storage. Dyna-Glo RMC-FA150NGDGD


Add to My manuals
32 Pages

advertisement

storage. Dyna-Glo RMC-FA150NGDGD | Manualzz

Dyna-Glo Delux Operating Instructions and Parts Manual

Model RMC-FA150NGDGD

Maintenance (Continued)

2. Always keep heater clean. Clean the heater annually, or as often as needed to remove any dust or debris.

When the heater becomes dirty, wipe it down with a damp cloth.

3. Keep the inside of the heater free from foreign objects and combustibles.

4. Have the heater inspected annually by a qualified service person.

SERVICE PROCEDURES

WARNING

Never service heater while hot, operating or connected to the gas supply. Severe burns or electrical shock may occur.

REMOVING PROTECTIVE COVER

1. Remove base lower at the bottom of the heater.

2. Remove fan guard.

Base

Fan Guard

Base Lower

Figure 4 – Protective Cover Removal

FAN

IMPORTANT: Always remove the fan from the motor shaft before removing the motor assembly from the heater.

This will help prevent damage to the fan.

1. Remove base lower.

2. Remove fan guard.

3. Remove base.

4. Disconnect lead wires attached to the motor.

5. Remove motor assembly.

6. Loosen fan setscrew using a 1/8” hex wrench, and remove fan.

7. Using a soft cloth moistened with kerosene or a cleaning solvent, carefully clean the fan blades making sure not to bend them.

8. Dry fan with clean cloth.

9. Assemble fan on motor shaft and tighten hex nuts firmly (be careful not to overtighten).

10. Reconnect lead wires as shown in the Wiring Diagram (Figure 6).

11. Reassemble base, fan guard and base lower.

Washer

Hex Nut

Fan

Motor

Figure 5 – Fan Motor Shaft, Hex Nut

Location

IGNITOR

The only maintenance necessary for the ignitor is to be sure that the gap between the electrodes is kept between

.10” and .15”. The ignitor is accessible through the combustion chamber.

Storage

CAUTION

Always disconnect heater from gas

supply.

1. Replace the plastic caps over the fittings they were installed when you originally unpacked your heater.

2. store the heater in a safe, clean and dry location.

3. When removing the heater from storage, always check inside of the heater for any foreign objects left by spiders or small animals. Keep the inside of the heater clean from foreign objects and combustibles.