PARTS REPLACEMENT

5.

Power Supply Unit

(1) Remove

Upper case unit according to the procedure described in item 1.

Connector [1]

Three tapping screws [2]

Two screws [3]

Two screws [4]

Power switch holder [5]

Power switch [6]

Power supply unit [7]

6.

Fuses

(1) Remove

Power supply unit according to the procedure described in item 5.

(2) Inspect

Fuse F1 [1]

Fuse F2 [2]

Fuse F3 [3]

Defective → Replace fuse as follows:

AC Voltage

120V

220V/240V

F1

5TT1A

630mA

Destination F2,F3

For US, UK, AS 5TT3A

For EC, WG, HK EAK3.15A

New fuse blown → Inspect circuit