6.10.2 EDID Settings

Click on 'EDID Settings' to select EDID Mode and Set EDID Input content for each HDMI input.

6.10.3 Macro Settings

Macro 1~8 works align with Trigger IN 1~8 which means, when a trigger signal is activated the control system will execute the command under Macro Setting.

Click on 'Macro Settings' to execute Macro action. Click on the mark to edit the command settings up to 8 Macro sets and to set its parameter and delay time of command up to 16 per each Macro.

Click on Add button to insert commands. Command can be set to control the Control System/SysCMD, other devices connected within the same Telnet system/Internet area, RS-232 COM ports, IR and Relay devices connected through the Relay outputs of Control System with delay time. It is suggested the delay time is >100ms once the setting is confirmed, double click on Save Change.

19

Command set to control the devices within the same telnet system or internet area require to set its IP and Port number and it is strongly recommend to set the delay time >500ms in order to secure a successful command sending. Command set to control the Relay devices require to set the Port number. Click on Save Change to confirm the setting.

Command under 128 characters including space can be build up to 128 commands, command over 128 characters and under 512 characters including space can be build up to 32 command in addition with 96 commands of 128 characters under. Click on Save

Change to save the command inserted.