ADJUSTMENT & OPTIONAL SETTINGS

Water Flow Testing and Adjustment

1. Place a graduated measuring cup or the large chamber of the empty brixing cup (BUNN-O-MATIC part number 33095.0000) under the appropriate dispense nozzle. Place the Dispense Lockout switch in the

OFF position.

2. Press and release the desired “Product Dispense Switch” three times.

(On Portion Control models, use the plus/stop switches)

3. The selected position will dispense water (no concentrate) only for 3 seconds.

4. Measure the water dispensed.

5. Adjust the water flow rate Fig 16, (clockwise to increase flow rate; counterclockwise to decrease flow rate) to the corresponding product mix ratio as follows:

P3586

FIG 16 Adjusting Water Flow

Using 1/4" allen wrench

Mix Ratio

(water + concentrate)

2+1

4+1

5+1

3+1 through 7+1

Above 7+1

Adjust water flow rate to:

*3.75 fl. oz (111 ml) per 3-second test

*4.0 fl. oz (118 ml) per 3-second test

*4.0 fl. oz (118 ml) per 3-second test

High Viscosity Juice 2.25 - 3.0 fl. oz (66.5 - 89 ml)

Product

Prune Juice

Other

Orange Juice

Pineapple Juice

Cranberry Fruit Cocktail

Grapefruit Juice

Lemonade

Apple Juice

Fruit Punch

Grape Juice

Other

Other

Brix %

16.0%

*

11.8%

12.8%

14.0%

10.6%

*

*

12.0%

13.0%

As Required

per 3-second test

*Maximum flow rate may be less depending on the water pressure supply at each location.

-

Note: Information for specific products listed in this table is to be used for reference only. Consult the product label for exact mix ratio and/or brix %. See product label for target brix %.

6. Repeat steps 1 through 5 as necessary until the correct water flow rate is achieved.

7. Repeat steps 1 through 5 for the remaining dispense positions.

8. Place the Dispense Lockout switch back into the ON position.

Pump Speed Adjustment

1. Disconnect the dispenser from the power source.

2. Remove the drip tray.

3. Remove the two screws securing the splash panel and remove the splash panel

4. Locate the adjustment knobs on the circuit board.

5. Turn the adjustment knobs clockwise to increase speed and counterclockwise to decrease speed.

6. The knob positions directly correspond to dispense station locations.

NOTE: Some 2S models have 4 adjustment knobs on the circuit board. For these models use the two left most knobs to make pump speed adjustments. Left most being station #1 (left side dispense) and left center being station #2 (right side dispense).

7. Reinstall the splash panel and drip tray and reconnect the dispenser to the power source.

14 39992 023009

ADJUSTMENT & OPTIONAL SETTINGS (cont)

Total Dispense Ratio Set Up Procedure

1. Adjust water flow as described in Water Flow Testing and Adjustment. Record water output setting for later reference on each dispense head.

2. Place the Dispense Lockout switch in the OFF position.

3. Place a measuring container under the dispense nozzle, press and release the DISPENSE button 6 times.

4. Record the total ounces dispensed.

5. Refer to the Brix/Ratio chart below to confirm proper total dispensed amount for ratio desired and water output previously recorded.

6. To increase or decrease the product output, refer to Pump Speed Adjustment section.

7. Place the Dispense Lockout switch back into the ON position.

3 second water dispense

(oz)

1.5

1.75

2.0

2.25

2.5

2.75

3.0

3.25

3.5

3.75

4.0

4.25

4.5

4.75

5.0

Ratio Target

2:1 3:1 4:1 5:1 6:1 7:1 8:1 9:1 10:1 11:1 12:1 13:1 14:1 15:1

2.25 2.00 1.88 1.80 1.75 1.71 1.69 1.67 1.65 1.64 1.63 1.62 1.61 1.60

2.63 2.33 2.19 2.10 2.04 2.00 1.97 1.94 1.93 1.91 1.89 1.88 1.88 1.87

3.00 2.67 2.50 2.40 2.33 2.29 2.25 2.22 2.20 2.18 2.17 2.15 2.14 2.13

3.38 3.00 2.81 2.70 2.63 2.57 2.53 2.50 2.48 2.45 2.44 2.42 2.41 2.40

3.75 3.33 3.13 3.00 2.92 2.86 2.81 2.78 2.75 2.73 2.71 2.69 2.68 2.67

4.13 3.67 3.44 3.30 3.21 3.14 3.09 3.06 3.03 3.00 2.98 2.96 2.95 2.93

4.50 4.00 3.75 3.60 3.50 3.43 3.38 3.33 3.30 3.27 3.25 3.23 3.21 3.20

4.88 4.33 4.06 3.90 3.79 3.71 3.66 3.61 3.58 3.55 3.52 3.50 3.48 3.47

5.25 4.67 4.38 4.20 4.08 4.00 3.94 3.89 3.85 3.82 3.79 3.77 3.75 3.73

5.63 5.00 4.69 4.50 4.38 4.29 4.22 4.17 4.13 4.09 4.06 4.04 4.02 4.00

6.00 5.33 5.00 4.80 4.67 4.57 4.50 4.44 4.40 4.36 4.33 4.31 4.29 4.27

6.38 5.67 5.31 5.10 4.96 4.86 4.78 4.72 4.68 4.64 4.60 4.58 4.55 4.53

6.75 6.00 5.63 5.40 5.25 5.14 5.06 5.00 4.95 4.91 4.88 4.85 4.82 4.80

7.13 6.33 5.94 5.70 5.54 5.43 5.34 5.28 5.23 5.18 5.15 5.12 5.09 5.07

7.5 6.67 6.25 6.00 5.83 5.71 5.63 5.56 5.50 5.45 5.42 5.38 5.36 5.33

Dispensed product (oz)

Temperature Compensated Refractometer Method

1. Adjust the water flow as described in Water Flow Testing and Adjustment.

2. Place an empty container under the appropriate dispense nozzle.

3. Press and hold the “Product Dispense Switch” Figs 9 & 10, until water and concentrate begin flowing freely from the dispense nozzle.

4. Discard the product caught previously and place the empty container back under the dispense nozzle.

5. Press and hold the “Product Dispense Switch” until the cup is filled.

6. Stir the contents of the cup, and use the refractometer (according to the manufacturer’s instructions) to check the brix %.

7. Adjust the pump speed (down to decrease the brix %; up to increase the brix %) to achieve the correct brix

% as described in Pump Speed Adjustment.

15 39992 042007

ADJUSTMENT & OPTIONAL SETTINGS (cont)

Dispenser Lockout

Dispense functions of the dispenser can be turned-off to prevent unauthorized use of the dispenser, while keeping the refrigeration system running.

1. Locate the Dispense Lockout switch at the bottom front of the dispenser behind the drip tray.

2. Place the switch in the OFF position to prevent dispensing.

3. Place the switch in the ON position to allow dispensing.