en_Fehlerliste. Krone EzBA TT, Messages - Parameters
Krone EzBA TT
Krone EzBA TT is the new and convenient way to control ISOBUS-compatible machines. With the Krone EzBA TT, you can easily operate all ISOBUS-compatible applications with just one terminal; the intuitive user interface guides the operator through the different functions quickly and easily. The graphic display allows a clear view of all relevant machine settings and information. The high resolution touchscreen ensures easy operation, even while wearing gloves. The Krone EzBA TT is also equipped with a built-in GPS receiver, which allows you to record field boundaries, track your current position, and use GPS-based applications. The terminal can be easily mounted to the tractor’s cab using the included mounting bracket. The Krone EzBA TT supports variable-rate application and has a section control feature.
Reklama
Reklama
Error list
Software version: D2515020141600016_300
Control unit: KMC
Page 1
Error number
KMC-520192-19
Error text
CAN1 - CAN disturbance between control units
KMC-520193-19 CAN2 - CAN disturbance between control units
KMC-520194-19 CAN3 - CAN disturbance between control units
KMC-520195-19 CAN4 - CAN disturbance between control units
KMC-520198-12 Control unit - Internal Error
KMC-520232-12
KMC-520234-31
KMC-521100-3
KMC-521100-4
KMC-521100-5
KMC-521100-6
KMC-521101-3
KMC-521101-4
KMC-521101-5
KMC-521101-6
KMC-521102-3
Vehicle Identification Number -
Internal Error
System check with KMC failed
Voltage group UB1 - Overvoltage
Voltage group UB1 - Undervoltage
Voltage group UB1 - Ground fault
Voltage group UB1 - Overload
Voltage group UB2 - Overvoltage
Voltage group UB2 - Undervoltage
Voltage group UB2 - Ground fault
Voltage group UB2 - Overload
Voltage group UB3 - Overvoltage
Description
There is a CAN disturbance between control units on CAN 1.
Figure
There is a CAN disturbance between control units on CAN 2.
There is a CAN disturbance between control units on CAN 3.
There is a CAN disturbance between control units on CAN 4.
An internal error in the control unit which was actuated by defective software or hardware.
The vehicle identification number has not been initialised.
With the KMC the cross-controller adjustment of system-relevant machine data has failed.
The input voltage of the corresponding voltage group is too high.
The input voltage of the corresponding voltage group is too low.
A ground fault has occurred on the supply voltage.
The maximum load on the supply voltage has been exceeded.
The input voltage of the corresponding voltage group is too high.
The input voltage of the corresponding voltage group is too low.
The maximum load on the supply voltage has been exceeded.
The maximum load on the supply voltage has been exceeded.
The input voltage of the corresponding voltage group is too high.
Page 2
Error number
KMC-521102-4
KMC-521102-5
KMC-521102-6
KMC-521103-3
Error text
Voltage group UB3 - Undervoltage
Voltage group UB3 - Ground fault
Voltage group UB3 - Overload
Voltage group UB4 - Overvoltage
KMC-521103-4 Voltage group UB4 - Undervoltage
KMC-521103-5
KMC-521103-6
KMC-521104-3
KMC-521104-4
KMC-521104-5
KMC-521104-6
KMC-521105-3
KMC-521105-4
KMC-521105-5
KMC-521105-6
KMC-521106-11
Voltage group UB4 - Ground fault
Voltage group UB4 - Overload
Voltage group UB5 - Overvoltage
Voltage group UB5 - Undervoltage
Voltage group UB5 - Ground fault
Voltage group UB5 - Overload
Voltage group UB6 - Overvoltage
Voltage group UB6 - Undervoltage
Voltage group UB6 - Ground fault
Voltage group UB6 - Overload
Supply voltage sensors - General disturbance
Description
The input voltage of the corresponding voltage group is too low.
Figure
A ground fault has occurred on the supply voltage.
The maximum load on the supply voltage has been exceeded.
The input voltage of the corresponding voltage group is too high.
The input voltage of the corresponding voltage group is too low.
A ground fault has occurred on the supply voltage.
The maximum load on the supply voltage has been exceeded.
The input voltage of the corresponding voltage group is too high.
The input voltage of the corresponding voltage group is too low.
A ground fault has occurred on the supply voltage.
The maximum load on the supply voltage has been exceeded.
The input voltage of the corresponding voltage group is too high.
The input voltage of the corresponding voltage group is too low.
A ground fault has occurred on the supply voltage.
The maximum load on the supply voltage has been exceeded.
The voltage has been switched off due to an overload or a short circuit on the supply voltage of the sensors.
Page 3
Error number
KMC-521107-3
KMC-521107-4
KMC-521108-11
KMC-521109-11
KMC-521110-11
KMC-521111-11
KMC-521112-11
Error text
Supply voltage - Overvoltage
Supply voltage - Undervoltage
Control unit - General disturbance
Control unit - General disturbance
Control unit - General disturbance
Control unit - General disturbance
Control unit - General disturbance
Description
The power supply on the UE connection is too high.
The power supply on the UE connection is too low.
The voltage group relay UB1 has not passed the self-test.
Figure
The voltage group relay UB2 has not passed the self-test.
The voltage group relay UB3 has not passed the self-test.
The voltage group relay UB4 has not passed the self-test.
The voltage group relay UB5 has not passed the self-test.
KMC-521113-11 Control unit - General disturbance The voltage group relay UB6 has not passed the self-test.
KMC-521114-11
KMC-521115-11
KMC-521116-11
KMC-521117-11
KMC-521118-11
KMC-521320-2
Sensor supply voltage U1 - General disturbance
Sensor supply voltage U2 - General disturbance
Sensor supply voltage U3 - General disturbance
Sensor supply voltage U4 - General disturbance
Voltage group relay UB2 - General disturbance
Machine configuration - Logic error electronics
The voltage group Uext1 for supplying the sensors is defective, for example due to overload or short circuit.
The voltage group Uext2 for supplying the sensors is defective, for example due to overload or short circuit.
The voltage group Uext3 for supplying the sensors is defective, for example due to overload or short circuit.
The voltage group Uext4 for supplying the sensors is defective, for example due to overload or short circuit.
Platform fault for BiG X only: A disturbance was detected at the intake/header (broken cable/short circuit to one of the valves Q55 - Q58 or a broken cable/short circuit from relay Q72). The voltage group relay
UB2 was therefore switched off.
Configuration of the machine is not compatible with the hardware.
KMC-521350-11 Control unit - General disturbance
Page 4
Error number
KMC-521351-11
Error text
Control unit - General disturbance
Description
KMC-522002-18 Rotational speed of discharge rollers
- Lower limit value below minimum
The rotational speed of the discharge rollers is too low.
KMC-522004-16 steering axle - Upper limit value exceeded
The steering axle could not be locked within the specified time.
KMC-522012-2
KMC-522014-7
Rotational speed of PTO shaft - Logic error electronics tailgate - Logic fault mechanics
The sensor "rotational speed PTO shaft" has not been correctly set or is defective.
The tailgate is open.
Figure
KMC-522018-16 tailgate - Upper limit value exceeded The tailgate could not be closed within the specified time.
KMC-522023-16 front wall - Upper limit value exceeded
The front wall does not move.
KMC-522026-7 pick-up - Logic fault mechanics The pick-up has stopped.
KMC-522028-18 central lubrication unit - Lower limit value below minimum
During active lubrication no lubrication flow was detected.
KMC-522029-16
KMC-522030-16
Grinding device - Upper limit value exceeded
Grinding device - Upper limit value exceeded
The grinding device stops when approaching the grinding position.
The grinding device stops when grinding.
KMC-522031-7
KMC-522034-2 forced steering - Logic fault mechanics forced steering - Logic error electronics
The forced steering is not supplied with pressure.
The speed difference between the left and right wheel sensor is not plausible.
KMC-522039-16 lift axle - Upper limit value exceeded The lift axle could not be lifted within the specified time.
KMC-522040-16 articulated drawbar - Upper limit value exceeded
The articulated drawbar does not move.
KMC-522041-16 pick-up - Upper limit value exceeded The pick-up could not be lifted within the specified time.
Page 5
Error number
KMC-522042-7
KMC-522043-7
KMC-522101-3
Error text tailgate - Logic fault mechanics
Description
The tailgate unexpectedly left the open position.
Figure
Loading space cover - Logic fault mechanics
Sensor B1 position blade cassette -
Cable break
The loading space cover moves unexpectedly.
KMC-522101-4
KMC-522102-3
Sensor B1 position blade cassette -
Short circuit to ground or UB
Sensor B2 Loading height at front reached - Cable break
KMC-522102-4
KMC-522103-3
Sensor B2 Loading height at front reached - Short circuit to ground or
UB
Sensor B3 Wagon completely filled -
Cable break
KMC-522103-4
KMC-522104-3
Sensor B3 Wagon completely filled -
Short circuit to ground or UB
Sensor B4 Rotational speed of discharge rollers - Cable break
KMC-522104-4
KMC-522105-3
Sensor B4 Rotational speed of discharge rollers - Short circuit to ground or UB
Sensor B5 Rotational speed of PTO shaft - Cable break
KMC-522105-4
KMC-522106-3
Sensor B5 Rotational speed of PTO shaft - Short circuit to ground or UB
Sensor B6 Tailgate closed - Cable break
KMC-522106-4
KMC-522107-3
Sensor B6 Tailgate closed - Short circuit to ground or UB
Sensor B7 Steering axle locked -
Cable break
KMC-522107-4 Sensor B7 Steering axle locked -
Short circuit to ground or UB
Page 6
Error number
KMC-522108-3
Error text
Sensor B8 Tailgate open - Cable break
KMC-522108-4
KMC-522110-3
Sensor B8 Tailgate open - Short circuit to ground or UB
Sensor B10 Lift axle top - Cable break
KMC-522110-4
KMC-522120-3
Sensor B10 Lift axle top - Short circuit to ground or UB
Sensor B20 Oil pressure scraper conveyor - Short circuit to UB
KMC-522120-4
KMC-522124-3
Sensor B20 Oil pressure scraper conveyor - Cable break or short circuit to ground
Sensor B24 Filling pick-up accumulator - Short circuit to UB
KMC-522124-4
KMC-522125-3
Sensor B24 Filling pick-up accumulator - Cable break or short circuit to ground
Sensor B25 Pick-up top - Cable break
KMC-522125-4
KMC-522126-3
Sensor B25 Pick-up top - Short circuit to ground or UB
Sensor B26 Rotational speed of pickup - Cable break
KMC-522126-4
KMC-522128-3
KMC-522128-4
KMC-522129-3
Sensor B26 Rotational speed of pickup - Short circuit to ground or UB
Sensor B28 Inclination angle articulated drawbar - Short circuit to
UB
Sensor B28 Inclination angle articulated drawbar - Cable break or short circuit to ground
Sensor B29 Working angle pick-up -
Short circuit to UB
KMC-522129-4 Sensor B29 Working angle pick-up -
Cable break or short circuit to ground
Description Figure
Page 7
Error number
KMC-522132-3
Error text
Sensor B32 Grinding device swivelled in - Cable break
Description
KMC-522132-4
KMC-522135-3
Sensor B32 Grinding device swivelled in - Short circuit to ground or UB
Sensor B35 Position loading area cover on left - Cable break
KMC-522135-4
KMC-522136-3
Sensor B35 Position loading area cover on left - Short circuit to ground or UB
Sensor B36 Position loading area cover on right - Cable break
KMC-522136-4
KMC-522137-3
Sensor B36 Position loading area cover on right - Short circuit to ground or UB
Sensor B37 Front wall at front -
Cable break
KMC-522137-4
KMC-522138-3
Sensor B37 Front wall at front - Short circuit to ground or UB
Sensor B38 Inclination angle front wall - Short circuit to UB
KMC-522138-4
KMC-522139-3
Sensor B38 Inclination angle front wall - Cable break or short circuit to ground
Sensor B39 Central lubrication active
- Cable break
KMC-522139-4
KMC-522150-4
KMC-522151-4
KMC-522152-4
KMC-522153-3
Sensor B39 Central lubrication active
- Short circuit to ground or UB
Switch/momentary switch S51
System pressure steering - Cable break or short circuit to ground
Sensor B51 Steering angle tractor/ drawbar - Cable break or short circuit to ground
Sensor B52 Steering angle rear axle
- Cable break or short circuit to ground
Sensor B53 Driving speed left - Cable break
Figure
Page 8
Error number
KMC-522154-3
Error text
Sensor B54 Driving speed right -
Cable break
KMC-522155-4
KMC-522171-3
Sensor B55 Steering angle front axle
- Cable break or short circuit to ground
Sensor BM1 Distance grinding discs to blades - Short circuit to UB
Description
KMC-522171-4
KMC-522172-3
Sensor BM1 Distance grinding discs to blades - Cable break or short circuit to ground
Sensor BM2 Position grinding discs -
Short circuit to UB
KMC-522172-4
KMC-522177-3
Sensor BM2 Position grinding discs -
Cable break or short circuit to ground
Sensor B7 Steering axle locked -
Short circuit to UB
KMC-522177-4 Sensor B7 Steering axle locked -
Cable break or short circuit to ground
KMC-522201-16
KMC-522201-18
KMC-522203-16
Sensor B15 Force measurement front wall - Upper limit value exceeded
Sensor B15 Force measurement front wall - Lower limit value below minimum
Sensor B11 Weight measurement drawbar - Upper limit value exceeded
KMC-522203-18
KMC-522204-16
KMC-522204-18
KMC-522251-3
Sensor B11 Weight measurement drawbar - Lower limit value below minimum
Sensor
- B12L Weight measurement axle left
- B12R Weight measurement axle right
- Upper limit value exceeded
Sensor
- B12L Weight measurement axle left
- B12R Weight measurement axle right
- Lower limit value below minimum
Switch/momentary switch S1 Swivel in blade cassette - Cable break
Figure
Page 9
Error number
KMC-522251-4
KMC-522251-7
KMC-522252-3
Error text
Switch/momentary switch S1 Swivel in blade cassette - Short circuit to ground or UB
Switch/momentary switch S1 Swivel in blade cassette - Logic fault mechanics
Switch/momentary switch S2 Swivel out blade cassette - Cable break
Description
Button clamp
KMC-522252-4
KMC-522252-7
KMC-522253-3
KMC-522253-4
KMC-522253-7
KMC-522254-3
Switch/momentary switch S2 Swivel out blade cassette - Short circuit to ground or UB
Switch/momentary switch S2 Swivel out blade cassette - Logic fault mechanics
Switch/momentary switch S3 Lift articulated drawbar - Cable break
Button clamp
Switch/momentary switch S3 Lift articulated drawbar - Short circuit to ground or UB
Switch/momentary switch S3 Lift articulated drawbar - Logic fault mechanics
Switch/momentary switch S4 Lower articulated drawbar - Cable break
Button clamp
KMC-522254-4
KMC-522254-7
KMC-522255-3
KMC-522255-4
KMC-522255-7
KMC-522301-3
Switch/momentary switch S4 Lower articulated drawbar - Short circuit to ground or UB
Switch/momentary switch S4 Lower articulated drawbar - Logic fault mechanics
Switch/momentary switch S5
Grinding device ON - Cable break
Button clamp
Switch/momentary switch S5
Grinding device ON - Short circuit to ground or UB
Switch/momentary switch S5
Grinding device ON - Logic fault mechanics
Valve K1 Scraper conveyor forwards -
Cable break or short circuit to UB
Button clamp
KMC-522301-6 Valve K1 Scraper conveyor forwards -
Short circuit to ground
Figure
Error number
KMC-522302-3
KMC-522302-6
KMC-522303-3
Error text
Valve Q2 Scraper conveyor backwards - Cable break or short circuit to UB
Valve Q2 Scraper conveyor backwards - Short circuit to ground
Description
Valve Q3 Pilot valve 1 - Cable break or short circuit to UB
KMC-522303-6
KMC-522304-3
Valve Q3 Pilot valve 1 - Short circuit to ground
Valve Q4 Pilot valve 2 - Cable break or short circuit to UB
KMC-522304-6
KMC-522305-3
Valve Q4 Pilot valve 2 - Short circuit to ground
Valve Q5 Pick-up 1 - Cable break or short circuit to UB
KMC-522305-6
KMC-522306-3
Valve Q5 Pick-up 1 - Short circuit to ground
Valve Q6 Tailgate 1 - Cable break or short circuit to UB
KMC-522306-6
KMC-522307-3
Valve Q6 Tailgate 1 - Short circuit to ground
Valve Q7 Tailgate 2 - Cable break or short circuit to UB
KMC-522307-6
KMC-522308-3
Valve Q7 Tailgate 2 - Short circuit to ground
Valve Q8 Articulated drawbar 1 -
Cable break or short circuit to UB
KMC-522308-6
KMC-522309-3
Valve Q8 Articulated drawbar 1 -
Short circuit to ground
Valve Q9 Articulated drawbar 2 -
Cable break or short circuit to UB
KMC-522309-6 Valve Q9 Articulated drawbar 2 -
Short circuit to ground
Page 10
Figure
Error number
KMC-522310-3
Error text
Valve Q10 Blade cassette 1 - Cable break or short circuit to UB
Description
KMC-522310-6
KMC-522311-3
Valve Q10 Blade cassette 1 - Short circuit to ground
Valve Q11 Blade cassette 2 - Cable break or short circuit to UB
KMC-522311-6
KMC-522312-3
KMC-522312-6
KMC-522313-3
KMC-522313-6
Valve Q11 Blade cassette 2 - Short circuit to ground
Valve
- Q12.1 Rapid traverse of floor conveyor 1
- Q12.2 Rapid traverse of floor conveyor 2
- Cable break or short circuit to UB
Valve
- Q12.1 Rapid traverse of floor conveyor 1
- Q12.2 Rapid traverse of floor conveyor 2
- Short circuit to ground
Valve Q13 Load Sensing active -
Cable break or short circuit to UB
Valve Q13 Load Sensing active -
Short circuit to ground
KMC-522314-3
KMC-522314-6
Valve Q14 Coupling discharge rollers
- Cable break or short circuit to UB
Valve Q14 Coupling discharge rollers
- Short circuit to ground
KMC-522315-3
KMC-522315-6
Valve Q15 steering axle - Cable break or short circuit to UB
Valve Q15 steering axle - Short circuit to ground
KMC-522318-3
KMC-522318-6
Valve Q18 Pick-up 2 - Cable break or short circuit to UB
Valve Q18 Pick-up 2 - Short circuit to ground
KMC-522319-3 Valve Q19 lift axle - Cable break or short circuit to UB
Page 11
Figure
Error number
KMC-522319-6
Error text
Valve Q19 lift axle - Short circuit to ground
Description
KMC-522321-3
KMC-522321-6
Valve K21 Pick-up drive - Cable break or short circuit to UB
Valve K21 Pick-up drive - Short circuit to ground
KMC-522326-3
KMC-522326-6
Valve K26 Pick-up relief - Cable break or short circuit to UB
Valve K26 Pick-up relief - Short circuit to ground
KMC-522328-3
KMC-522328-6
Valve Q28 Rapid traverse of floor conveyor 1 - Cable break or short circuit to UB
Valve Q28 Rapid traverse of floor conveyor 1 - Short circuit to ground
KMC-522329-3
KMC-522329-6
Valve Q29 Rapid traverse of floor conveyor 2 - Cable break or short circuit to UB
Valve Q29 Rapid traverse of floor conveyor 2 - Short circuit to ground
KMC-522330-3
KMC-522330-6
Valve Q30.1 Chopping flap 1 - Cable break or short circuit to UB
Valve Q30.1 Chopping flap 1 - Short circuit to ground
KMC-522331-3
KMC-522331-6
Valve Q30.2 Chopping flap 2 - Cable break or short circuit to UB
Valve Q30.2 Chopping flap 2 - Short circuit to ground
KMC-522332-3
KMC-522332-6
Valve Q32 Grinding discs drive -
Cable break or short circuit to UB
Valve Q32 Grinding discs drive -
Short circuit to ground
KMC-522335-3 Valve Q35.1 Loading space cover 1 -
Cable break or short circuit to UB
Page 12
Figure
Error number
KMC-522335-6
Error text
Valve Q35.1 Loading space cover 1 -
Short circuit to ground
Description
KMC-522336-3
KMC-522336-6
Valve Q35.2 Loading space cover 2 -
Cable break or short circuit to UB
Valve Q35.2 Loading space cover 2 -
Short circuit to ground
KMC-522337-3
KMC-522337-6
Valve Q37.1 Front wall 1 - Cable break or short circuit to UB
Valve Q37.1 Front wall 1 - Short circuit to ground
KMC-522338-3
KMC-522338-6
Valve Q37.2 Front wall 2 - Cable break or short circuit to UB
Valve Q37.2 Front wall 2 - Short circuit to ground
KMC-522339-3
KMC-522339-6
Valve Q39 central lubrication unit -
Cable break or short circuit to UB
Valve Q39 central lubrication unit -
Short circuit to ground
KMC-522351-23
KMC-522352-23
KMC-522353-23
KMC-522354-23
KMC-522355-23
KMC-522356-23
KMC-522357-23
Valve Q51 Release rear axle 1 -
Cable break, short circuit to earth or short circuit to UB
Valve Q52 Release rear axle 2 -
Cable break, short circuit to earth or short circuit to UB
Valve K53 Control rear axle 2 - Cable break, short circuit to earth or short circuit to UB
Valve K54 Control rear axle 1 - Cable break, short circuit to earth or short circuit to UB
Valve Q55 Release front axle 1 -
Cable break, short circuit to earth or short circuit to UB
Valve Q56 Release front axle 2 -
Cable break, short circuit to earth or short circuit to UB
Valve K57 Control front axle 2 - Cable break, short circuit to earth or short circuit to UB
Page 13
Figure
Error number
KMC-522358-23
KMC-522371-3
KMC-522371-6
KMC-522372-3
Error text
Valve K58 Control front axle 1 - Cable break, short circuit to earth or short circuit to UB
Description
Engine M1 Axial displacement grinding discs - Cable break or short circuit to UB
Engine M1 Axial displacement grinding discs - Short circuit to ground
Engine M2 Lift/lower grinding discs -
Cable break or short circuit to UB
KMC-522372-6 Engine M2 Lift/lower grinding discs -
Short circuit to ground
KMC-522375-3
KMC-522375-6
Signal device H1 Warning signal tailgate - Cable break or short circuit to UB
Signal device H1 Warning signal tailgate - Short circuit to ground
KMC-522381-3
KMC-522381-6
KMC-522390-3
Lamp
- E6 Light strip front right
- E7 Light strip rear right
- E8 Light strip front left
- E9 Light strip rear left
- Cable break or short circuit to UB
Lamp
- E6 Light strip front right
- E7 Light strip rear right
- E8 Light strip front left
- E9 Light strip rear left
- Short circuit to ground
Valve Q25 Plug silage additives unit -
Cable break or short circuit to UB
KMC-522390-6 Valve Q25 Plug silage additives unit -
Short circuit to ground
KMC-522506-19 TECU - Disturbance
KMC-522510-19 ISB - Disturbance
KMC-522511-12 ISB - Internal Error
KMC-522530-19 SLC - Disturbance
Page 14
Figure
Error number
KMC-522531-12
Error text
SLC - Internal Error
KMC-522532-4 SLC - Undervoltage
KMC-522535-19 TEBS - Disturbance
KMC-522536-12 TEBS - Internal Error
KMC-522537-4 TEBS - Undervoltage
KMC-522540-19 KMB 1 - Disturbance
KMC-522541-4 KMB 1 - Undervoltage
KMC-522542-12 KMB 1 - Internal Error
KMC-522543-3 KMB 1 - Overvoltage
KMC-522545-19 KMB 2 - Disturbance
KMC-522546-4 KMB 2 - Undervoltage
KMC-522547-12 KMB 2 - Internal Error
KMC-522548-3 KMB 2 - Overvoltage
KMC-522560-19 FMA 1 - Disturbance
KMC-522561-4 FMA 1 - Undervoltage
KMC-522562-12 FMA 1 - Internal Error
Description
Page 15
Figure
Error number
KMC-522563-3
Error text
FMA 1 - Overvoltage
KMC-522565-19 FMA 2 - Disturbance
KMC-522566-4 FMA 2 - Undervoltage
KMC-522567-12 FMA 2 - Internal Error
KMC-522568-3 FMA 2 - Overvoltage
KMC-522580-19 FM 1 - Disturbance
KMC-522581-4 FM 1 - Undervoltage
KMC-522582-12 FM 1 - Internal Error
KMC-522583-3 FM 1 - Overvoltage
KMC-522650-19 KP 1 - Disturbance
KMC-522651-4 KP 1 - Undervoltage
KMC-522652-12 KP 1 - Internal Error
KMC-522653-3 KP 1 - Overvoltage
KMC-522655-19 KP 2 - Disturbance
KMC-522656-4 KP 2 - Undervoltage
KMC-522657-12 KP 2 - Internal Error
Description
Page 16
Figure
Error number
KMC-522658-3
Error text
KP 2 - Overvoltage
Description Figure
Page 17
Information messages
Information list
4
4.1
4 Information messages
4.1
I - 2001
FULL
EQ001-223
An information message is indicated in the display to ensure smooth running of the machine functions. At the same time, an audio signal will be heard (continuous horn signal). For a list of information messages
.
The information message is structured according to the following sample: e.g. information
I message "I-2001 FULL "
Information message
2001 FULL
Information message number Icon
Acknowledging the information message
Make a note of the information message.
Briefly press on .
Æ The acoustic signal stops and the information message is no longer indicated.
Check the information message, see Page 25
.
The following key function can be selected:
The following key functions can be selected:
Icon Designation
Acknowledging the information message
Explanation
If the disturbance occurs again, the information message will be displayed again.
Information list
>>>
2
Loading and Forage Transport Wagon
Supplement to operating instructions 150001730_00_en 25
Stiahnuť
Reklama