Version 2.7 Page 11 of 23 SMT361 SMT361A User Manual
Version control
Revision numbers for both the boot code and FPGA firmware are stored in the Flash
ROM during programming as zero-terminated ASCII strings.
The SMT6001 utility is to be used to know the version of the boot code and the
FPGA.
Reprogramming the firmware and boot code
The reprogramming is made using the SMT6001 utility. It comes with the latest firmware and boot code for the module and with a complete documentation on how to reprogram a module. It requires only the correct set-up for code composer (see code composer section).
To confirm that the programming has been successful you should use the Sundance
Server to reset the board and execute the confidence test using SMTBoardInfo.
Interrupts
See general firmware description
Communication ports
The SMT361 provides 4 ComPorts. They are ComPorts 0, 1, 3 and 4.
ComPorts 2 and 5 are interconnected on the module to allow a bypass to the next module.
See general firmware description