Installation Specifications
•
•
•
WARNING
IMPORTANT: Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information.
To reduce the risk of a fire hazard, all minimum/maximum clearances shown must be met or exceeded.
When installing model ETT365-2 or METB365-1 and the bottom of the chassis is to be enclosed wall to wall, you must install ventilation duct kit ATD323. See the duct installation instructions for cutout requirements.
Planning the Location
•
•
•
•
Dacor recommends installing a non-combustible material on the rear wall behind the cooktop.
Carefully check the location where the cooktop is to be installed. It should be placed for convenient access.
To reduce the risk of personal injury caused by reaching over a hot appliance, cabinet storage space located directly above the cooktop should be avoided.
Make certain that electrical power meeting the specifications on page 3 can be provided in the selected location. Verify that the electrical location is permitted by local building codes. Locate the junction box within reach of the included 48 inch long (1219 mm) cooktop power conduit attached at the bottom right rear of the chassis. Do not lengthen the wiring. Make sure the underside of the cooktop and the junction box are accessible for inspection and service.
Cabinet Layout
Ventilation
To reduce the risk of personal injury and to reduce accumulated smoke in the room, Dacor strongly recommends installing a vent hood or raised vent. Install the vent hood or raised vent according to the accompanying installation instructions. A vent hood should cover the entire cooking surface below it.
If installing the cooktop with a raised vent, install only the following approved Dacor model numbers:
Cooktop Models
ETT304-1 MET304
ETT365-2 METB365-1
Approved Raised Vent Models
ERV30, PRV30 or RV30
ERV36, PRV36 or RV36
Raised vent installation must allow room for the stiffener bar on the back of the raised vent chassis. See below.
Stiffener
3/8” Min. (10 mm) flat countertop overhang required behind cutout
Countertop
ETT or MET series cooktop
Cabinet face
3/8” Min. (10 mm) space behind raised vent chassis to clear stiffener
ERV or PRV series raised vent: Check raised vent dimensions/specifications to determine proper fit
Floor
Side View: Cooktop and ERV/PRV Series Raised Vent
Under Counter Clearance
• Allow a minimum of six(6) inches (152 mm) clearance between the base of the glass cooktop frame and any combustible surface below, including the upper edge of drawers below the cooktop. Proper under-cabinet clearance is also required for the cooktop hold down brackets.
Stiffener
5/8” Min. (16 mm) flat countertop overhang required behind cutout
Countertop
ETT or MET series cooktop
A
6” (152 mm)
Min. clearance to combustible surfaces
Cooktop Models
ETT304-1, MET304
ETT365-2, METB365-1
A - Minimum Under Counter
Clearance (Width)
30 1/2” (775 mm)
36 1/2” (927 mm)
Under Counter Clearance - All Installations
Cabinet face
5/8” Min. (16 mm) space behind raised vent chassis to clear stiffener
RV series raised vent:
Check raised vent dimensions/specifications to determine proper fit
Floor
Side View: Cooktop and RV Series Raised Vent
Installation Specifications
Cabinet Cutout Dimensions
Before making the countertop cutout, make certain that the required dimensions shown below have been met or exceeded.
All tolerances: +1/16, -0 (+1.6 mm, -0). unless otherwise stated.
Rear wall
Dimension Table -
Installations without Raised Vent
Models
A - Cooktop
Cutout Width
ETT304-1, MET304 28 3/4” (730 mm)
6" (152 mm) Min. from mounting surface to combustibles below cooktop chassis
A
ETT365-2, METB365-1 34 3/4” (883 mm)
2 1/4" Min.
(57 mm)
19 3/4" Min.
(502 mm)
1" Min.
(25 mm)
Countertop Cutout Dimensions Without a Raised Vent Installed
ISO view without raised vent
6" (152 mm)
Min. to combustible, side wall, both sides
D B
E
Rear wall
C
19 3/4"
(502 mm)
6" Min.
(152 mm)
Cabinet face
1" Min.
(25 mm)
6" (152 mm) Min. from mounting surface to combustibles below cooktop chassis
ISO view with raised vent
A 6" Min.
(152 mm)
Top view with raised vent
Countertop Cutout Dimensions With Raised Vent Installed
Model/Configuration
ETT304-1 or MET304 cooktop with ERV30 or PRV30 raised vent.
ETT304-1 or MET304 cooktop with
RV30 raised vent.
Dimension Table - Installations with Raised Vent
A - Cooktop
Cutout Width
B - Raised
Vent Cutout
Width
C - Total
Cutout Depth
28 3/4”
(730 mm)
27 3/4”
(705 mm)
22 1/2”
(572 mm)
22 1/4”
(565 mm)
ETT365-2 or METB365-1 cooktop with ERV36 or PRV36 raised vent.
ETT365-2 or METB365-1 cooktop with RV36 raised vent.
34 3/4”
(883 mm)
33 3/4”
(857 mm)
22 1/2”
(572 mm)
22 1/4”
(565 mm)
D - Raised
Vent
Cutout Depth
2 3/4”
(70 mm)
2 1/2”
(64 mm)
2 3/4”
(70 mm)
2 1/2”
(64 mm)
E - Min. Rear
Countertop
Overhang
3/8”
(10 mm)
5/8”
(16 mm)
3/8”
(10 mm)
5/8”
(16 mm)
5
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 3 Before You Begin
- 3 Important Safety Instructions
- 3 Important Information About Safety Instructions
- 3 Safety Symbols and Labels
- 4 General Safety Precautions
- 5 Installation Specifications
- 5 Product Dimensions
- 5 Electrical Specifications
- 6 Planning the Location
- 6 Cabinet Layout
- 8 Installation Instructions
- 8 Chassis Installation
- 8 Verify the Package Contents
- 8 Electrical Connection
- 10 Verifying Proper Operation