PARTICULAR FEATURES FROM THE DIVA RANGE. Climadiff Multi-Purpose and Aging Wine Cellars, Wine Cabinet
โฆษณา
โฆษณา
PARTICULAR FEATURES FROM THE DIVA RANGE
POSSIBLE ERROR CODES
E01: P1
E02: P2
E03: P3
E09
E010
P1 = temperature sensor located in the bottom part: regulates the refrigeration function and the winter system, if present.
P2 = temperature sensor located in the top part: regulates the superior resistance function; ONLY available in multi-temperature wine cabinets, which are all equipped with this function.
P3 = sensor to measure the humidity levels and to control the humidification system (depending on the model, option unavailable)
E01, E02 and E03: relevant sensor faulty or connection between the circuit board of the power card and the sensor is lost.
E09: the safety thermostat has disconnected the refrigeration and heating functions as the internal temperature is too low.
When the temperature at the bottom of the wine cabinet returns to 6°C or to the selected temperature level, the compressor will restart.
Code E09 flashes with a triangle alert on the screen as long as the power supply and the plug are disconnected from the mains supply for two to three minutes.
The symbol and the error code disappear as soon as the plug is reconnected to the mains supply.
If the temperature is still too cold in the lower section of the cabinet, the "triangle" symbol and the error code reappear.
E10: communication cable for the circuit board and power card or the circuit board for the display is faulty, or the cable is damaged.
Sensors P1, P2, P3 and the safety thermostat are inserted from the rear into foam tubes inside the side walls.
PLEASE NOTE: THE SENSORS MUST BE PUSHED AS FAR AS POSSIBLE UNTIL RESTING AGAINST THE BOTTOM OF
THE TUBE
MT-01 Indice 0 Page 63