Completing the Installation
Completing the Installation
Before you begin
Complete all the installation procedures for the internal options you have chosen to install.
Read “Electrical Safety” on page 41.
If you have a tower model, continue with “Completing the Tower Model
Installation.”
If you have a rack model, go to “Completing the Rack Model Installation” on page 79.
Completing the Tower Model Installation
1. Install the cover on the server.
a. Align the left-side cover with the left side of the server, about 25 mm (1 inch) from the front of the server; place the bottom of the left-side cover on the bottom rail of the left-side frame.
b. Insert the tabs at the top of the cover into the slots at the top of the server side.
c. Hold the cover against the server and slide the cover toward the front of the server until the cover clicks into place.
Note: Be sure the front edge of the cover is flat against the server.
76
Netfinity 5000 Server Hardware Information and Procedures
Completing the Installation
2. Replace the bezel, if it was removed.
a. Place the bezel tabs .1/ in the slots at the bottom front of the server.
b. Press the top of the bezel toward the server front until the bezel clicks into place.
3. Replace the server door, if it was removed.
a. Set the door on the bottom hinge.
b. Press the flange downward while pressing the top of the door toward the server, until the flange connects with the top hinge. Release the flange.
4. Close and lock the server door.
Chapter 4. Installing Options
77
Completing the Installation
Attention:
Be sure to maintain a clearance of at least 127 mm (5 inches) on the front and rear of the server to allow for air circulation.
5. Reconnect the cables to the back of the server; then, plug the power cords into properly grounded electrical outlets.
6. If you have a modem or fax machine attached to the server, reconnect the telephone line to the wall outlet and the server.
What to do next
When you have completed installing the covers and cables, go to “Updating the
Server Configuration” on page 82.
78
Netfinity 5000 Server Hardware Information and Procedures
Completing the Installation
Completing the Rack Model Installation
1. Replace the top cover: a. Align the top cover with the top of the server, about 25 mm (1 inch) from the front of the server.
b. Hold the cover against the server and slide the cover toward the front of the server until the cover clicks into place.
Note: Be sure the front edge of the cover is flat against the server.
c. Turn the captive thumbscrew .1/ until the cover is secured.
2. Replace the bezel, if it was removed.
a. Place the bezel tabs .2/ in the slots at the left front of the server.
b. Press the right end of the bezel toward the server front until the bezel clicks into place.
Chapter 4. Installing Options
79
Completing the Installation
3. Attach the monitor, keyboard, and power cables to the corresponding connectors on the server. Refer to the rack documentation for instructions.
80
Netfinity 5000 Server Hardware Information and Procedures
Completing the Installation
4. If you have a modem or fax machine attached to the server, reconnect the telephone line to the wall outlet and the server.
5 k
32 kg (70.5 lbs) k
55 kg (121.2 lbs)
CAUTION:
Use safe lifting practices when lifting your machine.
5. If you are installing the rack model in the rack for the first time, go to “Installing the Server in the Rack Enclosure” on page 102, and then go to “Updating the
Server Configuration” on page 82. Otherwise, continue with the following instructions to secure the rack model in the rack.
a. Slide the rack model into the rack.
b. Locate the screws that you removed in step 3 on page 46.
c. Insert the screws through the bracket, mounting rail, and cage nut.
What to do next
When you have completed installing the cover and cables, go to “Updating the
Server Configuration” on page 82.
Chapter 4. Installing Options
81