3. Operation

3.3 Operation on battery power (following failure of AC-input power)

Transfer to battery power

The AC-input power is out of tolerances, LED 11 goes ON.

During operation on battery power, the buzzer beeps every ten seconds.

The equipment connected to the UPS is supplied by the battery.

11

1 2

%

%

Threshold for the low-battery warning

%

1 2

%

11

When the threshold is reached, the buzzer beeps every three seconds.

The low-battery warning threshold can be set by the user, with the “UPS

Driver” software.

There is very little remaining battery backup time. Close all applications because UPS automatic shutdown is imminent.

When the battery reaches the end of its backup time, the UPS shuts down and all the LEDs go OFF.

The equipment is no longer supplied with power.

The UPS automatically restarts when power returns.

If the UPS does not restart, check that the “automatic restart when power returns” function has not been disabled (see section 3.4 Personalisation).

34007117EN/AB - Page 19

advertisement

Key Features

  • 800VA/480W power capacity
  • Compact 1U rackmount design
  • Automatic voltage regulation (AVR) to correct voltage fluctuations
  • Battery backup for up to 13 minutes at full load
  • USB and RS232 communication ports for monitoring and control
  • Optional data-line protection to safeguard connected equipment from surges

Related manuals

Frequently Answers and Questions

How long will the Pulsar Evolution 800 Rack power my equipment during a power outage?
The battery backup time will vary depending on the load connected to the UPS. At full load, the Pulsar Evolution 800 Rack will provide approximately 6 minutes of runtime.
Can I connect my computer, monitor, and printer to the Pulsar Evolution 800 Rack?
Yes, you can connect multiple devices to the Pulsar Evolution 800 Rack as long as the total load does not exceed the UPS's capacity of 800VA/480W.
Does the Pulsar Evolution 800 Rack have surge protection?
Yes, the Pulsar Evolution 800 Rack provides surge protection for all connected devices.