I-3
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
DRIVEDX subdirectory, 1-6
drivers
definition, G-4
radio, 1-6
radio power management, 1-6
E
error messages
drive A, 4-8
troubleshooting, 4-4, 4-8
Ethernet
address, B-4
definition, G-4
F
F1 key, using to get help, 1-8
features, 1-3
frequency hopping, definition, G-5
FTP PC/TCP for DOS
configuring, 2-9
G
GO.BAT file
LAN WorkPlace, A-28
NetWare Client, A-28
H
hand-held scanner, definition, G-5
help, using the F1 key, 1-8
host computer, definition, G-5
Host IP Address field, 2-7
Host Name field, 2-7
host PC
requirements, 1-7
restoring to default configuration, 3-11
setting up, 2-3
HOSTS file
creating, 2-3
definition, G-5
diagnostic messages, 2-3
example, 2-3
IP address entries, B-3
I
IMLOGIN, B-3
IMLOGIN.BAT file, A-29
IMLOGOUT.BAT file, A-29
inactivity minutes, 2-10
Inactivity Minutes field, 2-11
inactivity seconds, 2-10
Inactivity Seconds field, 2-12
Installation and Configuration Tasks screen, 3-7
Installation Options screen, 3-10
Bindery Emulation field, 2-8
I-4
Default Router field, 2-7, 2-9
Drive to build flash images field, 2-7, 2-8, 2-9
FTP PC/TCP for DOS, 2-9
Host IP Address field, 2-7
Host Name field, 2-7
LAN WorkPlace for DOS, 2-6, 2-7
Name Context, 2-8
NetWare Client for DOS, 2-6, 2-8
Novell Server Name field, 2-8
Novell User Name field, 2-8
Path to Installation field, 2-7, 2-8, 2-9
Preferred Tree field, 2-8
Station IP Address field, 2-7, 2-9
Subnet Mask field, 2-7, 2-9
UNIX User Name field, 2-7, 2-9
Version field, 2-7, 2-8
Installation Utility
features, 1-3
kit contents, 1-3
overview, 1-4
installation, files removed, A-3
interference, definition, G-5
Intermec 3270/5250 emulation, 2-5
Intermec TNVTxxxx emulation, 2-4
internet packet exchange, See IPX
internet protocol, See IP
IP address
definition, G-5
in NET.CFG, A-20
IP, definition, G-5
IPX, definition, G-5
J
J24TE.INI file, customizing, 2-12, B-10
Janus 2000 Flash Loader screen, 3-9
JANUS devices
configuring multiple devices, B-13
configuring next device, 2-13, 3-10
conventional memory required, 2-6
downloading modified drive image, 3-8
setting the security ID, B-5
switching between keypads, 2-6
synchronizing with access points, B-9
synchronizing with an access point, B-5
JANUS files
deleted from drive C, 1-5
deleted from drive D, 1-6
JANUS.INI file, creating, 2-12, B-11
JG2010 NET.BAT file
FTP Application, A-23
LAN WorkPlace, A-22
NetWare Client, A-22
Index
JG2020 NET.BAT file
FTP Application, A-24
LAN WorkPlace, A-24
NetWare Client, A-23
JG2050 NET.BAT file
FTP Application, A-26
LAN WorkPlace, A-25
NetWare Client, A-25
K
keyboard format conventions, xi
keypads, switching, 2-6
L
LAN WorkPlace for DOS, 2-7, 3-6
configuring, 2-7
minimum required files, A-30
LAN, definition, G-5
link support layer, See LSL
LOADALL.BAT file, B-13
LOADC.BAT file, B-13
LOADD.BAT file, B-13
local area network, See LAN
LSL, definition, G-5
M
making a backup copy, 1-7
manual
format conventions for commands, xi
format conventions for input, xi
related, xii
summary, x
Master Name field, 2-11
MINIPM.EXE driver, 1-6
MKC.BAT file, B-13
MKD.BAT file, B-13
modifying the AUTOEXEC.BAT file
JG2010, A-10
JG2020, A-12
JG2050, A-14
modifying the CONFIG.SYS file
JG2010, A-4
JG2020, A-6
JG2050, A-8
MS-DOS 6.2 Startup screen, B-6
N
Name Context field, 2-8
navigating within screens, 1-8
NET.BAT file
parameters, A-26
NET.CFG file
creating
JG2010, A-16
I
JG2020, A-17
JG2050, A-18
parameters, A-20
NetWare Client for DOS, 2-5, 2-8, 3-6
configuring, 2-8
creating a JANUS.INI file, B-11
using IMLOGIN, B-3
network node, definition, G-6
network parameters, understanding, 2-6
network, definition, G-6
node address, See also Ethernet address
identifying on access point, B-9
notes, explanation of, ix
Novell Server Name field, 2-8
Novell server name, in NET.BAT, A-26
Novell TNVTxxx emulation, 2-5
Novell TNVTxxx installations, creating a JANUS.INI file,
B-11
Novell User Name field, 2-8
Novell user name, definition, G-6
Novell user name, in NET.BAT, A-26
O
operating system, definition, G-6
OSI model, definition, G-6
overview of the Installation Utility, 1-4
P
packet, definition, G-6
parameters, network, See network parameters
parameters, radio, See radio parameters
parameters, understanding, 2-4
Path to Installation field, 2-7, 2-8, 2-9
PCTCP.INI File, A-20
phone number, ii
port, definition, G-6
preferred tree
in NET.BAT, A-26
Preferred Tree field, 2-8
preferred tree, definition, G-6
protocol stack, definition, G-6
R
radio driver, 1-6
Radio Parameters screen, 2-10, 3-7, 3-10
Channel field, 2-11
Domain field, 2-11
Inactivity Minutes field, 2-11
Inactivity Seconds field, 2-12
Master Name field, 2-11
Station Type field, 2-11
Subchannel field, 2-11
Wake Up on Broadcast field, 2-12
radio parameters, understanding, 2-10
I-5
JANUS 2.4 GHz Installation Utility User’s Manual (4MB)
radio power management driver, 1-6
RAM drive directory
copying Novell network software to, 1-5
creating drive D image, 1-6
for LAN WorkPlace for DOS, 1-6
for NetWare Client for DOS, 1-5
modifying contents, 3-7, A-3
RAM, definition, G-7
random access memory, See RAM
RARP server, A-20
reducing files
DRIVEC, 2-13
requirements
host PC, 1-7
system, 1-7
restoring the host PC, 3-11
RFDC system, definition, G-7
RL2OEM.COM driver, 1-6
router, definition, G-7
S
scratch drive
copying Novell network software to, 1-5
definition, G-7
screens
Choose a Character Set, 2-5, 3-4
Installation Options, 2-7, 2-8
moving around in, 1-8
Radio Parameters, 2-10, 3-7
Select a Network/Protocol, 3-3
security ID
setting on JANUS devices, B-5
setting using an SRAM card, B-5, B-6
setting using Interlnk, B-5
Security ID Configuration disk, 1-3, B-5
Select a Network/Protocol screen, 3-3, 3-10
sequenced packet exchange, See SPX
serial, definition, G-7
server, definition, G-7
setting the security ID, B-5
setting up the host PC, 2-3
shell out feature, 1-5, 2-12, 3-10, A-3
definition, G-7
using, 3-7
simple network management protocol, See SNMP
SNMP, definition, G-7
spacebar, using to toggle fields, 1-8
spread spectrum, definition, G-7
SPX, definition, G-7
SRAM card, using to set security ID, B-6
Station IP Address field, 2-7, 2-9
station type, 2-10
alternate master, 2-11
master, 2-11
station, 2-11
I-6
Station Type field, 2-11
Subchannel field, 2-11
subnet mask
definition, G-8
in NET.CFG, A-20
Subnet Mask field, 2-7, 2-9
subnetwork, See also domain definition, G-8
system requirements, 1-7
T
TCP, ARP table entries, B-3
TCP, definition, G-8
technical support, phone number, ii
terminal emulation software, installing, 2-4
terminal emulation, customizing the J24TE.INI file, B-10
toggle fields, spacebar, 1-8
transmission control protocol, See TCP
troubleshooting
drive A error messages, 4-8
error messages, 4-4
general problems, 4-3
U
UDP Plus, definition, G-8
UDP, definition, G-8
UDPPLUS.INI file, A-29
understanding network parameters, 2-6
understanding radio parameters, 2-10
UNIX User Name
definition, G-8
field, 2-7
in NET.BAT, A-26
UNNET.BAT file
FTP Application, A-29
LAN WorkPlace, A-28
NetWare Client, A-28
using the shell out feature, 3-7
Utilities screen, B-7
V
Version field, 2-7, 2-8
W
Wake Up on Broadcast field, 2-12

advertisement

Related manuals

Download PDF

advertisement