7.10.9 Set the Measurement Condition

For the debugger, the following measurement conditions can be specified.

• Measure the execution time between the events.

• Measure a period at which intervals events occur.

• Measure the time at which events are established.

By specifying a function name, it is possible to measure the execution time of that function. Up to four measurement intervals can be specified. To specify measurement intervals, click any line (MP1-MP4) in the Measurement Point group of the Interval Time Measure Window. This opens a dialog box for specifying measurement conditions.

7.10.9.1 Measure the execution time between the events

1. Set the measurement events (measurement start event and measurement end event).

2. Specify the following in the Measurement Condition Designation dialog.

166

7.10.9.2 Measure the event occurrence cycle

1. Set the measurement event (measurement start event only).

2. Specify the following in the Measurement Condition Designation dialog.

7 Windows/Dialogs

7.10.9.3 Measure the event establishment time

1. Set the measurement event (measurement start event only).

2. Specify the following in the Measurement Condition Designation dialog.

167

7.10.9.4 Measure the execution time of the specified function (1)

Measure the execution time of the specified function.

In this mode, the function top address is automatically registered to the measurement start event, and the function end address to the measurement end address.

The measurement result contains the execution time of other function called within the specified function.

Specify the following in the Measurement Condition Designation dialog.

168

7 Windows/Dialogs

7.10.9.5 Measure the execution time of the specified function (2)

Measure the execution time of the specified function.

In this mode, the function address range is automatically registered to the measurement start event.

The measurement result does not contain the execution time of other function called within the specified function.

Specify the following in the Measurement Condition Designation dialog.

ATTENTION

When the target function calls the other functions, the first measurement finishes at the first calling the other function, and the second measurement begins at the returning to the target function from the first one.

169