advertisement
DISCOVERY PRODUCT GUIDE
Interfaces
A comprehensive range of interfaces for use with Discovery systems and incorporating the Ampac fire alarm control panels is available. They are designed to enable fire protection systems to be engineered simply and effectively without the need for customdesigned equipment.
These interfaces are available in three types of housing. The standard interfaces are designed to be surface or flush-mounted while the DIN-rail versions feature enclosures that clip to a standard
35mm DIN rails (DIN46277) or are screwed to the base of a larger enclosure. Miniature interfaces use very compact enclosures for installation into other equipment.
The standard interface range is fitted with bi-directional, short-circuit isolators. These interfaces allow for easier installation when large numbers of interfaces are required.
The following interfaces may be incorporated into Discovery systems:
•
Input/Output Unit provides a relay output and one monitored input
•
3-channel Input/Output Unit provides 3 relay outputs and 3 monitored inputs
•
Mains Switching Input/Output Unit switches machinery operating at 230V
•
Output Unit provides one relay output
•
Zone Monitor controls a zone of conventional detectors
•
Switch Monitor monitors the operation of a switch
•
Switch Monitor Plus monitors the operation of a switch; also incorporates a time delay
•
Sounder Controller controls the operation of conventional sounders
•
Mini Switch Monitor monitors the operation of a switch and is small enough to fit into other equipment
For further information on the range of compatible interfaces refer to Ampac Product Guide MAN3040.
13
Isolators
13.1 Product Codes
Product Description
XP95/Discovery Isolating Base with Xpert Card
XP95/Discovery Isolator
XP95/Discovery Isolator Base (for above)
All XP95 isolators and isolating bases are suitable for use with
Discovery detectors and manual call points. These are:
For further information on the use of isolators in Discovery systems refer to Ampac Product Data sheet PDS201-9001.
Product Number
45681-284AMP
55000-720AMP
45681-211AMP
Item Number
201-0125
201-0172
201-0006
24
MAN3038-2
advertisement
Related manuals
advertisement
Table of contents
- 4 Introduction
- 4 Communications
- 5 Discovery Feature-Smoke & Heat Detectors
- 5 Response Setting
- 5 User bytes and other stored data
- 5 Flashing LED
- 6 Remote test feature
- 6 Rejection of transient signals
- 6 Interchangeability
- 7 Discovery Features- Smoke Detectors
- 7 Drift compensation
- 8 Optical Smoke Detector
- 8 Operating Principles
- 9 Technical Data
- 10 Optical/Heat Multisensor Detector
- 10 Operating Principles
- 12 Technical Data
- 13 Ionisation Smoke Detector
- 13 Operating Principles
- 15 Technical Data
- 16 Carbon Monoxide / Heat Multisensor Detector
- 16 Operating Principles
- 17 Technical Data
- 18 Carbon Monoxide Detector
- 18 Operating Principles
- 21 Technical Data
- 22 Heat Detector
- 22 Operating Principles
- 23 Technical Data
- 24 Mounting Bases
- 24 Technical Description
- 25 Manual Call Point
- 25 Operating Principles
- 25 Non Standard Call Points
- 26 Technical Data
- 27 Interfaces
- 27 Isolators
- 28 Sounder Beacon Base
- 30 Open Area Sounder Beacon
- 30 Technical Data
- 31 Maintenance of Detectors