Servicing the Timeclock. Kronos 4000 SERIES, Series 4000
تبلیغات
تبلیغات
Chapter 4 Maintaining the Timeclock
Badge Test
Use Badge Test to check a badge or the badge reader. (The Badge test is not part of the “Sequential Tests” function on page 4-56.)
Step Display
1
2
3
Maintenance Mode idle display
Maintenance Mode display
Symboloy
Badge Data
Action
Press the More... soft key.
Press the Badge Test soft key.
Swipe a badge.
Beeper Test
Use Beeper Test to check the Beeper. The beeper will beep twice at two different pitches during this test. (The Beeper test is part of the “Sequential Tests” function on page 4-56.)
Step Display
1
2
3
Maintenance Mode idle display
Maintenance Mode display
Start Test?
Action
Press the More... soft key.
Press the Beeper Test soft key.
Do one of the following:
!
!
Press ENTER to accept the default answer.
Press the toggle soft keys to select YES or NO, and press ENTER.
4-54 ADP, Inc.
Performing Maintenance Functions
Display Test
Use Display Test to check the timeclock display. The timeclock lights up the four quadrants of the display in a pattern during this test. (The Display test is part of the “Sequential Tests” function on page 4-56.)
Step Display
1
2
3
Maintenance Mode idle display
Maintenance Mode display
Start Test?
Action
Press the More... soft key.
Press the Display Test soft key.
Do one of the following:
!
!
Press ENTER to accept the default answer.
Press the toggle soft keys to select YES or NO, and press ENTER.
Keypad Test
Use Keypad Test to check the keypad. (The Keypad test is not part of the
“Sequential Tests” function on page 4-56.)
Step Display
1
2
3
Maintenance Mode idle display
Maintenance Mode display
Key
Action
Press the More... soft key.
Press the Keypad Test soft key.
Type various keys on the keypad, then press ESC to exit the Test Mode.
Series 4000 Badge Timeclock User’s Guide 4-55
Chapter 4 Maintaining the Timeclock
LED Test
Use LED Test to check the timeclock’s LEDs. During the test, the three LEDs in the top right corner of the timeclock flash in sequence twice. (The LED test is also part of the “Sequential Tests” function.) Then, the bottom LED remains lit to indicate that the timeclock is receiving power.
Step Display
1
2
3
Maintenance Mode idle display
Maintenance Mode display
Start Test?
Action
Press the More... soft key.
Press the LED Test soft key.
Do one of the following:
!
!
Press ENTER to accept the default answer.
Press the toggle soft keys to select YES or NO, and press ENTER.
Sequential Tests
Use Sequential Test to run through the Display, LED, and Beeper diagnostic tests.
The test is finished after sounding two pitches for the Beeper test.
Note
You can run each test included in this Sequential Tests function individually, using each test’s own maintenance function.
Step Display
1
2
Maintenance Mode idle display
Maintenance Mode display
Action
Press the More... soft key.
Press the Sequential Tests soft key.
4-56 ADP, Inc.
Performing Maintenance Functions
Change Password
Use Change Password to change the password for a specific Maintenance badge.
2
3
4
Step Display
1
2
Maintenance Mode idle display
Maintenance Mode display
Old Password
New Password
Verify Password
Action
Press the More... soft key three times.
Press the Change Password soft key.
Type the old password for the badge.
Type the new password.
Type the new password a second time.
FACTORY DEFAULT
Use FACTORY DEFAULT to set the Series 4000 timeclock back to the factory defaults.
Warning
Only use the FACTORY DEFAULT settings if your Series 4000 timeclock is not operating properly. You lose all settings and data if you complete this transaction.
Step Display
1
2
3
Maintenance Mode idle display
Action
Press the FACTORY DEFAULT soft key.
FACTORY DEFAULT?
Do one of the following:
!
!
Press ENTER to accept the default answer.
Press the toggle soft keys to select YES or NO, and press ENTER.
Communication Settings display
Restore your Communication Settings. See
“Communication Setting (basic configuration)” on page 4-47.
Series 4000 Badge Timeclock User’s Guide 4-57
Chapter 4 Maintaining the Timeclock
Delete All Punches
Use Delete All Punches to delete all punches from the FIFO to correct the last punch invalid error. For more information, see “Error 04-2: Last punch invalid” in
Chapter 6 on page 6-3. After performing the Delete All Punches transaction, the timeclock contains only home employee data associated with schedule enforcement.
Caution
Performing Delete All Punches causes all transactions stored in the FIFO
(collected and uncollected) to be deleted.
Step Display
1
2
2
Maintenance Mode idle display
Maintenance Mode display
Delete all punches?
Action
Press the More... soft key three times.
Press the Delete All Punches soft key.
Do one of the following:
!
!
Press ENTER to accept the default answer.
Press the toggle soft keys to select YES or NO, and press ENTER.
Restart
Use Restart to restart the Series 4000 timeclock.
Step Display
1
2
Maintenance Mode idle display
Restart?
Action
Press the Restart soft key.
Do one of the following:
!
!
Press ENTER to accept the default answer.
Press the toggle soft keys to select YES or NO, and press ENTER.
4-58 ADP, Inc.
Chapter 5
Upgrading Timeclock Firmware
This chapter contains the following section:
!
!
Overview of a Softload
Performing a Softload
Chapter 5 Upgrading Timeclock Firmware
Overview of a Softload
A communication protocol between Data Collection Manager (DCM) and the
Series 4000 badge timeclock initiates and controls the softload process. The timeclock displays a message indicating that a softload is in progress. All user input is disabled.
DCM performs a Batch first-in-first-out (FIFO) command to collect all uncollected punches from the FIFO database before the download process begins.
Note
Before attempting to upgrade the firmware in your Series 4000 timeclock, check with your ADP TLM Representative or the customer support section of www.adp.com
for the latest firmware information.
5-2 ADP, Inc.
Performing a Softload
Performing a Softload
Before you perform a softload, you should verify that the Data Collection
Manager (DCM) Collection Agent is working. The softload process does not start until the Collection Agent completes the collection process.
Caution
To ensure a successful softload, do not reboot the timeclock while it is in Softload
Mode.
To perform a softload, do the following:
1. Access the DCM Device Manager application.
2. Select Tools > Advanced Device Manager.
3. Select a device or device group in the left pane of the Advanced Device
Manager window.
4. Select Device > Load Firmware.
5. In the Load Firmware Name dialog box, do the following: a.
In the File of types textbox, select .krm.
b. Browse to select the appropriate .krm file.
c.
Click Open.
You can view the status of the softload process in the Request Status window in
Advanced Device Manager. When the softload process is complete, you need to initialize your timeclock. For more information about initializing a timeclock, see the Data Collection Manager System Administrator’s Guide.
Series 4000 Badge Timeclock User’s Guide 5-3
Chapter 5 Upgrading Timeclock Firmware
5-4 ADP, Inc.
Chapter 6
Error Messages and Troubleshooting
Procedures
This chapter provides error and status messages to help isolate the source of malfunctions that occur while the Series 4000 timeclock is operating. It includes the following sections:
!
!
Error Messages—Includes descriptions and solutions for all errors that can be displayed at the timeclock
Troubleshooting—Includes procedures for diagnosing and resolving error conditions, communication, and operational problems
Chapter 6 Error Messages and Troubleshooting Procedures
Error Messages
!
!
The Series 4000 timeclock displays two types of messages that can provide helpful information when you are troubleshooting timeclock malfunctions:
Error Messages
Status Messages
This chapter contains all of the error and status messages that the Series 4000 timeclock can display. It also describes the possible causes of the error message.
Transaction Error Messages
These error conditions are found after a transaction is completed.
Error 01-1: Error reading badge barcode
The timeclock was able to detect that a badge was swiped, but the data on the badge could not be decoded into a barcode. It is possible that the barcode symbology is disabled.
Swipe the badge again. Enable the barcode symbology if applicable.
Error 02-1: Unrecognized badge format
The timeclock was able to decode the data on the badge, but the barcode does not match any of the associated formats. The Series 4000 timeclock accepts only ADP standard badges; any other badge formats (generic barcode badges) must be identified via your host application software. Each step in a transaction has its own set of badge formats, so while the badge format might be known by the timeclock, it is possible it cannot be used for a specific step in a transaction.
Re-enter using a different badge.
6-2 ADP, Inc.
Error Messages
Error 04-1: Punch rejected
The timeclock has detected that the time span since the last punch for this employee does not meet the minimum time between punches. The minimum time is configured using your host application software.
Wait the appropriate amount of time, then punch again.
Error 04-2: Last punch invalid
The date and time of the last punch for this employee is in the future, making schedule enforcement impossible.
Perform a Delete All Punches transaction in Maintenance Mode. For more information, see “Delete All Punches” in Chapter 4 on page 4-58. If data was already collected from the timeclock, you need to correct the data in the host application.
Error 05-1: Punch rejected (xxx)
Schedule enforcement logic has determined that the employee cannot punch. This error includes a reason (xxx) for the rejection.
Values include:
101 - Schedule enforcement is disabled but a repunch error was detected
102 - The restriction profile the employee is assigned to is not available (not downloaded by DCM)
103 - The generic schedule the employee is assigned to is not available (not downloaded by DCM)
104 - The last punch is in the future (see Error 04-2)
105 - Repunch error (see Error 04-1)
106 - An error was found in the data in the generic schedule the employee is assigned to
Series 4000 Badge Timeclock User’s Guide 6-3
Chapter 6 Error Messages and Troubleshooting Procedures
107 - According to the employee's generic schedule, it is a punch off time
108 - The employee is attempting to start a new shift but an individual or generic schedule cannot be found
109 - The employee is attempting to punch before a scheduled start time but earlier than is allowed (early start restriction)
110 - The employee is attempting to punch after the schedule start time but later than is allowed (late start restriction)
111 - The employee is attempting to punch after the schedule end time but later than the maximum time specified in the pay rules (late end restriction)
Do one of the following:
!
!
Swipe the employee badge while the timeclock is in Supervisor Mode.
Enable a single or global restriction credit from Supervisor Mode.
Error 06-1: Valid for home employees only
This transaction can only be performed by home employees, but the employee badge does not match any of the home employees loaded in the timeclock.
Perform this transaction with a home employee badge.
Error 06-2: Unknown home employee
The employee badge does not match any of the home employees loaded in the timeclock and punching by non-home employees is not allowed.
!
!
!
Do one of the following:
!
In the host application, add the employee to the timeclock group and use the host application software to update the timeclock.
In the host application software, allow non-home employees to punch.
Swipe the employee badge while the timeclock is in Supervisor Mode.
Enable a single or global restriction credit from Supervisor Mode.
6-4 ADP, Inc.
Error Messages
Error 08-1: Invalid restriction level
The employee badge does not match any of the home employees loaded in the timeclock, punching by non-home employees is allowed, but not for the restriction level encoded on the badge.
!
!
Do one of the following:
!
In your host application software, allow the restriction level to be used by non-home employees.
Swipe the employee badge while the timeclock is in Supervisor Mode.
Enable a single or global restriction credit from Supervisor Mode.
Error 09-1: Invalid for home employees
The employee badge matches a home employee loaded in the timeclock but this transaction can only be performed by non-home employees.
Do one of the following:
!
!
Re-enter the badge number.
Enable a single or global non-home restriction override from Supervisor
Mode.
Error 36-1: System cannot save data - Contact supervisor
An error was detected when the transaction was being written into the database.
All activity at the timeclock will be suspended.
Contact your TLM Representative.
Error 41-1: Restriction profile not found
The restriction profile the employee is assigned to is not available.
Using your host application software, re-initialize the timeclock.
Series 4000 Badge Timeclock User’s Guide 6-5
Chapter 6 Error Messages and Troubleshooting Procedures
Error 41-2: Generic schedule not found
The generic schedule the employee is assigned to is not available.
Using your host application software, re-initialize the timeclock.
Error 41-3: Generic schedule not valid
An error was found in the data in the generic schedule the employee is assigned to.
Using your host application software, re-initialize the timeclock.
Error 95-1: Password is incorrect
An invalid password has been entered for the supervisor or maintenance badge.
Enter the correct password.
Other Error Messages
Data Error Messages
Data error conditions are detected when you enter the data for a step in a transaction. These are format and content validation errors. The user must correct the rejected data in order to complete the step. These messages appear at the top of the display and the rest of the screen remains the same.
The data error messages are:
!
!
!
!
!
75-1: Enter valid data
91-1: This field is required
92-1: Maximum value is xx
92-2: Minimum value is xx
93-1: Enter a numeric value
6-6 ADP, Inc.
Error Messages
!
!
!
!
!
!
!
!
!
!
!
94-1: Enter a valid date
94-2: Enter a valid time
94-4: Enter xx digits after decimal
94-5: Enter data in decimal format
94-6: Badge data exceeds field length
94-7: Enter a valid IP address
94-8: Enter valid data
96-1: Maximum length is xx
96-2: Minimum length is xx
10-1: Unrecognized barcode
10-2: Use keypad to enter data
Transaction Error Conditions
Transaction error conditions are detected after you enter all the data for a transaction. This is called transaction validation. You must correct all of the data in order to complete the transaction.
The transaction error conditions are:
!
!
!
!
!
91-2: Complete all fields
92-3: Maximum days in future is xx
92-4: Maximum days in past is xx
Effective date must be today or earlier
Error: The override ends in the past
Series 4000 Badge Timeclock User’s Guide 6-7
دانلود