Error Messages. Kronos 4000 SERIES, Series 4000
Below you will find brief information for Series 4000. The Series 4000 badge timeclock collects employee time and attendance data using barcode badges. It offers features like schedule enforcement, employee messaging, and function keys for labor transfers and pay code transactions. It can be used by employees and supervisors, and it provides maintenance functions for configuration and diagnostics.
Advertisement
Advertisement
Troubleshooting
Troubleshooting
This section provides troubleshooting procedures to help you isolate the source of hardware malfunctions that can occur while operating the Series 4000 timeclock.
Troubleshooting procedures are provided for the following types of problems:
!
!
!
Timeclock Hardware Failures
Troubleshooting Table
Verifying the Integrity of the Network
For diagnostic testing, refer to “What Are the Maintenance Functions?” on page 4-43.
Timeclock Hardware Failures
!
!
!
!
!
!
Since error messages do not appear for most hardware failures, you must perform some hands-on troubleshooting to determine their causes. You need the following tools to troubleshoot the Series 4000 timeclock’s hardware:
#0, #1, and #2 Phillips screwdrivers
1/8-inch and 1/4-inch flat blade screwdrivers
A nonmetallic pointed tool
5-32 security-head Allen wrench
AC/DC voltmeter
Ohmmeter
Series 4000 Badge Timeclock User’s Guide 6-9
Chapter 6 Error Messages and Troubleshooting Procedures
!
!
!
!
!
!
You also need the following functioning elements of the front cover assembly. For part numbers, see “Replacing the Backup Battery Charger Board” on page 4-24.
LCD display assembly
DC wall transformer
Keypad
Auxiliary power source (APS)
Remote swipe bar code badge reader
Ethernet option board
Troubleshooting Table
The following table summarizes the steps that you should follow when troubleshooting the Series 4000 timeclock’s hardware. For additional information, contact your TLM Representative.
Symptom Probable Cause Corrective Action
The power LED is turned on, but nothing appears on the screen.
Display’s cable is not connected to mainboard.
Display board is malfunctioning.
Make sure cable is connected to the mainboard.
Replace the front cover assembly. Contact your TLM Representative.
Mainboard is malfunctioning.
Replace the Field Replaceable Unit (FRU).
Contact your TLM Representative.
Run the Display Test.
1. Access Maintenance Mode.
2. Press the More soft key.
3. Press the Display Test soft key.
4. Press ENTER to start the test and note the result.
5. Contact your TLM Representative.
6-10 ADP, Inc.
Troubleshooting
Symptom Probable Cause Corrective Action
The Series 4000 timeclock does not power up, and the power LED is not turned on.
The transformer is not plugged in properly to the timeclock’s main board, the AC outlet, or both.
Check the connections to the main board and the AC outlet.
Important: If the power cord is not plugged into the AC outlet, do not plug it in until you ensure that the transformer is properly connected to the main board.
For instructions, see “Supplying Power to the Timeclock” in the Series 4000 Badge
Timeclock Installation Guide.
Restore power.
No power available to
AC outlet.
While running on backup battery power, the backup battery expired.
Restore power via AC outlet.
Poor connection to the main board.
Bad cable.
Check the connections to the main board.
Power LED is off
Power supply is bad.
LED indicator light is burned out.
Run the LED test.
Replace cable. Contact your TLM
Representative.
Replace power supply. See “Replacing the
AC Power Supply (transformer)” in
Chapter 4 on page 4-40.
Replace the front cover assembly. Contact your TLM Representative.
1. Access Maintenance Mode.
2. Press the More soft key.
3. Press the LED Test soft key.
4. Press ENTER to start the test and note the result.
5. Contact your TLM Representative.
Series 4000 Badge Timeclock User’s Guide 6-11
Chapter 6 Error Messages and Troubleshooting Procedures
Symptom Probable Cause Corrective Action
No LCD backlight The contrast and brightness of the display screen are not appropriate for the timeclock’s environment.
Adjust the contrast and brightness of the display screen. See “Display Setting (basic configuration)” on page 4-49.
Keypad fails to work
Lead-acid battery failure
The keypad’s ribbon cable is improperly connected to mainboard.
If you can, determine the exact nature of the problem (for example, is the cable twisted or cut?), then contact your TLM
Representative.
Run the Keypad test.
1. Access Maintenance Mode.
2. Press the More soft key.
3. Press the Keypad Test soft key.
4. Type various keys on the keypad.
5. Note which key or keys fail to work.
6. Contact your TLM Representative.
Reinstall according to specifications.
The battery backup option is improperly installed.
Battery backup board battery-charging circuit is not functioning properly.
Replace with functioning battery backup board. Contact your TLM Representative.
Battery is defective.
Poor connections.
Replace with a functioning battery.
Contact your TLM Representative.
Check connections.
6-12 ADP, Inc.
Troubleshooting
Symptom
Series 4000 timeclock fails to read badges.
Probable Cause Corrective Action
The badge is unreadable or does not meet the required badge specification.
1. Inspect the badge for cleanliness.
2. Clean the badge and badge reader.
PIN punching only is enabled.
The bar code on the badge is worn or scraped off.
Using Data Collection Manager (DCM), enable badge punching.
Replace the badge.
You did not configure the timeclock to read the symbology encoding your badges use.
1. Access Maintenance Mode.
2. Press the Symbology Setting soft key.
3. Turn on the appropriate symbology.
The timeclock is not enabled for the correct badge reader type or company ID code (if you are using a code).
The badge reader may not be working correctly.
Using Data Collection Manager (DCM), correct the badge reader and company ID code settings.
Run the Badge Test test:
1. Access Maintenance Mode.
2. Press the More soft key to display the test functions.
3. Press the Badge Test soft key.
4. Follow the prompts to conduct the test and note the result.
If the test does not indicate a problem, run a Reader Report:
1. Access Maintenance Mode.
2. Press the More soft key twice.
3. Press the Reader Report soft key.
Note the report results and contact your
TLM Representative.
Series 4000 Badge Timeclock User’s Guide 6-13
Chapter 6 Error Messages and Troubleshooting Procedures
6-14
Symptom
Communication fails.
Probable Cause Corrective Action
Communication settings are incorrect either at the timeclock or the host
PC.
To check settings at the timeclock:
1. Access Maintenance Mode.
2. Press the Communication Settings soft key.
3. Check and, if necessary, correct the
Device ID, IP Address, Gateway, and
Subnet Mask settings.
If communication continues to fail, check the communication settings at the host PC.
Refer to the documentation for your ADP host application.
Communications cabling is connected incorrectly.
Ensure that all communications cables are routed correctly and connected properly.
If the connections are secure, determine whether the cable is defective by doing the following:
!
Check to see if the green communications LED on the Series
4000 timeclock is lit. Use the security wrench to unlock and open the cover of the timeclock. The green LED is located inside the cover and to the left of the Ethernet connection on the main board.
!
Check to see if the green link light on the hub to which the timeclock is connected.
If both lights are lit, the cable is not defective. The problem may lie in the network configuration.
If both lights are not lit, the cable may be defective.
Consult with your system administrator to resolve the problem.
Poor connections.
Bad mainboard.
Check connections.
Replace the Field Replaceable Unit (FRU).
Contact your TLM Representative.
ADP, Inc.
Troubleshooting
Verifying the Integrity of the Network
Verify the integrity of the Series 4000 timeclock’s communications capabilities by following these steps:
1. Perform a general inspection of the installation site. Ensure that all communications cables are routed properly and are securely connected to the timeclock(s), the host PC, and any other ADP equipment that may be installed at the site.
2. Inspect the cables. Make sure they are properly attached.
3. Check wires for any breaks.
4. Using a lap top connected to the Series 4000 timeclock’s Ethernet external jack, PING the host PC.
If there are any communication problems, take appropriate action to resolve them.
For more information, contact your TLM Representative.
Series 4000 Badge Timeclock User’s Guide 6-15
Chapter 6 Error Messages and Troubleshooting Procedures
6-16 ADP, Inc.
Appendix A
Timeclock Specifications
Case:
Dimensions:
Weight:
Keypad:
Black, advanced polycarbonate/ABS resin, dust and moisture-resistant
Width: 10.75 inches (27.30 cm)
Height: 11.75 inches (29.85 cm)
Depth: 4 inches (10.16cm)
5 lbs. (2.25 kg)
Silicon Elastomer numeric keypad and 8 programmable soft keys
Power Supply:
Power requirements:
50/60 Hz 110/220 V transformer
100 to 240V, 1.5A maximum
Display: 4 x 40 FSTN LCD
Host communications: 10/100 Mbit auto-sensing Ethernet
CPU:
Memory:
ESD Protection:
Motorola MPC 860DT
16 MB RAM, upgradeable to 64 MB
8 MB Flash, ability to upgrade to 100 MB
Integrated bar code badge reader Badge Reader:
Battery Backup: Optional, 12 VDC lead acid battery to provide the timeclock up to two hours of full functioning operation
Operating Environment: Temperature: 0 to 40 o
Celsius (32 to 104 o
Fahrenheit)
Humidity: 10% to 95% non-condensing
Shock: Withstands 40 Gs of force when packed in original shipping carton
Withstands 20 kV electrostatic discharge without failures
Appendix A Timeclock Specifications
AC Surge Protection:
FCC:
Approvals:
Timeclock withstands AC power surges induced by lightning, the local power company, or inductive switching transients as tested in accordance with IEEE Standard 587
Meets all Federal Communications Commission (FCC) requirements for Class A computing device
Underwriter’s Laboratories (UL)
Canadian Standards Association (CSA)
A-2 ADP, Inc.
Appendix B
Differences Between the Series 4000 and the Series
400 Timeclocks
!
!
This appendix contains information about the differences between the Series 400 timeclocks and the Series 4000 timeclock. This appendix contains the following sections:
Physical Differences
Functional Differences
Appendix B Differences Between the Series 4000 and the Series 400 Timeclocks
Physical Differences
The following table shows the physical differences between the Series 4000 and the Series 400 timeclocks.
Series 4000
Display 4.7”, 1/4 VGA LCD
Configurable soft keys using DCM
14 Employee Mode
14 Supervisor Mode
Device message length 40 character
Host communications 10/100 Mbit auto-sensing
Ethernet
Memory 16 MB RAM, upgradeable to
64 MB
8 MB Flash, ability to upgrade to 100 MB
Series 400
2 X 20 LCD
Used command numbers to perform functions
20 characters
N/A
128 kilobytes up to 256 kilobytes
B-2 ADP, Inc.
Functional Differences
Functional Differences
The following table shows the functional differences between the Series 4000 and the Series 400 timeclocks.
Series 4000 Series 400
Punch status information display
Individual employee information display
Users can view punch status.
Users can view punches, elapsed time, and last punch.
Users can display individual employee information.
Users can display and print individual employee information.
Keying in a punch Users enter the badge number only.
Supervisor functions Supervisor uses soft keys to initiate functions.
Restriction override repunch interval field
Users press the * key before entering the badge number.
Supervisors enter command numbers to initiate functions.
Timeclock configuration
Installation and maintenance
A ‘1’ interval means a one minute restriction, a ‘2’ interval means a two minute restriction, and so on.
A ‘0’ interval means a oneminute restriction, a ‘1’ interval means a two-minute restriction, and so on.
Users configure timeclocks in their host application software, such as DCM
Users configure timeclocks using AFT commands.
Performed by customer.
Performed by TLM
Representatives.
Series 4000 Badge Timeclock User’s Guide B-3
Appendix B Differences Between the Series 4000 and the Series 400 Timeclocks
B-4 ADP, Inc.
Glossary
The following is a list of terms related to the use and configuration of the Series 4000 timeclock.
10BASE-T
Specifications of the speed of data transmission on an Ethernet network.
10BASE-T represents 10 megabits per second.
100BASE-T
Specifications of the speed of data transmission on an Ethernet network.
100BASE-T represents 100 megabits per second.
account transfer
Employees' hours that are associated with an account other than their home account. accrual field
Storage area for the total of a type of “non-productive” time that employees can accrue. Examples of non-productive time are vacation, sick, and personal time. accruals
Allow you to track “non-productive” hours that employees accrue over time.
Examples of non-productive hours are vacation, sick, and personal time. You create accrual fields for each type of non-productive time and assign them to employees.
Glossary activity code
Allows employees who work special shifts to change activities in the eTIME application or at the timeclocks. For example, a “Charge Nurse” in a hospital is a nurse assigned temporary responsibility for his or her floor. The Charge Nurse is paid differently for taking on this responsibility. You can create activity codes and set up employees' pay rules to award bonus hours or money for activity shifts, according to your payroll policies.
American Banking Association (ABA) track
The magnetic stripe track for the ABA. The ANSI/ISO Track 2 is encoded at 75 bits per inch (bpi) density in binary coded decimal (bcd) format.
American National Standards Institute (ANSI)
Organization that coordinates a variety of standards activities in the United States and serves as a representative to the ISO and the IEC standard bodies.
backlight
The degree of luminosity (brightness) of the timeclock’s display. You set this as part of the local configuration of the timeclock.
barcode reader
A device that reads and interprets bar code symbologies on employee badges. A bar code reader is shipped as an integral part of the Series 4000 timeclock.
barcode wand
Bar code reader wand that you connect to the Series 4000 timeclock’s main board using an RJ-41 connector.
basic configuration
Settings you specify at the timeclock to establish proper communication with the host application, time and date, and the appearance of the display.
brightness
The radiance or luminosity of a visible object.
Glossary-2 ADP, Inc.
Glossary
Codabar
A bar code symbology used for ID cards, blood banks, and some package delivery carriers.
Code 39
A bar code symbology used for industrial, medical, and government applications.
Code 128
A bar code symbology endorsed by several industry trade groups and used widely in manufacturing, especially in Europe.
contrast
The degree of difference between light and dark extremes of color on the timeclock’s display. You set this as part of the local configuration of the timeclock.
Ethernet
Widely used LAN technology. Defined by the IEEE 802.3 specification.
European Article Numbering (EAN)
The EAN-8 and EAN-13 bar code symbologies that have a character set consisting of the numeric characters 0 through 9 and a check digit.
FIFO (first-in-first-out)
A storage retrieval method or buffering scheme in which the data that enters the buffer or storage medium first is the first to be retrieved.
File Transfer Protocol (FTP)
An industry-standard protocol used to transfer files to and from a remote computer.
flash memory
A constantly charged memory in which each bit of data is stored in a cell or transistor as one of two voltage levels.
Series 4000 Badge Timeclock User’s Guide Glossary-3
Glossary function
Operations you perform at the timeclock to view and edit employee data (for example, add punches, display totals).
function key
Data Collection Manager (DCM) equivalent to a soft key.
generic schedule
A pattern of shifts that applies seven days a week. Generic schedules are an easyto-maintain pattern of expected start times that are the same every day. Use these schedules for employees who generally work the same hours every day and for whom a precise control of start and stop times is not important.
home labor account
The main labor account (also called a “cost center”) in which an employee's worked hours accrue. When a supervisor adds an employee in the host application, the supervisor assigns the employee a “home” account. The employee’s worked hours apply to this account unless he or she performs an account transfer when punching in.
host application
The ADP software application for which the timeclock is collecting information.
You use the host application to update the timeclock with new employee information and collect punches and transactions from the timeclock.
International Air Transport Association (IATA) track
The magnetic stripe track for the IATA. The ANSI/ISO Track 1 is encoded at 210 bits per inch (bpi) density in ALPHA format.
International Electrotechnical Commission (IEC)
A voluntary organization that focuses on the technical aspects of electricity.
Interleaved 2-of-5
A popular bar code symbology used frequently in shipping, warehousing, and medical fields.
Glossary-4 ADP, Inc.
Glossary
Internet Protocol (IP) address
A number typically written as four numbers separated by periods that uniquely identifies a computer that is using Transmission Control Protocol/Internet
Protocol (TCP/IP) to communicate across an Internet. The address consists of the network number, the subnet number, and the machine number.
International Organization of Standardization (ISO)
A voluntary organization that facilitates the international interchange of goods and services and encourages cooperation in economic, intellectual, technological, and scientific endeavors.
internal AC outlet
An optional device that you can install inside the timeclock and connect to an AC power line. This eliminates the need to install an AC outlet in the wall.
linear imager
Hand-held scanning device for reading bar codes that you connect to the Series
4000 timeclock’s main board.
labor account
Labor accounts (also called “cost centers”) are where employees' worked hours accrue. Each employee is assigned a home account to which his or her hours accrue, unless a shift is an account transfer. Accounts consist of up to seven labor levels to allow you to clearly define the account. Your hierarchy should start with a general description and get more specific. labor entry
Unit that defines one level of a given labor account.
Labor accounts (also called “cost centers”) consist of up to seven labor levels.
Labor entries associated with each level contribute to defining the labor account. labor level
Labor levels make up the structure of labor accounts (“cost centers” to which employees' hours accrue). Your labor account structure can consist of up to seven labor levels.
Series 4000 Badge Timeclock User’s Guide Glossary-5
Glossary labor tracking
Labor tracking allows users to define precise labor accounts to which employees' hours accrue, and track hours worked in each labor account. local configuration
See basic configuration.
local area network (LAN)
A network system confined to a small geographical area that does not use longdistance carriers, such as telephone connections. The area is usually limited by the cable length restrictions of the transportation media being used.
Network File System (NFS)
A distributed file system that allows users to access remote files and directories on a network as if they were local.
password
A code used to secure access to device configuration.
pay code
Holds worked hours and tells the host application how to calculate wages for those hours. In your system, all possible types of hours that employees can work
(regular, overtime, premium, and so on) are set to accrue in the appropriate pay codes to comply with your organization's pay policies. You can also set up pay codes to hold money to accommodate tips and bonuses.
pay period
Period of time for which employees are paid on a regular basis. Pay periods that the host application supports are weekly, bi-weekly, four weeks, semi-monthly, and monthly.
personal identification number (PIN)
A number that is entered manually into a system to identify an employee.
punch
A punch registers, using a data collection device, employees’ attendance at work, and their hours worked.
Glossary-6 ADP, Inc.
Glossary
Employees “punch” when starting or ending a shift, meal, or break. Employees can punch in a variety of ways, depending on your system. The most common way to punch is by swiping a badge at a Series 4000 timeclock.
proxy server
A program that handles communications between a protected network and the
Internet. This program typically verifies users and keeps a list of accesses.
quiet zone
In a bar code symbology, a quiet zone is a space that can precede the start pattern or follow the stop pattern. Quiet zones can sometimes be part of each symbol.
remote configuration
Involves using the host application to set up domains (timeclock groups), define communication channels, and configure features for each timeclock. You also use the host application to enter and download information to the timeclock (for example, employee list, labor entry list, labor account list).
security screw
Screw on the side of the timeclock used to lock and unlock the timeclock cover.
You use a security screw wrench (supplied with the timeclock) to loosen and tighten the screw.
soft keys
Keys on the timeclock, located immediately to the left and right of the timeclock display. The keys are used to gain access to local configuration screens, and initiate functions and transactions at the timeclock.
subnet mask
Numbers included in the IP address that are used to route a packet through the gateways. Subnet masking allows routers to move the packets more quickly.
symbology
A bar code designed for different purposes. Each bar code adheres to a set of standards or specifications so that different devices can read the same bar codes.
Series 4000 Badge Timeclock User’s Guide Glossary-7
Glossary
Transmission Control Protocol and Internet Protocol (TCP/IP)
A two-layered communications protocol suite that connects different types of computers to various types of media, while providing data correction, security, and reliability.
Transmission Control Protocol (TCP): A protocol in the TCP/IP suite that manages the assembling of a message or file into smaller packets that are transmitted over the Internet and received by a TCP layer that reassembles the packets into the original message.
Internet Protocol (IP): A protocol that handles the address of each packet so that it gets to the right destination.
transaction
An operation employees perform at the timeclock, such as adding a punch and performing a labor account transfer. Personnel with supervisor badges can perform the same functions for one or more employees, when necessary.
Universal Product Code (UPC)
The UPC-A and UPC-E badge symbologies that have a character set consisting of the numeric characters 0 through 9 and a check digit.
Glossary-8 ADP, Inc.
A activity transactions end 2-4 start 2-9 add punch transaction 3-5 audio setting transaction 4-46
B badge reader adjusting slot width 4-32 cover replacing 4-38 removing the reader spacers 4-32 troubleshooting 6-13 badges change maintenance password 4-57 change supervisor password 3-6 symbology setting transaction 4-50 test transaction 4-54 bar code badge test transaction 4-54 readers report transaction 4-53 symbology setting 4-50 basic configuration audio setting transaction 4-46 communication setting transaction 4-47 date/time setting transaction 4-48 display setting transaction 4-49 performing 4-20 symbology setting 4-50 batteries lead-acid 4-7 lithium 4-6 replacing lithium battery 4-6 beeper test transaction 4-54
C cancel meal deduction transaction 2-4 care of the timeclock 4-5 change password transactions maintenance badge 4-57 supervisor 3-6 communication setting transaction 4-47 troubleshooting 6-14 cover assembly, removing 4-11 cross-punching 1-8
D data error messages 6-6 database report transaction 4-51 date/time setting transaction 4-48 delete all punches transaction 4-58 delete punch transaction 3-7 device ID 4-20 device status report transaction 4-51 diagnostic tests badge 4-54 beeper 4-54 display 4-55
Index
Index keypad 4-55
LEDs 4-56 sequential 4-56 differences from Series 400 timeclock functional A-3 physical A-2 display on/off premise transaction 3-8 setting transaction 4-49 test transaction 4-55
E employee mode 2-2 transactions 2-3 view information transaction 3-12 end activity transaction 2-4 enter tips transaction 2-5 error messages data errors 6-6 status messages 6-8 transaction error conditions 6-7 transaction errors 6-2 ethernet report transaction 4-52
F
FACTORY DEFAULT transaction 4-57 file system report transaction 4-52 functional differences from Series 400 A-3 functions cross-punching 1-8 employee 2-2 maintenance 4-46 supervisor 3-2
G gateway 4-20 global restriction override transactions home employee 3-8 non-home employee 3-9
H hours pay code adjustment transaction 3-10 pay code edit transaction 2-6
I interior diagram 4-9
IP address 4-20
K key click 4-22 keypad problems 6-12 test transaction 4-55 using 1-12
L labor transfer transaction 2-5
LCD failure 6-12 lead-acid battery about 4-7 failure 6-12 recharging time 4-7
LED failure 6-10, 6-11 test transaction 4-56 lithium battery about 4-6 replacing 4-6
Index-2 ADP, Inc.
Index
M maintenance functions 4-46 mode 4-43 preventive 4-5 replacement parts 4-4 required tools 4-2 safety considerations 4-3 servicing the timeclock 4-8 transactions 4-44 maintenance functions diagnostic tests 4-44 miscellaneous 4-44 reports 4-44 settings 4-44 maintenance mode accessing 4-45 example 4-43 exiting 4-45 meals, cancel deduction transaction 2-4 memory report transaction 4-53 messages, view all transaction 2-9 modes employee 2-2 maintenance 4-43 supervisor 3-2
P part numbers 4-4 password transactions changing maintenance 4-57 changing supervisors 3-6 pay code hours adjustment transaction 3-10 hours edit transaction 2-6 money edit transaction 2-7 pay code hours adjustment transaction 3-10 physical differences from Series 400 A-2 power-up failures 6-11 preventive maintenance about the lead acid battery 4-7 about the lithium battery 4-6 cleaning the badge reader 4-5 cleaning the case and keyboard 4-5 cleaning the timeclock 4-5 punches add punch transaction 3-5 cross-punching 1-8 delete punch transaction 3-7 review punches transaction 2-8 simple punch transaction 2-8 view punch status transaction 2-11
R readers removing the spacers 4-32 report transaction 4-53 replacement parts, obtaining 4-4 reports database transaction 4-51 device status transaction 4-51 ethernet transaction 4-52 file system transaction 4-52 memory transaction 4-53 readers transaction 4-53 restart function transaction 4-58 restriction override transaction global home employee 3-8 global non-home employee 3-9 single home employee 3-11 single non-home employee 3-12 review punches transaction 2-8
S safety considerations 4-3 schedule view current transaction 2-10 view future transaction 2-10 security screw, loosening 4-11
Series 4000 Badge Timeclock User’s Guide Index-3
Index sequential test transaction 4-56
Series 400 functional differences from A-3 physical differences from A-2 settings audio transaction 4-46 communications transaction 4-47 date/time transactions 4-48 display transaction 4-49 symbology transaction 4-50 simple punch transaction 2-8 single restriction override transaction home employee 3-11 non-home employee 3-12 spacers, removing from timeclock 4-32 specifications A-1 start activity transaction 2-9 status messages 6-8 subnet mask 4-20 supervisor functions 3-2 transactions 3-3 supervisor mode accessing 3-4 example 3-2 exiting 3-4 symbology setting transaction 4-50
T test transactions badges 4-54 beeper 4-54 display 4-55 keypad 4-55
LED 4-56 sequential 4-56 timeclock interior diagram 4-9 restart function 4-58 safety considerations 4-3 servicing 4-8 timeclock care cleaning the badge reader 4-5 cleaning the case 4-5 cleaning the keyboard 4-5 timeclock cover, locking/unlocking 4-11 timeclock keypad, using 1-12 timeclock service 4-8 adjusting width of badge reader slot 4-32 handling static-sensitive components 4-3 obtaining replacement parts 4-4 performing basic configuration 4-20 removing cover assembly 4-11 removing the reader spacers 4-32 replacing AC power supply 4-40 replacing backup battery charger board 4-24 replacing badge reader cover 4-38 replacing lithium battery 4-6 replacing transformer 4-40 returning cover assembly 4-10, 4-14 transaction error conditions 6-7 messages 6-2 transactions employee 2-3 maintenance 4-44 supervisor 3-3 transfer transactions,labor 2-5 troubleshooting badge-read problems 6-13 communication problems 6-14 data error messages 6-6
Index-4 ADP, Inc.
display failure 6-10
FACTORY DEFAULT transaction 4-57 hardware/operational problems 6-10 to 6-14 keypad problems 6-12
LCD failure 6-10, 6-12 lead-acid battery failure 6-12
LED failure 6-10, 6-11 power-up failures 6-11 status messages 6-8 transaction error conditions 6-7 transaction error messages 6-2
V view current schedule transaction 2-10 future schedule transaction 2-10 totals transaction 2-11 view all messages transaction 2-9
Index
Series 4000 Badge Timeclock User’s Guide Index-5
Index
Index-6 ADP, Inc.
Download
Advertisement
Key features
Collects employee time and attendance data using barcode badge reader and keypad
Supports schedule enforcement and employee messaging
Offers function keys for various transactions
Provides supervisor functions for punch management and employee information viewing
Includes maintenance functions for diagnostics and configuration
Features a 1/4 VGA LCD for displaying information
Frequently asked questions
Swipe your badge through the barcode reader, and the timeclock will record your punch.
Press the Labor Transfer soft key, enter the labor levels, and swipe your badge.
Press the View Current Schedule soft key to display your schedule.
Press the Enter Tips soft key, and enter tip amount, swipe your badge.
Press the Start Activitiy soft key, and swipe your badge.