advertisement
InStaLLatIOn
Maintenance
15. maintenance
WARNING Electrocution
Before any work on the appliance, disconnect all poles from the power supply.
alternative connection options
47 b03
Draining the appliance
You can drain the appliance for maintenance work or to protect it from frost.
CAUTION Scalding
Hot water may escape when draining the appliance.
b04 b02
30 b04 b04 f Store the dismantled appliance in a room free from the risk of frost, as water residues remaining inside the appliance can freeze and cause damage.
16. Specification
16.1 Dimensions and connections
225
140
≤ 20 105 b04 b02 Entry electrical cables I b03 Entry electrical cables II b04 Entry electrical cables III
16.2 wiring diagram
3/PE ~ 400 V
165 b04
1 3 4 2
2
I II
1 I
L1`
II
L2` L3`
2 3/4 b02
30
1
U
F
L
L
L
c06
100 c01
35
114 b02 Entry electrical cables I c01 Cold water inlet c06 DHW outlet
Male thread
Male thread
G 1/2 A
G 1/2 A
3
4
1 Power PCB
2 Bare wire heating system
3 High limit safety cut-out
4 Safety switch
Priority control with load shedding relay (lr 1-a)
See also chapter "Appliance description / Accessories".
38 |DHE SLi www.stiebel-eltron.com
299680_DHE_18-27_SLi_de_en_fr_nl_pl_cs_bg_ru.indb 38 05.03.2013 08:38:31
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 2 General information
- 2 Safety instructions
- 3 Other symbols in this documentation
- 3 Units of measurement
- 3 Safety
- 3 Intended use
- 3 General safety instructions
- 3 CE designation
- 3 Test symbols
- 4 Appliance description
- 4 Settings and displays
- 4 User interface on the appliance
- 5 Temperature setting
- 5 Economy monitor selection
- 6 Appliance settings
- 7 Cleaning, care and maintenance
- 7 Troubleshooting
- 8 Safety
- 8 General safety instructions
- 8 Instructions, standards and regulations
- 8 Appliance description
- 8 Standard delivery
- 8 Accessories
- 9 Preparations
- 9 Installation site
- 9 Factory settings
- 10 Installation
- 12 10.1 Completing the installation
- 12 10.2 Alternative installation methods
- 15 Commissioning
- 15 11.1 Commissioning
- 15 11.2 Recommissioning
- 15 Service mode
- 16 Shutting down
- 16 Troubleshooting
- 18 Maintenance
- 18 Specification
- 18 16.1 Dimensions and connections
- 18 16.2 Wiring diagram
- 19 16.3 Mixed water volume / outlet volume
- 19 16.4 Application areas
- 19 16.5 Pressure drop
- 19 16.6 Fault conditions
- 20 16.7 Data table