4.2.3 Advanced Options

Thread Direction: Defines fastening direction (default is right hand).

Re-hit/Reject Parameters:

P revents the tightening of an already tightened fastener. If enabled, tool will stop and the rundown will be aborted, if the angle of rotation between the

Re-Hit Reference Torque and the In-Cycle Torque is less than the Re-Hit Angle Count.

NOTE: If the attempted rundown is a Re-Hit, it will not be reported or recorded.

Re-hit Reject Enable: Enables the feature.

Re-Hit Reference Torque: This torque value is the start of the angle count that determines a Re-Hit. (This value should be lower than the In Cycle Torque specified in the PSet.)

Re-Hit Angle Count: If the angle count between the Re-Hit

Reference Torque and the In Cycle Torque is less than this value, the rundown is determined to be a Re-Hit.

4.2.4 Default PSets

This will generate three generic PSets for the tool connected to the

Controller. It will automatically use the 40%, 60%, 80% of the rated maximum torque of the tool in a two-stage Torque Control Strategy

(TC). The prompt will display rated Max Torque and Max RPM of connected tool for reference.

These Psets can be modified to meet application requirements

.