Generator Features

OIL ALERT SYSTEM (Model 4W315A only)

The oil alert system protects the engine from low oil damage. This system automatically shuts down the engine and prevents engine restarting if the oil pressure falls too low.

If this system shuts down the engine, the engine will not start until you add oil. The oil alert lamp is near engine starter switch (see Figure 2). Add oil to engine (see

Engine Oil, page 7).

See engine owner’s manual for more information.

120 ONLY

FULL POWER

SELECTOR

120/240V

0

100 200

300

A C VOLTS

OIL

120 ONLY

FULL POWER

SELECTOR

120/240V

0

100 200

300

A C VOLTS

OUTPUT VOLTAGE OUTPUT VOLTAGE

120 VOLT ONLY

POSITION

Figure 3 - Full Power Selector Switch

120/240 VOLT

POSITION

CHARGE

OFF

OIL

ALERT

LAMP

IMPORTANT: DO NOT MOVE THE FULL POWER

SELECTOR SWITCH WHILE POWERING ELECTRI-

CAL ITEMS. UNPLUG ALL ITEMS BEFORE MOVING

SWITCH. FAILURE TO DO SO CAN DAMAGE

SWITCH.

BATTERY

DISCHARGE

LAMP

Figure 2 - Battery Discharge Lamp and Oil Alert

Lamp Location

VOLTMETER

The voltmeter is on the control panel. The voltmeter shows the generator output voltage (see Figure 4).

120 VOLT ONLY full power switch position: The voltmeter will show about 120V under load.

120/240 VOLT full power switch position: The voltmeter will show about 240V under load.

BATTERY DISCHARGE LAMP (Model 4W315A only)

The battery discharge lamp (see Figure 2, above) will light if battery charger is not operating while engine is running. If this happens, the battery will not charge and will eventually run down. Have battery charging circuit repaired by authorized service person.

0

100 200

300

A C VOLTS

FULL POWER SELECTOR SWITCH

The full power selector switch is on the control panel.

The switch has two positions: 120 VOLT ONLY, and

120/240 VOLT.

120 VOLT ONLY: This position sends full power to the

120V receptacles only. 240V power is not available.

Use this position when full power is needed for 120V items only.

120/240 VOLT: This position sends full power to the

120/240V receptacle. It also powers the 120V twist-lock receptacle at half wattage capacity.

6

Figure 4 - Voltmeter

ELECTRIC START (Model 4W315A only)

This model has an electric starter. A battery is not supplied with generator. You must provide a 12-volt, 45amp-hour battery. For more battery information, see

Battery, page 8.