- Industrial & lab equipment
- Electrical equipment & supplies
- Batteries & accessories
- Battery chargers
- Studer Innotec
- XTH 5000-24
- Installation and operating instructions
CONTROL AND DISPLAY PARTS FOR THE XTENDER (FIG. 4B). Studer Innotec XTH 6000-48, XTH 5000-24, XTH 8000-48
Add to My manuals36 Pages
advertisement
![CONTROL AND DISPLAY PARTS FOR THE XTENDER (FIG. 4B). Studer Innotec XTH 6000-48, XTH 5000-24, XTH 8000-48 | Manualzz CONTROL AND DISPLAY PARTS FOR THE XTENDER (FIG. 4B). Studer Innotec XTH 6000-48, XTH 5000-24, XTH 8000-48 | Manualzz](http://s1.manualzz.com/store/data/003518102_1-403b97cd5bef6cd79cac60fbfc9baf6e-360x466.png)
STUDER Innotec Xtender
Pos.
Denomination Description Comment
10 L1/L2/L3 Phase selection jumpers. See chapter 6.3.1. – p.22.
Jumper default at position L1
Carefully read chapter 4.5 – p.12 11 +BAT Positive pole battery connection terminals
12 and when tightening the clamp. connection terminals
Take care with the polarity of the battery
Connection terminals for the See chapter 4.5.7 - p. 14.
(generator or public network) be connected.
14 AC Connection terminals for the See chapter 4.5.6 - p. 14. device output. Note: Increased voltages may appear on the terminals, even in the absence of voltage at the input of the inverter.
15
Control and display parts for the Xtender (fig. 4b)
See chapter 7.2 - p. 24.
Pos.
Denomin ation
Description Comments
41 ON/OFF ON/OFF button The ON/OFF button allows the start up or complete stoppage of the system such as it has been programmed. When there are several units in the same system, each unit must be started up or stopped individually using this button.
42 OFF Light indicator for stoppage of the unit stoppage of the unit, its imminent stoppage or the limitation of its rated power output according to chapter 7.2 - p.24.
43 ON Light indicator showing that the equipment is in working. It flashes when the equipment is at a temporary stop. Note: The equipment will restart automatically when the operation conditions that led to the temporary stoppage have gone away. showing that the battery is being charged operation and has not yet reached the absorption phase.
It flashes twice during the absorption phase and once during the maintenance phase.
If smart boost mode has been activated it is possible that this indicator will go out temporarily when source backup is required by users. (See chapter 6.2.6 - p. 19) synchronised input voltage chapter 6.2.5 – p. 19). presence of a when the device is in “load search” mode due to the absence voltage at the of users. (See chapter 6.2.3 – p. 16) output
16
Type plate elements (fig. 1b)
Pos.
Denomination Description
31 Model
32 Pnom/P30
Model
Rated power output / power for 30 minutes
Installation and operating Instructions Xtender V1.3
Comments
Page 32
STUDER Innotec
Pos.
Denomination Description
33 U Battery Rated battery voltage (input area)
34 U ACin Rated AC input voltage (input area)
35 I ACin/out
36 U ACout
37 I Charge
Maximum current at input / output
Rated output voltage
Maximum charger current
39 IPxx Protection degree according to IEC 60529
Xtender
Comments
See chapter 6.2.8– p.
20
See chapter 6.2.3 – p.
17
See chapter 6.2.6 - p.
19.
Or according to {1286}
See chapter 6.2.4 - p.
17
Installation and operating Instructions Xtender V1.3 Page 33
advertisement
Related manuals
advertisement
Table of contents
- 3 INTRODUCTION
- 3 GENERAL INFORMATION
- 6 ASSEMBLY AND INSTALLATION
- 9 CABLING
- 15 POWERING UP THE INSTALLATION
- 16 DESCRIPTION AND FUNCTIONING
- 24 CONTROL
- 26 MAINTENANCE OF THE INSTALLATION
- 26 PRODUCT RECYCLING
- 26 EC DECLARATION OF CONFORMITY
- 27 COMMENTS OF ANNEXES’ FIGURES
- 29 FIGURE ELEMENT'S (DC PART)
- 30 FIGURE ELEMENT'S (AC PART)
- 31 ELEMENTS OF CONNEXION CABINET (FIG 4A)
- 32 CONTROL AND DISPLAY PARTS FOR THE XTENDER (FIG. 4B)
- 32 TYPE PLATE ELEMENTS (FIG. 1B)
- 34 TABLE OF STANDARD CONFIGURATIONS
- 36 TECHNICAL DATA