- Sports & recreation
- Camping, tourism & outdoor
- Above ground pools
- Above ground pool accessories
- User manual
advertisement
▼
Scroll to page 2
of
91
INSTALLATION MANUAL MANUEL D’INSTALLATION MANUAL DE INSTALACIÓN SUN & CONFORT (37059, 37060) ENGLISH Thank you for purchasing an AstraPool swimming pool immersion detection system. This swimming pool immersion detector is compliant with French standard NF P90-307/A1. WARNINGS This alarm system is not a replacement for common sense or individual responsibility. Its purpose is not to be a replacement for vigilance by a parent or responsible adult, which remains the vital factor in protecting children under the age of 5. This alarm is a protective device which signals a danger (or danger risk). A responsible adult must take quick action within 3 minutes of the sounding of the alarm signal. By responsible adult, we mean an adult who knows how to take account of the danger, knows how to swim, and is capable of rescuing someone in the pool. In no event can your retailer or the manufacturer of the alarm system be held responsible for any person or animal falling or drowning. In no event must the installation of your alarm system reduce your vigilance or replace active monitoring of the swimming pool and the area around it. You must always check that the alarm can be heard from the residence/living quarters. Depending on the layout of the residence/living quarters in relation to the swimming pool, it may be necessary to move the safety, alarm and failure signals so they can be heard from the dwelling/living quarters. This must be checked during installation. Should it be necessary to complement your immersion detector with a remote siren, you should install a Remota™ remote sound alarm. CONTACT YOUR RETAILER FOR ADVICE Regularly check the water level in your pool, especially when the weather is very hot, or rainy, or if it has been windy for several days. To ensure proper operation of your immersion detector, the immersion level must imperatively be 15cm (+/– 3cm). If you do not follow these instructions your immersion detector will not work properly. Place permanent signs to inform people that the pool and the area around it are monitored electronically. The magnets must be kept out of the reach of children. The performance as defined in standard NF P90-307/A1 is not guaranteed beyond wind levels greater than those specified in this standard. 1 This guide allows you to: I Understand the operating principle of your immersion detection system; I Position and fasten your immersion detection system according to the characteristics of your swimming pool; I Perform regular operation tests on your immersion detection system. FILL OUT, SIGN and SEND the TEST VALIDATION SHEET by mail to AstralPool within 7 days after your purchase, at the following address: AstralPool SAU Avda Francesc Macia, 38 Planta 18 08208 Sabadell – Spain In case of negligence or non-receipt of the test validation sheet, the warranty related to your Sun™/Confort™ alarm system cannot be applied (if it is missing from the packaging, immediately inform your reseller). 1. Contents of the package Despite the careful attention we pay to the quality of our products and their packaging, you are requested to check the contents of the package, depending on the type of your immersion detector. COMPONENTS 1 central unit with its black flexible tube, and for Confort , the T° probe and the pH probe (Warning! the black flexible tube and the ConfortTM probes are connected to the central unit, take care not to pull on them) SUN™ CONFORT™ • • • • • • • • - • • • • • • • • • TM 1 rigid tube 1 7V lithium battery 1 fastening kit (screws, washers, joints, rawplugs, 2 magnet key-rings) 1 test validation sheet for the warranty (included in these instructions) 1 conformity declaration sheet The terms of warranty at the end of this guide 1 Remota™ remote siren 1 pH calibration kit (ConfortTM) 2 2. Operating principle How does Sun™ / Confort™ work? Thanks to its on-board technology, your immersion detector continuously monitors the condition of the pool. In case of a fall into your swimming pool, your immersion detector sets off its siren in accordance with the requirements of French standard NF P90-307/A1. You must deactivate the surveillance of your immersion detector before having a swim. (see item 4.1) After your swim, your immersion detector automatically resumes monitoring of the pool as soon as it has become still again. (see item 4.2) The new Sun™/Confort™ technology includes a pool continuous analysis system. Sun™/Confort™ Signal principles: SIGNAL STATUS ACTION VISUAL (at the rear of the device) Your immersion detector is monitoring When moving the magnet over the swimmer symbol: 1 long high-pitched beep indicator light off Your immersion detector is not monitoring When moving the magnet over the swimmer symbol: 10 short high-pitched beeps flash at two-second intervals Your immersion detector is off Your immersion detector is leaving the TEST mode Low battery When moving the 2 magnets (swimmer symbol and red stop sign): 10 short high-pitched beeps (see item 4.6) Specific tune (see item 4.5) 4 short low-pitched beeps every time the magnet is moved 1 short, low-pitched beep every minute 3 ... ... ............... flash once a minute _ _ 3. Installation of Sun™ / Confort™ INSTALLATION PRECAUTIONS YOUR IMMERSION DETECTOR MUST BE INSTALLED IN GOOD WEATHER ON A STILL POOL. The alarm system must be installed at a location where the pool is at least 30 cm deep. Make sure that the water in your pool is clear and pure before installing your device. DO NOT USE AN ELECTRIC SCREWDRIVER when installing your device. Some robot cleaners like diving robot are incompatible with immersion detection systems. Your immersion detector is installed in 7 steps: 3.1 Attachment of the rigid tube 3.2 Insertion of the batteries 3.3 Choice of location 3.4 Temporary installation 3.5 Installation tests 3.6 Final installation 3.7 Validation tests UTMOST VIGILANCE IS REQUIRED FROM THE PARENT/RESPONSIBLE ADULT DURING THE INSTALLATION OF YOUR IMMERSION DETECTOR Tools required for installation: 1 Phillips screwdriver 1 tape measure I Four 1.5L water bottles I 1 roll of adhesive tape I 1 rope about 2 meters long. I 1 drill with concrete bit Ø8 mm I 1 hacksaw I 1 pair of shears or heavy-duty scissors I 1 pencil I One 15 mm spanner for Confort™ I I 4 3.1. Attachment of the rigid tube 1 rigid tube 2 flexible tube temperature probe pH probe pH and temperature probes present only on ConfortTM. Insert the temperature probe and the flexible tube into the main compartment of the rigid tube. Be careful about the way the rigid tube is set up. 3 4 xx22 Carefully insert the rigid tube to a sufficient depth (about 3 cm). Screw the 2 self-drilling screws (provided with the fastening kit). 5 Set the pH probe at the location indicated, the probe is held in place by the two black rings. 3.2. Inserting the batteries 2 1 Insert the lithium battery in the housing provided in front of the PCB. Unscrew the 4 screws and remove the cover. 5 3 4 LITHIUM BATTERY Connect the lithium battery to the PCB. Validation sound signal (1 long beep followed by 10 short beeps). Your device is in inactive monitoring (red flashes from the indicator light at the rear of the device). Put the cover back in place without tightening the screws. SunTM and ConfortTM have a system which comes in the form of several small parallel switches. You must on no account change the settings of these switches. Be sure to check the settings of these switches (ON or OFF), the combination must be as follows: 1 on ON 2 on OFF 3 on ON 4 on ON 5 on ON ON OFF 3.3. Choice of location Your fall detector must be positioned in the center of the greatest length of your swimming pool, on a coping (position recommended for rectangular swimming pools). If your pool does not correspond to the configurations shown below, ask your retailer for advice. Ensure that the central unit is more than one meter away from the filtration system (return fittings, waste plug, skimmer, vacuum fittings, etc.) or waterfall or any other device that may disturb the pool at this place. Your immersion detector is designed and configured in compliance with standard NF P90-307/A1, and can be used on pools with maximum dimensions of 10 x 5 meters. Your immersion detector must not be more than 7 meters away from all possible fall locations. For a larger swimming pool, several immersion detectors must be installed. Contact your retailer for advice. In the case of a pool of a particular shape, contact your retailer for advice. 6 7m maximum Either location Either location I Examples of positioning of your central unit. Check that there is easy and practical access to the activation zone (where you place the magnet). The probe must be immersed by 15 cm (± 3cm) to ensure optimum operation. If the water level has been deliberately lowered, suitable probe extenders are available from your retailer. 15cm (±3cm) The water level must be checked regularly, and must be restored if required to maintain an immersion depth of 15 cm (+/- 3cm). The installation of a level controller is recommended. Contact your retailer for advice. If the probe is immersed to deeply, or not deeply enough, (or even not at all), your immersion detector will not work properly. Please make sure that the recommended immersion depth is respected. 7 3.4. Temporary installation For the installation tests, we recommend that at first, you do not cut the probe, but place the device higher (book, flat stone, brick, wooden board, …) to obtain an immersion depth of 15 (+/-3 cm). You must make sure that the device remains stable during the fall tests. 2 1 xx44 x1 x1 Place the wedge plug (provided with the fastening kit) at the end of the tube. Put the 4 pieces of stabilizing foam in place. 4 3 5 mm mini Position the device at the selected location. The rigid tube must be at least 5 mm away from the edge of the coping. 6 5 5 mm mini If your immersion depth is greater than 18 cm, use a booster (book, flat stone, brick, wooden board...), making sure it does not destabilize your central unit. Check the immersion depth. 7 8 15cm (±3cm) The immersion depth must be between 12 and 18 cm (ideally 15 cm). Carefully place a 2 to 3 kg weight on top of the device to hold it in place. 8 Warning: for the first 30 minutes after your device has been activated with the magnet for the first time, the siren sounds only for a short time, at a low volume. You are in TEST mode. For more information on this mode, refer to item 4.5. 3.5. Installation tests Make sure that the pool is still, and that your immersion detector is monitoring (indicator light off). If such is not the case, move the magnet over the swimmer symbol: If in spite of this, the indicator light does not go off, this means that the pool is not still enough. You must imperatively wait until your pool is still before carrying out the tests. Prepare a 6 kg weight by taping together the four 1.5 liter water bottles, as shown below: To make it easier for you to recover the 6 kg weight from the pool, we recommend that you tie a rope about 2 meters long around the neck of one of the 4 bottles. 2 1 10 mn Filtering working for 10 minutes, your immersion detector is monitoring (indicator light off) and must not go off. Your immersion detector is monitoring (indicator light off). 9 3 4 10 mn Filtering and robot cleaner working for 10 minutes, your immersion detector is monitoring (indicator light off) and must not go off. With the filtering system and robot cleaner working, drop the 6 kg weight from the point furthest away from your immersion detector. 5 The siren must sound within a maximum of 12 seconds after the fall. Stop the siren using the magnet. Wait for the automatic rearming (indicator light off). This may take about ten minutes. You must always perform additional fall tests at different locations in the pool (including steps) according to the procedure described above. After each fall, you must wait for the automatic reactivation of your immersion detector before performing another fall. Depending on wind and pool disturbance conditions, this reactivation may take about ten minutes. Warning: when your device switches out of TEST mode (specific tune), the siren of your immersion detector will sound at full volume. The TEST mode can be reactivated for another 30 minutes: to do this, please refer to item 4.5. If one of these tests fails: Look up item 5. I Contact your retailer for advice. I Check with the AstralPool After Sales Service at +34.93.713.63.44. I Send a letter to the AstralPool technical department, clearly describing your problem, and leaving your details at the following address: AstralPool SAU Avda Francesc Macia, 38 Planta 18 08208 Sabadell – Spain I 10 3.6. Final installation You have successfully completed all your installation tests. You can now carry out the final installation of your immersion detector. 1 1 Bring your immersion detector to “complete stop” mode (see item 4.6) so that it can be handled freely during its final installation. 3 2 Remove the weight from the cover. Unscrew the 4 screws. 4 5 Remove the cover. Remove the device and the booster from the coping. 6 7 Remove the 4 pieces of stabilizing foam. Reposition the device on the coping. 5 mm mini 9 8 Mark the water level on the tube of your device. Mark the 4 holes to be drilled. 11 10 Correct installation Remove the device. Make sure you handle your device carefully. 11 Recorded water level 15 cm (±3cm) Incorrect installation Using the measuring tape, measure the immersion depth from the water level. This must be between 12 cm and 18 cm (ideally 15cm). If the immersion depth is not right, mark out the recommended depth of 15 cm (+/- 3cm) using a pencil and measuring tape. Example: Immersion depth recorded = 25 cm. Recommended depth = 15 cm ± 3 cm. You must carefully cut your probe down to size by: 25 - 15 = 10 cm from the bottom of the tube. 12 13 Remove the wedge plug, and for ConfortTM, remove the pH probe from its housing, behind the rigid tube. Unscrew the 2 screws holding the rigid tube. 14 15 Firmly hold the rigid tube while cutting with the hacksaw. Carefully remove the rigid tube. DO NOT REMOVE THE BLACK TUBE. 12 16 17 Carefully replace the tube by pushing it in deep enough (about 3 cm): Align the 2 holes already drilled. Tighten the 2 screws holding the tube, and for ConfortTM, put the pH probe back in its housing behind the rigid tube. For ConfortTM, in order to adjust the length of the wires of the pH probe and temperature probe, proceed as follows: 18 19 Loosen the left-hand cable gland to release the temperature probe. Adjust the length of the wire so that the end of the probe is just above the rigid tube plug. Loosen the right-hand cable gland to release the pH probe. Adjust the length of the wire so that the end of the probe is immersed by 3 to 5 cm. The two cable glands must imperatively be properly retightened to ensure proper operation of the device. Perform these operations with care, without pulling too much on the wires. 20 21 Cut the black tube flush with the rigid tube, using shears or heavy-duty scissors. Replace the wedge plug. 13 22 23 Position and push in the 4 rawplugs. These must be flush with the coping. Drill the 4 holes with a Ø8mm bit. The installation of the foam pads, like the fastening (screws, washers, joints, etc.), must be done with care to ensure waterproofing and smooth functioning of your device. 24 25 Replace the 4 pieces of stabilizing foam. Reposition the device on the coping. 26 xx4 4 Tighten the 4 screws with their washers (provided with the fastening kit). Installing the washers guarantees that your device is waterproof. Joint properly compressed. Joint not compressed properly. 28 27 xx44 Always put the 4 small joints in place (provided with the fastening kit). Installing the joints guarantees that your device is waterproof. Check the immersion depth. 14 30 29 Tighten the 4 screws. Put the cover back on. When your device switches out of TEST mode (specific tune), the siren of your immersion detector will sound at full volume. The TEST mode can be reactivated for another 30 minutes: to do this, please refer to item 4.5. 3.7. Validation tests Make sure that the pool is still, and that your immersion detector is monitoring (indicator light off). If such is not the case, move the magnet over the swimmer symbol. If in spite of this, your immersion detector does not switch to monitoring mode, this means that the pool is not still enough. You must imperatively wait until your pool is still before carrying out the tests. 2 1 10 mn Filtering working for 10 minutes, your immersion detector is monitoring (indicator light off) and must not go off. Your immersion detector is monitoring (indicator light off). 3 4 10 mn Filtering and filtering robot working for 10 minutes, your immersion detector is monitoring (indicator light off) and must not go off. With the filtering system and robot cleaner working, drop the 6 kg weight from the point furthest away from your immersion detector. 15 5 The siren must sound within a maximum of 12 seconds after the fall. Stop the siren using the magnet. Wait for the automatic rearming (indicator light off). This may take about ten minutes. You must always perform additional fall tests at different locations in the pool (including steps) according to the procedure described above. After each fall, you must wait for the automatic reactivation of your immersion detector before performing another fall. Depending on wind and pool disturbance conditions, this reactivation may take about ten minutes. If one of these tests fails: I Look up item 5. I Contact your retailer for advice. I Check with the AstralPool After Sales Service at +34.93.713.63.44. I Send a letter to the AstralPool technical department, clearly describing your problem, and leaving your details at the following address: AstralPool SAU Avda Francesc Macia, 38 Planta 18 08208 Sabadell – Spain You have successfully completed all your validation tests. You can now carry out the last operations below: 7 8 x4 x4 Warning, it is essential that the 4 caps are put in place. Fill out the test validation sheet and send it to AstralPool. Regularly check the water level in your pool, especially when the weather is very hot, or rainy, or if it has been windy for several days. The immersion depth must imperatively be 15 centimeters plus or minus 3 centimeters. If the immersion depth is not respected your immersion detector will not work properly. 16 YOUR IMMERSION DETECTOR IS NOW ACTIVE, WITH THE INDICATOR LIGHT OFF. Make sure that you are no longer in TEST mode: the siren must be at full volume (100dB) You must always perform additional fall tests at different locations in the pool (including steps); the siren will go off loudly. If you do not stop it manually by moving the magnet over the swimmer symbol, the siren will sound for 1 minute and 30 seconds. Check that the alarm can be heard from the residence/living quarters. 4. Using Sun™/Confort™ The magnets must be kept out of the reach of children under five. PRECAUTIONS FOR USE • Certain rough weather conditions (strong winds, storms, etc.) and the use of certain powerful cleaning equipment can cause untimely alarm triggering. • Your alarm system will not operate if the water in the probe is frozen or the surface of the pool is frozen. It is hard to know when the water is frozen in the tube. If in doubt, check that your immersion detector is working properly. • When cleaning the outside of your device, (waterline, etc.), do not use any high-pressure cleaning apparatus, abrasive brush and/or other implements which might scratch or damage your immersion detector. • To ensure proper operation of your device, please keep the water pure and clean (in particular, to avoid algae formation inside the probe). • You are reminded that the French act No. 2003-9 dated 3 January 2003 on swimming pool safety requires that a device be installed permanently throughout the year. Your retailer or AstralPool, or MG International cannot be held liable in the event of drowning after the removal or complete stopping of your alarm system for whatever reason. • Should you restart your immersion detector after a long period, perform the tests described in item 3.7. In case of a problem, contact your retailer immediately. • The only authorized operation on the device once it is installed is changing the battery. • Regularly check that your fall detector is working properly by performing the monthly tests mentioned in this guide (see page 8), or have it checked by a professional. • Some cleaning robots like diving robot are incompatible with immersion detection systems. • The performance as defined in standard NF P90-307/A1 is not guaranteed beyond wind levels greater than those specified in this standard. 17 • Any user who shuts off the system must be aware that surveillance by a person must take over from the system. • Action must be taken when the siren is heard. • The greatest vigilance by the parent/responsible adult is necessary between the end of the swim and reactivation of the alarm system. • Do not activate the swim jet system after swimming, to allow the reactivation of the alarm system. 4.1. I want to have a swim While the immersion detector is monitoring (indicator light), move the magnet over the swimmer symbol in the activation area of your device: 1 The red indicator light of your immersion detector is flashing, you can have a swim without setting off the siren. After the swim or deactivation of the device, your immersion detector automatically resumes monitoring as soon as the pool is still again. The automatic restart can take place about 10 minutes after the end of the swim, depending on the disturbance in the pool and the wind conditions. 2 x10 DURING THIS TIME, YOUR POOL IS NOT PROTECTED. UTMOST VIGILANCE IS REQUIRED FROM THE PARENT/RESPONSIBLE ADULT. 3 Your immersion detector is no longer monitoring, the red indicator light is flashing. 18 4.2. Automatic restart Your immersion detector continuously checks the pool disturbance conditions. As soon as your pool becomes still again, after a swim or strong disturbance (strong wind, swim jet, etc.) your immersion detector resumes monitoring. Your pool is now protected. 4.3. Manual restart After your swim, you can ask your device to resume monitoring by moving the magnet over the swimmer symbol. You are then in one of the following situations: 1 Your immersion detector considers that your pool is still too disturbed. In this case, it cannot resume monitoring immediately, and indicates this by emitting a long beep, immediately followed by 10 high-pitched beeps, and the red indicator light keeps flashing. You can either wait for the automatic restart, or wait for the pool to be sufficiently still before trying manual restart again. DURING THIS TIME, YOUR POOL IS NOT PROTECTED. THE UTMOST VIGILANCE IS REQUIRED FROM THE PARENT/RESPONSIBLE ADULT. 2 Your immersion detector considers that it can resume monitoring. You will hear a long beep, and see the red indicator light go out. Your pool is now being monitored. 4.4. Too much wind In some cases, in the presence of rough weather conditions (strong wind, gusts of wind, etc.), your immersion detector is likely to stop monitoring function. Its red indicator light flashes. YOU MUST BE PARTICULARLY VIGILANT WHEN THE WEATHER IS ROUGH. Warning: The performance as defined in standard NF P90-307/A1 is not guaranteed beyond wind levels greater than those specified in this standard. 19 4.5. TEST mode In this mode, the siren sounds only for a short time, and at a low volume. This mode allows you to perform the installation and monthly tests without disturbing you or the neighborhood. The TEST mode lasts for 30 minutes. Exit from the TEST mode is indicated by a 5-second, low-volume specific tune. When all tests have been carried out successfully, you must wait for 30 minimum minutes without prompting the device to leave the test mode automatically. If the device leaves the test mode before completion of the tests, disconnect the battery and wait for a few minutes before reconnecting it to return to the test mode. 4.6. Off stop In complete stop mode, the indicator light of your immersion detector flashes once per minute. You are reminded that the French act No. 2003-9 dated 3 January 2003 on swimming pool safety requires that a device be installed permanently throughout the year. Your retailer or AstralPool, or MG International cannot be held liable in the event of drowning after the removal or complete stopping of your alarm system for whatever reason. When your immersion detector is in complete stop mode, vigilance by a person must imperatively take over, or another standard safety system must be installed as an alternative. Place and keep one of the magnets on the red stop sign until you obtain a continuous red light signal, then move the second magnet over the swimmer symbol. A series of high-pitched beeps (10 short beeps) and the indicator light flashing once a minute confirm that the device is in complete stop mode. To reactivate your immersion detector: I Move the magnet over the swimmer symbol; I You will hear 10 short, high-pitched beeps + flashing red indicator light; I Wait for the automatic restart (long beep - indicator light off) or restart manually (see item 4.3). Please make sure that your immersion detector is in monitoring mode before leaving your pool. If such is not the case, utmost vigilance is required from the parent/responsible adult. 20 4.7. Replacing the batteries Your immersion detector gives a low-battery alert by: I 1 short, low-pitched beep every minute, I 4 short, low-pitched beeps every time the magnet is moved over the swimmer symbol. In this case, the 7V lithium battery must imperatively be replaced as soon as possible with a new battery, available from your retailer. Once the battery has been replaced, put the cover back on, screw the 4 screws and replace the 4 plugs on the cover. You must imperatively perform the validation tests described in item 3.7. Be responsible, and take the old batteries back to your retailer instead of throwing them away. We advise you not to change the batteries at the start of the season. 4.8. I have a problem with my immersion detector Please contact by phone or mail the AstralPool After-Sales Service: I Tel: +34.93.713.63.44. I Address: AstralPool SAU Avda Francesc Macia, 38 Planta 18 08208 Sabadell – Spain Please provide a clear description of the problem encountered, so that your device can be processed quickly. Please also provide our technicians with your details and a sketch of your pool, including its dimensions (length, width, depth, recess if any) as well as the location of the return fittings, vacuum fittings, skimmer, and any other piece of equipment which might create disturbances, such as, for instance, a swim jet. Show the location of your immersion detector on the edge of your pool. This information will help our technicians to better understand the problem with your device, and to quickly find a solution. 5. Frequently asked questions During the installation QI1. During the test phase with filtering or filtering + robot cleaner, the siren goes off accidentally, or your immersion detector switches from monitoring mode to non-monitoring mode (red light flashing)? I RI1.1. Make sure that your immersion detector is not within one meter of the filtration system (return fittings, waste plug, skimmer, vacuum fittings, etc.) or waterfall or any other device that may disturb the pool at this place. I RI1.2. Check the immersion depth of your immersion detector. Rectify it if required. I RI1.3. Perform the installation and validation tests under favorable weather conditions. I RI1.4. Your immersion detector is not suited to your type of pool. Ask your retailer or the after-sales service for advice at +34.93.713.63.44. 21 I RI1.5. Your robot cleaner is not compatible with your immersion detector. It causes an event similar or identical to the fall of a child (standard NF P90-307/A1). Contact your retailer for advice. I RI1.6. If none of these conditions seems to you to be the cause of the malfunction, ask your retailer for advice or contact our technical support at +34.93.713.63.44. QI2. When the 6kg weight is dropped during the test phase, your immersion detector takes longer than 12 seconds to set off the siren, or does not set it off at all? I RI2.1. The dimensions of your pool are greater than 10 x 5m, or your pool is of a particular shape. A single immersion detector is not sufficient. Contact your retailer for advice. I RI2.2. Your immersion detector is not positioned at the recommended location. The fall occurs beyond its 7m detection range. Position it at the recommended location. See item 3.3. I RI2.3. If none of these conditions seems to you to be the cause of the malfunction, ask your retailer for advice or contact our technical support at +34.93.713.63.44. During use QU1. The siren goes off accidentally. I RU1.1. Check the immersion depth of your immersion detector. Rectify it if required. I RU1.2. The weather conditions are too unfavorable (strong wind, storm,…) and affect the operation of your device. I RU1.3. Your robot cleaner is not compatible with your immersion detector. It causes an event similar or identical to the fall of a child (standard NF P90-307/A1). Contact your retailer for advice. I RU1.4. If none of these conditions seems to you to be the cause of the malfunction, ask your retailer for advice or contact our technical support at +34.93.713.63.44. QU2. Your immersion detector does not go off during the monthly tests. I RU2.1. Check the condition of your batteries. Please refer to item 4.7. I RU2.2. Check the immersion depth of your immersion detector. Rectify it if required. I RU2.3. The weather conditions are too unfavorable (strong wind, storm,…) and affect the operation of your device. I RU2.4. If none of these conditions seems to you to be the cause of the malfunction, ask your retailer for advice or contact our technical support at +34.93.713.63.44. For any other malfunction, ask your retailer for advice or contact our technical support at +34.93.713.63.44. 6. Further information LEGAL INFORMATION The French Act No. 2003-9 and its implementing order No. 2003-1389 were passed in order to fight against the growing number of accidents and drownings in privately-owned swimming pools for individual or collective use. These laws set the following provisions: Starting from January 1, 2004, any new, non-enclosed, in-ground private swimming pool for individual or collective use must be fitted with a standardized safety system. As of this date, the builder or installer of such a swimming pool must provide the owner with a technical sheet indicating the system chosen. Owners of non-enclosed in-ground private swimming pools for individual or collective use, installed before January 1, 2004, must have equipped their swimming pool with a standardized safety system by January 1, 2006. 22 If the dwelling is rented seasonally, a standardized safety system must be installed before May 1, 2004. The importance of active monitoring by parents must be underlined. SAFETY ADVICE RELATED TO THE ALARM This alarm system is not a replacement for common sense or individual responsibility. Its purpose is not to be a replacement for vigilance by a parent or responsible adult, which remains the vital factor in protecting children under the age of 5. This alarm is a protective device which signals a danger (or danger risk). A responsible adult must take quick action within 3 minutes of the sounding of the alarm signal. Any user who shuts off the system must be aware that surveillance by a person must take over from the system. You must take action when the failure signal sounds are heard. The greatest vigilance by the parent/responsible adult is necessary between the end of the swim and reactivation of the alarm system. Switch of the swim jet at the end of the swim, to allow the reactivation of the alarm system. The performance as defined in standard NF P90-307/A1 is not guaranteed beyond wind levels greater than those specified in this standard. In no event must the installation of the alarm system reduce your vigilance or replace active monitoring of the swimming pool and the area around it. This alarm system, like any other safety device or equipment, is an additional tool which is useful in the event of a momentary lack of surveillance. GENERAL SAFETY ADVICE You alone are responsible for your children's safety! The risk is greatest when children are less than five years old. Accidents don't just happen to other people! Be prepared, and tackle it! Monitor and act! I Children must be constantly supervised from nearby. I Nominate one adult as responsible for safety. I Increase monitoring when there are many people using the pool. I Teach your children to swim as early as possible. I Wet back of neck, arms and legs before entering the water. I Learn the steps that save lives, especially those for children. I Prohibit diving and jumping in the presence of small children. I Prohibit running and playing around the pool. I Do not allow a child who does not swim well to enter the pool without a life jacket or vest, or unaccompanied. I Do not leave toys near or in an unattended pool. I Constantly maintain clear and pure water. I Store water treatment products out of reach of children. I Some swim jet systems do not allow the immersion detection system to be reactivated automatically. I Some robot cleaners like diving robot are incompatible with immersion detection systems. I In order to prevent access to the pool by children under five when the failure signal has triggered, take all the required measures until the device is repaired. I The only authorized operation is to change the batteries at the beginning of the season. Be prepared! I Telephone accessible near the pool to not leave your children unattended while you phone. I Life-buoy and pole near the pool. 23 In the event of accident I Remove the child from the water as quickly as possible. I Immediately call the emergency services and follow the instructions they give you. I Replace wet clothes with warm blankets. Emergency phone numbers (to be learnt by heart and displayed near the pool) Fire brigade: 18 I Emergency medical service: 15 I European emergency number: 112 (from all phones) I Immersion time and survival rate Immersion time Survival rate 1 minute 95 % 2 minutes 80 % 3 minutes 65 % 4 minutes 25 % 5 minutes 1% Figures provided by the French Department of Civil Protection and used as reference in standards and official laws. There is no zero risk. Only active monitoring by you, combined with passive monitoring by your immersion detector can give a high level of safety. In no event must the installation of this alarm system reduce your vigilance or replace active monitoring of the swimming pool and the area around it. Speed of intervention after the alarm is triggered is decisive. Never go too far if your child is playing near the pool. Guidelines on resuscitations and first aid procedures are available in many emergency centers or associations. You can also contact your state health insurance office to attend first aid courses. 24 7. Warranty and After-Sales Service Your immersion detector is guaranteed for 2 years (detection unit and optional remote wireless siren). Ensure that children or animals are not present during installation of your device. WARRANTY COVER AstralPool or its retailers shall provide the purchaser of this product (Sun™/Confort™) with the services presented below. AstralPool, distributor of Sun™/Confort™ warrants Sun™/Confort™ against any defects in materials and workmanship during the period stipulated below, beginning from the date of first purchase: I Sun™/Confort™ central units 2 years parts and labor I Remote wireless siren: 2 years parts and labor Any of the consumables (e.g. batteries, dehydrating sachets, magnets, etc.) included in the original Sun™/Confort™packaging that prove defective due to a defect in materials or workmanship shall be replaced free of charge during a period of 90 days, starting from the date of purchase. If the user customer sells or transfers ownership or use of Sun™/Confort™ in any manner whatsoever during the warranty period, the warranty shall be considered void, since no warranty of correct installation or transport can be given by the final user, particularly as regards the full respect of the validation sheets. It is expressly indicated that this clause is opposable to the new owner. For the contractual parts and labor warranty to be applied, all the following conditions must be met: Installation in compliance with the applicable product documentation or carried out by a professional installer I Installation tests performed and test validation sheet completed, signed and sent back to AstralPool by mail, within 7 days after purchase (postmark taken as proof). I Ownership of a copy of the purchase invoice. I Non deterioration of the components of your alarm system through misuse, breakage, and more generally, through the fault of the user. I Regular maintenance of the siren and the unit (check of operating status of unit by regular tests and monthly update of service manual). I Immersion tests performed regularly (once per month). Do not hesitate to inform your retailer in the event of failures. I Compliance with installation instructions I Should a repair be necessary In case of failure by Sun™/Confort™ the customer must make sure that the problem encountered is not due to a faulty installation, non-compliance with the installation and operation guide, or to maintenance. If, after return to After-Sales Service, no defect in materials or workmanship is established by the technicians, AstralPool reserves the right to invoice the After-Sales Service's costs. If Sun™/Confort™ proves to malfunction due to a defect in materials or workmanship during the warranty period, AstralPool shall either replace or repair the device, ONLY ON CONDITION THAT the customer produces a copy of original purchase. If this proof of purchase is not produced, AstralPool reserves the right to refuse to carry out a service, or to invoice the costs of maintenance for all work carried out. In the event of technical difficulties with Sun™/Confort™the customer must immediately contact the retailer as a priority, or, if this is unsuccessful, AstralPool. 25 For any call, the customer must be able to describe the problem in detail so that the retailer or an after-sales service representative can determine whether a repair is required. The customer must provide the serial number, the date and precise place of purchase (town, name and address of retailer). In any correspondence the customer must clearly describe the problem and provide the serial number, the date and precise place of purchase, and clearly write his contact details. AstralPool reserves the right to replace the repairable parts with new or refurbished parts. In the event of the equipment or parts being immobilized for more than 7 days in the workshop or at home, the warranty shall be extended by the amount of time it is immobilized. This time limit shall start from the day either of acceptance by the AstralPool approved repairer or of the request for intervention. During the immobilization period, it shall be left to the discretion of the retailer to offer a temporary replacement device. Neither the retailer nor AstralPool are obliged to provide a replacement on a systematic basis for the device in the event of immobilization. Be sure to increase active personal monitoring of your pool during this period. WARRANTY EXCLUSIONS The warranty does not apply to products on which the original identification marks have been removed or modified and does not apply to defects or failures resulting from an accident, negligence or misuse; non compliance with the user’s manual, a failure or defect in the electrical supply; in an external electrical circuit; lightning; the use of parts not supplied by AstralPool; prolonged immersion having degraded components; an unusual physical or electrical constraint; modification, adjustment, repair, maintenance or installation of a part by any other party than AstralPool or its approved subcontractors and retailers or due to any other cause which, at AstralPool’s discretion, does not result from a defect in materials and workmanship . This warranty is given in lieu of all other expressed or implied warranty, and the liability of AstralPool hereby shall be only limited to the repair of Sun™/Confort™ or to the replacement of the aforementioned product. AstralPool shall, in particular, not be required to replace or repair Sun™/Confort™ if they are defective for the reasons given in this section. IN NO EVENT OR CIRCUMSTANCES shall AstralPool be held responsible for any other costs, charges, expenses, losses or damages (indirect or otherwise), of any kind whatsoever. In addition, in the event that the device be returned or sent to AstralPool with modifications, damage of any kind or removal of components, AstralPool shall be permitted to refuse to warrant the device, and shall in no event be required to repair or replace it. In no event may your retailer, the distributor or the manufacturer of this alarm system be held responsible for any child, dependant person, adult or animal falling or drowning. In no event must the installation of the alarm system reduce your vigilance or replace active personal monitoring of the swimming pool and the pool area. This warranty constitutes AstralPool’s sole responsibility with regard to the products and services supplied pursuant to this warranty. AstralPool shall carry out no other obligation, duty or responsibility, whether contractual, extracontractual (including responsibility for negligence) or other towards the customer. It should be noted that certain rough weather conditions may destabilize your Sun™/Confort™ (false alarms). In these conditions check that your child does not go near the pool. Avoid turning your immersion detector off for a long period of time. AstralPool has only an obligation of means (to supply to the customer a device in working order, with no defects in materials and workmanship). AstralPool cannot be held responsible for any child, adult or animal whatsoever falling or drowning. Monitoring by parents remains the best safety solution for children. 26 SUN™/CONFORT™ IS NOT A REPLACEMENT FOR COMMON SENSE OR INDIVIDUAL RESPONSIBILITY. ITS PURPOSE IS NOT TO BE A REPLACEMENT FOR RESPONSIBILITY AND VIGILANCE BY A PARENT AND/OR RESPONSIBLE PERSON, WHICH REMAIN THE ESSENTIAL FACTOR IN PROTECTING CHILDREN AND DEPENDANT PERSONS. No clause in this warranty affects the user's statutory rights. Product reference: SunTM : (SOL007-A) ConfortTM : (ELI007-A) Distributor: AstralPool SAU – Avda Francesc Macia, 38 Planta 18 – 08208 Sabadell - ESPAGNE Tél. +34.93.713.63.44 Manufacturer: MG International SA – ZI Athélia II – 220, Impasse du Serpolet – 13600 La Ciotat – France 27 8. Monthly tests In order to check the proper operation of your Sun™/Confort™, it is essential that verification tests be carried out on a monthly basis (look up item 3.7) and that the results be recorded in the form below. In the event of malfunction, inform your retailer immediately and take the necessary measures to prevent access to your pool, and monitor it. Retailer contact details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Serial number of device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Date of purchase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.tests performed on ............................... 13.tests performed on ............................. successful Ì - not successful Ì successful Ì - not successful Ì 2.tests performed on ............................... 14.tests performed on ............................. successful Ì - not successful Ì successful Ì - not successful Ì 3.tests performed on ............................... 15.tests performed on ............................. successful Ì - not successful Ì successful Ì - not successful Ì 4.tests performed on ............................... 16.tests performed on ............................. successful Ì - not successful Ì successful Ì - not successful Ì 5.tests performed on ............................... 17.tests performed on ............................. successful Ì - not successful Ì successful Ì - not successful Ì 6.tests performed on ............................... 18.tests performed on ............................. successful Ì - not successful Ì successful Ì - not successful Ì 7.tests performed on ............................... 19.tests performed on ............................. successful Ì - not successful Ì successful Ì - not successful Ì 8.tests performed on ............................... 20.tests performed on ............................. successful Ì - not successful Ì successful Ì - not successful Ì 9.tests performed on ............................... 21.tests performed on ............................. successful Ì - not successful Ì successful Ì - not successful Ì 10.tests performed on ............................. 22.tests performed on ............................. successful Ì - not successful Ì successful Ì - not successful Ì 11.tests performed on ............................. 23.tests performed on ............................. successful Ì - not successful Ì successful Ì - not successful Ì 12.tests performed on ............................. 24.tests performed on ............................. successful Ì - not successful Ì successful Ì - not successful Ì 28 TST0507-A TEST VALIDATION SHEET To be filled out in block letters and imperatively sent back by mail SunTM : 37059/SOL007-A - ConfortTM : 37060/ELI007-A serial number: FILL OUT and SEND this test validation sheet by mail to ASTRAPOOL within 7 DAYS AFTER THE PURCHASE of your immersion detector. This sheet must be initialed on both sides, and bear the handwritten statement “tests successful, performed as per recommendations” followed by your signature (see overleaf). The 2-year contractual guarantee is conditioned by the dispatch of the test validation sheet. In case of negligence or non receipt of the test validation sheet, AstraPool will accept no responsibility for proper operation. The purpose of these tests is to validate the proper operation of your device, and to ensure optimal fall detection according to the pool configuration. Owner Mr. Mrs. Miss First name: Surname: Address: Postcode: Town: Country: E-mail : Tel. : Date of purchase: Tests performed on: Retailer Retailer name: Address: Postcode: Town: Country: E-mail : Remarks: Your immersion detector has been designed and configured to detect a child (minimum weight 6 kg) falling into a swimming pool with maximum dimensions of 10 m x 5 m. You must imperatively perform these validation tests after final setting up of your immersion detector, by scrupulously following the recommendations given in the installation and operation guide. In case of malfunction, please refer to the recommendations written on the packaging, or contact your retailer. Make sure that the pool is still, that there is no wind, and that your immersion detector is monitoring (indicator light off). If such is not the case, move the magnet over the swimmer symbol. If in spite of this, the indicator light does not go off, the pool is not still enough. You must imperatively wait until your pool is still before carrying out the tests. Test 1 - Filtering if OK Test 1 validated by the owner*: Test 1 validated by the installer*: Yes Yes No No Signature of present owner: Filtering system running for 10 minutes, your immersion detector is monitoring (indicator light off), and must not either stop (red indicator light flashing) or go off. *cross out inappropriate statement (presence of installation engineer is not obligatory but is recommended) Test 2 - Robot + Filtering Only perform this test if you have a cleaning robot, otherwise move directly on to test 3. if OK Test 2 validated by the owner*: Test 2 validated by the installer*: Yes Yes No No Signature of present owner: Filtering system and robot running for 10 minutes, your immersion detector is monitoring (indicator light off), and must not either stop (red indicator light flashing) or go off. *cross out inappropriate statement (presence of installation engineer is not obligatory but is recommended) Test 3 - Fall if OK Test 3 validated by the owner*: Test 3 validated by the installer*: Yes Yes No No Signature of present owner: With the filtering system and robot cleaner working, drop the 6 kg weight from the top of the coping. The siren must sound a maximum of 12 seconds after the fall. *cross out inappropriate statement (presence of installation engineer is not obligatory but is recommended) If all tests are successful, sign at the bottom of the page, add your initials and send this document back to ASTRAPOOL. If one of these test fails, contact your retailer for advice or check with the ASTRALPOOL SAU After-Sales Service at +34 93 713 63 44. I certify that these tests have been performed in their entirety and that the device which was sold and delivered to me is in compliance and in working order. I confirm that I received the complete product (packaging, central unit with flexible tube, rigid tube, remote siren – optional - batteries, fastening kit with contact magnets, installation and operation guide with guarantee and monthly maintenance sheets). Swimming pool immersion detectors are not a replacement for common sense or individual responsibility. Their purpose is not to be a replacement for responsibility and vigilance by a parent and/or responsible person, which remain the vital factor in protecting children and dependant persons. In no event may your retailer or the manufacturer of your swimming immersion system by held responsible for any child, dependant person, adult or animal falling or drowning. In no event must the installation of the immersion system reduce your vigilance or replace active monitoring of the swimming pool and the area around it. Follow the safety advice shown on the packaging of your immersion detection system and in its installation and operation guide. Date and signature with handwritten statement “tests successful, performed as per recommendations” The owner The installer 1 2 SUN™ CONFORT™ • • • • • • • • - • • • • • • • • • 3 ... ... _ _ DURANT L’INSTALLATION DE VOTRE DÉTECTEUR D’IMMERSION, LA PLUS GRANDE VIGILANCE DU PARENT/ADULTE RESPONSABLE EST IMPÉRATIVE. 4 tube rigide 2 3 4 5 1 5 3 4 LITHIUM BATTERY ON OFF 6 7m maximum 15cm (±3cm) 7 1 xx44 x1 x1 4 3 5 mm mini 6 5 5 mm mini 7 8 15cm (±3cm) 8 2 1 10 mn 9 3 4 10 mn 5 10 2 4 5 6 7 5 mm mini 9 8 11 10 15 cm (±3cm) Mal posé 12 13 14 15 12 16 17 18 19 20 21 13 22 23 25 26 28 27 14 30 29 1 10 mn 3 4 10 mn 15 5 8 16 17 1 2 x10 3 DURANT CETTE PÉRIODE, VOTRE BASSIN N’EST PAS PROTÉGÉ. LA PLUS GRANDE VIGILANCE DU PARENT/ADULTE RESPONSABLE EST IMPÉRATIVE. 18 19 20 21 22 23 1 minute 95 % 2 minutes 80 % 3 minutes 65 % 4 minutes 25 % 5 minutes 1% 24 25 26 27 28 TST0507-A numéro de série : Nom : Adresse : Code postal : Ville : Pays : E-mail : Tel. : Date d’achat : Ville : Pays : E-mail : : Test 1 - Filtration si OK Oui Oui Non Non si OK Oui Oui Non Non Oui Oui Non Non L’installateur 1 SUN™ CONFORT™ • • • • • • • • - • • • • • • • • • 2 indicador apagado Baterías débiles 3 ... ... parpadeo cada dos segundos ............... parpadeo una vez cada minuto _ _ DURANTE LA INSTALACIÓN DE SU DETECTOR DE CAÍDA, EL PADRE/ADULTO RESPONSABLE DEBERÁ PRESTAR LA MÁXIMA ATENCIÓN. 4 2 sonda de pH 3 4 5 1 5 3 4 LITHIUM BATTERY 1 en ON 2 en OFF 3 en ON 4 en ON 5 en ON ON OFF 6 7 m máximo 15cm (±3cm) 7 1 xx44 x1 x1 4 3 5 mm mini 6 5 5 mm mini 7 8 15cm (±3cm) 8 2 1 10 mn 9 3 4 10 mn 5 10 2 Afloje los 4 tornillos. 4 5 6 7 9 8 11 10 15 cm (±3cm) 12 13 14 15 12 16 17 18 19 20 21 13 22 23 25 26 Junta mal apretada. 28 27 14 30 29 1 10 mn 3 4 10 mn 15 5 8 16 17 1 2 x10 DURANTE ESTE PERÍODO DE TIEMPO, LA PISCINA NO ESTARÁ PROTEGIDA. EL PADRE/ADULTO RESPONSABLE DEBERÁ PRESTAR LA MÁXIMA ATENCIÓN. 3 18 19 20 21 I 22 23 1 minuto 95 % 2 minutos 80 % 3 minutos 65 % 4 minutos 25 % 5 minutos 1% 24 25 26 SUN™/CONFORT™ NO SUSTITUYE EN MODO ALGUNO AL SENTIDO COMÚN NI A LA RESPONSABILIDAD INDIVIDUAL TAMPOCO REEMPLAZA LA VIGILANCIA Y LA RESPONSABILIDAD DE LOS PADRES Y DE LOS ADULTOS RESPONSABLES, FACTOR ESENCIAL PARA LA PROTECCIÓN DE LOS NIÑOS Y DE LAS PERSONAS DEPENDIENTES. Ninguna cláusula de esta garantía afecta a los derechos estatutarios del usuario. 27 - con éxito Ì - - - - sin éxito Ì - - - - sin éxito Ì - - sin éxito Ì - sin éxito Ì - - sin éxito Ì - sin éxito Ì - sin éxito Ì - sin éxito Ì - sin éxito Ì - sin éxito Ì - sin éxito Ì - sin éxito Ì - sin éxito Ì - 28 - TST0507-A TM Propietario Sr. Sra. Srta. País: E-mail : Tel. : Fecha de compra: Provincia: País: Si Si No No Firma del propietario presente: si OK Si Si No No Firma del propietario presente: Prueba 3 - Caída si OK Si Si No No Firma del propietario presente:
advertisement
Related manuals
advertisement