44
6. INPUT RANGE TABLES
Input Range Table 1
Input type
Thermocouple
K
J
Input range
0 to 200 ° C
0 to 400 ° C
0 to 600 ° C
0 to 800 ° C
0 to 1000 ° C
0 to 1200 ° C
0 to 1372 ° C
-199.9 to 300.0 ° C
0.0 to 400.0 ° C
0.0 to 800.0 ° C
0 to 100 ° C
0 to 300 ° C
0 to 450 ° C
0 to 500 ° C
0.0 to 200.0 ° C
0.0 to 600.0 ° C
-199.9 to 800.0 ° C
0 to 800 ° F
0 to 1600 ° F
0 to 2502 ° F
0.0 to 800.0 ° F
20 to 70 ° F
-199.9 to 999.9 ° F
0 to 200 ° C
0 to 400 ° C
0 to 600 ° C
0 to 800 ° C
0 to 1000 ° C
0 to 1200 ° C
-199.9 to 300.0 ° C
0.0 to 400.0 ° C
0.0 to 800.0 ° C
0 to 450 ° C
0.0 to 200.0 ° C
0.0 to 600.0 ° C
-199.9 to 600.0 ° C
Code
Input Range
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
K
J
J
J
J
J
J
J
J
J
J
J
J
J
14
17
20
29
37
07
08
09
10
13
04
05
06
01
02
03
38
A1
A2
A3
A4
A9
B2
07
08
09
10
22
23
30
04
05
06
01
02
03
Continued on the next page.
IMR01D02-E3
6. INPUT RANGE TABLES
Continued from the previous page.
Input type Input range Code
Input Range
Thermocouple
J
R
S
B
E
0 to 800 ° F
0 to 1600 ° F
0 to 2192 ° F
0 to 400 ° F
0 to 300 ° F
-199.9 to 999.9 ° F
0.0 to 800.0 ° F
0 to 1600 ° C 1
0 to 1769 ° C 1
0 to 1350 ° C 1
0 to 3200 ° F 1
0 to 3216 ° F 1
0 to 1600 ° C 1
0 to 1769 ° C 1
0 to 3200 ° F 1
0 to 3216 ° F 1
400 to 1800 ° C
0 to 1820 ° C 1
800 to 3200 ° F
0 to 3308 ° F 1
0 to 800 ° C
0 to 1000 ° C
0 to 1600 ° F
0 to 1832 ° F
J
J
J
J
J
J
J
R
R
R
R
R
S
S
S
S
B
B
B
B
E
E
E
E
A1
A2
A3
A6
A7
A9
B6
01
02
04
A1
A2
01
02
A1
A2
01
02
A1
A2
01
02
A1
A2
1
2
N
T
0 to 1200 ° C
0 to 1300 ° C
0.0 to 800.0 ° C
0 to 2300 ° F
0 to 2372 ° F
0.0 to 999.9 ° F
-199.9 to +400.0 ° C 2
-199.9 to +100.0 ° C 2
-100.0 to +200.0 ° C
0.0 to 350.0 ° C
-199.9 to +752.0 ° F 2
-100.0 to +200.0 ° F
-100.0 to +400.0 ° F
0.0 to 450.0 ° F
0.0 to 752.0 ° F
N
N
N
N
N
N
T
T
T
T
T
T
T
T
T
01
02
06
A1
A2
A5
01
02
03
04
A1
A2
A3
A4
A5
Accuracy is not guaranteed between 0 to 399 ° C (0 to 751 ° F)
Accuracy is not guaranteed between -199.9 to -100.0 ° C (-199.9 to -148.0 F)
Continued on the next page.
IMR01D02-E3 45
6. INPUT RANGE TABLES
46
Continued from the previous page.
Input type Input range
Thermocouple
RTD
W5Re/W26Re
PL II
U
L
Pt100
0 to 2000 ° C
0 to 2320 ° C
0 to 4000 ° F
0 to 1300 ° C
0 to 1390 ° C
0 to 1200 ° C
0 to 2400 ° F
0 to 2534 ° F
-199.9 to +600.0 ° C *
-199.9 to +100.0 ° C *
0.0 to 400.0 ° C
-199.9 to +999.9 ° F *
-100.0 to +200.0 ° F
0.0 to 999.9 ° F
0 to 400 ° C
0 to 800 ° C
0 to 800 ° F
0 to 1600 ° F
-199.9 to +649.0 ° C
-199.9 to +200.0 ° C
-100.0 to +50.0 ° C
-100.0 to +100.0 ° C
-100.0 to +200.0 ° C
0.0 to 50.0 ° C
0.0 to 100.0 ° C
0.0 to 200.0 ° C
0.0 to 300.0 ° C
0.0 to 500.0 ° C
-199.9 to +999.9 ° F
-199.9 to +400.0 ° F
-199.9 to +200.0 ° F
-100.0 to +100.0 ° F
-100.0 to +300.0 ° F
0.0 to 100.0 ° F
0.0 to 200.0 ° F
0.0 to 400.0 ° F
0.0 to 500.0 ° F
* Accuracy is not guaranteed between -199.9 to -100.0 ° C (-199.9 to -148.0 ° F)
Continued on the next page.
Code
Input Range
U
U
U
U
U
U
L
L
L
L
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
A
A
A
A
A
W
W
W
A1
A2
A3
01
02
03
01
02
A1
A2
A5
A6
A7
A8
A9
10
A1
A2
A3
A4
05
06
07
08
09
01
02
03
04
01
02
A1
01
02
03
A1
A2
IMR01D02-E3
6. INPUT RANGE TABLES
Continued from the previous page.
RTD
Input type
JPt100
Input range
-199.9 to +649.0 ° C
-199.9 to +200.0 ° C
-100.0 to +50.0 ° C
-100.0 to +100.0 ° C
-100.0 to +200.0 ° C
0.0 to 50.0 ° C
0.0 to 100.0 ° C
0.0 to 200.0 ° C
0.0 to 300.0 ° C
0.0 to 500.0 ° C
Code
Input Range
P
P
P
P
P
P
P
P
P
P
Input Range Table 2
Voltage
(V)
Current
(mA)
Input type
0 to 5 V DC
0 to 10 V DC
1 to 5 V DC
0 to 20 mA DC
4 to 20 mA DC
Input range
0. 0 to 100.0 %
4
5
6
7
8
Code
Input Range
01
01
01
01
01
For the current input specification, a resistor of 250 Ω must be connected between the input terminals.
04
05
06
01
02
03
07
08
09
10
IMR01D02-E3 47
advertisement
Related manuals
advertisement
Table of contents
- 7 1. SPECIFICATIONS
- 9 2. WIRING
- 11 3. SETTING
- 11 3.1 Communication Setting Mode
- 12 3.2 Setting the Communication Parameters
- 13 3.3 Device Address/Slave Address Setting
- 15 3.4 Communication Speed Setting
- 17 3.5 Data Configuration Setting
- 19 3.6 Interval Time Setting
- 20 3.7 Communication Requirements
- 23 4. RKC COMMUNICATION PROTOCOL
- 23 4.1 Polling
- 24 4.1.1 Polling procedures
- 27 4.1.2 Polling procedure example
- 28 4.2 Selecting
- 28 4.2.1 Selecting procedures
- 31 4.2.2 Selecting procedure example
- 32 4.3 Communication Identifier List
- 36 5. MODBUS COMMUNICATION PROTOCOL
- 36 5.1 Message Format
- 37 5.2 Function Code
- 37 5.3 Communication Mode
- 38 5.4 Slave Response
- 39 5.5 Calculating CRC
- 41 5.6 Message Format
- 41 5.6.1 Reading holding registers [03H]
- 42 5.6.2 Preset single resister [06H]
- 43 5.6.3 Diagnostics (loopback test) [08H]
- 44 5.7 Data Configuration
- 44 5.7.1 Data range
- 45 5.7.2 Data processing precautions
- 46 5.8 Communication Data List
- 50 6. INPUT RANGE TABLES
- 54 7. TROUBLESHOOTING
- 57 8. ASCII 7-BIT CODE TABLE