Filter capacitor (FR-HCC2). Mitsubishi Electric Marine Battery FR-HC2, FR-HC2-7.5K, FR-HC2, FR-HC2-H7.5K
Add to My manuals203 Pages
advertisement
HC2.book 179 ページ 2012年11月19日 月曜日 午前10時52分
FR-HCB2-H160K, H220K
R2/L12 T2/L32
S2/L22
Outline dimensions
MC
TB1-2 TB1-1
ROH1 ROH2 88R 88S
S3/L23
R3/L13
<Terminal screw size>
T3/L33
Model
FR-HCB2-H160K, 220K
Earth
(ground) terminal
MC TB1-1 TB1-2
M12 M3.5
M3.5
Earth
(ground) terminal
M10
6.3.6
Filter capacitor (FR-HCC2)
FR-HCC2-H280K
300
90 5 90 5
2-15 20 oval-shaped hole
365 3
400 3
370 3
394 3
Enlarged drawing of the installation foot
(Recommended bolt size: M12)
370 3
394 3
R7.5
(25)
80 2
Earth (ground) terminal
(M8 bolt)
(Unit: mm)
Mass: 17kg
179
6
HC2.book 180 ページ 2012年11月19日 月曜日 午前10時52分
Outline dimensions
FR-HCC2-H400K
400 3
365 3
2-15 20 oval-shaped hole
M12 screws
52.5
102.5
300
90 5 90 5 M12 bolt
370 3
394 3
Installation foot
Earth (ground)
terminal (M8 bolt) 80 2
Enlarged drawing of the installation foot
(Recommended bolt size: M12)
R7.5
370 3
394 3
(Unit: mm)
Mass: 15kg
FR-HCC2-H560K
500 3
140 5
400
140 5
M12 bolt
Enlarged drawing of the installation foot
(Recommended bolt size: M12)
R7.5
470 2
494 3
2-15 20 oval-shaped hole
Earth (ground)
terminal (M8 bolt)
470 2
494 3
80 2
(Unit: mm)
Mass: 21kg
180
advertisement
Related manuals
advertisement
Table of contents
- 9 1.1 Pre-operation instructions
- 9 Features of FR-HC2 (high power factor converter)
- 9 Japanese harmonic suppression guideline
- 12 Product checking and parts identification
- 14 1.2 Converter and peripheral devices
- 15 1.3 Precautions for selecting peripheral devices
- 15 Measures against noises (EMI)
- 18 Peripheral device list
- 21 Selecting the rated sensitivity current for the earth leakage circuit breaker
- 23 2.1 Removal and installation of the converter (FR-HC2) front cover
- 25 cover
- 26 2.3 Installation
- 26 Converter placement
- 28 2.4 Protruding the heatsink
- 28 When using a heatsink protrusion attachment (FR-A7CN)
- 28 Heatsink protrusion for 160K or higher
- 30 2.5 Installation of peripheral devices
- 30 Installation of reactor 1 and reactor
- 31 Installation of the outside box (FR-HCB2-7.5K to 75K, FR-HCB2-H7.5K to H220K)
- 32 Installation of filter capacitor (FR-HCC2-H280K to H560K)
- 32 Installation of inrush current limit resistor (FR-HCR2-H280K to H560K)
- 33 Installation of MC power supply stepdown transformer (FR-HCM2-H280K to H560K)
- 34 2.6 Main circuit terminal specifications
- 34 Description of main circuit terminal
- 35 Terminal arrangement of the main circuit terminal
- 38 Cable sizes of the main control circuit terminals and earth (ground) terminals
- 41 (FR-HC2-7.5K to 75K, FR-HC2-H7.5K to H220K)
- 41 Connection diagram (when using with the FR-A700 series)
- 42 Wiring of main circuit
- 48 2.8 Wiring of main circuit (FR-HC2-H280K)
- 48 Connection diagram (when using with the FR-A700 series)
- 50 Wiring of main circuit
- 54 2.9 Wiring of main circuit (FR-HC2-H400K, H560K)
- 54 Connection diagram (when using with the FR-A700 series)
- 55 Wiring of main circuit
- 60 2.10 Notes on earthing (grounding)
- 61 2.11 Compatible inverter for the high power factor converter
- 61 2.11.1 Applicable inverter capacity
- 62 2.11.2 Inverter parameter settings
- 63 2.12 Wiring of several inverters to one converter
- 65 2.13 Wiring of control circuit
- 65 2.13.1 Description of control circuit terminal
- 67 2.13.2 Changing the control logic
- 69 2.13.3 Control circuit terminal layout
- 70 2.13.4 Wiring instructions
- 71 2.13.5 When connecting the operation panel or parameter unit using a connection cable
- 71 2.13.6 Communication operation (computer link operation)
- 73 3.1 Operation panel (FR-DU07-CNV)
- 73 Names and functions of the operation panel (FR-DU07-CNV)
- 74 Basic operation (factory setting)
- 75 Changing the parameter setting value
- 76 parameter unit with battery pack (FR-PU07BB(-L))
- 76 Parts identification of the parameter unit
- 76 Explanation of keys
- 77 Monitoring function
- 78 Function menu
- 80 3.3 Parameter list
- 82 3.4 Description of parameters
- 82 Displaying and hiding extended parameters (Pr. 0)
- 82 Input frequency to converter (Pr. 1, Pr. 2)
- 83 Input terminal function selection (Pr. 3 to Pr. 7)
- 84 Operation selection of SOF signal and OH signal (Pr. 8, Pr. 9)
- 85 Output terminal function selection (Pr. 10 to Pr. 16)
- 86 DC voltage control (Pr. 22 to Pr. 24, Pr. 80, Pr. 81)
- 87 Input current detection function (Y12 signal, Y13 signal, Pr. 25 to Pr. 30)
- 88 Displaying the life of the converter parts (Pr. 31 to Pr. 33)
- 89 Maintenance timer alarm (Pr. 34, Pr. 35)
- 90 3.4.10 Cooling fan operation selection (Pr. 36)
- 90 3.4.11 Instantaneous power failure detection hold (Pr. 44)
- 91 Pr. 51, Pr. 53, Pr. 55, Pr. 56)
- 93 3.4.13 DU/PU, terminal FM/AM monitor display selection (Pr. 46 to Pr. 48, Pr. 50, Pr. 52, Pr. 54)
- 96 3.4.14 Operation selection at instantaneous power failure (Pr. 57)
- 97 3.4.15 Free parameter (Pr. 58, Pr. 59)
- 97 3.4.16 Key lock selection of operation panel(Pr. 61)
- 98 3.4.17 Retry function (Pr. 65, Pr. 67 to Pr. 69)
- 99 3.4.18 Reset selection/disconnected PU detection/PU stop selection (Pr. 75)
- 101 3.4.19 Parameter write disable selection (Pr. 77)
- 102 3.4.20 Current control (Pr. 82, Pr. 83)
- 102 3.4.21 Wiring and configuration of PU connector
- 104 3.4.22 Initial settings and specifications of RS-485 communication (Pr. 117 to Pr. 124)
- 105 3.4.23 Mitsubishi inverter protocol (computer link communication)
- 116 3.4.24 Initial setting and specification for the CC-Link communication function (Pr. 542 to Pr. 544)
- 122 3.4.25 Operation at a communication error (Pr. 500 to Pr. 502)
- 123 3.4.26 Communication EEPROM write selection (Pr. 342)
- 124 3.4.27 Setting of the parameter unit and operation panel (Pr. 145, Pr. 990, Pr. 991)
- 125 3.4.28 Terminal FM and AM calibration (calibration parameter C0 (Pr. 900), C1 (Pr. 901))
- 127 3.5 Parameter clear / All parameter clear
- 128 3.6 Parameter copy and parameter verification
- 131 4.1 Troubleshooting
- 131 4.2 Reset method of protective function
- 132 4.3 List of fault and alarm indications
- 133 4.4 Causes and corrective actions
- 140 4.5 Correspondences between digital and actual characters
- 141 4.6 Check and clear of the faults history
- 143 4.7 Check first when you have a trouble
- 145 5.1 Inspection items
- 145 Daily inspection
- 145 Periodic inspection
- 146 Daily and periodic inspection list
- 147 Checking the converter module
- 147 Cleaning
- 148 Replacement of parts
- 152 5.2 Measurement of main circuit voltages, currents and powers
- 153 Insulation resistance test using megger
- 153 Pressure test
- 155 6.1 Rated specifications
- 156 6.2 Common specifications
- 157 6.3 Outline dimensions
- 157 Converter (FR-HC2)
- 164 Reactor 1 (FR-HCL21)
- 172 Reactor 2 (FR-HCL22)
- 179 Difference between the reactor 1 (FR-HCL21) and the reactor 2 (FR-HCL22)
- 179 Outside box (FR-HCB2)
- 186 Filter capacitor (FR-HCC2)
- 188 FR-HCM
- 192 Inrush current limit resistor (FR-HCR2)
- 193 Parameter unit
- 195 Appendix 1 Instruction code list
- 196 Appendix 2 Instructions for compliance with the EU Directives
- 198 Appendix 3 Instructions for UL and cUL