Frame and Module Parameters. Imagine communications Magellan SDNO Controller
Reklamë
Reklamë
Magellan™ SDN Orchestrator
Installation, Configuration, and Operation Manual Frame and Module Parameters
Frame and Module Parameters
Through the web based UI, once you've set up your frames and modules, you can configure and control parameters for those modules.
For a complete list of modules and parameters, refer to the
IP3 Frame and Modules User Manual
.
Frames and Modules in the Web Interface
After a frame has been added to your system, you can see status and set editable parameters for both the frame and the modules in the frame. Click the
Go to Frame
button against the Frame for details (See
Frame Components (on page 122)).
A list of available modules and parameters are displayed, categorized by type.
Click the
Open Module
button to the right to see details of a module.
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
Version 2.0 | Page 118
Magellan™ SDN Orchestrator
Installation, Configuration, and Operation Manual Frame and Module Parameters
The module is then displayed along with all of its parameters. Some of the parameters are status only
(read-only) and some are editable.
Note:
The window that is displayed (superimposed) contains details for the module clicked on - however, if there are more than one of that type of module in the frame, all modules of that type will be displayed in the column on the left.
Parameter/Status Menu Groups
For each Input/Output module, parameters/statuses are organized into three groups:
Module
Parameters that affect the module as a whole (such as Sync Select), or status that reflects the module as a whole (such as Software Version), are usually organized under this category.
Inputs/Outputs
Parameters and status that are indexed for each Input/Output on the module are organized under
Inputs
(for Input modules) or
Outputs
for Output modules (See Table Parameters (on page 121)).
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
Version 2.0 | Page 119
Magellan™ SDN Orchestrator
Installation, Configuration, and Operation Manual
Parameter Types
Frame and Module Parameters
Read-Only (Status) Parameters
Read-only or status parameters feed back the current state of a specific parameter.
Figure 39: Example of a Read-Only parameter
String Parameters
String parameters are items that can be renamed using text characters. String parameter changes do not take effect until the entire string has been modified. Use a keyboard, or copy and paste, to enter a value.
List Parameters
List parameters contain a series of possible values for a specific parameter. Enumeration and string-list parameter changes are always delayed. List parameters are identifiable by the arrow in the right corner of the button. When you roll the mouse over a list parameter, the button highlights, and when you click the arrow, available options are displayed. Select an item in the list to set the value for this parameter.
Figure 40: Example of a List Parameter
Range Parameters
A range parameter uses an incremented slider to choose a value from all available values. Numeric parameter values are represented by a sliding bar on the display screen. A progress bar indicates where the current value is within the entire range the parameter presents. The current value is shown at the right of the progress bar.
Figure 41: Example of a Range Parameter
You can control the editable parameters by entering values, selecting options from drop down lists, or in some cases by dragging a slider to the appropriate value.
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
Version 2.0 | Page 120
Magellan™ SDN Orchestrator
Installation, Configuration, and Operation Manual
Table Parameters
Frame and Module Parameters
Table parameters provide an interface to view a large number of settings in a single screen, linking multiple instances of the same parameter or series of parameters (for example, parameters that apply to multiple channels) OR simply grouping similar parameters together.
This screenshot shows parameters for the PT-FSDX8C1D-IBG Input Module, which has some General Info parameters
grouped
under a table. Click
Show Table
to view/expand options.
This screenshot displays how parameters that apply to multiple channels are combined and displayed.
The screen is divided into three panes - with the module on the left, instances in the middle, and the parameter fields to the right. You can drag the divider between these panes to expand and contract the view. You will see multiple rows corresponding to multiple channels.
Menu options can be accessed from menu links on the left and menu options in the drop down list in the top right hand corner.
To change a table parameter:
1.
Select a row (input) from the middle section (in this case, a channel). The Parameter pane updates to display the options and current settings for that row. By default, the parameter pane displays parameters for the first row in the table. The top right corner of the screen updates to indicate the row the parameters are for.
2.
Select the parameter you want to change.
The individual parameter control types are the same as for regular parameters.
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
Version 2.0 | Page 121
Magellan™ SDN Orchestrator
Installation, Configuration, and Operation Manual
Frame Components
Frame and Module Parameters
When you click the
Go to Frame
option for a specific frame on the main navigation page, it displays a complete snapshot of that frame including:
Modules in a Frame (on page 50 )
Frame Parameters (on page 122)
Power Supply and Chassis Fan Status
Frame Parameters
Frame specific components and their parameters can be viewed by clicking the
Open Frame
link.
Figure 42: Open Frame option to access Frame parameters
The following parameters provide a control interface to the IP3 frame. These parameters are divided into different menu groups, all listed below the main Frame:
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
Version 2.0 | Page 122
Magellan™ SDN Orchestrator
Installation, Configuration, and Operation Manual Frame and Module Parameters
Frame Parameters (on page 122 )
Video Crosspoint (on page 125)
Frame
The
Frame
section provides the following parameters:
Table 8: Frame parameters
Parameter
Frame Type
Frame ID
Ambient Temperature
Type Description/Options
RO
RO
RO
IP3 28 RU
IP3 15 RU
A unique 6-byte frame identifier
The Frame temperature in degrees celsius
Figure 43: Frame Parameters
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
Version 2.0 | Page 123
Magellan™ SDN Orchestrator
Installation, Configuration, and Operation Manual
PX-RES
The
PX-RES
section provides the following parameters:
Frame and Module Parameters
Table 9: PX-RES parameters
Parameter
PX-RES 1 Serial #
PX-RES 2 Serial #
PX-RES 1
PX-RES 2
Select Active PX-RES
PX-RES Firmware Version
Type Description/Options
RO
RO
RO
RO
RW
<String>
Not Present
<String>
Not Present
Active
Standby
Not Present
Initializing
Configuring
Failsafe
Active
Standby
Not Present
Initializing
Configuring
Failsafe
PX-RES1
PX-RES2
RO A string showing the current firmware version of the active
PX-RES
PX-RES Alternate Version RO A string showing the firmware version on the alternate bank of the active PX-RES
Figure 44: PX-RES Parameters
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
Version 2.0 | Page 124
Magellan™ SDN Orchestrator
Installation, Configuration, and Operation Manual
Video Crosspoint
The
Video Crosspoint
section provides the following parameters:
Table 10: Video Crosspoint parameters
Parameter
Video Crosspoint 1
Video Crosspoint 2
Select Active Video Crosspoint
Type Description/Options
RO
RO
RW
Active
Standby
Not Present
Failed
Active
Standby
Not Present
Failed
Module1
Module2
Frame and Module Parameters
Figure 45: Video Crosspoint Parameters
TDM Crosspoint
The
TDM Crosspoint
section provides the following parameters:
Table 11: TDM Crosspoint parameters
Parameter
TDM Crosspoint 1
Type Description/Options
RO
Active
Standby
Not Present
Failed
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
Version 2.0 | Page 125
Magellan™ SDN Orchestrator
Installation, Configuration, and Operation Manual
Parameter
TDM Crosspoint 2
Select Active TDM Crosspoint
Type Description/Options
RO
RW
Active
Standby
Not Present
Failed
Module1
Module2
Frame and Module Parameters
Figure 46: TDM Crosspoint Parameters
Sync
The
Sync
section provides the following parameters:
Table 12: Sync Parameters
Parameter
Sync Mode
(Table Parameter)
Type Description/Options
RW Auto, Standard, Advanced
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
Version 2.0 | Page 126
Magellan™ SDN Orchestrator
Installation, Configuration, and Operation Manual
Parameter
Output Standard
(RW only when Sync Mode (Table
Parameter) is set to Standard)
(Table Parameter)
Sync Pulse Delay
(available only when Sync Mode
(Table Parameter) is set to
Advanced)
(Table Parameter)
Type Description/Options
RW
None
525/60
525/59.94
625/50
1920x1080/60I
1920x1080/59.94I
1920x1080/50I
1920x1080/30P
1920x1080/29.97P
1920x1080/25P
1920x1080/24P
1920x1080/24PsF
1920x1080/23.97P
1920x1080/23.97PsF
1280x720/60P
1280x720/59.94P
1280x720/50P
1920x1080/60P
1920x1080/59.94P
1920x1080/50P
RW 0 to 65535
RO
Frame and Module Parameters
Displays the current detected reference standard. Detected Sync
(Table Parameter)
Sync Module 1
Sync Module 2
Select Active Sync Module
Sync 3 - Source Select
Sync 4 - Source Select
RO
RO
RW
RW
RW
Active, Standby, Not Present
Active, Standby, Not Present
Module1
Module2
Sync 1
Sync 2
Sync 3
Sync 1
Sync 2
Sync 4
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
Version 2.0 | Page 127
Magellan™ SDN Orchestrator
Installation, Configuration, and Operation Manual Frame and Module Parameters
Figure 47: Sync Parameters
Sync Notes
The
Sync Mode
parameter (set to
Auto
by default) allows for configuration of switching point settings. In
Auto
mode, the output switches relative to the detected sync reference assigned to the module.
If
Sync Mode
is set to
Standard
, the
Output Standard
parameter can be used to specify the video standard to use as the switching point timing reference relative to the sync reference signal detected on the selected Sync input (Sync 1 - 4)
If
Sync Mode
is set to
Advanced
, the
Sync Pulse Delay
parameter can be used to specify where the output switching point is relative to the reference signal. The delay is in units of microseconds.
Power Supplies
The
Power Supplies
section provides the following parameters:
Table 13: Power Supplies parameters
Parameter
Top Shelf 5V Power
(28 RU only)
5V Power
(15 RU only)
Bottom Shelf 5V Power
(28 RU only)
Zone 1 24V Power
Zone 2 24V Power
Type Description/Options
RO
RO
RO
RO
RO
Present
Failed
Present
Failed
Present
Failed
Present
Failed
Present
Failed
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
Version 2.0 | Page 128
Magellan™ SDN Orchestrator
Installation, Configuration, and Operation Manual
Parameter
Zone 3 24V Power
(28 RU only)
Zone 4 24V Power
(28 RU only)
Type Description/Options
RO
Present
Failed
RO
Present
Failed
Frame and Module Parameters
Figure 48: Power Supplies Parameters for a 28 RU Frame
Ethernet Ports
The
Ethernet Ports
section provides the following parameters:
Table 14: Ethernet Ports Parameters
Parameter
MAC Address 1
Type Description/Options
RO MAC Address of the 1st Ethernet Port on the active PX-RES
Port 1 if PX-RES on the top slot is active
Port 3 if PX-RES on the bottom slot is active
IP Address 1
IP Mask 1
Gateway Address 1
Save Ethernet 1
RW
RW
RW
RW
IP address string for the back panel Ethernet connectors 1 and 3
IP mask string for the back panel Ethernet connectors 1 and 3
Gateway Address string
No
Yes
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
Version 2.0 | Page 129
Magellan™ SDN Orchestrator
Installation, Configuration, and Operation Manual
Parameter
MAC Address 2
Frame and Module Parameters
Type Description/Options
RO MAC Address of the 2nd Ethernet Port on the active PX-
RES
Port 2 if PX-RES on the top slot is active
Port 4 if PX-RES on the bottom slot is active
IP Address 2 RW
IP Mask 2
Gateway Address 2
Save Ethernet 2
RW
RW
RW
IP address string for the back panel Ethernet connectors 2 and 4
IP mask string for the back panel Ethernet connectors 2 and 4
Gateway Address string
No
Yes
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
Version 2.0 | Page 130
Magellan™ SDN Orchestrator
Installation, Configuration, and Operation Manual
Serial Ports
The
Serial Ports
section provides the following parameters:
Table 15: Serial Ports parameters
Parameter
Port (1-2) Mode
Port (1-2) Baud Rate
Port (1-2) Stop Bit
Port (1-2) Parity
Save Serial (1-2)
Type Description/Options
RW
RW
RW
RW
RW
RS 232
RS 422
300
600
1200
2400
4800
9600
14400
19200
38400
57600
115200
1
2
None
Odd
Even
No
Yes
Frame and Module Parameters
Frame Faults
To see Frame specific faults:
1.
On the main navigation page, click the
Go to Frame
button against a Platinum IP3 or Platinum frame
2.
Click the
Open Frame
button under Frame Configuration on the right
3.
In the Frame view that is displayed, click the
Faults
button
For information on the cause of the fault, look at the
Fault Name
column.
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
Version 2.0 | Page 131
Magellan™ SDN Orchestrator
Installation, Configuration, and Operation Manual
Frame Faults - IP3 Frame
Frame and Module Parameters
The following table lists possible Frame faults and descriptions for an IP3 Frame.
Table 16: Frame Faults
Fault Name
Power Supply Failure
Description
One of the Power Supplies has failed
Video Crosspoint 1 Cooling Failure Video Crosspoint 1 has reached a critical temperature threshold
Video Crosspoint 2 Cooling Failure Video Crosspoint 2 has reached a critical temperature threshold
Front Fan 1 Failure
Front Fan 2 Failure
At least one of the Fans in Fan Module 1 has failed
At least one of the Fans in Fan Module 2 has failed
Rear Fan Failure
Power Supply Fan Failure
Failsafe Mode
At least one of the Rear Fans has failed
At least one of the Power Supply Fans has failed
The Resource Module (PX-RES) is in failsafe mode
(this is a warning, not an alarm)
Image Activation Failure
Synchronization Failure
The active image has rebooted more than 5 times (this occurs if the software crashes)
Synchronization between the Active and Standby Resource
Module (PX-RES) has failed.
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
Version 2.0 | Page 132
Magellan™ SDN Orchestrator
Installation, Configuration, and Operation Manual
Frame Faults - Platinum Frame with PX-RES
Frame and Module Parameters
The following table lists possible Frame faults and descriptions for a Platinum Frame with PX-RES.
Table 17: Frame Faults
Fault Name
Power Supply Failure
Power Supply Fan Failure
Failsafe Mode
Image Activation Failure
Synchronization Failure
Upper Fan Failure
Control Section Fan Failure
Lower Fan Failure
Module Alarm
Description
One of the Power Supplies has failed
At least one of the Power Supply Fans has failed
PX-RES is in failsafe mode
(this is a warning, not an alarm)
The active image has rebooted more than 5 times (this occurs if the software crashes)
Synchronization between the Active and Standby Resource
Module (PX-RES) has failed.
At least on of the fans in the IO Module section has failed
At least one of two fans in the Resource Module section has failed
At least one of the fans in the lower section of the frame has failed (only applies to a 28 RU Platinum frame)
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
Version 2.0 | Page 133
Shkarko