HIGH PRESSURE GAS
CYLINDERS
OCX 8800
GENERAL PRECAUTIONS FOR HANDLING AND STORING
HIGH PRESSURE GAS CYLINDERS
Edited from selected paragraphs of the
Compressed Gas Association's
"Handbook of Compressed Gases" published in 1981
Compressed Gas Association
1235 Jefferson Davis Highway
Arlington, Virginia 22202
Used by Permission
1. Never drop cylinders or permit them to strike each other violently.
2. Cylinders may be stored in the open, but in such cases, should be protected against extremes of weather and, to prevent rusting, from the dampness of the ground. Cylinders should be stored in the shade when located in areas where extreme temperatures are prevalent.
3. The valve protection cap should be left on each cylinder until it has been secured against a wall or bench, or placed in a cylinder stand, and is ready to be used.
4. Avoid dragging, rolling, or sliding cylinders, even for short distance; they should be moved by using a suitable hand-truck.
5. Never tamper with safety devices in valves or cylinders.
6. Do not store full and empty cylinders together. Serious suckback can occur when an empty cylinder is attached to a pressurized system.
7. No part of cylinder should be subjected to a temperature higher than
52°C (125°F). A flame should never be permitted to come in contact with any part of a compressed gas cylinder.
8. Do not place cylinders where they may become part of an electric circuit. When electric arc welding, precautions must be taken to prevent striking an arc against the cylinder.
A-21
OCX 8800
Instruction Manual
IM-106-880 Original Issue
February 2005
A-22
advertisement
Related manuals
advertisement
Table of contents
- 7 Component Checklist
- 7 System Overview
- 15 Specifications
- 20 Mechanical Installation
- 26 Electrical Installation
- 32 Pneumatic Installation
- 38 Initial Startup
- 39 Verify Installation
- 41 Initial Power Up
- 42 Set Test Gas Values
- 42 OCX 8800 Reset Procedure
- 43 Overview
- 43 Display Orientation
- 44 LOI Controls
- 44 Overview
- 44 LOI Key Functions
- 45 LOI Status Codes
- 46 LOI Menu Tree
- 50 D/A Trim Procedures
- 53 Overview
- 53 HART Communicator Signal Connections
- 56 HART Communicator PC Connections
- 57 HART Menu Tree
- 61 D/A Trim Procedures
- 63 Overview
- 63 Fully Automatic Calibration
- 66 Operator - Initiated Autocalibration
- 66 Manual Calibration
- 73 Overview
- 73 OCX 8800 Removal and Installation
- 74 OCX with Remote Electronics
- 80 Repair Sensor Housing
- 80 Sensor Housing Disassembly
- 90 Sensor Housing Assembly
- 100 Repair Electronics Housing
- 100 Electronics Housing Disassembly
- 103 Electronics Housing Assembly
- 106 Replace Tube Fittings
- 106 Remove Tube Fittings
- 107 Install Tube Fittings
- 109 Overview
- 109 Grounding
- 109 Electrical Noise
- 109 Electrostatic Discharge
- 110 Total Power Loss
- 110 Diagnostic Alarms
- 111 Fault Isolation
- 119 Alarm Relay Events
- 122 Sensor Housing
- 126 Electronics Housing
- 129 O2 Cell and Heater Strut Assembly
- 132 Safety Instructions
- 145 Ceramic Fiber Products Material Safety Data Sheet
- 151 High Pressure Gas Cylinders
- 153 Overview
- 153 Description
- 154 Installation
- 154 Setup
- 159 Returning Material