- No category
advertisement
▼
Scroll to page 2
of
22
Operating instructions TD-16
The following Table 7 shows the structure.
Screen display Button
MENU Press the MENU button.
Screen display
ACTUATOR Press
button until "ACTUATOR" appears.
Select actuator
Actuator output switched off.
Actuator output switched on.
Link actuator output to channel 1.
Actuator output becomes active when channel 1 is active and inactive after 5 seconds when channel 1 is switched off.
Table 7: Actuator menu
The time delay for the actuator output is as follows:
The following diagram shows the time curve of the actuator when it is linked with channel 1.
Delay Off 5 s
Channel 1
Actuator output
X
Time
Status as of 09/2012 Page 15
advertisement
Related manuals
advertisement
Table of contents
- 6 PRODUCT OVERVIEW
- 6 Scope of delivery
- 6 Device versions
- 6 Properties
- 6 General
- 6 Output data
- 6 Inputs
- 6 Outputs
- 7 SAFETY INFORMATION
- 7 Intended use
- 7 Basic safety information
- 7 Transport and storage
- 8 INSTALLATION
- 8 Hardware installation
- 8 Mains connection
- 8 Oscillating conveyor connection
- 8 Fuse protection
- 9 OPERATION
- 9 Explanation of the button and display fields
- 10 Description of the user levels
- 10 Structure tree, main menu
- 10 Structure tree, channel menus 1 and
- 11 Starting level
- 12 User level, channels
- 13 Menu description
- 13 Main menu
- 14 Sensor menu
- 15 Actuator menu
- 16 Enable menu
- 17 Ramp menu
- 17 Error display
- 17 Overtemperature
- 18 DESCRIPTION OF THE CONTROL I/OS
- 18 Operating status
- 18 Enable input
- 18 Sensor input
- 19 TECHNICAL DATA
- 20 TERMINAL ASSIGNMENTS
- 20 Power connection assignments
- 20 DIMENSIONS
- 21 MAINTENANCE AND CARE
- 21 Regular tests
- 21 Decommissioning and disposal
- 22 ACCESSORIES AND OPTIONS
- 22 The plug connectors listed below are available as accessories
- 22 The connection lines listed below are available as accessories