CHAPTER 1. SRV. RESET AND MASTER RESET. Sharp UP-700

Add to My manuals
51 Pages

advertisement

CHAPTER 1. SRV. RESET AND MASTER RESET. Sharp UP-700 | Manualzz

CHAPTER 1. SRV. RESET AND MASTER RESET

The SRV key is used for operating in the SRV mode.

1. SRV. reset (Program Loop Reset)

Used to return the machine back to its operational state after a lockup has occurred.

Procedure

Method 1

1) Turn off the AC switch.

2) Set the mode switch to (SRV’) position.

3) Turn on the AC switch.

4) Turn to (SRV) position from (SRV’) position.

Method 2

1) Set the mode switch to PGM2 position.

2) Turn off the AC switch.

3) While holding down JOURNAL FEED key and RECEIPT FEED key, turn on the AC switch.

Note: When disassembling and reassembling always power up using method 1 only. Method 2 will not reset the CKDC10.

Note: SRV programming job#926-B must be set to "4" to allow PGM program loop reset.

PRG. RESET must be entered by hand.

This reset is used if an application needs different keyboard layout other than that supplied by a normal MRS-1.

Procedure

1) Turn off the AC switch.

2) Set the MODE switch to the (SRV’) position.

3) Turn on the AC switch.

4) While holding down JOURNAL FEED key and RECEIPT FEED key, turn to (SRV) position from (SRV’) position.

5) Key position assignment:

After the execution of MRS-2, only the RECEIPT FEED and

JOURNAL FEED keys can remain effective on key assignment.

Any key can be assigned on any key position on the main keyboard.

[key setup procedure]

MRS-2 executed 0 Key position set

*2

Free key

0

Disable

*1

Free key setup complete.

004

005

006

007

Key

No.

001

002

003

008

009

010

MASTER PRESET

NOTES:

*1: When the 0 key is pressed, the key of the key number on display is disabled.

*2: Push the key on the position to be assigned. With this, the key of the key number on display is assigned to that key position.

*3: When relocating the keyboard, the PGM 1/2 mode use standard key layout.

Key name

014

015

016

017

Key

No.

011

012

013

018

019

020

Key name

Key

No.

021

022

023

Key name

2. Master reset (All memory clear)

There are two possible methods to perform a master reset.

MRS-1

Used to clear all memory contents and return machine back to its initial settings.

Return keyboard back to default. for default key-board layout.

Procedure

1) Turn off the AC switch.

2) Set the MODE switch to the (SRV’) position.

3) Turn on the AC switch.

4) While holding down JOURNAL FEED key, turn to (SRV) position from (SRV’) position.

MRS-2

Used to clear all memory and keyboard contents.

This reset returns all programming back to defaults. The keyboard

advertisement

Related manuals