10. Software and Firmware Loading Instructions
Introduction
New and improved software will appear from time to time on our web site at www.logicube.com. It is possible to update both the operating software and the firmware in the field by a user.
NOTE: Logicube provides a CD-ROM that contains a backup copy of the Dossier software. This software is already loaded on your unit.
Software version 2.0.0RC01-105 and is not compatible with the MPFS. In order for you to use the
Forensic Dossier with MPFS you must revert to software version 1.21RC50 and firmware version 9.0.
Instructions on how to do this can be found below.
NOTE:
See the “MPFS (Maassive Portable
Forensic Storage) Notes” below.
Loading New Software and Firmware
The new software and firmware have to be placed on the root directory of the System CF card.
1. Disconnect the AC Adapter from the
Dossier, and hold down the Start/Stop button while re-connecting the AC Adapter back on.
2. A hidden menu will appear with the following choices:
Continue
– This boots the unit to the Main screen.
Upgrade FPGA Firmware
– replaces the current firmware with the newest firmware file (no longer used).
Engage System CF card
– engages the CF card and makes it accessible through the USB connection.
3.
Use the Back button to scroll to “Engage
System CF card” and press the Set button to confirm your selection.
4. The Dossier will apply power to the
System CF card. Attach a mini USB cable
Forensic Dossier User Manual 104
SOFTWARE LOADING INSTRUCTIONS
(included) to a Windows based PC and to the Dossier.
5. Windows will detect the System CF card and automatically assign a drive letter to the System CF card.
6. Extract the contents of the downloaded zip file to the root of the System CF card and overwrite any existing file(s) on the
System CF card.
7. Press the BACK button to go back to the hidden menu.
8. Disconnect the AC adapter from the
Dossier. Wait at least 10 seconds then reconnect the AC adapter to apply power to the Dossier.
9. The Dossier will load the new BIOS,
Software, and Firmware during the boot process.
10. Check the version and date of the new software and firmware by tapping the
“About” icon at the Main Screen.
MPFS (Massive Portable Forensic Storage) Notes:
If you upgraded to this software release and want to use your Dossier with the MPFS, simply follow these instructions:
A. Disconnect the AC Adapter from the
Dossier, and hold down the Start/Stop button while re-connecting the AC Adapter back on.
B. A hidden menu will appear with the following choices:
Continue
– This bypasses the upgrade and boots the unit into the main screen.
Upgrade FPGA Firmware
– Replaces the current firmware with the newest firmware file (no longer used).
Engage System CF card
– Engages the CF card and makes it accessible through the USB connection.
C.
Use the Back button to scroll to “Engage
System CF card” and press the Set button to confirm your selection.
D. The Dossier will apply power to the
System CF card. Attach a mini USB cable
(included) to a Windows based PC and to the Dossier.
Forensic Dossier User’s Manual
105
SOFTWARE AND FIRMWARE LOADING INSTRUCTIONS
E. Windows will detect the System CF card and automatically assign a drive letter to the System CF card.
F. Delete the file ngfv2.bin.
G. Press the BACK button to go back to the hidden menu.
H. Disconnect the AC adapter from the
Dossier. Wait at least 10 seconds, then reconnect the AC adapter to apply power to the Dossier.
I. The Dossier will revert back to software version 1.21RC50 and firmware version
9.0. Check the version and date of the software and firmware by tapping the
“About” icon at the Main screen.
NOTE: If you want to use the Dossier with the Dossier tray and any new feature featured in software releases
2.0.0RC01-105 and up you must follow steps A through E above then extract the ngfv2.bin from the downloaded zip file to the root of the CF card, then follow steps G and H.
The newer version of the software will load during the boot process. Check the version and date of the software and firmware by tapping the "About" icon at the Main screen.
.
Forensic Dossier
User’s Manual
106
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 9 1. INTRODUCTION TO THE FORENSIC DOSSIER
- 16 2. GETTING STARTED
- 17 Opening the Logicube Dossier
- 18 Connecting a PATA Drive
- 20 Connecting a Serial ATA (SATA) Drive
- 21 Connecting other types of drives
- 22 Calibrating the Touch Screen
- 26 3. DRIVE CAPTURE MODES AND SETTINGS
- 26 Drives
- 27 Settings
- 27 About
- 33 Verify Disk or File
- 33 File Size
- 45 4. OTHER MODES
- 45 Procedure
- 50 Contrast
- 50 Save Settings
- 50 Factory Settings
- 52 Eject Page
- 52 Print Report
- 52 Auto Print (After Capture)
- 54 High Security
- 54 Maximum Security
- 56 Disabled
- 57 Performing SAS and SCSI Adapter Updates
- 63 5. CAPTURING RAID CONFIGURATIONS
- 64 Drive Capture and DD Capture
- 64 Verify
- 64 Calculate HASH and Keyword Search
- 65 6. USB AND FIREWIRE PORTS
- 69 How to set up and use the USB/FireWire cloning software
- 70 Selectable Capture Modes & Options
- 73 Cloning a Mac using FireWire and the Cloning Software
- 73 Additional Notes
- 75 7. KEYWORD SEARCHING
- 76 Procedure
- 82 8. OPTIONAL PERIPHERALS
- 82 (MPFS™)
- 101 9. INTERNAL FLASH MEMORY
- 104 10. SOFTWARE AND FIRMWARE LOADING INSTRUCTIONS
- 107 11. REFERENCE
- 107 Options
- 108 Erase process with Security Erase
- 108 Erase process using non Security Erase drives
- 108 HASH + V
- 113 Erase Process
- 113 Write a unique signature to the destination drive
- 114 Information Format
- 119 12. FREQUENTLY ASKED DOSSIER QUESTIONS AND ANSWERS
- 121 13. INDEX