Extra functions - Customer level 2
Hot water settings
Hot water peak
Recurring increase in the hot water temperature
The Range for hot water peak menu is used to set the range for a recurring increase in the hot water temperature. This function takes the water temperature temporarily up to approximately 65°C. Three settings are possible: inactive (default), daily or preferred day.
Timer control
Open the setting menus for timer control like this:
1. Press the Heat button until Access = CUSTOMER2 is displayed.
2. Press the Menu button.
3. Turn the menu dial clockwise until you access the menu Timer control settings (menu 4).
4. Press the Select button and scroll through the menus using the menu dial.
Clock setting of the heat pump according to clock
The function Clock setting HP accord. to clock is for those who want the heat pump to produce different amounts of heat at different times of the day and on different days of the week. This allows you to make further energy savings.
The room sensor T5 (GT5) infl uence is inhibited 24 hours after using clock setting for the heating, or after any type of external control of the heat pump.
This allows the heating to return to ordinary settings. In practise this means that should clock setting of the heating apply each night, then the room sensor has no function except temperature readings.
Example:
You want to set the heat pump so that it maintains a 3ºC lower radiator temperature on Mondays between 22:00 and 06:00.
1. Turn the dial clockwise until you access the menu Clock setting HP accord. to clock (menu 4.1).
2. Press the Select button.
3. Turn the menu dial clockwise to choose the day. Now press the Adjust button to select the weekday with the symbol ^. Turn the menu dial clockwise one step to activate the start day. The weekday now has a capital letter.
4. Press the right-hand arrow (->) until the cursor reaches the fi rst two zeros
(00).
Hot water range for hot water peak 2.2
Return Select
Main menu
Indoor temperature settings 1
Return Select
Main menu
Timer control accord. to clock 4
Return Select
Note
When you have time based tariffs with cheaper electricity for example during the night, any savings may be lost if the return to normal temperature occurs when the more expensive electricity price applies.
Clock setting
Clock setting HP accord. to clock 4.1
Return Select
Timer control HP 1
Mon 00:00-00:00
Return adjust
Timer control HP 1
Mon 00:00-00:00
Return ->
Timer control HP 1
Mon 00:00-00:00
Return ->