Symbology Options. PSC PowerScan RF
Reklama
Reklama
Symbology Options
After enabling the desired symbology, you can use the bar code labels in this section to configure the specific options/features required for your site.
Code 39/PharmaCode 39
Code 39
Options
The Code 39 symbology has the following programmable features:
•
Check Digit
•
Start/Stop Characters
•
Code 39 Full ASCII
•
Minimum Label Length
•
Read Verification
•
QuadraLogic™ II Decoding
Check Digit
Check Digit calculates the Check Digit to verify that the Check Digit contained in the bar code label is correct. If you enable this feature, your bar codes must contain a Check Digit.
Start/Stop
Characters
Start/Stop Characters selects either Send or Don’t Send depending on your host’s interface requirement.
Code 39 Full ASCII
Code 39 Full ASCII enables or disables the ability to decode Code 39
Full ASCII labels.
Minimum Label
Length
Minimum Label Length sets the minimum label length required for the
Code 39 symbology. This feature causes the scanner to ignore small label segments, reducing the possibility that a portion of a good label is incorrectly seen as an entire label.
Read Verification
Read Verification is the number of times the scanner is required to read the bar code data before sending the label data to the host.
QuadraLogic™ II
Decoding
QuadraLogic™ II Decoding directs the scanner to decode labels with widespread problems of spots, voids, and/or non-uniform widths.
To optimize your scanner’s performance activate this option only for symbologies for which it is necessary.
There are many additional ways to configure the scanner to read and decode extremely poor labels. Contact your sales representative or service provider for other advanced QuadraLogic™ II Decoding settings.
RF Programming Manual
79
80
Configuring the Code 39
Options
Code 39 options are all applicable only to the scanner, with the exception of Check Digit Transmission, which applies only to the Base Station.
Use the special bar codes in this section to configure the Code 39 options
SET ------------------------------
Check Digit
Don’t Calculate ---------
Calculate ---------
Don’t Transmit ---------
Transmit ---------
PowerScan™ RF Scanner
RF Programming Manual
Start/ Stop
Don’t Transmit ---------
Transmit ---------
Code 39 Full ASCII
Enable ---------
Disable ---------
END ------------------------------
Transmit Scanner
Configuration to
Base Station ---------
81
82
Minimum Label
Length
Follow these steps to set Code 39 Minimum Label Length:
1.
Identify the minimum label length setting you want to make.
The selectable range is 00 to 48
1
characters.
2.
Scan the SET bar code.
3.
Scan the SET MINIMUM LABEL LENGTH bar code.
4.
Set the minimum label length by scanning the applicable digits from the bar codes on
page 83 . Return to this page and
go to step five.
If you are setting a label length less than ten, you must scan a zero digit first and then the length digit (e.g., 04, 06, 08).
NOTE
5.
Scan the END barcode.
Minimum Label Length
SET ------------------------------------------
Set Minimum Label Length ---------
END ------------------------------------------
1. For this symbology, the scanner will decode up to 48 characters, but the actual length read will vary depending upon interface type, and bar code physical size and quality. Code 39 bar codes containing one or more full ASCII characters can also limit the amount of characters that will be decoded (in these circumstances, the scanner will decode at least 24 data characters).
PowerScan™ RF Scanner
RF Programming Manual
Digits
0
1
2
8
9
6
7
3
4
5
---------
---------
---------
---------
---------
---------
---------
---------
---------
---------
83
84
Read Verification
Scan the bar codes below to set the minimum number of reads required to verify Code 39/Pharmacode 39 symbologies.
NOTE
The more times the scanner is required to read and compare the bar codes data, the longer the scanner will take to validate and transmit a label.
SET ------------------------------------------
Set to One read ---------
Set to Two reads ---------
Set to Three reads ---------
Set to Four reads ---------
END ------------------------------------------
PowerScan™ RF Scanner
QuadraLogic™ II
Decoding
Scan these bar codes to activate/deactivate the QuadraLogic™ II
Decoding feature for Code 39/PharmaCode 39 symbologies.
SET ------------------------------------------
Activate for Code 39/
PharmaCode 39 ---------
Deactivate for Code 39/
PharmaCode 39 ---------
END ------------------------------------------
PharmaCode
39 Options
Transmit Check
Digit
Start/Stop
Characters
PharmaCode 39 symbology has the following programmable features:
•
Transmit Check Digit
•
Start/Stop Characters
Transmit Check Digit selects whether the Check Digit will/won’t be transmitted to the host terminal.
Start/Stop Characters directs the scanner to either Send or Don’t Send depending on your host’s interface requirement.
In order for PharmaCode 39 labels to be read and transmitted as PharmaCode 39, the Code
39 symbology must first be enabled.
NOTE
RF Programming Manual
85
86
Configuring the
PharmaCode
39 Options
These features are specific to the Base Station ONLY
Scan the bar codes below to configure the PharmaCode 39 options for
Check Digit and Start/Stop Characters.
SET -------------------------------
Check Digit
Don’t Transmit ---------
Transmit ---------
Start/Stop
Don’t Transit ---------
Transmit ---------
END ------------------------------
Transmit Scanner
Configuration to
Base Station ---------
PowerScan™ RF Scanner
Code128 and UCC/EAN 128 Options
These Code 128 and UCC/EAN 128 features are specific to the scanner ONLY
The Code 128 and UCC/EAN 128 symbologies have the following programmable feature.
•
Minimum Label Length
•
Read Verification
Setting Minimum
Label Length
•
QuadraLogic™ II Decoding
Setting Minimum Label Length sets the minimum length required for
Code 128 and UCC/EAN symbology. This feature causes the scanner to ignore small label segments, reducing the possibility that a portion of a good label is incorrectly seen as an entire label.
Read Verification
Read Verification is the number of times the scanner is required to read the bar code data before sending the label data to the host.
QuadraLogic™ II
Decoding
QuadraLogic™ II Decoding directs the scanner to decode labels with widespread problems of spots, voids, and/or non-uniform widths.
To optimize your scanner’s performance activate this option only for symbologies for which it is necessary.
There are many additional ways to configure the scanner to read and decode extremely poor labels. Contact your sales representative or service provider for other advanced QuadraLogic™ II Decoding settings.
RF Programming Manual
87
88
Configuring the Code 128/ and UCC/EAN
128 Options
Minimum Label
Length
Use the bar codes in this section to configure the Code 128 and UCC/
EAN 128 options.
Follow these steps to set Code 128 and UCC/EAN 128 Minimum Label
Length.
1.
Identify the minimum length setting you want to make. The selectable range is 00 to 50
1
characters.
2.
Scan the SET bar code on page 88
.
3.
Scan the SET MINIMUM LABEL LENGTH bar code.
4.
Set the minimum label length by scanning the applicable digits from the bar codes on
page 89 . Return to this page and
go to step five
If you are setting a label length less than ten, you must scan a zero digit first and then the length digit (e.g., 04, 06, 08).
NOTE
5.
Scan the END bar code
Minimum Label Length
SET ------------------------------------------
Set Minimum Label Length ---------
END ------------------------------------------
1. The scanner will decode up to 50 characters, but the actual length read will vary depending upon interface type, the physical size of the bar codes, print quality and whether the bar code data consists of Code 128 code set A, set B, or set C characters. (The C128 character set C allows for more densely packed data, thus if the bar code includes all or mostly C128 set C characters, more characters can be decoded).
PowerScan™ RF Scanner
RF Programming Manual
4
5
2
3
6
7
8
9
Digits
0
1
---------
---------
---------
---------
---------
---------
---------
---------
---------
---------
89
90
Read Verification
Scan the bar codes below to set the minimum number of reads required to verify Code 128 and UCC/EAN symbologies.
NOTE
The more times the scanner is required to read and compare the bar codes data, the longer the scanner will take to validate and transmit a label.
SET ------------------------------------------
Set to One read ---------
Set to Two reads ---------
Set to Three reads ---------
Set to Four reads ---------
END ------------------------------------------
PowerScan™ RF Scanner
QuadraLogic™ II
Decoding
Scan these bar codes to activate/deactivate the QuadraLogic™ II
Decoding feature for the Code 128 and UCC/EAN 128 symbologies.
SET ------------------------------------------
Activate for C128 and
UCC/EAN 128 ---------
Deactivate for C128 and
UCC/EAN 128 ---------
END ------------------------------------------
RF Programming Manual
91
Interleaved 2 of 5 Options
The Interleaved 2 of 5 symbology has the following programmable features:
•
Check Digit
•
Label Length Format
•
Read Verification
•
QuadraLogic™ II Decoding
Check Digit
Check Digit calculates the Check Digit to verify that the Check Digit contained in the bar code label is correct. If you enable this feature, your bar codes must contain a Check Digit.
If the Check Digit is not calculated, the digit will be sent regardless of settings for transmit or don’t transmit. For example, if you choose to
Transmit Check Digit, but not calculate, the scanner sends the Check
Digit encoded in the bar code without verifying its accuracy.
Label Length
Format
Label length format permits the selection between variable length or fixed length formats. For best performance it is recomended to use the
Fixed Length settings when your application requires only one or two label lengths.
Variable Length Format
- directs the scanner to read all labels from the minimum label length to 50. Set Minimum Length as high as your application allows.
Minimum Label Length
- selects the minimum label length that the scanner will recognize. The minimum label length for this symbology must be an
even
number of characters between
02 and 50
1
.
Fixed Length Format
- directs the scanner to read only one or two label lengths.
If you select fixed length format, there are three bar code labels for programming your scanner to read either one or two fixed lengths. The labels are:
Set First Fixed Length
- instructs the scanner that the next two programming labels scanned will define the first fixed label length. This setting can be any
even
number of characters
92
1. For this symbology, the scanner will decode up to 50 characters, but the actual length read will vary depending upon the interface type, and bar code physical size and quality.
PowerScan™ RF Scanner
Set Second Fixed Length
- instructs the scanner that the next two programming labels scanned will define the second fixed label length. This setting can be any
even
number of characters between 02 and 50
1
characters.
No Second Fixed Length
- configures the scanner to recognize only the first fixed length.
Read Verification
Read Verification is the number of times the scanner is required to read the bar code data before sending the label data to the host.
QuadraLogic™ II
Decoding
QuadraLogic™ II Decoding directs the scanner to decode labels with widespread problems of spots, void, and/or non-uniform widths.
To optimize your scanner’s performance activate this option only for symbologies for which it is necessary.
There are many additional ways to configure the scanner to read and decode extremely poor labels. Contact your sales representative or service provider for other advanced QuadraLogic™ II Decoding settings.
RF Programming Manual
1. For this symbology, the scanner will decode up to 50 characters, but the actual length read will vary depending upon the interface type, and bar code physical size and quality.
93
94
Configuring the Interleaved
2 of 5 Options
I 2 of 5 options are all applicable only to the scanner, with the exception of Check Digit Transmission, which applies only to the Base Station.
Use the special bar codes in this section to configure the Interleaved
2 of 5 symbology options.
Check Digit
SET ------------------------------
Don’t Calculate ---------
Calculate ---------
Don’t Transmit ---------
Transmit ---------
END -----------------------------
Transmit Scanner
Configuration to
Base Station ---------
PowerScan™ RF Scanner
Label Length
Format
Variable Length
Format
Follow the steps below to set the Interleaved 2 of 5 label Length Format to select either the
Variable Length
or
Fixed Length Format.
Follow the steps below to set the Interleaved 2 of 5 symbology to Variable Length Format.
1.
Identify the minimum length setting you want to make. The selectable range is any
even
number from 02 to 50
1
characters.
2.
Scan the SET bar code below.
3.
Scan the ENABLE VARIABLE LENGTH FORMAT bar code.
4.
Scan the SET MINIMUM LABEL LENGTH bar code.
5.
Set the minimum label length by scanning the correct digits from
. Return to this page and go to step six.
If you are setting a label length less than ten, you must scan a zero digit first and then the length digit (e.g., 04, 06, 08).
NOTE
6.
Scan the END bar code.
Variable Length Format
SET ------------------------------------------
Enable Variable Length
Set Minimum Label
Length ---------
END ------------------------------------------
RF Programming Manual
1. For this symbology, the scanner will decode up to 50 characters, but the actual length read will vary depending upon the interface type, and bar code physical size and quality.
95
96
Fixed Length
Format
All interfaces that are shipped with the standard factory configuration are set to read variable length labels. If you switch from the variable to fixed length format, the default label lengths are 14 characters and 8 digits. All fixed length settings must be an
even
number.
Follow the steps below to set Interleaved 2 of 5 symbology to Fixed
Length Format.
1.
Identify the fixed length settings you want to make.
2.
Scan the SET bar code.
3.
Scan the ENABLE FIXED LENGTH FORMAT bar code.
4.
Scan the SET FIRST FIXED LENGTH bar code.
5.
Set the first fixed label length by scanning the digit bar codes from
(even number only). Return to this page.
If you are setting a label length less than ten, you must scan a zero digit first and then the length digit (e.g., 04, 06, 08).
NOTE
If you need to set a second fixed length, continue to step six. If you do not need to set a second fixed length skip to step nine.
6.
Scan the SET SECOND FIXED LENGTH bar code.
7.
Set the second fixed label length by scanning the applicable
.
8.
Return to this page and go to step ten.
If you are setting a label length less than ten, you must scan a zero digit first and then the length digit (e.g., 04, 06, 08).
NOTE
9.
Scan the NO SECOND FIXED LENGTH bar code.
10.
Scan the END bar code.
PowerScan™ RF Scanner
SET ------------------------------------------
Enable Fixed Length
Format ---------
Set First Fixed Length ---------
Set Second Fixed Length ---------
No Second Fixed Length ---------
END ------------------------------------------
RF Programming Manual
97
98
Digits
0
5
6
7
8
9
3
4
1
2
---------
---------
---------
---------
---------
---------
---------
---------
---------
---------
PowerScan™ RF Scanner
Read Verification
Scan the bar codes below to set the number of reads desired to verify
Interleaved 2 of 5 symbology.
NOTE
The more times the scanner is required to read and compare the bar codes data, the longer the scanner will take to validate and transmit a label.
SET ------------------------------------------
Set to One read ---------
Set to Two reads ---------
Set to Three reads ---------
Set to Four reads ---------
END ------------------------------------------
RF Programming Manual
99
QuadraLogic™ II
Decoding
Scan these bar codes to activate/deactivate the QuadraLogic™ II
Decoding feature for Interleaved 2 of 5 symbology.
SET ------------------------------------------
Activate for Interleaved
2 of 5 ---------
Deactivate for Interleaved
2 of 5 ---------
END ------------------------------------------
100
PowerScan™ RF Scanner
Codabar Options
The Codabar symbology has the following programmable features:
•
Check Digit
•
Gap Check
•
Label Length Format
•
Start/Stop Character
•
Start/Stop Match
•
Start/Stop Format
•
Read Verification
•
QuadraLogic™ II Decoding
Check Digit
Check Digit calculates the Check Digit to verify the label’s contents have been read correctly. If you enable this feature, your labels must include a Check Digit. You may also choose to transmit or not transmit the Check Digit.
If the Check Digit is not calculated, the digit will be sent regardless of settings for transmit or don’t transmit. For example, if you choose to
Transmit Check Digit, but not calculate, the scanner sends the Check
Digit encoded in the label without verifying its accuracy.
Gap Check
Disabling Gap Check allows the scanner to combine two label halves printed in close proximity to each other that may have been printed at different times and perhaps different locations.
Label Length
Format
Label length format permits the selection between variable length or fixed length formats. For best performance it is recomended to use the
Fixed Length settings when your application requires only one or two label lengths.
Variable Length Format
- directs the scanner to read all labels from minimum label length to 50. Set Minimum Length as high as your application allows.
Minimum Label Length
- selects the minimum label length that the scanner will recognize. The minimum label length for this symbology must be between 03 and 50
1
.
Fixed length Format
- directs the scanner to read only one or two label lengths.
1. For this symbology, the scanner will decode up to 50 characters, but the actual length read will vary depending upon the interface type, and bar code physical size and quality.
RF Programming Manual
101
If you select fixed length format, there are three bar code labels for programming your scanner to read either one or two fixed lengths. The labels are:
Set First Fixed Length
- instructs the scanner that the next two programming labels scanned will define the first fixed label length. This setting must be between 03 and 50
characters.
Set Second Fixed Length
- instructs the scanner that the next two programming labels scanned will define the second fixed label length. This setting must be between 03 and 50
1 characters.
No Second Fixed Length
- configures the scanner to recognize only the first fixed length.
102
1. For this symbology, the scanner will decode up to 50 characters, but the actual length read will vary depending upon the interface type, and bar code physical size and quality.
PowerScan™ RF Scanner
Start/Stop
Characters
Start/Stop Characters can be either Send or Don’t Send depending on your host’s interface requirement. Refer to your host user’s manual to identify your system requirements.
Start/Stop Match
Start/Stop Match can be enabled or disabled.
Start/Stop Format
Start/Stop Format can be set to one of four standard format options:
ABCD/TN*E, ABCD/ABCD, abcd/tn*e, or abcd/abcd. This setting must match your system requirements. If you select one of these options, it determines how the ASCII characters A, B, C, D (used for
Start/Stop characters) are translated before being sent to the host.
Read Verification
Read Verification is the number of times the scanner is required to read the bar code data before sending the label data to the host.
QuadraLogic™ II
Decoding
QuadraLogic™ II Decoding directs the scanner to decode labels with widespread problems of spots, voids, and/or non-uniform widths.
To optimize your scanner’s performance activate this option only for symbologies for which it is necessary.
There are many additional ways to configure the scanner to read and decode extremely poor labels. Contact your sales representative or service provider for other advanced QuadraLogic™ II Decoding settings.
Configuring the Codabar
Options
Codabar options are all applicable only to the scanner, with the exception of the features for setting Check Digit Transmission and Start/Stop Characters, which apply only to the Base Station.
Use the special bar codes in this section to configure the Codabar symbology options.
SET ------------------------------
RF Programming Manual
103
Check Digit
Don’t Calculate ---------
Calculate ---------
Don’t Transmit ---------
104
Gap Check
Enable ---------
Disable ---------
END ------------------------------
Transmit Scanner
Configuration to
Base Station ---------
Label Length
Format
Follow the steps below to set the Codabar label Length Format to select either the
Variable Length
or
Fixed Length Format.
PowerScan™ RF Scanner
Variable Length
Format
Follow the steps below to set the Codabar symbology to Variable
Length Format.
1.
Identify the minimum length setting you want to make. The selectable range is 03 to 50
1
characters.
2.
Scan the SET bar code below.
3.
Scan the ENABLE VARIABLE LENGTH FORMAT bar code.
4.
Scan the SET MINIMUM LABEL LENGTH bar code.
5.
Set the minimum label length by scanning the correct digits from
page 108 . Return to this page and go to step six.
If you are setting a label length less than ten, you must scan a zero digit first and then the length digit (e.g., 04, 06, 08).
NOTE
6.
Scan the END bar code.
Variable Length Format
SET ------------------------------------------
Enable Variable Length
Set Minimum Label
Length ---------
END ------------------------------------------
RF Programming Manual
1. For this symbology, the scanner will decode up to 50 characters, but the actual length read will vary depending upon the interface type, and bar code physical size and quality.
105
106
Fixed Length
Format
The scanner offers the option of requiring Codabar labels to have one or two fixed lengths in the Fixed Label Format. Follow the steps below to set Codabar symbology to Fixed Length Format.
1.
Identify the fixed length settings you want to make.
2.
Scan the SET bar code.
3.
Scan the ENABLE FIXED LENGTH FORMAT bar code.
4.
Scan the SET FIRST FIXED LENGTH bar code.
5.
Set the first fixed label length by scanning the applicable digit bar codes from the
. Return to this page.
If you are setting a label length less than ten, you must scan a zero digit first and then the length digit (e.g., 04, 06, 08).
NOTE
If you need to set a second fixed length, continue with step six. If you do not need to set a second fixed length, skip to step nine.
6.
Scan the SET SECOND FIXED LENGTH bar code.
7.
Set the second fixed label length by scanning the applicable digits bar codes from the
8.
Return to this page and go to step ten.
If you are setting a label length less than ten, you must scan a zero digit first and then the length digit (e.g., 04, 06, 08).
NOTE
9.
Scan the NO SECOND FIXED LENGTH bar code.
10.
Scan the END bar code.
PowerScan™ RF Scanner
SET ------------------------------------------
Enable Fixed Length
Format ---------
Set First Fixed Length ---------
Set Second Fixed Length ---------
No Second Fixed Length ---------
END ------------------------------------------
RF Programming Manual
107
108
4
5
2
3
6
7
8
9
Digits
0
1
---------
---------
---------
---------
---------
---------
---------
---------
---------
---------
PowerScan™ RF Scanner
RF Programming Manual
Feature is specific to Base Station ONLY
Start/Stop Characters
SET ------------------------------------------
Match not required ---------
Match Required ---------
Don’t Transmit ---------
Transmit a
(requires Format) ---------
a. Choosing Transmit Start/Stop characters requires selecting one of these four data format selections: ABCD/TN*E, abcd/tn*e, ABCD/ABCD, or abcd/abcd.
109
Format = ABCD/
TN*E ---------
Format = abcd/ tn*e ---------
Format = ABCD/
ABCD ---------
Format = abcd/ abcd ---------
END ------------------------------
Transmit Scanner
Configuration to
Base Station ---------
110
PowerScan™ RF Scanner
Read Verification
Scan the bar codes below to set the number of reads desired to verify
Codabar symbology.
NOTE
The more times the scanner is required to read and compare the bar codes data, the longer the scanner will take to validate and transmit a label.
SET ------------------------------------------
Set Read to One read ---------
Set to Two reads ---------
Set Read to Three reads ---------
Set to Four reads ---------
END ------------------------------------------
RF Programming Manual
111
QuadraLogic™ II
Decoding
Scan these bar codes to activate/deactivate the QuadraLogic™ II
Decoding feature for the Codabar symbology.
SET ------------------------------------------
Activate for Codabar ---------
Deactivate for Codabar ---------
END ------------------------------------------
112
PowerScan™ RF Scanner
UPC/EAN Options
Data Format
Settings
UPC/EAN
Expansion
UPC/EAN
Add-ons
The UPC/EAN symbologies have the following programmable features:
•
Data Format Settings
•
UPC/EAN Expansion
•
UPC/EAN Add-ons
•
Price/Weight Check Digit
•
Read Verification
•
QuadraLogic™ II Decoding.
UPC/EAN Data Format Settings provides options for transmitting
Check Digits or Number System Digits (NSD).
Expand UPC-A to EAN-13 adds a leading zero to a UPC-A label which
‘expands’ the label to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for
EAN-13.
Expand UPC-E to UPC-A expands UPC-E labels to UPC-A data format.
Selecting this feature also changes the symbology ID to match those required for UPC-A.
Expand EAN-8 to EAN-13 adds five zeros in front of an EAN-8 label.
Data is sent in EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13.
Expand UPC-E to EAN-13 expands UPC-E labels to EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13.
UPC-A or UPC-E and EAN-8 or EAN-13 Two and Five Digit
Add-ons filters
Required
means UPC/EAN bar codes must have add-ons or label will not be read.
Optional
means scanner will read UPC/EAN bar codes with or without add-ons.
Disable
directs the scanner not to recognize/read add-on portions of UPC/EAN labels, but will read the main body of the label.
RF Programming Manual
113
Price/Weight Check
Digit
Price/Weight Check Digit provides options for enabling price/weight check digits. The feature includes selections for domestic four or five digit, and European four or five digit, as well as the option to disable the price/weight check.
Read Verification
Read Verification is the number of times the scanner is required to read the bar code data before sending the label data to the host.
QuadraLogic™ II
Decoding
QuadraLogic™ II Decoding directs the scanner to decode labels with widespread problems of spots, voids, and/or non-uniform widths.
To optimize your scanner’s performance activate this option only for symbologies for which it is necessary.
There are many additional ways to configure the scanner to read and decode extremely poor labels. Contact your sales representative or service provider for other advanced QuadraLogic™ II Decoding settings.
114
PowerScan™ RF Scanner
UPC/EAN
Options
UPC Data Format
Settings
Use the special bar codes in this section to configure the UPC/ EAN options.
UPC Data Format Settings are specific to Base Station ONLY
These settings affect UPC data format. Number System Digit (NSD) settings operate with RS-232 and Keyboard Wedge interfaces ONLY.
Scan the bar codes below to send or not send the Check Digit/NSD.
SET ------------------------------
UPC-A
Send Check
Digit ---------
Don’t Send
Check Digit ---------
Send NSD a
---------
Don’t Send NSD
RF Programming Manual
a. NSD = Number System Digit. The NSD character is the character that precedes the UPC bar code. The NSD for regular UPC-A bar codes is a zero.
Other commonly used Number System Digits used with UPC-A are:
“2” - used for random weight items such as meat and produce.
“3” - used for the drug and health items.
“4” - used for in-store non-food items.
“5” - used for coupons.
115
116
UPC-E
Digit a
---------
Don’t Send
Check Digit
---------
Send NSD
---------
Don’t Send NSD
END -----------------------------
Transmit Scanner
Configuration to
Base Station ---------
a. If UPC-E is expanded to UPC-A, the transmission of Check Digit (CD) and
NSD will be determined by the UPC-A settings on this page.
PowerScan™ RF Scanner
EAN Data Format
Settings
These settings affect EAN data format.
EAN Data Format Settings are specific to Base Station ONLY
SET ------------------------------------------
EAN-13
Send Check Digit ---------
Don’t Send Check Digit ---------
Send NSD
---------
Don’t Send NSD a
---------
a. NSD = Number System Digit. The NSD character is the character that precedes the EAN bar code, as in this example.
Example: EAN with NSD
RF Programming Manual
117
EAN-8
Send Check
Digit ---------
Don’t Send
Check Digit ---------
END ------------------------------
Transmit Scanner
Configuration to
Base Station ---------
118
PowerScan™ RF Scanner
UPC/EAN
Expansion
UPC/EAN Expansion is specific to Base Station ONLY
Use these labels to activate:
•
Expand UPC-A to EAN-13
•
Expand UPC-E to UPC-A
•
Expand EAN-8 to EAN-13
•
Expand UPC-E to EAN-13
SET ------------------------------------------
UPC-A to EAN-13 Expansion
Expand a
---------
Don’t Expand ---------
UPC-E to UPC-A Expansion
Expand
---------
Don’t Expand ---------
RF Programming Manual
a. When any expansion features is activated, the transmission of the Prefix,
Suffix, Check Digit and Number System Digit (NSD) are controlled by your selections for the symbology ‘expanded to’ rather than the symbology ‘expanded from’. For example, if you expand UPC-E to UPC-A, settings for UPC-A determine how the scanner sends a bar code’s contents.
119
120
EAN-8 to EAN-13
Expansion
Expand a
---------
Don’t Expand ---------
UPC-E to EAN-13
Expansion
Expand
---------
Don’t Expand ---------
END ------------------------------
Transmit Scanner
Configuration to
Base Station ---------
a. When any expansion features is activated, the transmission of the Prefix,
Suffix, Check Digit and Number System Digit (NSD) are controlled by your selections for the symbology ‘expanded to’ rather than the symbology
‘expanded from’. For example, if you expand UPC-E to UPC-A, settings for
UPC-A determine how the scanner sends a bar code’s contents.
PowerScan™ RF Scanner
UPC/EAN
Add-ons
There are many ways to configure the scanner to handle add-ons. The scanner uses four filters that can be specified to define how add-ons will be handled. The following is true for each filter.
•
Each add-on type can be disabled, required or optional.
•
Any combination of the four UPC/EAN symbologies can be affected.
•
The 2-digit, 5-digit and C128 add-ons can be individually configured.
•
The leading digits of the base labels affected can be specified.
NOTE
The settings below represent only a small portion of the options available for this feature.
Contact your sales representative or service provider if you need more assistance with advanced add-on settings.
This programming guide supports the following add-on filters for
UPC/EAN:
• Required
means that UPC/EAN labels MUST contain a 2digit, 5-digit or C128 add-on segment in order for the scanner to recognize or decode them.
• Optional
directs the scanner to recognize UPC/EAN bar codes with or without P2, P5 or C128 2-digit add-on segments.
• Disable Add-ons
means the scanner will not recognize or decode any add-on segment of UPC/EAN labels, but will read and decode the standard UPC/EAN portion of the label.
NOTE
Due to the structure of add-on codes, selecting the optional setting makes it impossible to ensure that the scanner will always read the add-on portion of the label. PSC makes no guarantee, either written or implied, that scanners with optional add-on decoding enabled will perform with the speed and accuracy required for any given application.
RF Programming Manual
121
122
The following bar codes affect all four UPC/EAN symbologies, and will be applied to all labels regardless of the leading digits of the base label.
Feature is specific to scanner ONLY
SET ------------------------------------------
Add-ons Required ---------
Add-ons Option ---------
Disable Add-ons ---------
END ------------------------------------------
Custom
Add-ons
A wide array of add-on options are available to streamline your installation to its best advantage. Call your sales representative or service provider for assistance in customizing your scanner’s add-on capabilities to your own unique specifications.
PowerScan™ RF Scanner
Price/Weight Check
Digit
Feature is specific to scanner ONLY
The price/weight check digit selections allow you to specify whether the scanner should calculate an extra check digit based on a four or five-digit price/weight block and compare it with the price/weight check digit contained in the bar code. If the calculated check digit does not match the value of the check digit contained in the bar code, the label will be rejected as invalid. Select domestic four or five digit,
European four or five digit, or disable the price/weight check.
SET ------------------------------------------
Disable P/W Check ---------
Enable 4-Digit Check ---------
Enable 5-Digit ---------
Enable Euro 4-Digit ---------
Enable Euro 5-Digit ---------
END ------------------------------------------
RF Programming Manual
123
124
Read Verification
Feature is specific to scanner ONLY
Follow the steps below to set the number of minimum reads required to verify UPC/EAN symbologies.
To set the minimum read requirement for a desired symbology:
1.
Scan the SET bar code.
2.
Scan one symbology label from the list below to be verified.
3.
Scan the bar code on page 125 that represents the number of
times you wish a bar codes label of that symbology type to be read before transmission to the host from the list.
4.
Repeat steps two through three above until read verification has been modified for each of the the desired symbologies.
5.
Scan the END bar code on page 125.
Read Verification
SET --------------------------------------
Verify UPC-A ---------
Verify UPC-E ---------
PowerScan™ RF Scanner
RF Programming Manual
Verify EAN-13 ---------
Verify EAN-8 ---------
Verify Instore Label ---------
Number of Reads to Verify
One Read ---------
Two Reads ---------
Three Reads ---------
Four Reads ---------
END ------------------------------------------
125
126
QuadraLogic™ II
Decoding
Feature is specific to scanner ONLY
Scan these bar codes to activate/deactivate the QuadraLogic™ II
Decoding feature for the UPC/EAN symbologies.
To optimize your scanner’s performance activate this option only for symbologies for which it is necessary.
NOTE
SET ------------------------------------------
Activate for UPC-A/
EAN-13 ---------
Deactivate for UPC-A/
EAN-13 ---------
Activate for UPC-E ---------
Deactivate for UPC-E ---------
Activate for EAN-8 ---------
PowerScan™ RF Scanner
Deactivate for EAN-8 ---------
END ------------------------------------------
RF Programming Manual
127
Code 93 Options
The Code 93 symbology has the following programmable features:
•
Minimum Label Length
Minimum Label
Length
•
Read Verification
Minimum Label Length sets the minimum label length required for
Code 93 symbology. This feature causes the scanner to ignore small label segments, reducing the possibility that a portion of a good label is incorrectly seen as an entire label.
Read Verification
Read Verification is the number of times the scanner is required to read the bar code data before sending the label data to the host.
128
PowerScan™ RF Scanner
Configuring the Code 93
Options
Code 93 options are specific to scanner ONLY
Minimum Label
Length
Use these special bar codes to configure the Code 93 options.
1.
Identify the minimum length setting you want to make. The selectable range is 01 to 50
1
characters.
2.
Scan the SET bar code.
3.
Scan the SET MINIMUM LABEL LENGTH bar code.
4.
Set the minimum label length by scanning the applicable digits from
page 130 . The range is 01 to 50
page and go to step five.
If you are setting a label length less than ten, you must scan a zero digit first and then the length digit (e.g., 04, 06, 08).
NOTE
5.
Scan the END bar code.
SET ------------------------------------------
Set Minimum Label Length ---------
END ------------------------------------------
RF Programming Manual
1. For this symbology, the scanner will decode up to 50 characters, but the actual length read will vary depending upon interface type, and bar code physical size and quality. The IBM POS interface is limited to 32 character labels. Code 93 bar codes containing one or more shift characters can also limit the amount of characters that will be decoded (in these circumstances, the scanner will decode at least 39 data characters).
129
130
Digits
0
1
8
9
5
6
7
2
3
4
---------
---------
---------
---------
---------
---------
---------
---------
---------
---------
PowerScan™ RF Scanner
Read Verification
Scan the bar codes below to set the number of reads desired to verify
Code 93 symbology.
NOTE
The more times the scanner is required to read and compare the bar codes data, the longer the scanner will take to validate and transmit a label.
SET ------------------------------------------
Set to One read ---------
Set to Two reads ---------
Set to Three reads ---------
Set to Four reads ---------
END ------------------------------------------
RF Programming Manual
131
Standard 2 of 5/IATA Options
The Standard 2 of 5/IATA symbologies have the following programmable features:
•
Check Digit
•
Label Length Format
•
Read Verification
Check Digit
Check Digit calculates the Check Digit to verify that the Check Digit contained in the bar code label is correct. If you enable this feature, your bar codes must contain a Check Digit.
Label Length
Format
If the Check Digit is not calculated, the digit will be sent regardless of settings for transmit or don’t transmit. For example, if you choose to
Transmit Check Digit, but not calculate, the scanner sends the Check
Digit encoded in the bar code without verifying its accuracy.
Label length format permits the selection between variable length or fixed length formats. For best performance it is recommended to use the Fixed Length settings when your application requires only one or two label lengths.
Variable Length Format
— directs the scanner to read all labels from the minimum label length to 50. Set Minimum Length as high as your application allows.
Minimum Label Length
— selects the minimum label length that the scanner will recognize. The minimum label length for this symbology must be between 01 and 50
1
.
Fixed length Format
— directs the scanner to read only one or two label lengths.
If you select fixed length format, there are three bar code labels for programming your scanner to read either one or two fixed lengths. The labels are:
Set First Fixed Length
— instructs the scanner that the next two programming labels scanned will define the first fixed label length. This setting must be between 01 and 50
characters.
132
1. For this symbology, the scanner will decode up to 50 characters, but the actual length read will vary depending upon the interface type, and bar code physical size and quality.
PowerScan™ RF Scanner
Set Second Fixed Length
— instructs the scanner that the next two programming labels scanned will define the second fixed label length. This setting must be between 01 and 50
1 characters.
No Second Fixed Length
— configures the scanner to recognize only the first fixed length.
Read Verification
Read Verification is the number of times the scanner is required to read the bar code data before sending the label data to the host.
RF Programming Manual
1. For this symbology, the scanner will decode up to 50 characters, but the actual length read will vary depending upon the interface type, and bar code physical size and quality.
133
134
Configuring the Standard 2 of 5 Options
Standard 2 of 5 options are all applicable only to the scanner, with the exception of Check Digit Transmission, which applies only to the Base Station.
Use the special bar codes in this section to configure the Standard
2 of 5/IATA symbology options.
Check Digit
SET -------------------------------
Don’t Calculate ---------
Calculate ---------
Don’t Transmit ---------
Transmit ---------
END ------------------------------
Transmit Scanner
Configuration to
Base Station ---------
PowerScan™ RF Scanner
Label Length
Format
Variable Length
Format
Follow the steps below to set the Standard 2 of 5/IATA label length format to select either
Variable Length
or
Fixed Length
format.
Follow the steps below to set the Standard 2 of 5/IATA symbology to read Variable Length Format.
1.
Identify the minimum length setting you want to make. The selectable range is 02 to 50
1
characters.
2.
Scan the SET bar code below.
3.
Scan the ENABLE VARIABLE LENGTH FORMAT bar code.
4.
Scan the SET MINIMUM LABEL LENGTH bar code.
5.
Set the minimum label length by scanning the applicable digits
on page 138. Return to this page and go to step six.
If you are setting a label length less than ten, you must scan a zero digit first and then the length digit (e.g., 04, 06, 08).
NOTE
6.
Scan the END bar code.
Variable Length Format
SET ------------------------------------------
Enable Variable Length
Set Minimum Label
Length ---------
END ------------------------------------------
RF Programming Manual
1. For this symbology, the scanner will decode up to 50 characters, but the actual length read will vary depending upon the interface type, and bar code physical size and quality.
135
136
Fixed Length
Format
All interfaces that are shipped with the standard factory configuration are set to read variable length labels. If you switch from variable length to fixed length format, the default fixed labels are 14 characters and 8 digits. Follow the steps below to change these defaults for the Standard
2 of 5/IATA symbology.
1.
Identify the fixed length settings you want to make.
2.
Scan the SET bar code.
3.
Scan the ENABLE FIXED LENGTH FORMAT bar code .
4.
Scan the SET FIRST FIXED LENGTH bar code.
5.
Set the first fixed label length by scanning the applicable digits bar codes on
page 138 , then return to this page.
If you are setting a label length less than ten, you must scan a zero digit first and then the length digit (e.g., 04, 06, 08).
NOTE
If you need to set a second fixed length, continue with step six. If you do not need to set a second fixed length skip to step nine.
6.
Scan the SET SECOND FIXED LENGTH bar code.
7.
Set the second fixed label length by scanning the applicable digits bar codes on
8.
Return to this page and go to step ten.
If you are setting a label length less than ten, you must scan a zero digit first and then the length digit (e.g., 04, 06, 08).
NOTE
9.
Scan the NO SECOND FIXED LENGTH bar code.
10.
Scan the END bar code.
PowerScan™ RF Scanner
Fixed Length Format
SET ------------------------------------------
Enable Fixed Length
Set First Fixed Length ---------
Set Second Fixed Length ---------
No Second Fixed Length ---------
END ------------------------------------------
RF Programming Manual
137
138
Digits
0
1
4
5
6
2
3
7
8
9
---------
---------
---------
---------
---------
---------
---------
---------
---------
---------
PowerScan™ RF Scanner
Read Verification
Scan the bar codes below to set the number of reads desired to verify
Standard 2 of 5/IATA symbologies.
NOTE
The more times the scanner is required to read and compare the bar code data, the longer the scanner will take to validate and transmit a label.
SET ------------------------------------------
Set to One read ---------
Set to Two reads ---------
Set to Three reads ---------
Set to Four reads ---------
END ------------------------------------------
RF Programming Manual
139
IATA
Feature is applicable to scanner and Base Station.
IATA is a special symbology subset of Standard 2 of 5. Enabling IATA selects this custom code as the active Standard 2 of 5 symbology. When
IATA is enabled, Standard 2 of 5 labels will not be read. Scan the bar code labels below to enable/disable IATA.
SET ------------------------------
Disable ---------
END -----------------------------
Transmit Scanner
Configuration to
Base Station ---------
140
PowerScan™ RF Scanner
MSI/Plessey Options
MSI/Plessey options are all applicable only to the scanner, with the exception of Check Digit Transmission, which applies only to the Base Station.
The MSI/Plessey symbology has the following programmable features:
•
Check Digit
•
Label Length Format
•
Read Verification
Check Digit
Check Digit calculates the Check Digit(s) to verify the labels contents have been read correctly. If you enable this feature, your bar codes must include a Check Digit(s). You may also choose to transmit or not transmit the Check Digit(s).
Check Digit Calculation
- enables or disables calculation of the Check Digit(s).
Transmit Check Digit
- enables or disables transmission of
MSI/Plessey Check Digit(s).
Number of Check Digits
- specifies either one or two Check
Digits.
Label Length
Format
Label length format permits the selection between variable length or fixed length formats. For best performance it is recommended to use the Fixed Length settings when your application requires only one or two label lengths.
Variable Length Format
- directs the scanner to read all labels from the minimum label length to 16. Set Minimum Length as high as your application allows.
Minimum Label Length
- selects the minimum label length that the scanner will recognize. The minimum label length for this symbology must be between 04 and 16.
Fixed Length Format
- directs the scanner to read only one or two label lengths.
If you select fixed length format, there are three bar code labels for programming your scanner to read either one or two fixed lengths. The labels are:
RF Programming Manual
141
Set First Fixed Length
- instructs the scanner that the next two programming labels scanned will define the first fixed label length. This setting must be between 04 and 16 characters.
Set Second Fixed Length
- instructs the scanner that the next two programming labels scanned will define the second fixed label length. This setting must be between 04 and 16 characters.
No Second Fixed Length
- configures the scanner to recognize only the label length chosen as the first fixed length.
Read Verification
Read Verification is the number of times the scanner is required to read the bar code data before sending the label data to the host.
142
PowerScan™ RF Scanner
Configuring the MSI /
Plessey
Options
Use the special bar codes in this section to configure the MSI/Plessey symbology options.
Check Digit
SET -----------------------------
Calculate ---------
Don’t Calculate ---------
Transmit ---------
Don’t Transmit ---------
One Check
Digit ---------
Two Check
Digits ---------
END -----------------------------
Transmit Scanner
Configuration to
Base Station ---------
RF Programming Manual
143
144
Label Length
Format
Variable Length
Format
Follow the steps below to set the MSI/Plessey label length format to either the
Variable Length
or
Fixed Length
format.
Follow the steps below to set the MSI/Plessey to read Variable Length
Format.
1.
Identify the minimum length setting you want to make. The selectable range is 04 to 16 characters.
2.
Scan the SET bar code.
3.
Scan the ENABLE VARIABLE LENGTH FORMAT bar code.
4.
Scan the SET MINIMUM LABEL LENGTH bar code.
5.
Set the minimum label length by scanning the applicable digits bar codes on
page 147 , then return to this page.
If you are setting a label length less than ten, you must scan a zero digit first and then the length digit (e.g., 04, 06, 08).
NOTE
6. Scan the END bar code.
Variable Length
SET ------------------------------------------
Enable Variable Length
Set Minimum Label
Length ---------
END ------------------------------------------
PowerScan™ RF Scanner
Fixed Length
Format
The scanner offers the option of requiring MSI/Plessey labels to have one or two fixed length(s) in the Fixed Label Format. Follow the steps below to set the MSI/Plessey symbology to fixed length format.
1.
Identify the fixed length setting(s) you wish to make. Fixed lengths can be set from 04 to 16 characters.
2.
Scan the SET bar code on page 146 .
3.
Scan the ENABLE FIXED LENGTH FORMAT bar code.
4.
Scan the SET FIRST FIXED LENGTH bar code.
5.
Set the first fixed label length by scanning the applicable digits on
. Return to this page.
If you are setting a label length less than ten, you must scan a zero digit first and then the length digit (e.g., 04, 06, 08).
NOTE
If you need to set a second fixed length, continue with step six. If you do not need a second fixed length skip to step nine.
6.
Scan the SET SECOND FIXED LENGTH bar code.
7.
Set the second fixed label length by scanning the applicable
8.
Return to this page and go to step ten.
If you are setting a label length less than ten, you must scan a zero digit first and then the length digit (e.g., 04, 06, 08).
NOTE
9.
Scan the NO SECOND FIXED LENGTH bar code.
10.
Scan the END bar code on
RF Programming Manual
145
146
Fixed Length
SET ------------------------------------------
Enable FIxed Length
Set First Fixed Length ---------
Set Second Fixed Length ---------
No Second Fixed
Length ---------
END ------------------------------------------
PowerScan™ RF Scanner
RF Programming Manual
Digits
0
3
4
5
1
2
6
7
8
9
---------
---------
---------
---------
---------
---------
---------
---------
---------
---------
147
148
Read Verification
Scan the bar codes below to set the number of reads desired to verify
MSI/Plessey symbologies.
NOTE
The more times the scanner is required to read and compare the bar codes data, the longer the scanner will take to validate and transmit a label.
SET ------------------------------------------
Set to One read ---------
Set to Two reads ---------
Set to Three reads ---------
Set to Four reads ---------
END ------------------------------------------