Spirit II User’s Manual Section 6: Maintenance &Troubleshooting
General Troubleshooting
The following contains general troubleshooting guidelines for the Spirit system. Please contact KALIBURN technical support for any issues not covered in this section. Before any tests are performed, make sure that all system fuses are good; remove top cover of power supply to check these fuses.
Problem
Power supply indicator
(white light) will not illuminate
Power Supply will not energize after choosing ON and then SELECT on the
MGC.
Power supply will not stay on after choosing ON and then
SELECT on the MGC.
Possible Cause
1. Primary disconnect fuse blown.
2. Internal power supply fuse is blown (F1A, F1B).
3. Power supply indicator light is burned out or the associated wiring is bad.
4. Control Transformer or associated wiring bad.
1. ISC door open.
2. Low coolant level.
3. Fuse is blown (F1-F6).
4. Faulty OFF Button or associated wiring.
5. Off Relay faulty.
1. Faulty DSP board.
2. Off Relay faulty.
No arc at the torch
The arc will not transfer to the workpiece
1. Incorrect torch consumables installed.
2. Incorrect gas pressure settings.
3. Pilot arc transistor (PAT) is not operating properly.
Check the PAT LED (D43) on the DSP microprocessor board.
4. Damaged or loose torch lead connections.
5. Shorted torch or torch leads. Check the continuity between the Electrode lead and the Nozzle lead to make sure they are not shorted.
6. Open torch or torch leads. Check the continuity from the Electrode lead to the torch electrode and the Nozzle lead to the large brass body of the torch.
1. Loose work ground connection.
2. Pierce height too high.
3. Incorrect, damaged, or worn consumables.
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
6-9
Section 6: Maintenance &Troubleshooting Spirit II User’s Manual
Problem
Primary power has been applied to the system, but the manual gas console screen is blank
The manual gas console screen is on, but the screen doesn't work
Gas pressures will not adjust properly
Low pressure error
Pressure error during cut
Liquid or torch coolant leaking from drain hole in torch handle.
Possible Cause
1. Check power/communications CAN cable connection on back of manual gas console.
2. Check for blown DIN rail fuse.
3. Check for 120v on pins of power/communications
CAN cable at back of the manual gas console.
1. Cycle primary power to the Spirit system.
2. Check the connection of the ribbon cable that connects the keypad to the DSP PCB in the manual gas console.
1. Wrong consumables installed in torch.
2. Loose pressure transducer cable on PC board in the MGC.
3. Check connectors on the MGC valve associated with the malfunction.
1. Supply gas pressure(s) less than 120 psi.
1. Supply gas pressure(s) fluctuating during cut.
Infrequent dripping from the drain hole may be condensation; no action is required.
Noticeable flow from the drain hole indicates a problem with the torch leads and/or connections.
1. Check for damaged or loose torch lead connections within the torch handle.
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
6-10
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 2 Revision History
- 3 Table of Contents
- 6 Limited Warranty
- 6 Returned Goods Procedure
- 6 Electromagnetic Compatibility (EMC)
- 7 General Precautions
- 11 Safety Standards Booklet Index
- 7 Ultraviolet Radiation Protection
- 7 Noise Protection
- 8 Toxic Fume Prevention
- 8 Electric Shock Prevention
- 9 Fire Prevention
- 9 Explosion Prevention
- 10 Health Support Equipment
- 13 System Description
- 14 System Components
- 15 Power Supply Specifications
- 16 Torch Coolant Specifications
- 17 Manual Gas Console (MGC) Specifications
- 18 Gas Supply Requirements
- 19 Impulse Start Console (ISC) Specifications
- 20 Torch and 2-Gang Manifold Specifications
- 21 5-Gang Manifold Specifications
- 22 Airborne Noise Emissions
- 23 Initial Inspection
- 23 Component Placement
- 24 System Interconnection
- 27 Power Supply Primary Power Connections
- 29 Power Supply Output Connections
- 31 ISC Control Cable and ISC Ground Connections
- 31 Cooling System Connections
- 33 Torch Leads to Impulse Start Console Connections
- 35 Torch Leads to Torch Base Connections
- 36 Torch Gas Connections
- 39 Gas Supply Connections
- 40 CAN Communication Connections
- 41 CNC Machine Interface Connections
- 42 Filling the Cooling System
- 43 Operating the Manual Gas Console (MGC)
- 44 Setting up to Cut
- 45 Setting up to Mark (Overrides Cut)
- 45 Verifying Input Gas Pressures
- 46 Making a Cut or Mark
- 47 Piercing Thick Materials
- 47 Moving Pierces and Edge Starts
- 48 Cut Quality
- 49 Checking Errors
- 49 Checking the Version and Serial Number
- 50 Changing the Language
- 50 Adjusting the Screen Contrast
- 51 Installing / Removing the Torch Head
- 52 Installing / Replacing Consumables
- 53 Maximizing Consumable Life
- 54 Inspecting for Damage
- 55 Selecting Consumables
- 55 Mild Steel Copper Electrode
- 56 Mild Steel Silver Electrode
- 57 Stainless Steel - H17 Plasma Copper Electrode
- 58 Stainless Steel - Air or Nitrogen Plasma Copper Electrode
- 59 Stainless Steel - Air or Nitrogen Plasma Silver Electrode
- 60 Aluminum Copper Electrode
- 61 Aluminum Silver Electrode
- 62 Cutting Charts
- 63 Mild Steel - 30 Amps - Oxygen Plasma / Oxygen Shield Copper Electrode
- 64 Mild Steel - 50 amps - Oxygen Plasma / Oxygen or Air Shield Copper Electrode
- 65 Mild Steel - 70 Amps - Oxygen Plasma / Air Shield Copper Electrode
- 66 Mild Steel - 100 Amps - Oxygen Plasma / Air Shield Copper Electrode
- 67 Mild Steel - 150 Amps - Oxygen Plasma / Air Shield Copper Electrode
- 68 Stainless Steel - 30 Amps - Air Plasma / Air Shield Copper Electrode
- 69 Stainless Steel - 50 Amps - Air Plasma / Nitrogen Shield Copper Electrode
- 70 Stainless Steel - 70 Amps - H17 Plasma / Nitrogen Shield Copper Electrode
- 71 Stainless Steel - 70 Amps - Air Plasma / Nitrogen Shield Copper Electrode
- 72 Stainless Steel - 100 Amps - H17 Plasma / Nitrogen Shield Copper Electrode
- 73 Stainless Steel - 100 Amps - Air Plasma / Nitrogen Shield Copper Electrode
- 74 Stainless Steel - 150 Amps - H17 Plasma / Nitrogen Shield Copper Electrode
- 75 Stainless Steel - 150 Amps - Air Plasma / Nitrogen Shield Copper Electrode
- 76 Aluminum - 30 Amps - Air Plasma / Nitrogen Shield Copper Electrode
- 77 Aluminum - 50 Amps - Air Plasma / Nitrogen Shield Copper Electrode
- 78 Aluminum - 70 Amps - Air Plasma / Nitrogen Shield Copper Electrode
- 79 Aluminum - 100 Amps - Air Plasma / Nitrogen Shield Copper Electrode
- 80 Aluminum - 150 Amps - Air Plasma / Nitrogen Shield Copper Electrode
- 81 Mild Steel - 100 Amps - Oxygen Plasma / Air Shield Silver Electrode
- 82 Mild Steel - 150 Amps - Oxygen Plasma / Air Shield Silver Electrode
- 83 Stainless Steel - 100 Amps - Air Plasma / Nitrogen Shield Silver Electrode
- 84 Stainless Steel - 150 Amps - Air Plasma / Nitrogen Shield Silver Electrode
- 85 Aluminum - 100 Amps - Air Plasma / Nitrogen Shield Silver Electrode
- 86 Aluminum - 150 Amps - Air Plasma / Nitrogen Shield Silver Electrode
- 87 Routine Maintenance
- 87 Power Supply
- 88 Manual Gas Console (MGC)
- 88 Torch, Torch Leads, and Gas Hoses
- 89 Impulse Start Console (ISC)
- 89 Work Ground
- 90 Replacing the Torch Coolant and Filter
- 91 Microprocessor (DSP) Status Indicators
- 92 Microprocessor (DSP) Sequence of Operation
- 93 Error Codes
- 95 General Troubleshooting
- 97 Chopper Test Procedure
- 101 Power Supply (BK300211 - BK300219)
- 105 Manual Gas Console (BK300600)
- 107 Impulse Start Console (BK300500)
- 108 Torch and Manifold Assemblies
- 109 Shielded Torch Leads
- 109 CAN Communication Cable and Termination Plug
- 109 Manifold Control Cables
- 110 Gas Hose Package with MGC
- 111 Coolant and Power Leads
- 111 Work Ground Lead
- 112 Oxygen Supply Gas Hose (Optional)
- 112 Nitrogen Supply Gas Hose (Optional)
- 112 Air Supply Gas Hose (Optional)
- 112 H17 Supply Gas Hose (Optional)
- 113 “CII” Cable (for Optional External Inova)
- 114 “FII” Cable (for Optional Internal Inova)
- 115 “JII” Cable (for Optional Internal Inova)
- 116 PCB Assemblies – Component Reference Locations
- 116 Power Supply, Microprocessor DSP (BK300101) – Quadrant 1
- 117 Power Supply, Microprocessor DSP (BK300101) – Quadrant 2
- 118 Power Supply, Microprocessor DSP (BK300101) – Quadrant 3
- 119 Power Supply, Microprocessor DSP (BK300101) – Quadrant 4
- 120 Power Supply, Output (BK300108)
- 121 Power Supply, A.C. Detect (BK300112)
- 122 Gas Supply, Microprocessor DSP (BK300301) – Quadrant 1
- 123 Gas Supply, Microprocessor DSP (BK300301) – Quadrant 2
- 124 Gas Supply, Microprocessor DSP (BK300301) – Quadrant 3
- 125 Gas Supply, Microprocessor DSP (BK300301) – Quadrant 4
- 126 Chopper, Gate Driver (BK300106)
- 127 Overview
- 127 Plug Identification
- 127 Unique Interconnect Cables
- 128 Grounding
- 129 Parts List
- 129 Location in Spirit II 150 & 275
- 131 Location in Spirit II 400
- 133 Background
- 133 Installation and Use
- 134 Assessment of Area
- 134 Methods of Reducing Emissions
- 134 Mains Supply
- 134 Maintenance of the Plasma Cutting Equipment
- 134 Plasma Cutting Cables
- 135 Equipotential Bonding
- 135 Earthing of the Workpiece
- 135 Screening and Shielding