7. Service
How to Clear a Jammed Metering Roll
Shut down the fan/heater and eliminate any other noise when making this check. Place a pipe wrench on the hub of the sprocket of the jammed metering roll and turn the roll. First backward, and then forward several times in an attempt to dislodge the object, and clear it through the roll. If this is not successful, have an assistant turn the metering roll, and attempt to locate the jam by sound. Once the location is determined, the roll can be reached from the inside of the dryer by opening the hinged auger cover panel in that specific section. Loosen the two (2) nuts on the bolts holding the meter roll shield (also called meter roll strike off Plate in the past) and lift the shield to access the area above and behind the meter roll. If removing all the grain from this column is necessary, lift the shield to its highest position and tighten the nuts. FROM OUTSIDE THE DRYER, manually run the Unload Auger with the MOISTURE
CONTROL switch turned OFF and the high speed potentiometer set to 000. This will allow the grain from that column alone to pass over the metering roll and into the auger emptying that column for complete access to the meter roll.
Never run the unload auger or the metering rolls with anyone inside the dryer.
PNEG-552 100 Series Dryer
43
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 5 Chapter 1 Safety
- 5 Safety Guidelines
- 6 Dryer Operation
- 6 Emergency Stop
- 7 Safety Precautions
- 8 Chapter 2 Safety Alert Decals
- 12 Chapter 3 Dryer Control Panel
- 13 Dryer Control Panel Featuring the 100 Series Control System
- 18 Special Features
- 18 Safety Circuit Shut Down Messages
- 20 Chapter 4 Error Conditions
- 22 Chapter 5 Dryer Pre-Start Checks
- 22 Inspect the Metering Rolls
- 22 Set Control Switches
- 23 Electrical Power
- 23 Control Power Switch
- 23 Power Start Button
- 23 Fuel Check
- 23 Load Auger
- 23 1 Speed Operation
- 24 Metering Roll Operation
- 24 Fan Switch
- 25 Burner Safety
- 25 Heater Test Fire
- 25 Staged Batch Check
- 26 Dryer Shut Down
- 26 Stopping Dryer Operation
- 26 Emergency Stop
- 27 Chapter 6 Dryer Start-Up
- 27 Continuous Flow Operation
- 27 Full Start-Up Check
- 27 Filling the Dryer
- 28 Staged Batch Operation
- 30 Starting the Dryer
- 31 Adjusting the Temperature
- 32 Full Heat Continuous Flow Operation
- 33 Adjusting the Moisture Control
- 34 Chapter 7 Service
- 34 Seasonal Inspection and Service
- 35 Suggested Lubricants
- 35 Lubrication Procedures
- 35 Additional Checks
- 37 Fan Propeller Removal and Installation
- 37 Threaded Bushing Holes
- 37 Clearance Holes
- 38 Fan Motor Removal and Installation
- 40 Heater Parts Removal and Installation
- 41 Metering Roll Servicing
- 42 How to Determine a Metering Roll Problem
- 43 How to Clear a Jammed Metering Roll
- 44 Chapter 8 Wiring Diagrams
- 44 100 Series Single Fan Wiring to Control Box
- 45 100 Series Front Panel External Wiring
- 46 100 Series Front Panel Internal Wiring
- 47 100 Series Lower Back Panel Wiring
- 48 100 Series External Wiring to Dryer
- 49 100 Series Upper Control Box Wiring
- 50 100 Series Main Power Wiring
- 51 Chapter 9 Schematic Diagram
- 51 100 Series Control Schematic
- 54 100 Series 220 Volt 1 Phase Power Schematic
- 55 100 Series 220VAC 3 Phase Power Schematic
- 56 100 Series 440VAC 3 Phase Power Schematic
- 57 Chapter 10 Troubleshooting
- 61 Chapter 11 FAQs
- 63 Chapter 12 Warranty