1.13 Information menu
Press UP button to enter Information Menu
Configuration
Maximum
Minimum
Alarm1
Sensor type
ºC or ºF
Hysteresis
Delay
Setpoint2
Memory of maximum
Memory of minimum
“On / Off”
“Max” / “Min”
Setpoint
User’s Manual S40-T
Counts
Seconds
Second setpoint
1.13.1 Information menu
Configuration (Conf) - Information on the configured input sensor and the degrees selected.
Maximum (MAX) - Value of the maximum display.
Minimum (MIn) - Value of the minimum display.
AlarmX (ALX) - Configuration of alarm X. The sequence of information shows if the alarm is being managed (“On/Off”), the alarm type (“Max/Min”), the setpoint, the hysteresis value, the activation delay and the value of setpoint2 (“Off” or the setpoint2 value).
OptionX (OptX) - Type of module installed. If there is no module shows “nonE”.
1.14 Accessing the instrument
You may need to access the inside of the instrument to insert additional modules. Use a flat screwdriver to unlock the upper clips marked with “A”. Then unlock the lower clips marked with “B” and move out the front filter. Let the inside of the instrument slide out of the housing.
To reinsert the instrument make sure that all modules are correctly connected to the pins on the display module. Place all the set into the housing, assuring that the modules correctly fit into the internal guiding slides of the housing. Once introduced, place again the front filter by clipping first the upper clips “A” and then the lower clips “B”.
Option1
Option2
See menu for Alarm1
Option installed
Option installed
A
B
Risk of electric shock. Removing the front cover will grant access to the internal circuits. Disconnect the input signal to prevent electric shock to the operator.
Operation must be performed by qualified personnel only.
FEMA ELECTRÓNICA - Page 10
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 2 1. Meter S40-T
- 2 1.1 Order reference
- 3 1.2 Front View
- 3 1.3 Rear View
- 3 1.4 Power Connections
- 3 1.5 Signal connections - Pt100 / RTD
- 3 1.6 Signal connections - Thermocouples
- 4 1.7 Technical data
- 4 1.7 Technical data (cont.)
- 5 1.8 Mechanical dimensions (mm)
- 6 1.9 Operating the menus
- 6 1.10 Configuration menu
- 7 1.10 Configuration menu (cont.)
- 8 1.10.1 Input menu
- 8 1.10.2 Temperature configuration
- 8 1.10.3 Alarms
- 8 1.10.4 Display
- 8 1.10.5 Tools
- 9 1.10.6 Menu OptX - Options
- 9 1.11 Default factory configuration
- 9 1.12 Messages and errors
- 10 1.13 Information menu
- 10 1.13.1 Information menu
- 10 1.14 Accessing the instrument
- 11 1.15Warranty
- 11 1.16 Installation precautions
- 11 1.17 CE declaration of conformity
- 12 2. Output and control modules
- 12 2.1 Module R
- 12 2.2 Module AO
- 13 2.3 Modules R2, R
- 14 3. More options and accessories
- 14 3.1 Option G