NOTES FOR SAFE OPERATION. YASKAWA V7 Drive, VS-606V7 Series
विज्ञापन
विज्ञापन
NOTES FOR SAFE OPERATION
Read this instruction manual thoroughly before installation, operation, maintenance or inspection of the VS-606V7. In this manual, NOTES FOR SAFE OPERATION are classified as “WARNING” or “CAUTION”.
WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury to personnel.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to personnel and damage to equipment. It may also be used to alert against unsafe practices.
In either case, follow these important notes.
NOTE
These are steps to be taken to ensure proper operation.
3
4
Warnings for UL/cUL M
a
rking
• Do not connect or disconnect wiring, or perform signal checks while the power supply is turned ON.
• The Inverter internal capacitor is still charged even after the power supply is turned
OFF. To prevent electric shock, disconnect all power before servicing the Inverter.
Then, wait at least one minute after the power supply is disconnected and all indicators are OFF.
• Do not perform a withstand voltage test on any part of the Inverter. This electronic equipment uses semiconductors and is vulnerable to high voltage.
• Do not remove the Digital Operator or the blank cover unless the power supply is turned OFF. Never touch the printed control board (PCB) while the power supply is turned ON.
• The Inverter is not suitable for use on a circuit capable of delivering more than
18,000 RMS symmetrical amperes, 250volts maximum (200V class units) or
18,000 RMS symmetrical amperes, 480volts maximum (400V class units).
CAUTION
(Ref. page)
Low voltage wires shall be wired with Class I Wiring.
. . . . . . . . . . . . . . . 22
RECEIVING
CAUTION
(Ref. page)
• Do not install or operate any inverter which is damaged or has missing parts.
Failure to observe this caution may result in personal injury or equipment damage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14-16
MOUNTING
CAUTION
(Ref. page)
• Lift the cabinet by the cooling fin. When moving the unit, never lift by the plastic case or the terminal covers.
Otherwise, the main unit may be dropped causing damage to the unit. . . . . . . 18
• Mount the inverter on nonflammable material (i.e., metal).
Failure to observe this caution can result in a fire. . . . . . . . . . . . . . . . . . . . . . . 18
• When mounting units in an enclosure, install a fan or other cooling device (open chassis to keep the intake air temperature below 122
°
F (50
°
C).
Overheating may cause a fire or damage to the unit. . . . . . . . . . . . . . . . . . . . . 19
• The VS mini generates heat. For effective cooling, mount it vertically.
Refer to the figure in “Mounting Dimensions” on page 18.
5
6
WIRING
WARNING
(Ref. page)
• Start wiring only after verifying that the power supply is turned OFF.
Failure to observe this warning can result in electric shock or fire. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
• Wiring should be performed only by qualified personnel.
Failure to observe this warning can result in electric shock or fire. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
• When wiring the emergency stop circuit, check the wiring thoroughly before operation.
Failure to observe this warning can result in personal injury. . . . . . . . . . . . . . 22
WARNING
(Ref. page)
• Make sure to ground the ground terminal according to the local grounding code.
Failure to observe this warning can result in electric shock or fire. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
• For 400V class, to conform to CE requirements, make certain to ground the supply neutral.
Failure to observe this warning can result in electric shock or fire. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
CAUTION
(Ref. page)
• Verify that the inverter rated voltage coincides with the
AC power supply voltage.
Failure to observe this caution can result in personal injury or fire.
• Do not perform a withstand voltage test of the inverter
It may cause semi-conductor elements to be damaged.
• To connect a braking resistor, braking resistor unit or braking unit, follow the procedures described in this manual.
Improper connection may cause a fire.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
• Make sure to tighten terminal screws of the main circuit and the control circuit.
Failure to observe this caution can result in a malfunction, damage or a fire. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
• Never connect the AC main circuit power supply to output terminals U, V and W.
The inverter will be damaged and void the warranty. . . . . . . . . . . . . . . . . . . . 22
• Do not connect or disconnect wires or connectors while power is applied to the circuit.
Failure to observe this caution can result in personal injury.
• Do not change signals during operation
The machine or the inverter may be damaged.
7
8
OPERATION
WARNING
(Ref. page)
• Only turn ON the input power supply after replacing the digital operator/blank cover (optional).
Do not remove the digital operator or the covers while current is flowing.
Failure to observe this warning can result in electric shock.
• Never operate the digital operator or dip switches when your hand is wet.
Failure to observe this warning can result in electric shock.
• Never touch the terminals while current is flowing, even during inverter stopping.
Failure to observe this warning can result in electric shock.
• When the fault retry function is selected, stand clear of the inverter or the load, since it may restart suddenly after being stopped.
(Construct machine system, so as to assure safety for personnel, even if the inverter should restart.) Failure to observe this warning can result in personal injury. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
• When continuous operation after power recovery is selected, stand clear of the inverter or the load, since it may restart suddenly after being stopped.
(Construct machine system, so as to assure safety for personnel, even if the inverter should restart.) Failure to observe this warning can result in personal injury. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
• Since the digital operator stop button can be disabled by a function setting, install a separate emergency stop switch.
Failure to observe this warning can result in personal injury.
• If an alarm is reset with the operation signal ON, the inverter restarts automatically. Only reset the alarm after verifying that the operation signal is OFF.
Failure to observe this warning can result in personal injury. . . . . . . . . . . . . . 27
OPERATION (Cont.)
CAUTION
(Ref. page)
• Never touch the heatsink or braking resistor, the temperature is very high.
Failure to observe this caution can result in harmful burns to the body.
• Since it is easy to change operation speed from low to high speed, verify the safe working range of the motor and machine before operation.
Failure to observe this caution can result in personal injury and machine damage.
• Install a holding brake separately if necessary.
Failure to observe this caution can result in personal injury.
• Do not change signals during operation.
The machine or the inverter may be damaged.
• All the parameters of the inverter have been preset at the factory. Do not change the settings unnecessarily.
The inverter may be damaged. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
MAINTENANCE AND INSPECTION
WARNING
(Ref. page)
• Never touch high-voltage terminals in the inverter.
Failure to observe this warning can result in an electrical shock. . . . . . . . . . 127
• Disconnect all power before performing maintenance or inspection. Then wait at least one minute after the power supply is disconnected and all LEDs and CHARGE LED are extinguished.
The capacitors are still charged and can be dangerous. . . . . . . . . . . . . . . . . . 127
9
WARNING
(Ref. page)
• Do not perform withstand voltage test on any part of the VS-606V7.
This electronic equipment uses semiconductors and is vulnerable to high voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
• Only authorized personnel should be permitted to perform maintenance, inspections or parts replacement.
[Remove all metal objects (watches, bracelets, etc.) before operation.]
(Use tools which are insulated against electrical shock.)
Failure to observe this warning can result in an electrical shock. . . . . . . . . . 127
CAUTION
(Ref. page)
• The control PC board employs CMOS ICs.
Do not touch the CMOS elements.
They are easily damaged by static electricity.
• Do not connect or disconnect wires, digital operator, connectors, or cooling fan while power is applied to the circuit.
Failure to observe this caution can result in personal injury. . . . . . . . . . . . . . 127
Others
WARNING
• Never modify the product.
Failure to observe this warning can result in an electrical shock or personal injury and will void the warranty.
(Ref. page)
10
WARNING DISPLAY
A warning label is displayed on the front cover of the inverter, as shown below. Follow these instructions when handling the inverter.
11
CONTENTS
NOTES FOR SAFE OPERATION . . . . . . . . . . . . . . . . . . . . 3
1. RECEIVING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
• Checking the Name Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2. IDENTIFYING THE PARTS . . . . . . . . . . . . . . . . . . . . . . 16
3. MOUNTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
• Choosing a Location to Mount the Inverter . . . . . . . . . . . . . . 18
• Mounting Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
• Mounting/Removing Components . . . . . . . . . . . . . . . . . . . . . 20
4. WIRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
• Wiring Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
• Wire and Terminal Screw Sizes . . . . . . . . . . . . . . . . . . . . . . . 23
• Wiring the Main Circuit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
• Wiring the Control Circuit. . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
• Wiring Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
5. OPERATING THE INVERTER . . . . . . . . . . . . . . . . . . . . 28
• Test Run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
• Operating the Digital Operator. . . . . . . . . . . . . . . . . . . . . . . . 30
• LED Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
• Simple Data Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
6. PROGRAMMING FEATURES . . . . . . . . . . . . . . . . . . . . 39
• Parameter Set-up and Initialization . . . . . . . . . . . . . . . . . . . . 39
• Using V/f control Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
• Using Vector Control Mode . . . . . . . . . . . . . . . . . . . . . . . . . . 43
• Switching LOCAL/REMOTE Modes . . . . . . . . . . . . . . . . . . . 46
• Selecting Run/Stop Commands. . . . . . . . . . . . . . . . . . . . . . . 47
• Setting Operation Condition . . . . . . . . . . . . . . . . . . . . . . . . . 50
12
• Selecting Stopping Method . . . . . . . . . . . . . . . . . . . . . . . . . . 71
• Building Interface Circuits with External Devices . . . . . . . . . 73
• Setting Frequency by Current Reference Input . . . . . . . . . . . 83
• Frequency Reference by Pulse Train Input . . . . . . . . . . . . . . 85
• Decreasing Motor Speed Fluctuation . . . . . . . . . . . . . . . . . . 89
• Motor Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
• Selecting Cooling Fan Operation. . . . . . . . . . . . . . . . . . . . . . 92
• Using MEMOBUS (MODBUS) Communications . . . . . . . . . . 92
• Using Parameter Copy Function . . . . . . . . . . . . . . . . . . . . . 116
• Unit Selection for Frequency Reference Setting Display. . . 125
7. MAINTENANCE AND INSPECTION . . . . . . . . . . . . . . 127
• Periodical Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
• Part Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
8. FAULT DIAGNOSIS AND CORRECTIVE ACTIONS . . 129
9. SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
• Standard Specifications (200V Class) . . . . . . . . . . . . . . . . . 139
• Standard Specifications (400V Class) . . . . . . . . . . . . . . . . . 142
• Standard Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
• Sequence Input Connection with NPN/PNP Transistor . . . . 148
• Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
• Recommended Peripheral Devices . . . . . . . . . . . . . . . . . . . 153
• Parameter List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154
APPENDIX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167
• CE Conformance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167
13