11 Maintenance of the installation

Ensure that the general electrical power supply has been cut off before starting any repair work.

11 .1 Hydraulic checks

"

Warning : If frequent refills are required it is essential that you look for any leaks .

If filling and re-pressurization are required, check what type of fluid has been used initially.

Recommended filling pressure: 1 to 2 bar

(Precise filling pressure is determined by the manometric height of the installation).

Each year,

- Check the expansion vessel pressure (precharge 1 bar) and the correct functioning of the safety valve.

- Verify the safety unit on the cold water supply inlet.

Make it work as prescribed by the manufacturer.

- Check the shut-off.

- Verify the correct functioning of the distribution valve.

11 .2 Maintenance of the DHW tank

Maintenance of the tank must be undertaken once a year

(The frequency may vary according to water hardness).

11 .2 .1 Emptying the hot water tank

- Remove the facade from the hydraulic unit.

- Close the cold water entry into the tank.

- Open a hot water tap and open the water tank emptying valve (ref.

1

).

11 .2 .2 Descaling

- Empty the water tank.

- Remove the hood of the electrical back-up (ref.

2

).

- Disconnect the electrical back-up.

- Unplug the ACI.

- Remove the electrical back-up (ref.

3

).

- Remove any limescale deposits that have built up inside the tank. It is best to let the scale stuck to the walls of the tank: it forms a protective layer.

- Gently remove any limescale deposit on the glove finger. Do not use any metal objects or chemical or abrasive products.

- Replace the joint of the electrical back-up (ref. each time it is dismantled.

4

)

- Replace the electrical back-up and carry out ‘crossed’ locking of the nuts.

- Reconnect the electrical back-up.

- Plug in the ACI.

- Replace the hood of the electrical back-up.

5

1

Close

Open

4

6

3

2

figure 58 - Emptying the hydraulic unit and/or Domestic hot water tank

11 .3 Checking the outdoor unit

- Dust off the heat exchanger if necessary, being careful not to damage the fins.

- Straighten the vanes using a comb.

- Check that there is nothing obstructing the passage of air.

- Check the fan.

- Verify that condensate drain is not obstructed.

• Checking the refrigerant circuit :

- When the refrigerant charge is in excess of 2kg

(>10kW models), it is compulsory to have an approved after sales service check the refrigerant circuit every year (with a certificate of capacity for the handling of

refrigerants) (see para. 10.2, page 70)

- Check the lack of leak (connections, valves…).

11 .4 Electrical checks

- Check connections and possible tightening.

- Check the cables condition and electronic boards.

- ACI light: In normal operation, the light flashes.

- 74 -

Installation and operating manual "1768 - EN"

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Key Features

  • Efficient and reliable heating and cooling
  • Split integrated DHW type
  • Heating only application (No cooling function)
  • Cascade connection possible
  • Low noise operation (Sound pressure level of only 61 dB)
  • Compact and lightweight design

Related manuals

Frequently Answers and Questions

What is the maximum heating capacity of the Fujitsu WGYK160DG9/WOYK160LCTA?
The maximum heating capacity is 16 kW
What is the maximum cooling capacity of the Fujitsu WGYK160DG9/WOYK160LCTA?
This model does not have cooling function
What is the minimum operating temperature of the Fujitsu WGYK160DG9/WOYK160LCTA?
The minimum operating temperature is -25°C
What is the maximum operating temperature of the Fujitsu WGYK160DG9/WOYK160LCTA?
The maximum operating temperature is 46°C
What is the maximum flow rate of the Fujitsu WGYK160DG9/WOYK160LCTA?
The maximum flow rate is 1.4 m³/h
What is the maximum pressure of the Fujitsu WGYK160DG9/WOYK160LCTA?
The maximum pressure is 3 bar