Characteristics. Schneider Electric Software Communication Application-Specific Functions, Micro/Junior/Pro, 4.5
Annonce
Annonce
Fipway Communication: General
1.2
Characteristics
Introduction
Aim of this
Section
What's in this
Section?
This Section introduces the characteristics and constraints of using Fipway communication.
This section contains the following topics:
Topic
Hardware compatibility
Software compatibility
Performance
Operating mode
Page
24
35011050 01 July 2006
Fipway Communication: General
Hardware compatibility
General
Availability
Capacity
The binary output of the network is 1 Mbits/s.
The length of a segment depends on the type of branching. The maximum length is
1000 meters without a repeater.
When using repeaters (optic or electric), the maximum length between the two furthest stations depends on the number of repeaters which must be crossed.
The maximum length in km is calculated with the following formula:
L = 22 - (0,5 * R) where R is the number of repeaters crossed by the FIP data between the two stations.
The FIPIO bus is connected to the Hirschmann optic transmitters, with the
TSX FPP 200 PCMCIA card.
This type of communication is available for these PLCs: z
Premium via the intermediary of: z z z the TSX FPP 20 PCMCIA card, the TSX FPP 200 PCMCIA card.
Micro accepts the PCMCIA cards described below (TSX 37-21/22 PLCs).
A FIPWAY network segment is used to connect 36 devices. The devices for a
FIPWAY network can be: z z stations with the constraint of a maximum of 32 stations per segment, repeaters with the constraint of a maximum of 32 repeaters per segment,
On all the segments, a maximum of 64 stations can be connected to the network.
35011050 01 July 2006
25
Fipway Communication: General
Software compatibility
Message handling
Common words
Shared table
The maximum frame size depends on the type of transaction: z
For a message, the maximum frame is 128 bytes.
z
For a telegram, the maximum frame is 16 bytes.
Equally, the PCMCIA cards can process: 8 communication functions simultaneously
(8 in receive and 8 in send mode).
z for messages, 8 communication functions simultaneously (8 in send and 8 in receive mode).
z for telegrams, one single communication function (one in send and one in receive mode).
The common words service is supported by the stations at addresses between
0 and 31.
This database is made up of a maximum of 128 words for all the stations.
Each station can produce a maximum of between 0 and 4 common words and consume the other common words on the network.
The shared table service is supported by the stations at addresses between
0 and 31.
This database is made up of a maximum of 128 words for all the stations.
Each station can produce a maximum of between 1 and 32 words (defined in configuration mode) and consume the other words on the network.
26
35011050 01 July 2006
Fipway Communication: General
Performance
Transaction time The following table gives the transaction time between two stations:
Sending station Cyclic
Periodic 50 ms
Receiving station
Cyclic
50 ms
120 ms
Periodic 50 ms
-
160 ms
The telegram exchange time between two stations is 21 ms.
35011050 01 July 2006
27
Fipway Communication: General
Operating mode
Introduction
General chart
The following chart describes the operating modes of the TSX FPP 20 card.
The operating mode is as follows:
Module stopped
Module off
Power up
Operation
Module configured
Reset
Communication function
Module in self-test phase
Module not configured Self-tests OK
Configuration z z z z
After power-up the module self-tests. During this phase the LED indicators flash.
If there is no configuration, the card operates in message handling mode, and it can receive a PL7 configuration.
If there is a PL7 application in the PLC, the configuration of the application is transmitted to the module and the module starts up.
In case of power outage, the PLC processor performs a warm restart. The module then re-launches its self-test procedure.
28
35011050 01 July 2006
Configuring Fipway communication
2
Introduction
Subject of this
Chapter
What's in this
Chapter?
This Chapter describes the Configuration process during set-up of Fipway communication.
This chapter contains the following topics:
Topic
How to access the FIPWAY configuration screen
FIPWAY configuration screen
FIPWAY parameters linked to the telegrams and to the physical layer
FIPWAY parameters linked to the common data
Example of configuration of shared table service
Page
35011050 01 July 2006
29
Configuration
How to access the FIPWAY configuration screen
Introduction
How to access the link
This operation describes how to access the configuration parameters of the
FIPWAY link via the intermediary of the PCMCIA cards for Premium PLCs.
The following table shows the procedure for accessing the FIPWAY link:
Step
1
2
Action
Access the communication channel configuration screen.
Select the communication channel from the drop-down menu CHANNEL 1
Example
CHANNEL 0
CHANNEL 1
CHANNEL 1
(No PCMCIA submodule)
(Link not configured) MAST
3 Select one of the following PCMCIA cards from the drop-down menu: z TSX FPP 20 FIPWAY PCMCIA CARD z TSX FPP 200 FIPWAY PCMCIA CARD
Example
CHANNEL 1
CHANNEL 1 (No PCMCIA submodule)
(Link not configured)
TSX SCP 114 PCMCIA CARD RS485 MP
TSX FPP 20 PCMCIA FIPWAY CARD
TSX FPP 200 PCMCIA FIPWAY CARD
TSX FPP 10 PCMCIA FIPIO CARD
TSX MBP 100 PCMCIA MODBUS+ CARD
TSX MDM 10 PCMCIA MODEM CARD
30
35011050 01 July 2006
Configuration
FIPWAY configuration screen
Introduction
Illustration
This screen, split into two zones, is used to declare the communication channel and to configure the necessary parameters for a FIPWAY link.
The screen dedicated to FIPWAY communication looks like this:
1
2
TSX 57352 [RACK 0 POSITION 0]
Configuration
Designation: PROCESSOR TSX P 57352
CHANNEL 1
CHANNEL 1
FIPWAY
TSX FPP 20 PCMCIA FIPWAY CARD
MAST
Telegram
Telegram Management
Event processing 63
Physical layer
FIP
CB
Common Data
None
Common words:
Shared table (ST)
Bridge
Network Number
Table start address %MW
Produced zone address %MW
Length of produced zone in words
1
0
0
1
Elements and functions
This table describes the different zones that make up the configuration screen:
Address Zone
1 common
2 specific
Function
See (Communication applications Volume 1 - Overwiew of configuration screen).
is used to select or complete the parameters of a FIPWAY link.
It is split into three types of information: z Telegram management parameters, z z the parameters for the physical layer, the parameters for the common data.
35011050 01 July 2006
31
Configuration
FIPWAY parameters linked to the telegrams and to the physical layer
Introduction
Telegram window
Once the communication channel has been configured, complete the parameters dedicated to the telegrams and to the physical layer.
They are split into two windows: z the Telegram window, z the Physical layer window.
The window looks like this:
Telegram
Telegram Management
Event processing 63
It is used to complete: z
Telegram management : if the box is checked, the card is used to manage the z telegrams (default setting).
Event processing : this option is accessible only if telegram management has been activated. This option is used to manage the telegrams via an event task. If the box is checked, you must complete the number of the task where the telegrams will be processed.
The possible values are: z z z between 0 and 15 for Micro PLCs, between 0 and 31 for Premium PLCs of type TSX 57-10, between 0 and 63 for Premium PLCs of type TSX 57-20 and higher.
Note: If there is a PCMCIA in the module TSX SCY 21600/21601, telegram management is obligatory.
Physical layer window
The window looks like this:
Physical layer
FIP
CB
It is used to select the physical layer used for the communication.
Note: Only the physical layer specific to FIP is available.
32
35011050 01 July 2006
Configuration
FIPWAY parameters linked to the common data
Introduction
None
Common words
The window looks like this:
Common Data
None
Common Words
Shared table (ST)
Bridge
Network Number
Table start address %MW
Produced zone address %MW
Length of produced zone in words
1
0
0
1
It can be used to: z z z activate or deactivatethe exchange management of common data select the type of common data to exchange, complete the parameters necessary for this type of exchange.
Select this button if you wish to disable the management of common data in the application.
Select this button if you wish to have management of common data by common words (%NW).
When selecting this field, you must enter the local Network number to which the database is connected.
Note: The local network number corresponds to the number coded on the PCMCIA card.
Shared table Select this button if you wish to have management of common data by shared table.
When selecting this field, you must complete the following parameters: z
Table start address : this parameter shows the start of the table of internal words reserved in the PLC.
z
The 128 words following the start of the table will be reserved for the shared table function and are common to all stations.
Produced zone address : this parameter shows the address of the start of the zone of internal words produced by the station.
z
The address entered must take into account zones of internal words of the other stations. You must avoid an overlap of word zones between two stations.
Length of produced zone : this parameter shows the length (in words) of the table of internal words produced by the PLC (from 1 to 32 words).
35011050 01 July 2006
33
Configuration
Bridge This button is used to configure the routing function between networks.
See
Multi-network architectures, p. 289
34
35011050 01 July 2006
Configuration
Example of configuration of shared table service
Introduction The example shows how the stations are configured for using the shared table service.
These configurations use the example described in using shared tables.
Configuration of station 1
The example shows the configuration for station 1.
Common Data
None
Common Words
Shared table (ST)
Bridge
Network Number
Table start address %MW
Produced zone address %MW
Length of produced zone in words
17
200
200
10
Configuration of station 2
The example shows the configuration for station 2.
Common Data
None
Common Words
Shared table (ST)
Bridge
Network Number
Table start address %MW
Produced zone address %MW
Length of produced zone in words
17
300
310
20
The zone produced by the station starts at address %MW310.
The corresponding zone of %MW300 to %MW309 is reserved for the words produced by station 1.
35011050 01 July 2006
35
Configuration
Configuration of station 3
The example shows the configuration for station 3.
Common Data
None
Common Words
Shared table (ST)
Bridge
Network Number
Table start address %MW
Produced zone address %MW
Length of produced zone in words
17
400
430
5
The zone produced by the station starts at address %MW430.
The corresponding zone of %MW400 to %MW409 is reserved for the words produced by station 1.
The corresponding zone of %MW410 to %MW429 is reserved for the words produced by station 2.
36
35011050 01 July 2006
Debugging Fipway communication
3
Introduction
Subject of this
Chapter
What's in this
Chapter?
This Chapter describes the Debugging process during set-up of Fipway communication.
This chapter contains the following topics:
Topic
FIPWAY debugging screen
FIPWAY debugging parameters
Requests available for the communication channel test
How to test a channel with Identification and Mirror requests
How to test a channel with requests
Page
35011050 01 July 2006
37
Debugging
FIPWAY debugging screen
Introduction
Illustration
This screen, split into two zones, is used to debug a FIPWAY link.
The screen dedicated to FIPWAY communication looks like this:
1
2
TSX 57352 [RACK 0 POSITION 1]
Debugging
Designation: TSX P 57352 PROCESSOR Version: 3.3
CHANNEL 1
CHANNEL 1
FIPWAY
TSX FPP 20 PCMCIA FIPWAY CARD
MAST
Channel Information
Network address
Station Address
23 Bus arb.
8
Bridge
Common data Common Words
Channel Test
Identification
Message Errors
Messages sent and not acknowledged
Message Refused
Receive Response
Reset Counters
Counters
Reset Counters
Enter Request
Mirror
ASCII Hex.
Stations
DIAG...
DIAG...
0
0
Elements and functions
This table describes the different zones that make up the debugging screen:
Address Zone
1 common
2 specific
Function
See (Communication applications Volume 1 - Description of communication debugging screens).
is used to access the debugging parameters of a FIPWAY link.
It is split into three windows: z z z information on the channel, information on the message errors, the possibility of testing the communication channel.
38
35011050 01 July 2006
Debugging
FIPWAY debugging parameters
Introduction
Channel information
Message errors
The specific part is split into three windows: z z z the Channel information window, the Message errors window, the Channel test window.
The window looks like this:
Channel Information
Network address
Station Address
23 Bus arb.
8
Bridge
Common data Common Words
It shows information concerning the communication channel: z
Network address : this field indicates the network address coded on the PCMCIA card.
z z
Station address : this field indicates the station address coded on the PCMCIA card.
Common data : this field shows the type of common data selected in configuration mode.
z z
B.A.
: this field indicates if the local PCMCIA card is the bus arbiter of the FIPWAY network. In this case, the box is shaded.
Router : this field indicates if the local PCMCIA card is configured as a Bridge
(router). In this case, the box is shaded.
The window looks like this:
Message Errors
Messages sent and not acknowledged
Messages Refused
Reset Counters
0
0
This window displays the PCMCIA card error counters: z z
Messages sent and not acknowledged ,
Messages refused .
The button Reset Counters resets these counters.
35011050 01 July 2006
39
Debugging
Channel test The window looks like this:
Channel Test
6
14
Identification
Counters
Reset Counters
Enter Request
Mirror
Stations
Receive Response
...TSX FPP20.../...
ASCII Hex.
This window is used to test a communication channel by sending a request to one of the stations on the network.
40
35011050 01 July 2006
Debugging
Requests available for the communication channel test
Introduction
Test conditions
Available requests
This page describes the different possibilities for testing a communication channel from the debugging screen.
Sending a request to an unconnected station results in an error message.
The Channel Test window allows the following requests: z
Identification : prompts the Identification request to be sent to the designated slave, z z
Counters : prompts the Read error counters request to be sent to the designated station,
Reset Counters : prompts the designated station’s error counters to be reset to zero, z z
Enter request : allows a UNI-TE request, other than those provided by the command buttons, to be sent to the designated station. Selecting this function gives access to a screen that allows you to select the parameters that are specific to the request (request code must be coded in hexadecimal),
Mirror : allows a mirror request to be sent to the designated station. Selecting this function gives access to a screen that allows you to select the length of the character string to be sent (a maximum of 80 characters ). The PLC then sends this character string (ABCD….) to the destination device. The latter automatically sends the character string that was received back to the sender.
35011050 01 July 2006
41
Debugging
How to test a channel with Identification and Mirror requests
Introduction This page indicates the procedure for testing a communication channel by means of
Identification and Mirror requests.
How to identify a station
The following procedure is used to identify a designated station.
Step
1
2
Actions
Select the address of the station to be interrogated using the Station field.
Click on the Identification button.
Result
The response appears in the Receive Response window:
Receive Response
...TSX FPP20.../...
ASCII Hex.
42
35011050 01 July 2006
Debugging
How to send the
Mirror request
The following procedure is used to send the Mirror request and thus to test the routing of information between two devices.
Step
1
2
Action
Select the address of the station to be interrogated using the Station field.
Click on the Mirror button.
Result
The following window appears:
Mirror Request
Length of data to be sent
Send Cancel
8
3
4
Enter the length of data to be sent (maximum 80 characters).
Click on the Send button.
Result
The response appears in the Receive Response window:
Receive Response
ABCDEFGH
ASCII Hex.
The response contains: z the character string ABCDEFGH that corresponds to the length of data sent 8.
35011050 01 July 2006
43
Debugging
How to test a channel with requests
Introduction
How to send a request
This page indicates the procedure for testing a communication channel from the debugging screen using different requests.
The following procedure is used to send a request, other than those provided by the command buttons, to a designated station.
Step
1
2
Action
Select the address of the station to be interrogated using the Station field.
Click on the Enter Request button.
Result
The following window appears:
Enter Request
Request Code (Hexadecimal)
fa
Data (Hexadecimal)
1234db
3
4
5
Send Cancel
The data sent in this example is coded on 3 bytes.
Enter the function code (coded in hexadecimal on one byte), corresponding to the request that you want to send.
Enter the data to be sent by coding all the data in hexadecimal. Enter the data continuously without any intervening spaces.
Click on the Send button.
Result
The response appears in the Receive Response window:
Receive Response
1234DB
ASCII Hex.
the response from the example has data on 3 bytes (12 43 DB).
44
35011050 01 July 2006
Language objects associated with
FIPWAY communication
4
Introduction
Aim of this section
What's in this
Chapter?
This chapter introduces the language objects linked to FIPWAY communication.
This chapter contains the following topics:
Topic
Language object for implicit exchange
Language objects in explicit exchange
Explicit exchange management and reports
Language objects associated with the configuration
Page
45
35011050 01 July 2006
FIPWAY language objects
Language object for implicit exchange
Introduction
Bit objects
This page describes all the language objects for implicit exchange in FIPWAY communication that can be displayed or modified by the application program.
(Communication applications Volume 1 - Default exchanges)
The table below shows the different bit objects for implicit exchange.
Object (1) Function
%Ixy.MOD.ERR Module error bit
%Ixy.i.ERR
Channel error bit
Meaning
This bit set to 1, indicates a module error (at least one of the channels has an error, for instance.
This bit set to 1, indicates a line fault.
Key
(1) Address xy.i
z x: corresponds to the rack number z z y: corresponds to the module number i: corresponds to the channel number
46
35011050 01 July 2006
Word objects
FIPWAY language objects
The table below shows the different word objects for implicit exchange.
Object (1)
%IWxy.i.0
%IWxy.i.1
...
%IWxy.i.5
Function
Network status
Common data refresh flags
...
Common data refresh flags z z z z z z z z
Meaning z x0 = 1: if at least one of the stations is present z z x0 = 1: the common words or the words from the shared table from station 0 are refreshed.
...
x7 = 1: the common words or the words from the shared table from station 7 are refreshed.
x8 = 1: the common words or the words from the shared table from station 0 are refreshed.
...
x15 = 1: the common words or the words from the shared table from station 7 are refreshed.
...
z z x0 = 1: the common words or the words from the shared table from station 48 are refreshed.
...
x7 = 1: the common words or the words from the shared table from station 55 are refreshed.
x8 = 1: the common words or the words from the shared table from station 56 are refreshed.
...
x15 = 1: the common words or the words from the shared table from station 63 are refreshed.
Key
(1) Address xy.i
z x: corresponds to the rack number z z y: corresponds to the module number i: corresponds to the channel number
Common words The following table describes the words of the input channels:
Object
%NW{n.s}0 to
%NW{n.s}3
Function
Common words
Meaning corresponds to the exchanged common data
35011050 01 July 2006
47
FIPWAY language objects
Language objects in explicit exchange
Introduction This page describes all the language objects for explicit exchange in FIPWAY communication that can be displayed or modified by the application program.
(Communication applications Volume 1 - Specified exchanges: General points)
48
35011050 01 July 2006
Word objects
FIPWAY language objects
The table below shows the different word objects for explicit exchange.
Object (1) Function
%MWxy.MOD.2
Module status
%MWxy.i.2
%MWxy.i.3
%MWxy.i.4
%MWxy.i.5
%MWxy.i.6
Standard channel status
Specific channel status
Error counters
Error counters
Network/station address z z z z z z z z
Meaning x0 = 1: defective module x1 = 1: functional error (error between the processor and the module, adjustment or configuration error, etc.) x2 = 1: terminal block fault (not connected) x3 = 1: self-tests running x4 = 1: reserved x5 = 1: error in hardware or software configuration (the module present is not that declared in the configuration, the sub-modules are not compatible) x6 = 1: missing module x7 = 1: error in one of the sub-modules z z z z z z z x0 = 1: only station on the network x1 = 1: not used x2 = 1: transmission line error x3 = 1: not used x4 = 1: internal software fault x5 = 1: hard- or software error or absence of configuration x6 = 1: communication problem with the processor x7 = 1: application fault (double address station) z
Byte 0: z x0 = 0: if bridge (0 if not router)
Byte 1: z z z
= 16#00: unsupported bus arbiter function
= 16#03: active bus arbiter function
= 16#20: bus arbiter function in standby
Unacknowledged messages
Refused messages
Byte 0: station number
Byte 1: network number
35011050 01 July 2006
49
FIPWAY language objects
Object (1)
%MWxy.i.7
%MWxy.i.8
...
%MWxy.i.11
Function
Common words or shared table information
Status of stations from 0 to 15
...
Status of stations from 48 to 63 z z z z z z z z z z z z z z z z z z z z z z
...
Meaning
Byte 0: z z
= 16#00: inactive service
= 16#01: read/write of common words z z
= 16#02: reading of common words
= 16#03: participation in the exchange of a shared table (operation without error)
= 16#04: overlap of the exchange zone of a z z shared table
= 16#05: exchange error of a shared table
Byte 1: size x0 = 1: station 0 present (= 0 absent) x1 = 1: station 1 present (= 0 absent) x2 = 1: station 2 present (= 0 absent) x3 = 1: station 3 present (= 0 absent) x4 = 1: station 4 present (= 0 absent) x5 = 1: station 5 present (= 0 absent) x6 = 1: station 6 present (= 0 absent) x7 = 1: station 7 present (= 0 absent) x8 = 1: station 8 present (= 0 absent) x9 = 1: station 9 present (= 0 absent) x10 = 1: station 10 present (= 0 absent) x11 = 1: station 11 present (= 0 absent) x12 = 1: station 12 present (= 0 absent) x13 = 1: station 13 present (= 0 absent) x14 = 1: station 14 present (= 0 absent) x15 = 1: station 15 present (= 0 absent) x0 = 1: station 48 present (= 0 absent)
...
x7 = 1: station 55 present (= 0 absent) x8 = 1: station 56 present (= 0 absent)
...
x15 = 1: station 63 present (= 0 absent)
Key
(1) Address xy.i
z x: corresponds to the rack number z z y: corresponds to the module number i: corresponds to the channel number
50
35011050 01 July 2006
FIPWAY language objects
Explicit exchange management and reports
Introduction
Word objects
This page describes all the language objects that manage explicit exchanges.
(Communication applications Volume 1 - Exchange and report management)
The table below shows the different word objects for the management of explicit exchanges.
Object (1) Function
%MWxy.MOD.0 Module exchanges in progress
%MWxy.MOD.1 Module report
%MWxy.i.0
%MWxy.i.1
Channel exchanges in progress
Channel report z z z z
Meaning z z z x0 = 1: status reading in progress x1 = 1: sending of command parameters to the communication module x2 = 1: sending of adjustment parameters to the communication module x1 = 0: command parameters received and accepted by the module x2 = 0: adjustment parameters received and accepted by the module z z z x0 = 1: status reading in progress x1 = 1: sending of command parameters to the communication channel x2 = 1: sending of adjustment parameters to the communication channel x1 = 0: command parameters received and accepted by the communication channel x2 = 0: adjustment parameters received and accepted by the communication channel
Key
(1) Address xy.i
z z z x: corresponds to the rack number y: corresponds to the module number i: corresponds to the channel number
35011050 01 July 2006
51
FIPWAY language objects
Language objects associated with the configuration
Introduction
Internal constants
This page describes all the configuration language objects for FIPWAY communication that can be displayed by the application program.
The following table describes the internal constants:
Object Function
%KWxy.i.0
Type
%KWxy.i.1
Physical layer
%KWxy.i.2
Supported services
Meaning
Byte 0 = 4 for FIPWAY communication
Byte 0: station address z z
= 0: FIP physical layer
= 1: WORLD FIP physical layer byte 1: reserved
Byte 0: common data z = 16#00: none z = 16#01: common words z = 16#02: shared table
Byte 1: telegrams z z
= 16#00: unsupported services
= 16#01: supported
Address of the beginning of the shared table %KWxy.i.3
Shared table information
%KWxy.i.4
Common words and shared table
Byte 0: the number of common words or size of production zone of the shared table
Byte 1: Address (in bytes) of the beginning of the production zone of the shared table
52
35011050 01 July 2006
Communication via ETHERNET network
II
Introduction
Subject of this part
What's in this
Part?
This part introduces the Communication function on the Micro/Premium PLCand describes its implementation with PL7 software.
This part contains the following chapters:
Chapter Chapter Name
5 Communication via Ethernet network
6
7
Facilities
Configuration parameters
8
9
TSX ETY 110 Module
TSX ETY 410•, TSX ETY PORT, TSX ETY 510• and TSX WMY 100 modules
Page
53
35011050 01 July 2006
ETHERNET communication
54
35011050 01 July 2006
Communication via Ethernet network
5
Introduction
Subject of this chapter
What's in this
Chapter?
This chapter introduces communication via Ethernet network and its facilities.
This chapter contains the following topics:
Topic
About ETHERNET
General Information about the TSX ETY Modules
Details of Available Functions
Page
35011050 01 July 2006
55
General points
About ETHERNET
Introduction
Associated manuals
ETHERNET communication is essentially used for the following applications: z co-ordination between PLCs, z z z local or centralized monitoring, communication with production management data processing, communication with remote inputs/outputs.
Two communication profiles are supported by the ETHERNET network modules: z the ETHWAY profile, which restarts all the devices of the X-WAY communication architecture: z
X-WAY addressing system, z z z z
UNI-TE messaging, distributed databases (common words).
TCP/IP profile on ETHERNET allowing communication in: z
UNI-TE messaging with all of the X-WAY architecture,
Modbus messaging.
The ETHERNET network modules also support the SNMP standard network management protocol as an agent.
If you require fuller information you should consult the following manuals:
Title
ETHERNET network - Reference manual
Premium TSX PL7s - Set up manual
Momentum Bases - Set up manual
Description
Detailed description of the ETHERNET network
Hardware set up
Hardware and software set up of the
Momentum TSX
56
35011050 01 July 2006
General points
General Information about the TSX ETY Modules
At a Glance ETHERNET network communication is available for Premium PLCs using: z
TSX ETY 110 and TSX ETY 110 WS modules, z z
TSX ETY 410•, TSX ETY PORT and TSX ETY 510• modules, the TSX ETY 210 module.
They have several types of interface.
The TSX ETY 110 module
Connection can be made: z to an ETHWAY profile network supporting the following utilities: z common words, z z
UNI-TE messaging, to a TCP/IP profile network supporting the following utilities: z z
UNI-TE and Modbus messaging,
SNMP management.
For the
TSX ETY 110 WS module
Connection can be made: z to an ETHWAY profile network supporting the following utilities: z common words, z z
UNI-TE messaging, to a TCP/IP profile network supporting the following utilities: z z
UNI-TE and Modbus messaging,
SNMP management.
z z
TCP direct access, access to the Web-user pages HTTP server.
TSX ETY 410• and
TSX ETY PORT modules
Connection can be made: z to a TCP/IP profile network supporting the following utilities: z
UNI-TE and Modbus messaging, z z z z z z
SNMP management, input/output management (I/O Scanner),
IP address management (BOOTP/DHCP), access to the embedded Web server, common data exchange between stations (Global Data), diagnostics from Web pages.
35011050 01 July 2006
57
General points
The
TSX ETY 510• module
Connection can be made: z to a TCP/IP profile network, which is necessary when using FactoryCast and which supports the following utilities: z
UNI-TE and Modbus messaging, z
SNMP management, z z z z z z z z time synchronization (NTP), input/output management (I/O Scanner),
IP address management (BOOTP/DHCP), access to the embedded Web server, common data exchange between stations (Global Data), diagnostics from Web pages, access to the Web-user pages HTTP server, with direct TCP access.
The TSX ETY 210 module
Connection can be made: z to an ETHWAY profile network supporting the following utilities: z z common words,
UNI-TE messaging.
z to a TCP/IP profile network supporting the following utilities: z
UNI-TE and Modbus messaging, z z
SNMP management, specific to redundancy.
58
35011050 01 July 2006
General points
Details of Available Functions
At a Glance Depending on the type of ETHERNET module selected, certain functions will or will not be accessible.
Selection Guide The summary table below shows the various selections possible:
Function TSX ETY 110 TSX ETY 110 WS TSX ETY 410• /
TSX ETY PORT
Connection at 10 Mbits/s in Half/Full
Duplex in Half/Full Duplex in Half/Full
Duplex
Connection at 100 Mbits/s -
TCP/IP utility
SNMP utility:
Standard MIB
MIB Ethernet Transparent
Factory
IO Scanner Utility
Address Server utility
(BOOT/DHCP)
-
-
X
-
X
-
-
-
-
X
X in Half Duplex
X
X
X
X
X
UNI-TE messaging
Modbus messaging
ETHWAY profile
Software loading via FTP
(firmware)
X
X
X
X
X
X
X
X
-
X
X
X
-
-
-
X
X
X
TSX ETY 510• TSX ETY 210
X
X
X
X
-
X
X
X in Half/Full
Duplex in Half Duplex
X
X
X
X
-
-
-
-
-
-
in Half/Full
Duplex
X
X
X
X
X
X
Embedded HTTP server -
Global Data -
Diagnostics from Web pages
User WEB pages HTTP server
-
Redundancy
TCP direct access
Time synchronization utility
-
Legend
X
-
-
-
Available
Not available
-
-
X
X
-
-
-
-
-
X
X
X
-
-
-
X
35011050 01 July 2006
59
General points
60
35011050 01 July 2006
Facilities
6
Introduction
Subject of this chapter
What's in this
Chapter?
This chapter introduces the main points of the different facilities used by the modules.
This chapter contains the following sections:
Section
6.1
6.2
6.3
6.4
6.5
6.6
6.7
6.8
6.9
6.10
Topic
TCP/IP Messaging
IO Scanning Facility
BOOTP/DHCP Address Server Utility
SNMP Facility
Global Data Utility
Managing Faulty Devices
Time Synchronization Service
HTTP on-board server
Bandwidth Monitoring
ETHWAY Facility
Page
35011050 01 July 2006
61