Module Configuration
Overview
This chapter describes the configuration and use of the MKE-3901, MKA-3901, and
MGI-3903 modules in the IconMaster system.
The following topics are covered:
Operator, All, and Setup Parameter Lists
This chapter presupposes that you have a working knowledge of NEO card-edge configuration and have used it with other NEO modules. If not, please refer to the NEO
FR-3901, FR-3903, and FR-3923 Mounting Frames Installation and Operation Manual and familiarize yourself with card-edge operation before you continue the configuration process.
Navigating the MKE-3901 Operator and All Lists
To navigate, and then view or change a parameter from the Operator and All Lists, follow these steps:
1
Open the front panel of the NEO frame.
2
Press any card-edge control to turn on the VFD screen.
The message MKE3901 appears. If a previous user has left the display at a different parameter name, repeatedly press the Escape button until the message MKE3901 appears.
After several seconds of inactivity, a scrolling message will appear, describing the purpose of the currently selected parameter.
3
Push the Enter button.
The name of the first parameter option in the list appears.
4
Push the Enter button again to access the options for the parameter displayed on the VFD screen.
OR
Press the Nav+/Nav- switch down repeatedly to view other parameters, and then press
Enter to access an item’s parameter options.
5
Press the Nav+/Nav- switch up or down to scroll through the different selectable parameter options, and then press Enter to select the value you want.
53
54
Chapter 3
Module Configuration
OR
Press the Nav+/Nav- switch up or down to adjust the numeric parameter value, and then press Enter.
6
Close the front panel of the frame to ensure the cooling system continues to operate properly.
Operator, All, and Setup Parameter Lists
The MKE-3901 displays its parameters in an Operator List, All List, and Tree View. These parameters are visible at the card-edge of the module and in CCS software.
These lists include the following parameters:
Operator and
All Lists
Table 3-1 MKE-3901 Operator and All Lists
Card-Edge ID Parameter Name
Unit_Name Unit Name
SW_Version Software Version
IP_Address
SubnetMask
Gateway
OperStd
Lite_Mode
AutoHold
Items in gray are in the All List only.
IP address
Subnet Mask
Gateway
Operation Standard
Lite Mode
Automation Hold
Function
Displays the name of the device
Displays the version number of the currently installed software
Changes the address of the
IconMaster module on the network.
User Range
String (MKE3901)
String (none)
String (192.168.100.252)
Changing the IP address releases the IconMaster from panel control. To regain control of the panel, enter the new IP address into the panel's list of “reachable” machines
Changes the range of IP addresses that can communicate with this device
Changes the network routing for the device
String (255.255.0.0)
String (0.0.0.0)
String (None)
String (No) Indicates whether the device is operating as a lite version of
IconMaster; some features are disabled in this mode
Stops the IconMaster from responding to Automation commands
On
Off
IconMaster
Installation and Configuration Manual
55
Key1_OnNext
Key2_OnNext
Key3_OnNext
Key4_OnNext
Key5_OnNext
Key6_OnNext
Key1_OnAir
Key2_OnAir
Key3_OnAir
Key4_OnAir
Key5_OnAir
Key6_OnAir
Table 3-1 MKE-3901 Operator and All Lists (Continued)
Card-Edge ID Parameter Name
PgmBypass Program Bypass
PST_Src
PGM_Src
BKGD
TAKE
PREROLL
TransSpeed
TransShape
ATransShape
BreakawayMode
PST Source Selection
PGM Source Selection
BKGD
TAKE
PREROLL
Transition Speed
Transition Shape
Audio Trans Shape
Breakaway Mode
Function
When activated, bypasses the program bus
Selects the source for preset bus String (None)
Selects the source for the program bus
String (None)
Activates the BKGD function, so that a background transition from the PST bus to the PGM bus will occur when you select Take or
Preroll
On
Off
Triggers a take, causing the next transition to start immediately
Triggers a preroll, activating a different piece of equipment to perform an event
On
Off
On
Off
Sets the transition rate
Selects the type of transition that will be performed
Selects the type of audio transition that will be performed
When off, the audio and video transition at the same time; when this parameter is set to one of the other options, only that option will transition
Triggers the specified key on the next transition
User Range
On
Off
String (None)
Cut-Fade
Fade-Cut
Fade-Fade
X-Fade
Cut-Fade
Fade-Cut
Fade-Fade
X-Fade
Off
Video
Audio
On
Off
Key1 On Next Trans
Key2 On Next Trans
Key3 On Next Trans
Key4 On Next Trans
Key5 On Next Trans
Key6 On Next Trans
Key1 On Air
Key2 On Air
Key3 On Air
Key4 On Air
Key5 On Air
Key6 On Air
Triggers the specified key to air immediately
On
Off
56
Chapter 3
Module Configuration
Table 3-1 MKE-3901 Operator and All Lists (Continued)
Card-Edge ID
AO1_OnNext
AO2_OnNext
AO1_OnAir
AO2_OnAir
K3_LogoSel
K4_LogoSel
K5_LogoSel
K6_LogoSel
FTB
Parameter Name
AO1 On Next Trans
AO2 On Next Trans
AO1 On Air
AO2 On Air
Assign Logo to Key3
Assign Logo to Key4
Assign Logo to Key5
Assign Logo to Key6
Fade To Black
Function
Triggers the specified audio over on the next transition
Triggers the specified audio over to air immediately
Selects the logo for the specified key
Causes the video program outputs to immediately fade to black
SIL
S_PST_Present
S_PST_NonSync
S_PGM_Present
S_PGM_NonSync
S_K1_Present
S_K1_NonSync
S_K2_Present
S_K2_NonSync
S_REF_Present
S_HW_Error
S_COMM_Error
S_Warning_Msg
BreakawayStatus
Silence
PST Present Status
PST NonSync Status
PGM Present Status
PGM NonSync Status
Key1 Present Status
Key1 NonSync Status
Key2 Present Status
Key2 NonSync Status
Reference Present
Hardware Error
Communication Error
System Warning Msg
Breakaway Status
User Range
On
Off
On
Off
String (None)
Causes the audio program outputs to immediately fade to silence
Indicates whether there is data on the Preset bus
Indicates whether the Preset bus is synced correctly
Indicates whether there is data on the Program bus
Indicates whether the Program bus is synced correctly
Indicates whether the specified key has been assigned
Indicates whether the specified key is synced correctly
Indicates whether the specified key has been assigned
Indicates whether the specified key is synced correctly
Indicates whether reference signal is present
Indicates a detected hardware malfunction
Indicates a detected communication error
Indicates that the system has triggered a warning message
Displays whether breakaway status is active
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
On
Off
On
Off
Yes
No
Yes
No
IconMaster
Installation and Configuration Manual
57
Setup
Parameters
You can modify the SETUP parameters to configure the card-edge controls for your personal needs. The structure of the Setup menu is as follows (default settings are indicated by asterisks):
Nav Mode (Navigation Mode)
(Options: Oper List*, All List, Tree View)
SelPar Adj Mode (Selectable Parameter Adjust Mode)
(Options: Immediate, Delayed*)
Brws Mode (Browse Mode)
(Options: Param List, Param+Val*)
Scrl Mode (Scroll Mode)
(Options: Wrap*, Don’t Wrap)
Disp Inten (Display Intensity)
(Options: 100%, 50%*, 25%, 12%)
Param Desc (Parameter Description)
(Options: Disabled, Enabled*)
About [RO]
See your NEO FR-3901, FR-3903, and FR-3923 Mounting Frames Installation and Operation
Manual for more information on Setup items.
LEDs and Module Indicators
MKE-3901 LEDs and Module Indicators
Each MKE-3901 module has 8 card-edge LEDs and 4 module indicators. The module indicators include Major Alarm and Minor Alarm. These alarms are not currently in use in the IconMaster system.
58
Chapter 3
Module Configuration
Figure 3-1
illustrates the locations of the LEDs and standard module indicators on the
MKE-3901 module. The meanings of the LEDs are described in
Table 3-2
. The meanings of the module indicators are described in
.
Standard module indicators Local/Remote switch
LEDs
Escape button
Nav+/Nav- switch
(up/down)
Major alarm
Power
Minor
Enter button alarm
Module status
Card extractor
Figure 3-1 MKE-3901Card-Edge LEDs and Module Indicators
D5
D6
D7
D8
Table 3-2 MKE-3901 LED Descriptions
LED Number
D1
D2
D3
D4
LED Name
Lock
AO 1
AO 2
BCG Mix
Key 1
Key 2
Key/MGI
FTB/FTS
Color
Green
Green
Green
Green
Green
Green
Green
Green
Meaning (When Lit)
The module is locked to the reference signal.
The Audio Over 1 function is on air.
The Audio Over 2 function is on air.
A video background transition is in progress.
Key 1 is on air.
Key 2 is on air.
Key 3, 4, 5, or 6 is on air.
Video is black or audio is silent.
Table 3-3 MKE-3901 Module Indicator Descriptions
Module
Indicator
Major Alarm
Color
Red
Meaning (When Lit)
(Not currently active)
IconMaster
Installation and Configuration Manual
59
Table 3-3 MKE-3901 Module Indicator Descriptions (Continued)
Module
Indicator
Minor Alarm
Power
Module Status
Color
Yellow
Green
Green
Meaning (When Lit)
(Not currently active)
The module is receiving power.
The module is configured, loaded, and operational.
MGI-3903 LEDs and Module Indicators
The IconMaster logo inserter has 2 card-edge LEDs and 4 standard module indicators.
CAUTION
Never remove the compact flash card when the Compact Flash Card
Active LED is on or flashing. Doing so may corrupt the files on the card.
The module generates visible alarm signals to alert users of failures or impending failures.
These alarm signals can be found in the following locations:
As red or yellow LEDs on the front module card-edge
As red or yellow LEDs on the 3901AIC Alarm Interconnect Module or the 3901RES-E
Resource Module (visible via light pipes through the NEO frame’s front panel)
As part of a list of activated alarms found in the MGI-3903 Setup menu
Figure 3-2
on page 59 illustrates the locations of the LEDs and standard module indicators on the MKE-3901 module. The meanings of the LEDs are described in
on page 60. The meanings of the module indicators are described in
Standard module indicators Local/Remote switch
LEDs
Ejector
Compact flash card socket
Escape button
Nav+/Nav- switch
(up/down)
Major alarm
Power
Enter button
Minor alarm
Module status
Card extractor
Figure 3-2 MGI-3903 Card-Edge LEDs and Module Indicators
60
Chapter 3
Module Configuration
Table 3-4 MGI-3903 LED Descriptions
LED Indicator
ACT
(Compact flash card active)
MTD
(Compact flash card mounted)
Color Meaning (When Lit)
Amber The flash card is actively being written to or read from. To prevent corruption of the data, do not remove the flash card when this LED is lit.
Green The flash card has been opened and the files recognized by the MGI-3903
Note: A frame’s active resource module provides additional LEDs that indicate conditions not included in these module-specific LEDs. See the card-edge of the resource module for these LEDs.
Table 3-5 MGI-3903 Module Indicator Descriptions
LED Indicator
Major Alarm
Minor Alarm
Power
Module Status
Color
Red
Meaning (When Lit)
There is a problem with the card that will stop the product functioning correctly
Amber There is a minor problem with the card that may reduce the functionality of the product
Green The card is receiving power
Green The module is configured, loaded and operating correctly