5. WIRING
• Wiring Instructions
(1) Always connect the power supply via a molded-case circuit breaker (MCCB) to the power input terminals R/L1, S/L2, and T/L3 (R/L1, S/L2 for single-phase). Never connect the power supply to U/T1, V/T2, W/T3,-,+1 or +2.
The single-phase (200V class) inverter can be connected to a 200V 3-phase input.
However, when a single-phase supply is used, never use the terminal T/L3 for other purposes.
Inverter Power Supply Connection Terminals
200V 3-phase Input Power Supply
Specification Product
CIMR-J7!!2!!!
Connect to R/L1, S/L2, T/L3
200V Single Input Power Supply
Specification Product.
CIMR-J7!!B!!!
Connect to R/L1, S/L2
400V 3-phase Input Power Supply
Specification Product.
CIMR-J7!!4!!!
Connect to R/L1, S/L2, T/L3
(2) Connect the motor wiring to terminals U, V, and W on the main circuit output side
(bottom of the inverter).
(3) If the wiring distance between inverter and motor is long, reduce the inverter carrier frequency. For details, refer to “Reducing motor noise or leakage current
(n46)” on page 79.
(4) Control wiring must be less than 164ft(50m) in length and separate from the power wiring. Use twisted-pair shielded wire when inputting the frequency signal externally.
(5) Tighten the screws on the main circuit and control circuit terminals.
(6) Do not connect or disconnect wiring, or perform signal checks while the power supply is turned ON.
• Wire and Terminal Screw Sizes
1. Control Circuit
Model
Common to all models
Terminal Symbol
MA, MB, MC
S1 to
S5,SC,FS,FR,FC,AM,AC
Screw
M3
M2
Wire
Tightening
Torque lb • in (N • m)
Applicable size
4.44 to 5.33
(0.5 to 0.6)
1.94 to 2.21
(0.22 to 0.25) mm
2 twisted wire 0.5 to 1.25
single 0.5 to 1.25
twisted wire 0.5 to 0.75
single 0.5 to 1.25
AWG
20 to 16
20 to 16
20 to 18
20 to 16
Recommend size mm
2 AWG
Type
0.75
18 Shielded
0.75
18 wire or equivalent
39
2. Main Circuit
200V Class 3-phase Input Series
Model
CIMR-J7*U20P1
Terminal Symbol
R/L1,S/L2,T/L3,-,+1,+2,U/T1,V/T2,W/T3
Screw
M3.5
Tightening
Torque lb • in
(N • m)
7.1 to 8.88
(0.8 to 1.0)
Applicable size mm
2
Recommended
AWG mm
2 size
AWG
0.75 to 2
18 to
14
2
Wire
14
CIMR-J7*U20P2
R/L1,S/L2,T/L3,-,+1,+2,U/T1,V/T2,W/T3
M3.5
7.1 to 8.88
(0.8 to 1.0)
0.75 to 2
18 to
14
2
CIMR-J7*U20P4
CIMR-J7*U20P7
R/L1,S/L2,T/L3,-,+1,+2,U/T1,V/T2,W/T3
R/L1,S/L2,T/L3,-,+1,+2,U/T1,V/T2,W/T3
M3.5
M3.5
7.1 to 8.88
(0.8 to 1.0)
7.1 to 8.88
(0.8 to 1.0)
0.75 to 2
0.75 to 2
18 to
14
18 to
14
2
2
CIMR-J7*U21P5
CIMR-J7*U22P2
R/L1,S/L2,-,+1,+2,U/T1,V/T2,W/T3
R/L1,S/L2,-,+1,+2,U/T1,V/T2,W/T3
M3.5
M3.5
7.1 to 8.88
(0.8 to 1.0)
7.1 to 8.88
(0.8 to 1.0)
2 to 5.5
2 to 5.5
14 to
10
14 to
10
2
3.5
CIMR-J7*U23P7
R/L1,S/L2,-,+1,+2,U/T1,V/T2,W/T3
M4
10.7 to 13.3
(1.2 to 1.5)
2 to 5.5
14 to
10
5.5
Note: The wire size indicated is for copper wires at 160
°
F (75
°
C)
14
14
14
14
14
10
Type
600V vinylsheathed wire or equivalent
200V Class Single-phase Input Series
Model Terminal Symbol Screw
Tightening
Torque lb • in
(N • m)
Wire
Applicable size mm
2
Recommended
AWG mm
2 size
AWG
Type
CIMR-J7*UB0P1
CIMR-J7*UB0P2
CIMR-J7*UB0P4
R/L1,S/L2,T/L3,-,+1,+2,U/T1,V/T2,W/T3
R/L1,S/L2,T/L3,-,+1,+2,U/T1,V/T2,W/T3
R/L1,S/L2,T/L3,-,+1,+2,U/T1,V/T2,W/T3
M3.5
M3.5
M3.5
7.1 to 8.88
(0.8 to 1.0)
7.1 to 8.88
(0.8 to 1.0)
7.1 to 8.88
(0.8 to 1.0)
0.75 to 2
0.75 to 2
0.75 to 2
18 to
14
18 to
14
18 to
14
2
2
2
14
14
14
CIMR-J7*UB0P7
R/L1,S/L2,T/L3,-,+1,+2,U/T1,V/T2,W/T3
M4
7.1 to 8.88
(0.8 to 1.0)
2 to 5.5
14 to10
3.5
2
12
14
CIMR-J7*UB1P5
R/L1,S/L2,T/L3,-,+1,+2,U/T1,V/T2,W/T3
M4
7.1 to 8.88
(0.8 to 1.0)
2 to 5.5
14 to
10
5.5
2
Note: The wire size indicated is for copper wires at 160
°
F (75
°
C)
10
14
Note: Three-phase input is also acceptable for single-phase input series.
600V vinylsheathed wire or equivalent
40
400V Class 3-phase Input Series
Model
CIMR-J7*U40P2
Terminal Symbol
R/L1,S/L2,T/L3,-,+1,+2,U/T1,V/T2,W/T3
Screw
M3.5
Tightening
Torque lb • in
(N • m)
7.1 to 8.88
(0.8 to 1.0)
Applicable size mm
2
Recommended
AWG mm
2 size
AWG
2 to 5.5
14 to
10
2
Wire
14
CIMR-J7*U40P4
CIMR-J7*U40P7
CIMR-J7*U41P5
R/L1,S/L2,T/L3,-,+1,+2,U/T1,V/T2,W/T3
R/L1,S/L2,T/L3,-,+1,+2,U/T1,V/T2,W/T3
R/L1,S/L2,T/L3,-,+1,+2,U/T1,V/T2,W/T3
M3.5
M3.5
M3.5
7.1 to 8.88
(0.8 to 1.0)
7.1 to 8.88
(0.8 to 1.0)
7.1 to 8.88
(0.8 to 1.0)
2 to 5.5
2 to 5.5
2 to 5.5
14 to
10
14 to
10
14 to
10
2
2
2
CIMR-J7*U42P2
R/L1,S/L2,T/L3,-,+1,+2,U/T1,V/T2,W/T3
M4
10.65 to 13.31
(1.2 to 1.5)
2 to 5.5
14 to
10
2
CIMR-J7*U43P0
R/L1,S/L2,T/L3,-,+1,+2,U/T1,V/T2,W/T3
M4
10.65 to 13.31
(1.2 to 1.5)
2 to 5.5
14 to
10
2
3.5
CIMR-J7*U43P7
R/L1,S/L2,T/L3,-,+1,+2,U/T1,V/T2,W/T3
M4
10.65 to 13.31
(1.2 to 1.5)
2 to 5.5
14 to
10
2
3.5
Note: The wire size indicated is for copper wires at 160
°
F (75
°
C)
14
14
14
14
14
12
14