Maintenance

5.8

Auto Idle Speed

G/GS 5.6A

See Graphic: wc_gr000548

5.8.1

Adjust pilot screw on carburetor as described above.

5.8.2

Loosen clamping screw (b) on auto idle magnet bracket.

5.8.3

Start engine and set auto idle switch to "Auto".

5.8.4

Turn magnet pin (a) in or out to adjust idle speed to 2200 ± 50 rpm.

Note: To avoid excessive vibration and to maintain adequate cooling ability, do not set engine auto idle speed lower than 2200 rpm.

5.8.5

Re-tighten clamping screw.