Psion Teklogix PowerScan 7000 Linear Imager User Manual
Реклама
Реклама
Psion Teklogix
PowerScan
®
7000
Linear Imager
User Manual
April 27, 2007 Part No. 8100094.B
ISO 9001 Certified Quality
Management System
Patents
This product may be covered by one or more of the following patents: 4603262 • 4639606 • 4652750
• 4672215 • 4699447 • 4709369 • 4749879 4786798 • 4792666 • 4794240 • 4798943 • 4799164 • 4820911
• 4845349 • 4861972 • 4861973 • 4866257 • 4868836 • 4879456 • 4939355 • 4939356 • 4943127 •
4963719 • 4971176 • 4971177 • 4991692 • 5001406 • 5015831 • 5019697 • 5019698 • 5086879 • 5115120
• 5144118 • 5146463 • 5179270 • 5198649 • 5200597 • 5202784 • 5208449 • 5210397 • 5212371 •
5212372 • 5214270 • 5229590 • 5231293 • 5232185 • 5233169 • 5235168 • 5237161 • 5237162 • 5239165
• 5247161 • 5256864 • 5258604 • 5258699 • 5260554 • 5274219 • 5296689 • 5298728 • 5311000 •
5327451 • 5329103 • 5330370 • 5347113 • 5347121 • 5371361 • 5382783 • 5386105 • 5389917 • 5410108
• 5420410 • 5422472 • 5426507 • 5438187 • 5440110 • 5440111 • 5446271 • 5446749 • 5448050 •
5463211 • 5475206 • 5475207 • 5479011 • 5481098 • 5491328 • 5493108 • 5504350 • 5508505 • 5512740
• 5541397 • 5552593 • 5557095 • 5563402 • 5565668 • 5576531 • 5581707 • 5594231 • 5594441 •
5598070 • 5602376 • 5608201 • 5608399 • 5612529 • 5629510 • 5635699 • 5641958 • 5646391 • 5661435
• 5664231 • 5666045 • 5671374 • 5675138 • 5682028 • 5686716 • 5696370 • 5703347 • 5705802 •
5714750 • 5717194 • 5723852 • 5750976 • 5767502 • 5770847 • 5786581 • 5786585 • 5787103 • 5789732
• 5796222 • 5804809 • 5814803 • 5814804 • 5821721 • 5822343 • 5825009 • 5834708 • 5834750 •
5837983 • 5837988 • 5852286 • 5864129 • 5869827 • 5874722 • 5883370 • 5905249 • 5907147 • 5923023
• 5925868 • 5929421 • 5945670 • 5959284 • 5962838 • 5979769 • 6000619 • 6006991 • 6012639 •
6016135 • 6024284 • 6041374 • 6042012 • 6045044 • 6047889 • 6047894 • 6056198 • 6065676 • 6069696
• 6073849 • 6073851 • 6094288 • 6112993 • 6129279 • 6129282 • 6134039 • 6142376 • 6152368 •
6152372 • 6155488 • 6166375 • 6169614 • 6173894 • 6176429 • 6188500 • 6189784 • 6213397 • 6223986
• 6230975 • 6230976 • 6237852 • 6244510 • 6259545 • 6260763 • 6266175 • 6273336 • 6276605 •
6279829 • 6290134 • 6290135 • 6293467 • 6303927 • 6311895 • 6318634 • 6328216 • 6332576 • 6332577
• 6343741 • 6454168 • 6478224 • 6568598 • 6578765 • 6705527 • 6974084 • 6991169 •7051940 •
AU703547 • D312631 • D313590 • D320011 • D320012 • D323492 • D330707 • D330708 • D349109 •
D350127 • D350735 • D351149 • D351150 • D352936 • D352937 • D352938 • D352939 • D358588 •
D361565 • D372234 • D374630 • D374869 • D375493 • D376357 • D377345 • D377346 • D377347 •
D377348 • D388075 • D446524 • EP0256296 • EP0260155 • EP0260156 • EP0295936 • EP0325469 •
EP0349770 • EP0368254 • EP0442215 • EP0498366 • EP0531645 • EP0663643 • EP0698251 •
GB2252333 • GB2284086 • GB2301691 • GB2304954 • GB2307093 • GB2308267 • GB2308678 •
GB2319103 • GB2333163 • GB2343079 • GB2344486 • GB2345568 • GB2354340 • ISR107546 •
ISR118507 • ISR118508 • JP1962823 • JP1971216 • JP2513442 • JP2732459 • JP2829331 • JP2953593
• JP2964278 • MEX185552 • MEX187245 • RE37166 • Other Patents Pending
Copyright © 2007 Psion Teklogix Inc. Mississauga, Ontario
All rights reserved. This document is an unpublished work and the information it contains is the property of Psion Teklogix, or its licensors, is issued in strict confidence, and may not be reproduced or copied, in whole or in part, except with written consent from Psion Teklogix. Furthermore, this document is not to be used as a basis for design, manufacture, or subcontract, or in any manner detrimental to the interests of Psion or its licensors. Psion
®
, Teklogix
®
, and all Psion Teklogix products and brand names are trademarks of Psion Teklogix and its affiliates.
All trademarks are the property of their respective holders.
Return-To-Factory Warranty
Psion Teklogix Inc. provides a return to factory warranty on this product for a period of twelve (12) months in accordance with the Statement of Limited Warranty and Limitation of Liability provided at www.psionteklogix.com/warranty. (If you are not already a member of
Teknet and you attempt to view this warranty, you will be asked to register. As a member of Teknet, you will have access to helpful information about your Psion Teklogix products at no charge to you.) In some regions, this warranty may exceed this period. Please contact your local
Psion Teklogix office for details. For a list of offices, see “Support Services And Worldwide Offices”, below. The warranty on Psion Teklogix manufactured equipment does not extend to any product that has been tampered with, altered, or repaired by any person other than an employee of an authorized Psion Teklogix service organization. See
Psion Teklogix terms and conditions of sale for full details.
Important: Psion Teklogix warranties take effect on the date of shipment.
Support Services And Worldwide Offices
Psion Teklogix provides a complete range of product support services to its customers worldwide. These services include technical support and product repairs.
Technical Support
For technical support in North America:
Call Toll free: +1 800 387 8898 Option 3 or
Direct Dial: +1 905 813 9900 Ext. 1999 Option 3
For technical support in EMEA (Europe, Middle East and Africa),
please contact the local office listed in the website below:
http://www.psionteklogix.com/EMEASupport
For technical support in Asia, please contact the local office listed in
the website below:
http://www.psionteklogix.com
Technical Support for Mobile Computing Products is provided via email through the Psion Teklogix customer and partner extranets. To reach the website, go to
www.psionteklogix.com
, and click on the appro-
priate Teknet link on the home page. Then click on the “Login” button or the “Register” button, depending on whether you have previously registered for Teknet. Once you have logged in, search for the “Support Request
Form”.
Product Repairs
For repair service in North America:
Call Toll free: +1 800 387 8898 Option 2 or
Direct Dial: +1 905 813 9900 Ext. 1999 Option 2
For repair service in EMEA (Europe, Middle East and Africa), please contact the local office listed in the website below:
http://www.psionteklogix.com/EMEASupport
For repair service in Asia, please contact the local office listed in the website below:
http://www.psionteklogix.com
Worldwide Offices
C
OMPANY
H
EADQUARTERS
Psion Teklogix Inc.
2100 Meadowvale Blvd.
Mississauga, Ontario
Canada L5N 7J9
Tel: +1 905 813 9900
Fax: +1 905 812 6300
E-mail: [email protected]
C
ANADIAN
S
ERVICE
C
ENTRE
Psion Teklogix Inc.
7170 West Credit Ave., Unit #1
Mississauga, Ontario
Canada L5N 7J9
Tel: +1 800 387 8898 Option 2 - or -
Direct: + 1 905 813 9900 Ext. 1999, Option 2
Fax: + 1 905 812 6304
E-mail: www.psionteklogix.com
N
ORTH
A
MERICAN
H
EADQUARTERS
A
ND
U.S. S
ERVICE
C
ENTRE
Psion Teklogix Corp.
1810 Airport Exchange Blvd., Suite 500
Erlanger, Kentucky
USA 41018
Tel: +1 859 371 6006
Fax: +1 859 371 6422
E-mail: [email protected]
I
NTERNATIONAL
S
UBSIDIARIES
(
see also www.psionteklogix.com/Subsidiaries
)
Psion Teklogix S.A.
La Duranne, 135 Rue Rene Descartes
BP 421000
13591 Aix-En-Provence
Cedex 3; France
Tel:
Fax:
+33 4 42 90 88 09
+33 4 42 90 88 88
E-mail: [email protected]
Waste Electrical and Electronic Equipment (WEEE) Directive
2002/96/EC
This Product, and its accessories, comply with the requirements of the
Waste Electrical and Electronic Equipment (WEEE) Directive
2002/96/EC. If your end-of-life Psion Teklogix product or accessory carries a label as shown here, please contact your local country representative for details on how to arrange recycling. For a list of international subsidiaries, please go to:
www.psionteklogix.com/EnvironmentalCompliance
Restriction On Hazardous Substances (RoHS) Directive
2002/95/EC
What is RoHS?
The European Union has mandated that high environmental standards be met in the design and manufacture of electronic and electrical products sold in Europe, to reduce hazardous substances from entering the environment. The “Restriction on Hazardous Substances Directive
(RoHS)” prescribes the maximum trace levels of lead, cadmium, mercury, hexavalent chromium, and flame retardants PBB and PBDE that may be contained in a product. Only products meeting these high environmental standards may be “placed on the market” in EU member states after July 1, 2006.
RoHS Logo
Although there is no legal requirement to mark RoHS-compliant products, Psion Teklogix Inc. indicates its compliance with the directive as follows:
The RoHS logo located either on the back of the product or underneath the battery in the battery compartment (or on a related accessory such as the charger or docking station) signifies that the product is RoHS-compliant as per the EU directive. Other than as noted below, a Psion Teklogix product that does not have an accompanying RoHS logo signifies that it was placed on the EU market prior to July 1, 2006, and is thereby exempt from the directive.
Note: Not all accessories or peripherals will have a RoHS logo due to physical space limitations or as a result of their exempt status.
Disclaimer
Every effort has been made to make this material complete, accurate, and upto-date. In addition, changes are periodically added to the information herein; these changes will be incorporated into new editions of the publication.
Psion Teklogix Inc. reserves the right to make improvements and/or changes in the product(s) and/or the program(s) described in this document without notice, and shall not be responsible for any damages, including but not limited to consequential damages, caused by reliance on the material presented, including but not limited to typographical errors.
Table of Contents
About This Manual ............................................................................ 1-1
Manual Conventions .................................................................... 1-2
Connecting the Scanner ..................................................................... 1-2
Programming ............................................................................. 1-4
Resetting the Standard Product Defaults .............................................. 1-4
Double Read Timeout ........................................................................ 2-1
Powerdown Timeout .......................................................................... 2-3
LED and Beeper Indicators ................................................................. 2-5
Power On Alert ........................................................................... 2-5
LED Idle State ............................................................................ 2-6
Good Read: When to Indicate ....................................................... 2-7
Good Read Beep Control .............................................................. 2-8
Good Read Beep Frequency ......................................................... 2-9
Good Read Beep Length ............................................................ 2-10
Good Read Beep Volume ........................................................... 2-12
Scanning Features .......................................................................... 2-13
Scan Mode .............................................................................. 2-13
Active Scanning Time ................................................................ 2-15
Laser Pointer Control ................................................................ 2-17
Interface Selection ............................................................................ 3-4
Interface Features ............................................................................ 3-9
Global Interface Features ............................................................ 3-9
RS-232 Interface Features ......................................................... 3-10
Hardware Flow Control......................................................... 3-14
Intercharacter Delay............................................................ 3-14
Software Flow Control.......................................................... 3-14
Host Echo .......................................................................... 3-18
Host Echo Quiet Interval ...................................................... 3-18
Signal Voltage: Normal/TTL .................................................. 3-18
RS-232 Invert..................................................................... 3-18
Beep on ASCII BEL .............................................................. 3-21
Beep on Not on File ............................................................. 3-21
ACK NAK Options ................................................................ 3-22
ACK Character .................................................................... 3-24
NAK Character .................................................................... 3-25
Retry on ACK NAK Timeout................................................... 3-26
ACK NAK Timeout Value ....................................................... 3-27
ACK NAK Retry Count .......................................................... 3-28
ACK NAK Error Handling ............................................................ 3-29
Transmission Failure Indication ............................................. 3-30
IBM-USB Interface Features ....................................................... 3-31
IBM-USB Device usage......................................................... 3-31
IBM ........................................................................................ 3-32
IBM Transmit Labels in Code 39 Format ................................. 3-32
Wand Emulation ....................................................................... 3-33
Supported Symbologies ....................................................... 3-33
Wand Emulation Bar Code Format ......................................... 3-33
User Manual i
ii
Bar/Space Polarity ...............................................................3-34
Wand Idle State ..................................................................3-34
Signal Speed.......................................................................3-36
Transmit Leading Noise ........................................................3-37
Transmit Trailing Noise .........................................................3-38
Symbology Conversion .........................................................3-39
Keyboard Wedge/USB Keyboard ..................................................3-41
Data Editing Overview .......................................................................4-1
Please Keep In Mind... .................................................................4-2
Global Prefix/Suffix ............................................................................4-2
Case Conversion .......................................................................4-15
Character Conversion ................................................................4-16
Disable/Enable UPC-A ..................................................................5-2
Check Digit Transmission .............................................................5-2
Expand UPC-A to EAN-13 .............................................................5-2
System Number Transmission .......................................................5-2
UPC-A Minimum Reads ................................................................5-5
In-store Minimum Reads ..............................................................5-6
Add-On Timer .............................................................................5-7
Disable/Enable UPC-E ..................................................................5-8
Check Digit Transmission .............................................................5-8
System Number ..........................................................................5-8
Expand UPC-E to UPC-A ...............................................................5-8
Expand UPC-E to EAN13 ..............................................................5-8
Minimum Reads ........................................................................5-11
GTIN .......................................................................................5-12
Disable/Enable GTIN ..................................................................5-12
Disable/Enable EAN-13 ..............................................................5-13
Check Digit Transmission ...........................................................5-13
EAN-13 Flag 1 Character ............................................................5-13
ISBN .......................................................................................5-13
Minimum Reads ........................................................................5-16
Disable/Enable EAN-8 ................................................................5-17
Check Digit Transmission ...........................................................5-17
Minimum Reads ........................................................................5-19
Disable/Enable RSS-14 ..............................................................5-22
UCC/EAN 128 Emulation ............................................................5-22
Minimum Reads ........................................................................5-24
RSS-14 2D Component ..............................................................5-25
RSS Expanded ................................................................................5-26
Disable/Enable RSS Expanded ....................................................5-26
UCC/EAN 128 Emulation ............................................................5-26
Length Control ..........................................................................5-27
RSS Expanded Length 1, Length 2 Programming Instructions ..........5-29
Minimum Reads ........................................................................5-30
PowerScan® 7000 SRI
RSS Expanded 2D Component .................................................... 5-31
RSS Limited ................................................................................... 5-32
Disable/Enable RSS Limited ....................................................... 5-32
UCC/EAN 128 Emulation ............................................................ 5-32
Minimum Reads ........................................................................ 5-33
RSS Limited 2D Component ....................................................... 5-34
Disable/Enable Code 39 ............................................................. 5-35
Check Character Calculation ....................................................... 5-35
Check Character Transmit .......................................................... 5-35
Start/Stop Characters ............................................................... 5-35
Code 39 Full ASCII ................................................................... 5-35
Length Control ......................................................................... 5-38
Code 39 Length 1, Length 2 Programming Instructions .................. 5-40
Quiet Zones........................................................................ 5-41
Code 39 Stitching ..................................................................... 5-42
Minimum Reads ........................................................................ 5-43
Pharmacode 39 .............................................................................. 5-44
Disable/Enable Pharmacode 39 ................................................... 5-44
Start/Stop Characters ............................................................... 5-45
Check Character Transmit .......................................................... 5-45
Code 128 and EAN 128 .................................................................... 5-46
Transmit Function Characters ..................................................... 5-47
Length Control ......................................................................... 5-48
Code 128 Length 1, Length 2 Programming Instructions ................ 5-50
Code 128 Stitching ................................................................... 5-51
Minimum Reads ........................................................................ 5-52
Interleaved 2 of 5 ........................................................................... 5-53
Disable/Enable Interleaved 2 of 5 ............................................... 5-53
Check Digit Calculation .............................................................. 5-53
Check Digit Transmit ................................................................. 5-53
Length Control ......................................................................... 5-55
Interleaved 2 of 5 Length 1, Length 2 Programming Instructions .... 5-57
Interleaved 2 of 5 Stitching ....................................................... 5-58
Minimum Reads ........................................................................ 5-59
Disable/Enable Codabar ............................................................ 5-60
Check Character Verification ...................................................... 5-60
Check Character Transmit .......................................................... 5-60
Length Control ......................................................................... 5-62
Codabar Length 1, Length 2 Programming Instructions .................. 5-64
Quiet Zones........................................................................ 5-65
Start/Stop Character Type ......................................................... 5-66
Start/Stop Character Transmission ............................................. 5-66
Start/Stop Character Match ....................................................... 5-66
Codabar Stitching ..................................................................... 5-69
Minimum Reads ........................................................................ 5-70
Disable/Enable Code 93 ............................................................. 5-71
Length Control ......................................................................... 5-72
Code 93 Length 1, Length 2 Programming Instructions .................. 5-74
Code 93 Stitching ..................................................................... 5-75
Minimum Reads ........................................................................ 5-76
User Manual iii
iv
Disable/Enable Code 11 .............................................................5-77
Number of Check Characters ......................................................5-78
Check Character Transmit ..........................................................5-78
Length Control ..........................................................................5-79
Code 11 Length 1, Length 2 Programming Instructions ..................5-81
Minimum Reads ........................................................................5-82
MSI/Plessey ...................................................................................5-83
Disable/Enable MSI/Plessey ........................................................5-83
Check Digit Verification ..............................................................5-83
Check Digit Transmit .................................................................5-83
Length Control ..........................................................................5-86
MSI/Plessey Length 1, Length 2 Programming Instructions .............5-88
Scan the END bar code. .............................................................5-88
MSI/Plessey Stitching ................................................................5-89
Minimum Reads ........................................................................5-90
Disable/Enable Standard 2 of 5 ...................................................5-91
Check Digit Verification ..............................................................5-91
Check Digit Transmit .................................................................5-91
Length Control ..........................................................................5-93
Standard 2 of 5 Length 1, Length 2 Programming Instructions ........5-95
Standard 2 of 5 Stitching ...........................................................5-96
Minimum Reads ........................................................................5-97
Disable/Enable PDF 417 .............................................................5-98
Length Control ..........................................................................5-99
PDF 417 Length 1, Length 2 Programming Instructions ................ 5-101
Minimum Reads ...................................................................... 5-102
Micro PDF 417 .............................................................................. 5-103
Disable/Enable Micro PDF 417 ................................................... 5-103
PDF 128 Emulation .................................................................. 5-104
Length Control ........................................................................ 5-105
Micro PDF 417 Length 1, Length 2 Programming Instructions ........ 5-107
Minimum Reads ...................................................................... 5-108
Optical and Read Performance Parameters ........................................... A-1
Physical Properties ........................................................................... A-2
Electrical Parameters ........................................................................ A-2
Environmental Parameters ................................................................. A-3
Standard Cable Pinouts (Primary Interface Cables) ............................... B-1
RS-232 ..................................................................................... B-1
IBM Port 5B/9B/17 ..................................................................... B-1
IBM USB ................................................................................... B-2
USB & USB Keyboard .................................................................. B-2
Wand Emulation ........................................................................ B-2
Keyboard Wedge ........................................................................ B-3
Standard Feature Defaults ................................................................. D-1
Keyboard Model Cross Reference .........................................................E-1
Accepting RS-232 Commands .............................................................F-1
LED and Beep Indications .................................................................. H-1
PowerScan® 7000 SRI
Chapter 1
Getting Started
The PowerScan
®
7000 SRI (Standard Range Imager) marks a new performance level for handheld scanners. It delivers aggressive read rates and depths of field on 1D and stacked codes. This aggressiveness applies even in challenging reading environments where low lighting conditions and poor quality might make it difficult to read bar codes. You can rest assured your investment will continue to supply years of use by reading any bar codes you require, now or in the future.
Designed for today’s demanding commercial and industrial environments, the scanner offers superior image quality, speed, durability, and the ability to read poor quality bar codes. The unit is comfortable to hold, easy to use, rugged, and excellent for the most demanding applications.
About This Manual
This User Manual provides programming instructions for the scanner, plus product specifications and dimensions. For installation, maintenance, troubleshooting and warranty information, see the Quick Reference Guide (QRG). Copies of other publications for this product are downloadable free of charge from the website listed on the back cover of this manual.
The scanner is factory programmed for the most common terminal and communications settings. If you need to change these settings, programming is accomplished by scanning the bar codes in this manual.
Bold text and a yellow-highlighted background indicates the most common default setting for a feature/option.
User Manual 1-1
Getting Started
Manual Conventions
The symbols listed below are used in this manual to notify the reader of key issues or procedures that must be observed when using the scanner:
Notes contain information necessary for properly diagnosing, repairing and operating the scanner.
NOTE
CAUTION
The CAUTION symbol advises you of actions that could damage equipment or property.
Connecting the Scanner
Use the appropriate instructions below to connect the scanner to the terminal, PC or other host device. The scanner kit you ordered to match your interface should provide a compatible cable for your installation.
The scanner cable connection is secured using the “clamshell” retainer
referenced in the enlarged area of
over the cable connector as shown in the illustration, then fully seat the cable assembly into the scanner, aligning both the connector and the retainer boss with their respective openings. Secure the captive screws.
Upon completing the connection via the appropriate interface instruc-
section of this manual and scan the bar code to select the correct interface type.
RS-232 Serial Connection —
Turn off power to the terminal/PC and connect the scanner to the terminal/PC serial port via the RS-232
. If the terminal will not support POT (Power
Off the Terminal) to supply scanner power, use the approved power supply (AC Adapter). Plug the AC Adapter barrel connector into the socket on the RS-232 cable connector and the AC Adapter plug into a standard power outlet.
1-2 PowerScan® 7000 SRI
Figure 1
. RS-232 Serial Connection
Connecting the Scanner
Cable Connector
Retainer Boss
Captive
Screws
USB Connection —
Connect the scanner to a USB port on the terminal/PC using the correct USB cable for the interface type you ordered.
Reference
.
Figure 2. USB Connection
User Manual or...
W
B
U S an d
W e yb ed ge d or...
or...
IB
M
1-3
Getting Started
Wand Emulation Connection —
Connect the scanner to the appropriated port on the terminal/PC using the correct cable for the interface
IBM Connection —
Connect the scanner to the IBM port on the ter-
minal/PC using the correct IBM cable. Reference
Keyboard Wedge Connection —
The Keyboard Wedge cable has a
‘Y’ connection from the scanner. Connect the female to the male end from the keyboard and the remaining end at the keyboard port at the
Programming
The scanner is typically factory-configured with a set of default features standard to the interface type you ordered. After scanning the interface bar code from the
section, you can select other options and customize your scanner through use of the instructions and programming bar codes available in that section and also the
and
Resetting the Standard Product
Defaults
If you aren’t sure what programming options are in your scanner, or you’ve changed some options and want the factory settings restored, scan the Standard Product Default Settings bar code below. This will copy the factory configuration for the currently active interface to the current configuration.
Standard Product Default Settings
The programming section lists the factory default settings for each of the menu commands (indicated by shaded blocks and bold text) on the following pages.
1-4 PowerScan® 7000 SRI
Chapter 2
General Features
Double Read Timeout
The Double Read Timeout feature sets a time limit that determines how much time must pass before reading the same label again (e.g. two identical items in succession).
START
DURATION BAR CODE
0.1 Second
0.2 Second
0.3 Second
0.4 Second
User Manual 2-1
0.8 Second
0.9 Second
1 Second
END
General Features
Double Read Timeout — continued
START
DURATION BAR CODE
0.5 Second
0.6 Second
0.7 Second
2-2 PowerScan® 7000 SRI
Powerdown Timeout
Powerdown Timeout
The Powerdown Timeout feature sets the time for automatically switching the unit off when the scanner is not in use.
START
DURATION BAR CODE
Disable
5 Seconds
15 Seconds
30 Seconds
1 Minute
2 Minutes
User Manual 2-3
General Features
Powerdown Timeout — continued
START
DURATION BAR CODE
3 Minutes
4 Minutes
END
2-4 PowerScan® 7000 SRI
LED and Beeper Indicators
LED and Beeper Indicators
Power On Alert
Disables or enables the indication (from the Beeper) that the scanner is receiving power.
START
STATE BAR CODE
Disable
Enable
END
User Manual 2-5
General Features
LED Idle State
Specifies state of scanner’s LED when the scanner is ready to read a bar code.
START
STATE BAR CODE
Disable
Enable
END
2-6 PowerScan® 7000 SRI
LED and Beeper Indicators
Good Read: When to Indicate
This feature specifies when the scanner will provide indication (beep and/or flash its green LED) upon successfully reading a bar code.
Choices are:
• Good Read = Indicate after decode
• Good Read = Indicate after transmit
• Good Read = Indicate after CTS goes inactive, then active
NOTE
START
INDICATE
This option, which uses CTS, is only valid for RS-232 interfaces.
BAR CODE
After decode
After transmit
After CTS goes inactive, then active
END
User Manual 2-7
General Features
Good Read Beep Control
This feature enables/disables the scanner’s ability to beep upon a successful decode of a bar code.
START
STATE BAR CODE
Disable
Enable
END
2-8 PowerScan® 7000 SRI
LED and Beeper Indicators
Good Read Beep Frequency
Adjusts the good read beep to sound at a selectable low, medium or high frequency, selectable from the list below. (Controls the beeper’s pitch/ tone.)
START
FREQUENCY BAR CODE
Low
Medium
High
END
User Manual 2-9
General Features
Good Read Beep Length
Specifies the duration of a good read beep.
START
LENGTH BAR CODE
60msec
80msec
100msec
120msec
140msec
160msec
2-10 PowerScan® 7000 SRI
LED and Beeper Indicators
Good Read Beep Length — continued
START
LENGTH BAR CODE
180msec
200msec
END
User Manual 2-11
General Features
Good Read Beep Volume
Selects the beeper volume (loudness) upon a good read beep. There are three selectable volume levels.
START
VOLUME BAR CODE
Low
Medium
High
END
2-12 PowerScan® 7000 SRI
Scanning Features
Scanning Features
Scan Mode
Selects the scan operating mode for the scanner. Selections are:
• Single — When the trigger is pulled, scanning is activated until five seconds have elapsed or a bar code has been read or the trigger is released
• Triggerless — When the trigger is pulled, scanning is activated until any of the following occur:
-
- a bar code has been read
- the trigger is pulled a second time
feature gates double reads while in this mode.
• Stand — No trigger pull is required to read a bar code while in this mode. Scanning is turned on automatically (auto-sense) when an item is placed in the scanner's field of view and is turned off again
has expired. The
feature gates double reads while in this mode.
If the trigger is pulled, the scanner acts as if it is in single read mode.
Upon exiting Single Read mode while Stand Mode is enabled, the software will delay 2 seconds before beginning its auto-sense operation.
NOTE
• Stand With Illumination — Same as the option above, except that illumination is on while in this mode.
User Manual 2-13
General Features
Scan Mode — continued
START
MODE BAR CODE
Single
Triggerless
Stand
Stand w/Illum
END
2-14 PowerScan® 7000 SRI
5 Seconds
15 Seconds
30 Seconds
1 Minute
Scanning Features
Active Scanning Time
This setting determines the amount of time the scanner continues to scan in triggerless or stand mode (see
) once scanning has been activated.
START
DURATION BAR CODE
1 Second
2 Seconds
User Manual 2-15
General Features
Active Scanning Time — continued
START
DURATION BAR CODE
2 Minutes
3 Minutes
4 Minutes
END
2-16 PowerScan® 7000 SRI
Scanning Features
Laser Pointer Control
The Laser Pointer is a value-added option which might not have been included when your scanner was ordered.
NOTE
When the trigger is pressed and
, the laser pointer will be activated for the time period configured by this feature.
Immediately following this, the scanner will start scanning. Disabling this feature turns the pointer off.
START
DURATION BAR CODE
Disable
0.1 Seconds
0.2 Seconds
0.3 Seconds
0.4 Seconds
User Manual 2-17
General Features
Laser Pointer Control — continued
START
DURATION BAR CODE
0.5 Seconds
0.6 Seconds
0.8 Seconds
1 Second
1.2 Seconds
1.5 Seconds
2-18 PowerScan® 7000 SRI
Scanning Features
Laser Pointer Control — continued
START
DURATION BAR CODE
2 Seconds
2.5 Seconds
END
User Manual 2-19
General Features
NOTES
2-20 PowerScan® 7000 SRI
Chapter 3
Interface Related
Features
At the time of this writing, the Scanner supports the interfaces listed in
. Select the desired interface type from the table, then reference
the page number given for the customizable features section associated with each interface. See
for a description of each Keyboard
Wedge interface type (A through Z as listed).
User Manual 3-1
Interface Related Features
Table 3-1. Interfaces Supported
RS-232 Page Keyboard Wedge
IBM
USB
Page
Keyboard Wedge
a
a. Consult Table 3-2 for more information regarding keyboard wedge inter-
face types.
NOTE
The correct interface cable is included for the scanner interface type you ordered.
3-2 PowerScan® 7000 SRI
Table 3-2. Keyboard Wedge Interface Reference
I/F Type PCs Supported
A PC/XT w/Alternate Key Encoding
B
AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Alternate Key
Encoding
C PS/2 25 and 30 w/Alternate Key Encoding
D PC/XT w/Standard Key Encoding
E
AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Standard Key
Encoding
F PS/2 25 and 30 w/Standard Key Encoding
G IBM 3xxx w/122 keyboard
H IBM 3xxx w/102 keyboard
I PS/55 5530T w/104 keyboard
J NEC 9801
K WYSE 30/30+ WY-30 Keyboard 83 Keys
L
WYSE 60/85/99 GT/150/160/285 Style IBM Enhanced PC, 520/520ES
Style IBM Enhanced PC FR
WYSE 55/65/65 ES/120/185/325 Style IBM Enhanced PC
WYSE 60/85/99 GT/150/160/285 ANSI Keyboard 105 Keys, 520/520 ES
M
N
ANSI Keyboard 105 Keys
WYSE 55/65/65 ES/120/185/325 ANSI Keyboard 105 Keys
WYSE 60/85/99 GT/150/160/285 ASCII Kbd, 520/520 ES ASCII Kbd
WYSE 55/65/65 ES/120/185/325 ASCII Keyboard
O
WYSE 60/85/99 GT/150/160/285 ANSI W285 Keyboard 105 Keys, 520/
520 ES ANSI W285 Keyboard 105 Keys
WYSE 55/65/65 ES/120/185/325 ANSI W285 Keyboard 105 Keys
P WYSE WINTERM 3320 SE
Q
IBM 3153
IBM 316X, 3179/3180/319X/3270
R IBM 3151/3152-010, 347X/348X
S DIGITAL VT 220/320/330/340/350/382
T DIGITAL VT420
U DIGITAL VT 510/520 IBM ANSI Style Keyboard
V DIGITAL VT 510/520 IBM PC Style Keyboard
W SUN SPARC 5/10
X SUN 420/440, ITX
Y WYSE 370/355 Style Enhanced IBM PC
Reference
Appendix E, Keyboard Function Key Mappings
for more information about keyboards.
NOTE
User Manual 3-3
Interface Related Features
Interface Selection
START
INTERFACE BAR CODE
RS-232
Standard
RS-232
Wincor-Nixdorf
IBM 4683
Port 5B
IBM 4683
Port 9B
IBM 4683
Port 17
IBM USB
USB Keyboard
3-4 PowerScan® 7000 SRI
Interface Selection
Interface Selection — cont.
START
INTERFACE BAR CODE
Keyboard
Wedge A
Keyboard
Wedge B
Keyboard
Wedge C
Keyboard
Wedge D
Keyboard
Wedge E
Keyboard
Wedge F
Keyboard
Wedge G
User Manual 3-5
Interface Related Features
Interface Selection — cont.
START
INTERFACE BAR CODE
Keyboard
Wedge H
Keyboard
Wedge I
Keyboard
Wedge J
Keyboard
Wedge K
Keyboard
Wedge L
Keyboard
Wedge M
Keyboard
Wedge N
3-6 PowerScan® 7000 SRI
Interface Selection
Interface Selection — cont.
START
INTERFACE BAR CODE
Keyboard
Wedge O
Keyboard
Wedge P
Keyboard
Wedge Q
Keyboard
Wedge R
Keyboard
Wedge S
Keyboard
Wedge T
User Manual 3-7
Interface Related Features
Interface Selection — cont.
START
INTERFACE BAR CODE
Keyboard
Wedge U
Keyboard
Wedge V
Keyboard
Wedge W
Keyboard
Wedge X
Keyboard
Wedge Y
Wand
Emulation
END
3-8 PowerScan® 7000 SRI
Interface Features
Global Interface Features
START
STATE BAR CODE
Obey Host
Commands
Interface Features
Ignore Host
Commands
Host
Transmission
Buffers = 1
Host
Transmission
Buffers = 2
END
User Manual 3-9
Interface Related Features
RS-232 Interface Features
START
BAUD RATE BAR CODE
1200 Baud
2400 Baud
4800 Baud
9600 Baud
19200 Baud
38400 Baud
3-10 PowerScan® 7000 SRI
Interface Features
RS-232 Interface Features — cont.
START
BAUD RATE BAR CODE
57600 Baud
115200 Baud
END
User Manual 3-11
Interface Related Features
RS-232 Interface Features — cont.
START
STATE BAR CODE
7 Data Bits
8 Data Bits
1 Stop Bit
2 Stop Bits
Parity = None
3-12 PowerScan® 7000 SRI
Interface Features
RS-232 Interface Features — cont.
START
STATE BAR CODE
Parity = Even
Parity = Odd
END
User Manual 3-13
Interface Related Features
RS-232 Interface Features — cont.
Hardware Flow Control
Disable Hardware Control —
The scanner transmits to the host regardless of any activity on the CTS line.
Enable CTS Flow Control —
The CTS signal controls transmission of data to the host.
Enable CTS Scan Control —
The CTS line must be active for the scanner to read and transmit data. While the CTS line is inactive, the scanner remains in a host-disabled state; following a successful label transmission, the CTS signal must transition to inactive and then to active to enable scanning for the next label.
Intercharacter Delay
This delay is inserted after each data character transmitted. If the transmission speed is too high, the system may not be able to receive all characters. You may need to adjust the delay to make the system work properly.
Software Flow Control
Disables/Enables software control using XON/XOFF characters.
3-14 PowerScan® 7000 SRI
Enable CTS
Scan Control
Inter-Char
Delay = No
Delay
Interchar Delay
= 10 msec
Interchar Delay
= 20 msec
Interface Features
RS-232 Interface Features — cont.
START
STATE BAR CODE
Disable
Hardware
Control
Enable CTS
Flow Control
User Manual 3-15
Interface Related Features
RS-232 Interface Features — cont.
START
STATE BAR CODE
Interchar Delay
= 30 msec
Interchar Delay
= 40 msec
Interchar Delay
= 50 msec
Interchar Delay
= 60 msec
Interchar Delay
= 70 msec
Interchar Delay
= 80 msec
3-16 PowerScan® 7000 SRI
Interface Features
RS-232 Interface Features — cont.
START
STATE BAR CODE
Interchar Delay
= 90 msec
Disable
Software Flow
Control
Enable
Software Flow
Control
END
User Manual 3-17
Interface Related Features
RS-232 Interface Features — cont.
Host Echo
When enabled, this feature passes all data through the scanner to the host as it comes in. This feature is used for applications where “daisy chaining” of RS-232 devices onto the same cable is necessary. If, for example, one of the devices in the chain is a terminal where someone is entering data while another person is simultaneously scanning a bar code requiring transmission to the host, the scanner will wait for the RS-232 channel to be quiet for a specified period of time (set via
RS-232 Host Echo
Quiet Interval
). The scanner can be set to observe this delay before sending its data in order to avoid RS-232 transmission conflicts.
Host Echo Quiet Interval
This setting specifies the time interval of RS-232 channel inactivity which must transpire before the scanner will break the host echo loop to transmit the bar code data that has just been scanned to the host.
Signal Voltage: Normal/TTL
Specifies whether the RS-232 interface provides TTL levels on the output pins TxD and RTS.
RS-232 Invert
Enables/disables inversion of RS-232 TXD and RXD signals.
3-18 PowerScan® 7000 SRI
Interface Features
RS-232 Interface Features — cont.
START
STATE BAR CODE
Disable Host
Echo
Enable Host
Echo
Host Echo
Quiet Interval
= 0msec
Host Echo
Quiet Interval
= 10msec
Host Echo
Quiet Interval
= 20msec
Host Echo
Quiet Interval
= 30msec
User Manual 3-19
Interface Related Features
RS-232 Interface Features — cont.
START
STATE
Host Echo
Quiet Interval
= 40msec
BAR CODE
Host Echo
Quiet Interval
= 50msec
Host Echo
Quiet Interval
= 60msec
Host Echo
Quiet Interval
= 70msec
Host Echo
Quiet Interval
=80msec
Host Echo
Quiet Interval
= 90msec
Host Echo
Quiet Interval
= 100msec
3-20 PowerScan® 7000 SRI
Interface Features
RS-232 Interface Features — cont.
START
STATE
Signal
Voltage:
Normal RS-232
BAR CODE
Signal Voltage:
TTL
Disable
RS-232 Invert
Enable RS-232
Invert
END
Beep on ASCII BEL
Enables/disables ability of scanner to beep (sound a good read tone) on receiving an ASCII BEL (07 hex).
Beep on Not on File
Select for the host to beep (or not) when a not-on-file (host command) condition is detected by the host.
User Manual 3-21
Interface Related Features
ACK NAK Options
This enables/disables the ability of the scanner to support the RS-232
ACK/NAK protocol. When configured, the scanner and/or host sends an “ACK” when it receives data properly, and sends “NAK” when the data is in error. Selections for this option are:
• Disable
• Enable for label transmission — the scanner expects an ACK/NAK response from the host when a label is sent
• Enable for host-command acknowledge — the scanner will respond with ACK/NAK when the host sends a command
• Enable for label transmission and host-command acknowledge
START
STATE
Enable Beep on ASCII BEL
BAR CODE
Disable Beep on ASCII BEL
Disable Beep on Not On File
Enable Beep on Not On File
3-22 PowerScan® 7000 SRI
ACK NAK Options — cont.
START
STATE BAR CODE
Disable ACK
NAK
Enable ACK
NAK for
Transmission
Enable ACK
NAK for hostcommand acknowledge
Enable ACK
NAK for transmission and host-command
END
Interface Features
User Manual 3-23
Interface Related Features
RS-232 Interface Features — cont.
ACK Character
START
MODE BAR CODE
Sets the ACK character from the set of ASCII characters or any decimal value from 000 to 255. Pad entries of less than three digits with zeros, as in
“005”. To configure this feature, scan the “START” bar code above to place the unit in Programming Mode, then the “Set ACK Character,” followed by the digits from the Alphanumeric table in
representing your desired character.
Exit programming mode by scanning the “END” BAR
CODE below.
DEFAULT SETTING FOR THIS FEATURE:
006 (ACK)
Set ACK
Character
END
3-24 PowerScan® 7000 SRI
Interface Features
RS-232 Interface Features — cont.
NAK Character
START
MODE BAR CODE
Sets the NAK character from the set of ASCII characters or any decimal value from 000 to 255. Pad entries of less than three digits with zeros, as in
“005”. To configure this feature, scan the “START” bar code above to place the unit in Programming Mode, then the “Set NAK Character,” followed by the digits from the Alphanumeric table in
representing your desired character.
Exit programming mode by scanning the “END” BAR
CODE below.
DEFAULT SETTING FOR THIS FEATURE:
021 (!)
Set NAK
Character
END
User Manual 3-25
Interface Related Features
RS-232 Interface Features — cont.
Retry on ACK NAK Timeout
Enables/disables retry after the configurable ACK NAK Timeout Value
(set in the following feature) has expired.
START
STATE
Disable Retry on ACK NAK
Timeout
BAR CODE
Enable Retry on ACK NAK
Timeout
END
3-26 PowerScan® 7000 SRI
Interface Features
RS-232 Interface Features — cont.
ACK NAK Timeout Value
START
MODE BAR CODE
This item specifies the time the scanner will wait for an ACK character from the host following a label transmission.
000 = Infinite timeout
001 - 075 = Timeout in 200-millisecond increments
To configure this feature, scan the “START” bar code above to place the unit in Programming Mode, then the “Set ACK NAK Timeout Value,” followed by the three digits (zero padded) from the Alphanumeric table in
senting your desired value. Exit programming mode by scanning the “END” BAR CODE below
DEFAULT SETTING FOR THIS FEATURE: 001
Set ACK
NAK Timeout
Value
END
User Manual 3-27
Interface Related Features
RS-232 Interface Features — cont.
ACK NAK Retry Count
START
MODE BAR CODE
This feature sets the number of times for the scanner to retry a label transmission under a retry condition.
000 = No retry
001 - 254 = Retry for the specified number of times
255 = Retry forever
To configure this feature, scan the “START” bar code above to place the unit in Programming Mode, then the “Set ACK NAK Retry Count,” followed by the three digits (zero padded) from the Alphanumeric table in
senting your desired retry count. Exit programming mode by scanning the “END” BAR CODE below
DEFAULT SETTING FOR THIS FEATURE: 003
Set ACK
Nak Retry
Count
END
3-28 PowerScan® 7000 SRI
Interface Features
RS-232 Interface Features — cont.
ACK NAK Error Handling
This item specifies the method the scanner will use to handle errors detected while waiting to receive the ACK character from the host.
Errors include unrecognized host commands and communication errors such as parity or framing errors. Choices are:
00 = Ignore errors detected (recommended setting)
01 = Process error as valid ACK character (risk of lost label data)
02 = Process error as valid NAK character (risk of duplicate label data)
START
STATE BAR CODE
Ignore Errors
Detected
Process error as valid ACK character
Process error as valid NAK character
END
User Manual 3-29
Interface Related Features
RS-232 Interface Features — cont.
Transmission Failure Indication
Enables/disables bad-label indication upon transmission failure.
START
STATE
Disable
Transmission
Error Indication
BAR CODE
Enable
Transmission
Error
Indication
END
3-30 PowerScan® 7000 SRI
Interface Features
IBM-USB Interface Features
IBM-USB Device usage
The IBM-USB protocol allows for the scanner to be identified as one of two different types of bar code scanners. Depending on what other scanners you may already have connected to a IBM-USB POS, you may need to change this setting to enable all devices to communicate. Options are:
• Table Top Scanner
• Handheld Scanner
START
STATE
Configure as
Table Top
Scanner
BAR CODE
Configure as
Handheld
Scanner
END
User Manual 3-31
Interface Related Features
IBM
IBM Transmit Labels in Code 39 Format
This feature enables/disables scanner's ability to set a symbology identifier for a specified label to Code 39 before transmitting that label data to an IBM host. This applies to: Code 128, Codabar and Code 93 for IBM
USB; Code 128, Codabar and Code 93 for IBM Port 5B; and Codabar and Code 93 for IBM Port 9B.
START
STATE
Disable
Convert to
Code 39
BAR CODE
Enable Convert to Code 39
END
3-32 PowerScan® 7000 SRI
Interface Features
Wand Emulation
Supported Symbologies
The Wand Emulation interface will transmit bar code data as a wand device would. This interface will transmit the following bar code symbologies:
• UPC/EAN
• UPC/EAN with addons
• Code 39
• Full ASCII Code 39
• Interleaved 2 of 5
• Codabar
• Code 128
Pharmacode 39 is transmitted as Code 39, all other bar code symbology types read by the scanner will be transmitted as Code 128.
Wand Emulation Bar Code Format
The following format settings are required for the wand emulation interface. These settings have been pre-configured at the factory for Wand
Emulation scanners.
• UPC-A bar codes must include all 12 digits.
• UPC-E bar codes must contain 8 digits, including a system digit, 6 data digits, and the check digit.
• EAN-13 bar codes must have all 13 digits.
• EAN-8 bar codes must include all 8 digits.
• Code 39, Code 39 Full ASCII, and Pharmacode 39 bar codes must
NOT contain start / stop characters.
• Codabar bar codes must include the start / stop characters, presented in the ABCD format.
• Interleaved 2 of 5 bar codes must have an even number of digits.
User Manual 3-33
Interface Related Features
Wand Emulation — cont.
Bar/Space Polarity
Low/High — Black will be transmitted as a low voltage level (0 to
+0.7V) and space as high level (+2.4 to +5.25V).
High/Low — Black will be transmitted as a high voltage level (+2.4 to
+5.25V) and space as low level (0 to +0.7V).
Wand Idle State
This feature specifies the level of the wand output signal when idle. TTL logic levels:
High voltage level (+2.4 to +5.25V)
Low voltage level (0 to +0.7V).
START
STATE
Bar/Space =
Low/High
BAR CODE
Bar/Space =
High/Low
3-34 PowerScan® 7000 SRI
Wand Emulation — cont.
START
STATE BAR CODE
Wand Idle
State = Low
Interface Features
Wand Idle State
= High
END
User Manual 3-35
Interface Related Features
Wand Emulation — cont.
Signal Speed
The speed of the transmission can be set. This selects the width of the minimum narrow bar.
330 microseconds
660 microseconds
START
STATE
Signal Speed =
330mS
BAR CODE
Signal Speed =
660mS
3-36 PowerScan® 7000 SRI
Interface Features
Wand Emulation — cont.
Transmit Leading Noise
Enables/disables the ability of scanner to generate noise transitions before label transitions in signals transmitted to the host.
START
STATE BAR CODE
Disable
Leading Noise
Enable Leading Noise
END
User Manual 3-37
Interface Related Features
Wand Emulation — cont.
Transmit Trailing Noise
Enables/disables ability of scanner to generate noise transitions after label transitions in signals transmitted to the host.
START
STATE BAR CODE
Disable
Trailing Noise
Enable Trailing
Noise
END
3-38 PowerScan® 7000 SRI
Interface Features
Symbology Conversion
Wand Emulation can convert all bar codes to a single symbology.
Choices are:
No Conversion
Convert to Code 39
Convert to Code 128
START
STATE
Disable
Leading Noise
BAR CODE
Enable
Leading Noise
No Symbology
Conversion
User Manual 3-39
Interface Related Features
Symbology Conversion — cont.
START
STATE BAR CODE
Convert to C39
Convert to
C128
END
3-40 PowerScan® 7000 SRI
Interface Features
Keyboard Wedge/USB Keyboard
As a keyboard interface, the scanner supports most popular PCs and
IBM terminals. The installation of the wedge is a fairly simple process that doesn’t require any changes of software or hardware.
All of the options in this section apply to the Key-
apply to USB Keyboard.
NOTE
Keyboard Layout
The Keyboard Layout option supports many countries. For details about
Keyboard Layout, please refer to your operating system manual.
START
STATE BAR CODE
USA
Belgium
Britain
Denmark
User Manual 3-41
Interface Related Features
Keyboard Wedge/USB Keyboard — cont.
START
STATE BAR CODE
France
Germany
Spain
Sweden
3-42
Italy
Norway
Portugal
PowerScan® 7000 SRI
Interface Features
Keyboard Wedge/USB Keyboard — cont.
START
STATE BAR CODE
Switzerland
Japan 106 Key
Hungary
Czech
Slovakia
Romania
User Manual 3-43
Interface Related Features
Keyboard Wedge/USB Keyboard — cont.
START
STATE BAR CODE
Croatia
Poland
END
3-44 PowerScan® 7000 SRI
Interface Features
Keyboard Wedge/USB Keyboard — cont.
Caps Lock State
Specifies which format the scanner sends character data.
START
STATE BAR CODE
Disable Caps
Lock
Caps Lock “ON”
Shift Lock “ON”
END
User Manual 3-45
Interface Related Features
Keyboard Wedge/USB Keyboard — cont.
Keyboard Simulation
This feature does not apply to the USB Keyboard interface.
NOTE
All PCs check the keyboard status during the power-on Selftest. It is recommended that you enable this function if you are working without a keyboard installation. It simulates keyboard timing and passes the keyboard status to the PC during power-on.
Control Characters
Specifies how the scanner transmits ASCII control characters to the host.
Choices are:
• Disable Control Characters
• Enable transmission of control characters to host
• Send characters between 00H and 1FH according to a special function-key mapping table. (This is used to send keys that are not in the normal ASCII set; a unique set is provided for each available scancode set. Reference
Appendix E, Keyboard Function Key Mappings
3-46 PowerScan® 7000 SRI
Interface Features
Keyboard Wedge/USB Keyboard — cont.
START
STATE BAR CODE
Disable
Keyboard
Simulation
Enable
Keyboard
Simulation
Disable
Control
Characters
Enable
Transmission of
Control
Characters
Enable
Function Key
Mapping
END
User Manual 3-47
Interface Related Features
Keyboard Wedge/USB Keyboard — cont.
Wedge Quiet Interval
This feature does not apply to the USB Keyboard interface.
NOTE
Quiet Interval is the amount of time to look for keyboard activity before the scanner breaks the keyboard connection in order to transmit data to the host..
START
MODE BAR CODE
Selectable from 000 (no interval) to 255 in 10 msec increments. To configure this feature, scan the
“START” bar code above to place the unit in Programming Mode, then the
bar code followed by the three digits (zero
padded) from the Alphanumeric table in
representing your desired length. Exit programming mode by scanning the “END” BAR CODE below
DEFAULT SETTING FOR THIS FEATURE:
010 (100 msec)
Set Wedge
Quiet Interval
END
3-48 PowerScan® 7000 SRI
Interface Features
Keyboard Wedge/USB Keyboard — cont.
Intercharacter Delay
START
MODE BAR CODE
One-half of the delay specified below is inserted between scancodes within each character. If the transmission speed is too high, the system may not be able to receive all characters. You may need to adjust the delay to make the system work properly.
Selectable delay from 00 to 99 in 10msec increments.
To configure this feature, scan the “START” bar code above to place the unit in Programming Mode, then the “Set Intercharacter Delay,” followed by the two digits (zero padded) from the Alphanumeric table in
your desired length. Exit programming mode by scanning the “END” BAR CODE below
DEFAULT SETTING FOR THIS FEATURE:
01 (10 mSec Delay)
Set
Intercharacter
Delay
END
User Manual 3-49
Interface Related Features
NOTES
3-50 PowerScan® 7000 SRI
Chapter 4
Data Editing
Data Editing Overview
It is not recommended to use these features with IBM or Wand Emulation interfaces.
CAUTION
When a bar code is scanned, additional information can be sent to the host computer along with the bar code data. This combination of bar code data and supplementary user-defined data is called a “message string.” The features in this chapter can be used to build specific user-defined data into a message string.
There are several types of selectable data characters that can be sent before and after scanned data. You can specify if they should be sent
with all symbologies, or only with specific symbologies.
shows the available elements you can add to a message string:
Figure 4-1. Breakdown of a Message String
Label ID Transmission:
Enable this option to transmit the Label ID you configure for the scanned symbology.
OR...
Prefix Label ID AIM ID Bar Code Data Label ID Suffix
AIM ID: This function is used to identify and display the common label identifier for its symbology. When enabled, this ID code will be transmitted before the scanned bar code data.
00 - 20 Characters (ASCII)
User Manual 4-1
Data Editing
Please Keep In Mind...
• Modifying a message string is not a mandatory requirement. Data editing is sophisticated feature allowing highly customizable output for advanced users. Factory default settings for data editing is typically set to NONE.
• A prefix or suffix may be applied (reference the
ter for these settings) across all symbologies (set via the Global features in this chapter).
• You can add any character from the
ASCII Chart
(from 00-FF) on the inside back cover of this manual as a prefix, suffix or Label ID.
• Enter prefixes and suffixes in the order in which you want them to appear on the output.
Global Prefix/Suffix
Up to 20 ASCII characters may be added as a prefix (in a position before the bar code data) and/or as a suffix (in a position following the bar code data) as indicated in
.
Figure 4-2. Prefix and Suffix Positions
OR...
Prefix Label ID AIM ID Bar Code Data
00 - 20 Characters (ASCII)
AND
OR
Label ID Suffix
4-2 PowerScan® 7000 SRI
Global Prefix/Suffix
Global Prefix/Suffix — continued
Example: Setting a Prefix
In this example, we’ll set a prefix for all symbologies.
1. Determine which ASCII character(s) are to be added to scanned bar code data. In this example, we’ll add a dollar sign (‘$’) as a prefix.
2. Scan the START bar code.
3. Scan the SET PREFIX bar code.
4. Reference the
ASCII Chart
on the inside back cover of this manual, to find the hex value assigned to the desired character. The corresponding hex number for the ‘$’ character is 24. To enter this selection code, scan the ‘2’ and ‘4’ bar codes from
5. Scan the END bar code to exit Programming Mode.
If less than the expected string of 20 characters are selected, scan the END bar code twice to accept the selections and exit Programming Mode.
NOTE
6. The resulting message string would appear as follows:
Scanned bar code data: 12345
Resulting message string output: $12345
User Manual 4-3
Data Editing
Global Prefix/Suffix — continued
START
MODE BAR CODE
Sets up to 20 characters each from the set of ASCII characters or any hex value from 0 to FF. To configure this feature, scan the “START” bar code above to place the unit in Programming Mode, then the “Set
Prefix” or “Set Suffix,” followed by the digits (in hex) from the Alphanumeric table in
representing your desired charac-
ter(s). Reference the section,
, for more information. Exit programming mode by scanning the “END” BAR CODE below (scan
“END” twice if less than 20 characters have been selected).
DEFAULT SETTING FOR THIS FEATURE:
00 (None) for Prefix
OD (CR) for Suffix
Set Prefix
Set Suffix
END
4-4 PowerScan® 7000 SRI
AIM ID
AIM ID
AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned bar code data.
AIM label identifiers consist of three characters as follows:
• A close brace character (ASCII ‘]’), followed by...
• A code character (see the table below), followed by
• A modifier character (the modifier character is symbol dependent)
SYMBOLOGY CHAR SYMBOLOGY
UPC/EAN
Code 39
Codabar
E
A
F
Interleaved.2 of 5
Code 93
I
G
Code 128/EAN 128 C a. ISBN (X with a 0 modifier character)
MSI/Plessey
PDF 417 & Micro PDF 417
RSS (RSS-14, RSS
Expanded
Standard 2 of 5
ISBN
CHAR
M
L e
S
X a
Figure 4-3. AIM ID
Prefix Label ID AIM ID Bar Code Data Label ID Suffix
User Manual 4-5
Data Editing
AIM ID — continued
START
STATE BAR CODE
Disable AIM ID
Enable AIM ID
END
4-6 PowerScan® 7000 SRI
Label ID
Label ID
A Label ID is a customizable code of up to two ASCII characters (00-
FF), used to identify a bar code (symbology) type. It can be appended previous to or following the transmitted bar code data depending upon how this option is enabled. This feature provides options for configuring custom Label IDs individually per symbology. If you wish to program the scanner to always include an industry standard label identifier for
ALL symbology types, see the previous feature,
.
To configure a Label ID:
1. Scan the START bar code.
2. Select Label ID position as either BEFORE or AFTER by scanning the appropriate bar code.
3. Scan a bar code to select the symbology for which you wish to configure a custom Label ID.
4. Determine the desired character(s) (you may choose either one or two) which will represent the Label ID for the selected symbology.
Next, turn to the
ASCII Chart
on the inside back cover of this manual and find the equivalent hex digits associated with your choice of Label ID. For example, if you wish to select an equal sign (=) as a Label ID, the chart indicates its associated hex characters as 3D.
and scan the bar codes representing the hex characters determined in the previous step. For the example given, the characters ‘0’, ‘0’, ‘3’ and ‘D’ would be scanned. The two zeros scanned (‘0’, ‘0’) represent a selection of
“no character,” since this option allows for two Label ID characters. (Pad with zeros to enter four hex characters.)
6. Scan the END bar code to exit programming mode.
Figure 4-4. Label ID Position Options
Prefix Label ID Aim ID
OR
Bar Code Data Label ID Suffix
User Manual 4-7
Data Editing
Label ID — continued
START
OPTION
Label ID
Transmission:
Disable
BAR CODE
Label ID
Position:
Before Bar
Code Data
Label ID
Position: After
Bar Code Data
Set UPC-A
Label ID
Character(s)
DEFAULT SETTING FOR THIS FEATURE: A (41 hex)
Set UPC-A w/P2 Addon
Label ID
Character(s) DEFAULT SETTING FOR THIS FEATURE: A (41 hex)
Set UPC-A w/P5 Addon
Label ID
Character(s)
DEFAULT SETTING FOR THIS FEATURE: A (41 hex)
4-8 PowerScan® 7000 SRI
Label ID — continued
START
OPTION BAR CODE
Set UPC-A w/C128 Addon
Label ID
Character(s) DEFAULT SETTING FOR THIS FEATURE: A (41 hex)
Label ID
Set UPC-E
Label ID
Character(s)
DEFAULT SETTING FOR THIS FEATURE: E (45 hex)
Set UPC-E w/P2 Addon
Label ID
Character(s)
DEFAULT SETTING FOR THIS FEATURE: E (45 hex)
Set UPC-E w/P5 Addon
Label ID
Character(s)
DEFAULT SETTING FOR THIS FEATURE: E (45 hex)
Set UPC-E w/C128 Addon
Label ID
Character(s) DEFAULT SETTING FOR THIS FEATURE: E (45 hex)
Set EAN-8
Label ID
Character(s)
DEFAULT SETTING FOR THIS FEATURE: FF
(4646 hex)
Set EAN-8 w/P2 Addon
Label ID
Character(s)
DEFAULT SETTING FOR THIS FEATURE:
FF (4646 hex)
User Manual 4-9
Data Editing
Label ID — continued
START
OPTION
Set EAN-8 w/P5 Addon
Label ID
Character(s)
BAR CODE
DEFAULT SETTING FOR THIS FEATURE:
FF (4646 hex)
Set EAN-8 w/C128 Addon
Label ID
Character(s)
DEFAULT SETTING FOR THIS FEATURE:
FF (4646 hex)
Set EAN-13
Label ID
Character(s)
DEFAULT SETTING FOR THIS FEATURE: F (46 hex)
Set EAN-13 w/P2 Addon
Label ID
Character(s) DEFAULT SETTING FOR THIS FEATURE: F (46 hex)
Set EAN-13 w/P5 Addon
Label ID
Character(s) DEFAULT SETTING FOR THIS FEATURE: F (46 hex)
Set EAN-13 w/C128 Addon
Label ID
Character(s) DEFAULT SETTING FOR THIS FEATURE: F (46 hex)
Set ISBN
Label ID
Character(s)
DEFAULT SETTING FOR THIS FEATURE: I (49 hex)
4-10 PowerScan® 7000 SRI
Label ID — continued
START
OPTION BAR CODE
Set GTIN
Label ID
Character(s)
DEFAULT SETTING FOR THIS FEATURE: G (47 hex)
Label ID
Set GTIN w/P2 addon
Label ID
Character(s)
DEFAULT SETTING FOR THIS FEATURE:
G2 (4732 hex)
Set GTIN w/P5 addon
Label ID
Character(s)
DEFAULT SETTING FOR THIS FEATURE:
G5 (4735 hex)
Set GTIN w/C128 addon
Label ID
Character(s)
DEFAULT SETTING FOR THIS FEATURE:
G8 (4738 hex)
Set RSS-14
Label ID
Character(s)
DEFAULT SETTING FOR THIS FEATURE: R4
(5234 hex)
Set RSS-14
Composite
Label ID
Character(s)
DEFAULT SETTING FOR THIS FEATURE:
5234 Hex (R4)
User Manual 4-11
Data Editing
Label ID — continued
START
OPTION
Set RSS
Expanded
Label ID
Character(s)
BAR CODE
DEFAULT SETTING FOR THIS FEATURE: RX
(5258 hex)
Set RSS
Expanded
Composite
Label ID
Character(s)
DEFAULT SETTING FOR THIS FEATURE:
5258 Hex (RX)
Set RSS
Limited
Label ID
Character(s)
DEFAULT SETTING FOR THIS FEATURE:
524C Hex (RL)
Set RSS
Limited
Composite
Label ID
Character(s)
DEFAULT SETTING FOR THIS FEATURE:
524C Hex (RL)
Set Code 39
Label ID
Character(s)
DEFAULT SETTING FOR THIS FEATURE:
* (2A hex)
4-12 PowerScan® 7000 SRI
Label ID — continued
START
OPTION BAR CODE
Set
Pharmacode 39
Label ID
Character(s)
DEFAULT SETTING FOR THIS FEATURE: A (41 hex)
Label ID
Set Code 128
Label ID
Character(s)
DEFAULT SETTING FOR THIS FEATURE: # (23 hex)
Set I 2 of 5
Label ID
Character(s)
DEFAULT SETTING FOR THIS FEATURE: i (69 hex)
Set
Codabar
Label ID
Character(s)
DEFAULT SETTING FOR THIS FEATURE: % (25 hex)
Set
Code 93 Label
ID
Character(s)
DEFAULT SETTING FOR THIS FEATURE: & (26 hex)
Set
Code 11 Label
ID
Character(s)
DEFAULT SETTING FOR THIS FEATURE:
4345 Hex (CE)
User Manual 4-13
Data Editing
Label ID — continued
START
OPTION BAR CODE
Set
MSI/Plessey
Label ID
Character(s)
DEFAULT SETTING FOR THIS FEATURE:
@ (40 hex)
Set
Std 2 of 5
Label ID
Character(s)
DEFAULT SETTING FOR THIS FEATURE: i (69 hex)
Set
PDF 417
Label ID
Character(s)
DEFAULT SETTING FOR THIS FEATURE: P (50 hex)
Set
Micro PDF 417
Label ID
Character(s) DEFAULT SETTING FOR THIS FEATURE: 6D50 Hex
(mP)
END
4-14 PowerScan® 7000 SRI
Label ID
Case Conversion
This feature can convert scanned bar code data to either all lower case or all upper case characters.
Case conversion affects ONLY scanned bar code data, and does not affect Label ID, Prefix, Suffix, or other appended data.
NOTE
START
MODE BAR CODE
Disable
Convert to
Upper Case
Convert to
Lower Case
END
User Manual 4-15
Data Editing
Character Conversion
Character conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted. The second character in the pair is the character to convert to. If the character to convert in a pair is
FF, then no conversion is done.
For example, if you have the character conversion configuration item set to the following:
41423132FFFFFFFF
The first pair is
4142 or AB (41 hex is an ASCII capital A, 42 hex is an
ASCII capital B) and the second pair is
3132 or 12 (31 hex is an ASCII
1,
32 is an ASCII 2). The other two pairs are FFFF and FFFF.
With the label, AB12BA21, it would look as follows after the character conversion: BB22BB22.
The A characters were converted to B characters and the 1 characters were converted to 2 characters. Nothing is done with the last two character pairs, since they are all
FF.
To set Character Conversion:
1. Scan the START bar code.
2. Scan the Character Conversion bar code.
3. Determine the desired string. Sixteen positions must be determined as in the above example. Next, turn to the
ASCII Chart
on the inside back cover of this manual and find the equivalent hex digits needed to fulfill the string.
and scan the bar codes representing the hex characters determined in the previous step.
5. Scan the END bar code to exit Programming Mode.
If less than the expected string of 16 characters are selected, scan the END bar code twice to accept the selections and exit Programming Mode.
NOTE
Scan the END bar code to exit programming mode.
4-16 PowerScan® 7000 SRI
Label ID
Character Conversion — continued
START
MODE BAR CODE
Character
Conversion
DEFAULT SETTING FOR THIS FEATURE:
FFFFFFFFFFFFFFFF hex (no conversion)
END
User Manual 4-17
Data Editing
NOTES
4-18 PowerScan® 7000 SRI
C h a p t e r 5
Symbologies
The scanner supports the following symbologies (bar code types).
Options for each symbology are included in this chapter.
·
·
·
·
·
·
·
·
·
2D Symbologies
Factory Defaults —
are indicated in bold text and are highlighted with yellow throughout this section.
User Manual 5-1
Symbologies
UPC-A
The following options apply to the UPC-A symbology.
Disable/Enable UPC-A
When disabled, the scanner will not read UPC-A bar codes.
Check Digit Transmission
Enable this option to transmit the check digit along with UPC-A bar code data.
Expand UPC-A to EAN-13
Expands UPC-A data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13.
System Number Transmission
This feature enables/disables transmission of UPC-A System Number.
5-2 PowerScan® 7000 SRI
UPC-A — continued
START
STATE
Disable UPC-A
BAR CODE
Enable UPC-A
Don’t Send
Check Digit
Send
Check Digit
Don’t Expand to EAN-13
Expand to
EAN-13
User Manual
UPC-A
5-3
Symbologies
UPC-A — continued
START
STATE
Disable System Number
Transmission
BAR CODE
Enable System
Number Transmission
END
5-4 PowerScan® 7000 SRI
UPC-A
UPC-A — continued
UPC-A Minimum Reads
This feature specifies the minimum number of consecutive times a UPC-
A label must be decoded before it is accepted as good read.
START
READS
Minimum =
1 Read
BAR CODE
Minimum =
2 Reads
Minimum =
3 Reads
Minimum =
4 Reads
END
User Manual 5-5
Symbologies
UPC-A — continued
In-store Minimum Reads
This feature specifies the minimum number of consecutive times an instore printed label must be decoded before it is accepted as good read.
START
READS
Minimum =
1 Read
BAR CODE
Minimum =
2 Reads
Minimum =
3 Reads
Minimum =
4 Reads
END
5-6 PowerScan® 7000 SRI
UPC-A
UPC-A — continued
Add-On Timer
This feature sets the period of time after a UPC-A label is decoded when optional add-on reading is enabled.
START
STATE BAR CODE
This item is used to set the timer value when optional add-ons are enabled. The selectable range is from
010 to 300 mSec in 10 mSec increments. To configure this feature, scan the “START” bar code above to place the unit in Programming Mode, then the “Add-
On Timer,” followed by the three digits (zero padded) from the Alphanumeric table in
representing the disired timer setting.
Exit programming mode by scanning the “END” bar code below.
Add-On Timer
DEFAULT SETTING FOR THIS FEATURE:
007 (70 milliseconds)
END
User Manual 5-7
Symbologies
UPC-E
The following options apply to the UPC-E symbology.
Disable/Enable UPC-E
When disabled, the scanner will not read UPC-E bar codes.
Check Digit Transmission
Enable this option to transmit the check digit along with UPC-E bar code data.
System Number
The System Number (SN) which is usually a zero (0) in the leading position can be optionally included (or not) with scanned bar code data.
Expand UPC-E to UPC-A
Enables/disables expansion of UPC-E labels to UPC-A.
Expand UPC-E to EAN13
Adds a leading zero to a UPC-E bar code which ‘expands’ the data to the
EAN-13 data format. Selecting this feature also changes the symbology
ID to match those required for EAN-13.
5-8 PowerScan® 7000 SRI
UPC-E
UPC-E — continued
START
STATE BAR CODE
Disable UPC-E
Enable UPC-E
Don’t Send
Check Digit
Send
Check Digit
Exclude System Number
Include System
Number
User Manual 5-9
Symbologies
UPC-E — continued
START
STATE BAR CODE
Don’t Expand
UPC-E to
UPC-A
Expand UPC-E to UPC-A
Don’t Expand
UPC-E to
EAN-13
Expand UPC-E to EAN-13
END
5-10 PowerScan® 7000 SRI
UPC-E
UPC-E — continued
Minimum Reads
This feature specifies the minimum number of consecutive times a UPC-
E label must be decoded before it is accepted as good read.
START
READS
Minimum =
1 Read
BAR CODE
Minimum =
2 Reads
Minimum =
3 Reads
Minimum =
4 Reads
END
User Manual 5-11
Symbologies
GTIN
The following options apply to the GTIN label data format.
Disable/Enable GTIN
When this feature is enabled, the scanner will translate UPC/EAN labels to the 14 digit GTIN format.
START
STATE BAR CODE
Disable GTIN
Enable GTIN
END
5-12 PowerScan® 7000 SRI
EAN-13
EAN-13
The following options apply to the EAN-13 symbology.
Disable/Enable EAN-13
When disabled, the scanner will not read EAN-13 bar codes.
Check Digit Transmission
Enable this option to transmit the check digit along with EAN-13 bar code data.
EAN-13 Flag 1 Character
Enables/disables transmission of an EAN/JAN13 Flag1 character.
ISBN
When enabled, this feature truncates the leading three digits from labels that contain ISBN (International Standard Book Number). These codes are used for books and magazines. Labels with ISBN codes start with
"978".
Example:
Bar code data:
Output:
“9789572222720”
“9572222724”
User Manual 5-13
Symbologies
EAN-13 — continued
START
STATE BAR CODE
Disable EAN-13
Enable EAN-13
Don’t Send
Check Digit
Send
Check Digit
Don’t Transmit
EAN-13 Flag 1
Char
Transmit
EAN-13 Flag 1
Char
5-14 PowerScan® 7000 SRI
EAN-13 — continued
START
STATE BAR CODE
Disable ISBN
Enable ISBN
END
EAN-13
User Manual 5-15
Symbologies
EAN-13 — continued
Minimum Reads
This feature specifies the minimum number of consecutive times an
EAN-13 label must be decoded before it is accepted as good read.
START
READS
Minimum =
1 Read
BAR CODE
Minimum =
2 Reads
Minimum =
3 Reads
Minimum =
4 Reads
END
5-16 PowerScan® 7000 SRI
Enable EAN-8
Don’t Send
Check Digit
Send
Check Digit
END
User Manual
EAN-8
EAN-8
The following options apply to the EAN-8 symbology.
Disable/Enable EAN-8
When disabled, the scanner will not read EAN-8 bar codes.
Check Digit Transmission
Enable this option to transmit the check Digit along with EAN-8 bar code data.
START
STATE
Disable EAN-8
BAR CODE
5-17
Symbologies
EAN-8 — continued
Expand EAN-8 to EAN-13 —
Expands EAN-8 data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13.
START
STATE
Don’t Expand to EAN-13
BAR CODE
Expand to
EAN-13
END
5-18 PowerScan® 7000 SRI
EAN-8
EAN-8 — continued
Minimum Reads
This feature specifies the minimum number of consecutive times an
EAN-8 label must be decoded before it is accepted as good read.
START
READS
Minimum =
1 Read
BAR CODE
Minimum =
2 Reads
Minimum =
3 Reads
Minimum =
4 Reads
END
User Manual 5-19
Symbologies
Add-ons
Add-ons (or supplemental characters) are commonly added to the end of
UPC/EAN bar codes. The scanner will read the add-ons if they are enabled and in the field of view. Three add-on types are supported: 2digit, 5-digit and Code 128 add-ons. Supported options are:
None —
This option directs the scanner to ignore add-on portion of a
UPC/EAN bar code but still read the main portion of the bar code.
2 Digits —
The scanner will optionally read 2-digit add-ons with the
UPC/EAN label.
5 Digits —
The scanner will optionally read 5-digit add-ons with the
UPC/EAN label.
Code 128 Add-on —
The scanner will optionally read Code 128 addons with the UPC/EAN label.
NOTE
Contact Customer Support for advanced programming of optional and conditional add-ons.
5-20 PowerScan® 7000 SRI
Add-ons — continued
START
STATE
Disable
Optional 2-
Digit Add-ons
BAR CODE
Enable Optional
2-Digit Add-ons
Disable
Optional 5-
Digit Add-ons
Enable Optional
5-Digit Add-ons
Disable
Optional Code
128 Add-ons
Enable Optional
Code 128
Add-ons
END
User Manual
Add-ons
5-21
Symbologies
RSS-14
The following options apply to the RSS-14 symbology.
Disable/Enable RSS-14
When this feature is disabled, the scanner will not read RSS-14 bar codes.
UCC/EAN 128 Emulation
When enabled, RSS-14 bar codes will be translated to the UCC/EAN
128 label data format.
5-22 PowerScan® 7000 SRI
RSS-14 — continued
START
STATE
Disable
RSS-14
BAR CODE
Enable RSS-14
Disable
UCC/EAN 128
Emulation
Enable
UCC/EAN 128
Emulation
END
RSS-14
User Manual 5-23
Symbologies
RSS-14 — continued
Minimum Reads
This feature specifies the minimum number of consecutive times an
RSS-14 label must be decoded before it is accepted as good read.
START
READS
Minimum =
1 Read
BAR CODE
Minimum =
2 Reads
Minimum =
3 Reads
Minimum =
4 Reads
END
5-24 PowerScan® 7000 SRI
RSS-14
RSS-14 — continued
RSS-14 2D Component
This feature controls the requirement that a 2D label component be decoded when an RSS-14 base label is decoded.
• Enable — Requires that a 2D label component be decoded when an RSS-14 base label is decoded.
• Disable — Does NOT require a 2D label component to be decoded when an RSS-14 base label is decoded.
START/END
STATE
Disable
RSS-14 2D
Component
BAR CODE
Enable RSS-14
2D Component
User Manual 5-25
Enable RSS
Expanded
Disable
UCC/EAN 128
Emulation
Enable
UCC/EAN 128
Emulation
END
5-26
Symbologies
RSS Expanded
The following options apply to the RSS Expanded symbology.
Disable/Enable RSS Expanded
When this feature is disabled, the scanner will not read RSS Expanded bar codes.
UCC/EAN 128 Emulation
When enabled, RSS Expanded bar codes will be translated to the UCC/
EAN 128 label data format.
START
STATE
Disable
RSS Expanded
BAR CODE
PowerScan® 7000 SRI
RSS Expanded
RSS Expanded — continued
Length Control
Fixed Length Decoding —
When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.
Variable Length Decoding —
When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length.
Configuring Fixed Length Decoding:
1. Scan the START bar code.
2. Scan the Fixed Length Decoding bar code.
3. Scan the END bar code.
4. Set Length 1 to the first fixed length by following the
Expanded Length 1, Length 2 Programming Instructions
5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the
below.
Configuring Variable Length Decoding:
1. Scan the START bar code.
2. Scan the Variable Length Decoding bar code.
3. Scan the END bar code.
4. Set Length 1 to the minimum length by following the
Expanded Length 1, Length 2 Programming Instructions
5. Set Length 2 to the maximum length by following the
Expanded Length 1, Length 2 Programming Instructions
User Manual 5-27
Symbologies
RSS Expanded — continued
START
MODE
Variable
Length
Decoding
BAR CODE
Fixed Length
Decoding
END
5-28 PowerScan® 7000 SRI
RSS Expanded
RSS Expanded — continued
RSS Expanded Length 1, Length 2 Programming Instructions
1. Scan the START bar code.
2. Scan either the Set Length 1 or Set Length 2 bar code.
and scan the three digits
(zero padded) representing the length in decimal notation.
For RSS Expanded bar codes, only the data characters are included in the length calculations.
NOTE
4. Scan the END bar code.
START
SETTING BAR CODE
Set Length 1
DEFAULT SETTING FOR THIS FEATURE: 001
Set Length 2
DEFAULT SETTING FOR THIS FEATURE:
074 decimal
END
User Manual 5-29
Symbologies
RSS Expanded — continued
Minimum Reads
This feature specifies the minimum number of consecutive times an RSS
Expanded label must be decoded before it is accepted as good read.
START
READS
Minimum =
1 Read
BAR CODE
Minimum =
2 Reads
Minimum =
3 Reads
Minimum =
4 Reads
END
5-30 PowerScan® 7000 SRI
RSS Expanded
RSS Expanded — continued
RSS Expanded 2D Component
This feature controls the requirement that a 2D label component be decoded when an RSS Expanded base label is decoded.
• Enable — Requires that a 2D label component be decoded when an RSS Expanded base label is decoded.
• Disable — Does NOT require a 2D label component to be decoded when an RSS Expanded base label is decoded.
START/END
STATE
Disable
RSS Expanded
2D Component
BAR CODE
Enable RSS
Expanded 2D
Component
User Manual 5-31
Symbologies
RSS Limited
The following options apply to the RSS Limited symbology.
Disable/Enable RSS Limited
When this feature is disabled, the scanner will not read RSS Limited bar codes.
UCC/EAN 128 Emulation
When enabled, RSS Limited bar codes will be translated to the UCC/
EAN 128 label data format.
START/END
STATE
Disable
RSS Limited
BAR CODE
Enable RSS
Limited
Disable
UCC/EAN 128
Emulation
Enable
UCC/EAN 128
Emulation
5-32 PowerScan® 7000 SRI
RSS Limited
RSS Limited — continued
Minimum Reads
This feature specifies the minimum number of consecutive times an RSS
Limited label must be decoded before it is accepted as good read.
START/END
READS
Minimum =
1 Read
BAR CODE
Minimum =
2 Reads
Minimum =
3 Reads
Minimum =
4 Reads
User Manual 5-33
Symbologies
RSS Limited — continued
RSS Limited 2D Component
This feature controls the requirement that a 2D label component be decoded when an RSS Limited base label is decoded.
• Enable — Requires that a 2D label component be decoded when an RSS Limited base label is decoded.
• Disable — Does NOT require a 2D label component to be decoded when an RSS Limited base label is decoded.
START/END
STATE
Disable
RSS Limited
2D Component
BAR CODE
Enable RSS
Limited 2D
Component
5-34 PowerScan® 7000 SRI
Code 39
Code 39
The following options apply to the Code 39 symbology.
Disable/Enable Code 39
When this feature is disabled, the scanner will not read Code 39 bar codes.
Check Character Calculation
When enabled, the scanner will calculate the check character of the labels. Turn this option on only when a checksum is present in the Code
39 labels.
Check Character Transmit
Enable this option to transmit the check character with scanned bar code data.
Start/Stop Characters
Enables/disables transmission of Code39 start and stop characters.
Code 39 Full ASCII
Enables/disables the translation of Code 39 characters to Code 39 full-
ASCII characters
User Manual 5-35
Symbologies
Code 39 — continued
START
STATE BAR CODE
Disable
Code 39
Enable
Code 39
Disable
Check Char
Calculation
Enable
Check Char
Calculation
Disable
Check Char
Transmission
Enable
Check Char
Transmission
5-36 PowerScan® 7000 SRI
Code 39 — continued
START
STATE
Don’t Transmit
Start/Stop
Characters
BAR CODE
Transmit
Start/Stop
Characters
Disable
Code 39 Full
ASCII
Enable
Code 39 Full
ASCII
END
Code 39
User Manual 5-37
Symbologies
Code 39 — continued
Length Control
Fixed Length Decoding —
When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.
Variable Length Decoding —
When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length.
Configuring Fixed Length Decoding:
1. Scan the START bar code.
2. Scan the Fixed Length Decoding bar code.
3. Scan the END bar code.
4. Set Length 1 to the first fixed length by following the
Length 1, Length 2 Programming Instructions
below.
5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the
Code 39 Length 1, Length 2 Programming Instructions
below.
Configuring Variable Length Decoding:
1. Scan the START bar code.
2. Scan the Variable Length Decoding bar code.
3. Scan the END bar code.
4. Set Length 1 to the minimum length by following the
Length 1, Length 2 Programming Instructions
below.
5. Set Length 2 to the maximum length by following the
Length 1, Length 2 Programming Instructions
below.
5-38 PowerScan® 7000 SRI
Code 39 — continued
START
MODE
Variable
Length
Decoding
BAR CODE
Fixed Length
Decoding
END
Code 39
User Manual 5-39
Symbologies
Code 39 Length 1, Length 2 Programming
Instructions
1. Scan the START bar code.
2. Scan either the Set Length 1 or Set Length 2 bar code.
and scan the three digits
(zero padded) representing the length in decimal notation.
For Code 39 bar codes, all check, data and full ASCII shift characters are included in the length calculations.
Start/Stop characters are not included.
NOTE
4. Scan the END bar code.
SETTING BAR CODE
Set Length 1
DEFAULT SETTING FOR THIS FEATURE: 003
Set Length 2
DEFAULT SETTING FOR THIS FEATURE:
050 decimal
END
5-40 PowerScan® 7000 SRI
Code 39
Code 39 — continued
Quiet Zones
This feature enables/disables the requirement that quiet zones must be present for Code 39 bar codes.
START
STATE
Don’t require
Quiet Zones
BAR CODE
Require Quiet
Zones
END
User Manual 5-41
Symbologies
Code 39 — continued
Code 39 Stitching
Enables/disables stitching for Code 39 labels. When parts of a Code 39 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met.
START
STATE
Disable
Code 39
Stitching
BAR CODE
Enable
Code 39
Stitching
END
5-42 PowerScan® 7000 SRI
Code 39
Code 39 — continued
Minimum Reads
This feature specifies the minimum number of consecutive times an
Code 39 label must be decoded before it is accepted as good read.
START
READS
Minimum =
1 Read
BAR CODE
Minimum =
2 Reads
Minimum =
3 Reads
Minimum =
4 Reads
END
User Manual 5-43
Symbologies
Pharmacode 39
The following options apply to the Pharmacode 39 symbology.
Disable/Enable Pharmacode 39
When this feature is disabled, the scanner will not read Pharmacode 39 bar codes.
START
STATE
Disable
Pharmacode
39
Enable
Pharmacode 39
END
BAR CODE
5-44 PowerScan® 7000 SRI
Transmit
Start/Stop
Characters
Disable
Check Char
Transmission
Enable
Check Char
Transmission
END
Pharmacode 39 — continued
Pharmacode 39
Start/Stop Characters
Enables or disables transmission of Pharmacode 39 start/stop characters.
Check Character Transmit
Enable this option to transmit the check character with scanned bar code data.
START
STATE
Don’t Transmit Start/Stop
Characters
BAR CODE
User Manual 5-45
Enable
Code 128
Disable
UCC/EAN 128
Enable
UCC/EAN 128
END
Symbologies
Code 128 and EAN 128
The following options apply to the Code 128 and EAN 128 symbologies.
Code 128 —
When this feature is disabled, the scanner will not read
Code 128 bar codes.
UCC/EAN 128 —
Enables/disables ability of scanner to translate UCC/
EAN 128 labels to the Code 128 data format.
START
STATE
Disable
Code 128
BAR CODE
5-46 PowerScan® 7000 SRI
Code 128 and EAN 128
Code 128 and EAN 128 — continued
Transmit Function Characters
Enables/disables transmission of Code128 function characters 1, 2, 3, and 4.
Function codes are transmitted as follows:
• FNC1 = 80 hex
• FNC2 = 81 hex
• FNC3 = 82 hex
• FNC4 = 83 hex
START
STATE
Don’t Transmit Function
Characters
BAR CODE
Transmit
Function
Characters
END
User Manual 5-47
Symbologies
Code 128 and EAN 128 — continued
Length Control
Fixed Length Decoding —
When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.
Variable Length Decoding —
When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length.
Configuring Fixed Length Decoding:
1. Scan the START bar code.
2. Scan the Fixed Length Decoding bar code.
3. Scan the END bar code.
4. Set Length 1 to the first fixed length by following the
Length 1, Length 2 Programming Instructions
below.
5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the
Code 128 Length 1, Length 2 Programming Instructions
below.
Configuring Variable Length Decoding:
1. Scan the START bar code.
2. Scan the Variable Length Decoding bar code.
3. Scan the END bar code.
4. Set Length 1 to the minimum length by following the
Length 1, Length 2 Programming Instructions
below.
5. Set Length 2 to the maximum length by following the
Length 1, Length 2 Programming Instructions
below.
5-48 PowerScan® 7000 SRI
Code 128 and EAN 128
Code 128 and EAN 128 — continued
START
MODE
Variable
Length
Decoding
BAR CODE
Fixed Length
Decoding
END
User Manual 5-49
Symbologies
Code 128 and EAN 128 — continued
Code 128 Length 1, Length 2 Programming
Instructions
1. Scan the START bar code.
2. Scan either the Set Length 1 or Set Length 2 bar code.
and scan the three digits
(zero padded) representing the length in decimal notation.
For Code 128 bar codes, only the data characters are included in the length calculations.
NOTE
4. Scan the END bar code.
SETTING BAR CODE
Set Length 1
DEFAULT SETTING FOR THIS FEATURE: 001
Set Length 2
DEFAULT SETTING FOR THIS FEATURE:
080 decimal
END
5-50 PowerScan® 7000 SRI
Code 128 and EAN 128
Code 128 and EAN 128 — continued
Code 128 Stitching
Enables/disables stitching for Code 128 labels. When parts of a Code
128 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met.
START
STATE
Disable
Code 128
Stitching
BAR CODE
Enable
Code 128
Stitching
END
User Manual 5-51
Symbologies
Code 128 and EAN 128 — continued
Minimum Reads
This feature specifies the minimum number of consecutive times an
Code 128 label must be decoded before it is accepted as good read.
START
READS
Minimum =
1 Read
BAR CODE
Minimum =
2 Reads
Minimum =
3 Reads
Minimum =
4 Reads
END
5-52 PowerScan® 7000 SRI
Interleaved 2 of 5
Interleaved 2 of 5
The following options apply to the Interleaved 2 of 5 (I 2 of 5) symbology.
Disable/Enable Interleaved 2 of 5
When this feature is disabled, the scanner will not read Interleaved 2 of 5 bar codes.
Check Digit Calculation
When enabled, the scanner will calculate the check digit of the labels.
Check Digit Transmit
Enable this option to transmit the check digit with scanned bar code data.
User Manual 5-53
Symbologies
Interleaved 2 of 5 — continued
START
STATE
Disable
Interleaved
2 of 5
BAR CODE
Enable
Interleaved
2 of 5
Disable
Check Digit
Calculation
Enable
Check Digit
Calculation
Disable
Check Digit
Transmission
Enable
Check Digit
Transmission
END
5-54 PowerScan® 7000 SRI
Interleaved 2 of 5
Interleaved 2 of 5 — continued
Length Control
Fixed Length Decoding —
When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.
Variable Length Decoding —
When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length.
Configuring Fixed Length Decoding:
1. Scan the START bar code.
2. Scan the Fixed Length Decoding bar code.
3. Scan the END bar code.
4. Set Length 1 to the first fixed length by following the
Interleaved 2 of 5 Length 1, Length 2 Programming Instructions
below.
5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the
Length 2 Programming Instructions
below.
Configuring Variable Length Decoding:
1. Scan the START bar code.
2. Scan the Variable Length Decoding bar code.
3. Scan the END bar code.
4. Set Length 1 to the minimum length by following the
Interleaved 2 of 5 Length 1, Length 2 Programming Instructions
below.
5. Set Length 2 to the maximum length by following the
Interleaved 2 of 5 Length 1, Length 2 Programming Instructions
below.
User Manual 5-55
Symbologies
Interleaved 2 of 5 — continued
START
MODE
Variable
Length
Decoding
BAR CODE
Fixed Length
Decoding
END
5-56 PowerScan® 7000 SRI
Interleaved 2 of 5
Interleaved 2 of 5 — continued
Interleaved 2 of 5 Length 1, Length 2 Programming Instructions
1. Scan the START bar code.
2. Scan either the Set Length 1 or Set Length 2 bar code.
and scan the three digits representing the length in decimal notation
.
For Interleaved 2 of 5 bar codes, lengths must be an even number. Additionally, all check and data characters are included in the length calculations.
NOTE
4. Scan the END bar code.
START
SETTING BAR CODE
Set Length 1
DEFAULT SETTING FOR THIS FEATURE: 006
Set Length 2
DEFAULT SETTING FOR THIS FEATURE:
050 decimal
END
User Manual 5-57
Symbologies
Interleaved 2 of 5 — continued
Interleaved 2 of 5 Stitching
Enables/disables stitching for Interleaved 2 of 5 labels. When parts of an
Interleaved 2 of 5 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met.
START
STATE
Disable
Interleaved 2 of 5
Stitching
BAR CODE
Enable Interleaved 2 of 5
Stitching
END
5-58 PowerScan® 7000 SRI
Interleaved 2 of 5
Interleaved 2 of 5 — continued
Minimum Reads
This feature specifies the minimum number of consecutive times an
Interleaved 2 of 5 label must be decoded before it is accepted as good read.
START
READS
Minimum =
1 Read
BAR CODE
Minimum =
2 Reads
Minimum =
3 Reads
Minimum =
4 Reads
END
User Manual 5-59
Symbologies
Codabar
The following options apply to the Codabar symbology.
Disable/Enable Codabar
When this feature is disabled, the scanner will not read Codabar bar codes.
Check Character Verification
When enabled, the scanner will verify the check character of the labels.
Check Character Transmit
Enable this option to transmit the check character with scanned bar code data.
5-60 PowerScan® 7000 SRI
Codabar — continued
START
STATE
Disable
Codabar
BAR CODE
Enable
Codabar
Disable
Check Char
Verification
Enable
Check Char
Verification
Disable
Check Char
Transmission
Enable
Check Char
Transmission
END
User Manual
Codabar
5-61
Symbologies
Codabar — continued
Length Control
Fixed Length Decoding —
When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.
Variable Length Decoding —
When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length.
Configuring Fixed Length Decoding:
1. Scan the START bar code.
2. Scan the Fixed Length Decoding bar code.
3. Scan the END bar code.
4. Set Length 1 to the first fixed length by following the
Length 1, Length 2 Programming Instructions
below.
5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the
Codabar Length 1, Length 2 Programming Instructions
below.
Configuring Variable Length Decoding:
1. Scan the START bar code.
2. Scan the Variable Length Decoding bar code.
3. Scan the END bar code.
4. Set Length 1 to the minimum length by following the
Length 1, Length 2 Programming Instructions
below.
5. Set Length 2 to the maximum length by following the
Length 1, Length 2 Programming Instructions
below.
5-62 PowerScan® 7000 SRI
Codabar — continued
START
MODE
Variable
Length
Decoding
BAR CODE
Fixed Length
Decoding
END
Codabar
User Manual 5-63
Symbologies
Codabar — continued
Codabar Length 1, Length 2 Programming
Instructions
1. Scan the START bar code.
2. Scan either the Set Length 1 or Set Length 2 bar code.
and scan the three digits
(zero padded) representing the length in decimal notation.
For Codabar bar codes, all start, stop, check and data characters are included in the length calculations.
NOTE
4. Scan the END bar code.
SETTING BAR CODE
Set Length 1
DEFAULT SETTING FOR THIS FEATURE: 003
Set Length 2
DEFAULT SETTING FOR THIS FEATURE:
050 decimal
END
5-64 PowerScan® 7000 SRI
Codabar
Codabar — continued
Quiet Zones
This feature enable/disables the requirement that quiet zones must be present for Codabar bar codes.
START
STATE
Don’t require
Quiet Zones
BAR CODE
Require Quiet
Zones
END
User Manual 5-65
Symbologies
Codabar — continued
Start/Stop Character Type
Codabar has four pairs of Start/Stop patterns. Select one pair to match your application.
Start/Stop Character Transmission
The transmission of start and end characters of Codabar is selected below.
Start/Stop Character Match
This feature enables/disables the requirement that start and stop characters match
.
5-66 PowerScan® 7000 SRI
Codabar — continued
START
STATE
Start/Stop
Type: ABCD/
TN*E
BAR CODE
Start/Stop
Type: ABCD/
ABCD
Start/Stop
Type: abcd/tn*e
Start/Stop
Type: abcd/ abcd
Disable
Start/Stop Char
Transmission
Enable
Start/Stop
Char
Transmission
User Manual
Codabar
5-67
Symbologies
Codabar — continued
START
STATE
Disable
Start/Stop
Char Match
BAR CODE
Enable
Start/Stop Char
Match
END
5-68 PowerScan® 7000 SRI
Codabar
Codabar — continued
Codabar Stitching
Enables/disables stitching for Codabar labels. When parts of a Codabar label are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met.
START
STATE
Disable
Codabar
Stitching
BAR CODE
Enable
Codabar
Stitching
END
User Manual 5-69
Symbologies
Codabar — continued
Minimum Reads
This feature specifies the minimum number of consecutive times an
Codabar label must be decoded before it is accepted as good read.
START
READS
Minimum =
1 Read
BAR CODE
Minimum =
2 Reads
Minimum =
3 Reads
Minimum =
4 Reads
END
5-70 PowerScan® 7000 SRI
Code 93
Code 93
The following options apply to the Code 93 symbology.
Disable/Enable Code 93
When this feature is disabled, the scanner will not read Code 93 bar codes.
START
STATE
Disable
Code 93
BAR CODE
Enable
Code 93
END
User Manual 5-71
Symbologies
Code 93 — continued
Length Control
Fixed Length Decoding —
When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.
Variable Length Decoding —
When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length.
Configuring Fixed Length Decoding:
1. Scan the START bar code.
2. Scan the Fixed Length Decoding bar code.
3. Scan the END bar code.
4. Set Length 1 to the first fixed length by following the
Length 1, Length 2 Programming Instructions
below.
5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the
Code 93 Length 1, Length 2 Programming Instructions
below.
Configuring Variable Length Decoding:
1. Scan the START bar code.
2. Scan the Variable Length Decoding bar code.
3. Scan the END bar code.
4. Set Length 1 to the minimum length by following the
Length 1, Length 2 Programming Instructions
below.
5. Set Length 2 to the maximum length by following the
Length 1, Length 2 Programming Instructions
below.
5-72 PowerScan® 7000 SRI
Code 93 — continued
START
MODE
Variable
Length
Decoding
BAR CODE
Fixed Length
Decoding
END
Code 93
User Manual 5-73
Symbologies
Code 93 — continued
Code 93 Length 1, Length 2 Programming
Instructions
1. Scan the START bar code.
2. Scan either the Set Length 1 or Set Length 2 bar code.
and scan the three digits
(zero padded) representing the length in decimal notation.
For Code 93 bar codes, only the data characters are included in the length calculations.
NOTE
4. Scan the END bar code.
SETTING BAR CODE
Set Length 1
DEFAULT SETTING FOR THIS FEATURE: 001
Set Length 2
DEFAULT SETTING FOR THIS FEATURE:
050 decimal
END
5-74 PowerScan® 7000 SRI
Code 93
Code 93 — continued
Code 93 Stitching
Enables/disables stitching for Code 93 bar codes. When parts of a Code
93 label are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met.
START
STATE
Disable
Code 93
Stitching
BAR CODE
Enable
Code 93
Stitching
END
User Manual 5-75
Symbologies
Code 93 — continued
Minimum Reads
This feature specifies the minimum number of consecutive times an
Code 93 label must be decoded before it is accepted as good read.
START
READS
Minimum =
1 Read
BAR CODE
Minimum =
2 Reads
Minimum =
3 Reads
Minimum =
4 Reads
END
5-76 PowerScan® 7000 SRI
Code 11
Code 11
The following options apply to the Code 11 symbology.
Disable/Enable Code 11
When this feature is disabled, the scanner will not read Code 11 bar codes.
START/END
STATE
Disable
Code 11
BAR CODE
Enable
Code 11
User Manual 5-77
Symbologies
Code 11 — continued
Number of Check Characters
Specifies the number of Code 11 check characters (one or two) to be calculated and verified.
Check Character Transmit
Enables/disables transmission of Code 11 check characters.
START/END
STATE
One Check
Character
BAR CODE
Two Check
Characters
Disable
Check Char
Transmission
Enable
Check Char
Transmission
5-78 PowerScan® 7000 SRI
Code 11
Code 11 — continued
Length Control
Fixed Length Decoding —
When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.
Variable Length Decoding —
When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length.
Configuring Fixed Length Decoding:
1. Scan the START/END bar code.
2. Scan the Fixed Length Decoding bar code.
3. Scan the START/END bar code.
4. Set Length 1 to the first fixed length by following the
Length 1, Length 2 Programming Instructions
.
5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the
Code 11 Length 1, Length 2 Programming Instructions
Configuring Variable Length Decoding:
1. Scan the START/END bar code.
2. Scan the Variable Length Decoding bar code.
3. Scan the START/END bar code.
4. Set Length 1 to the minimum length by following the
Length 1, Length 2 Programming Instructions
.
5. Set Length 2 to the maximum length by following the
Length 1, Length 2 Programming Instructions
.
User Manual 5-79
Symbologies
Code 11 — continued
START/END
MODE
Variable
Length
Decoding
BAR CODE
Fixed Length
Decoding
5-80 PowerScan® 7000 SRI
Code 11
Code 11 — continued
Code 11 Length 1, Length 2 Programming
Instructions
1. Scan the START/END bar code.
2. Scan either the Set Length 1 or Set Length 2 bar code.
and scan the three digits
(zero padded) representing the length in decimal notation.
For Code 11 bar codes, only the data characters are included in the length calculations.
NOTE
4. Scan the START/END bar code.
START/END
SETTING BAR CODE
Set Length 1
DEFAULT SETTING FOR THIS FEATURE: 004
Set Length 2
DEFAULT SETTING FOR THIS FEATURE:
050 decimal
User Manual 5-81
Symbologies
Code 11 — continued
Minimum Reads
This feature specifies the minimum number of consecutive times an
Code 11 label must be decoded before it is accepted as good read.
START/END
READS
Minimum =
1 Read
BAR CODE
Minimum =
2 Reads
Minimum =
3 Reads
Minimum =
4 Reads
5-82 PowerScan® 7000 SRI
MSI/Plessey
MSI/Plessey
The following options apply to the MSI/Plessey symbology.
Disable/Enable MSI/Plessey
When this feature is disabled, the scanner will not read MSI/Plessey bar codes.
Check Digit Verification
This feature specifies whether one or two check digits are to be calculated and verified.
Check Digit Transmit
When this option is enabled, the scanner will transmit one-digit or twodigit check digits, depending upon the setting for check digit verification.
User Manual 5-83
Symbologies
MSI/Plessey — continued
START
STATE BAR CODE
Disable
MSI/Plessey
Enable
MSI/Plessey
Disable
Check Digit
Verification
Enable
Check Digit
Verification
1-Digit
Check Digit
Verification
2-Digit
Check Digit
Verification
³
5-84 PowerScan® 7000 SRI
MSI/Plessey — continued
START
STATE BAR CODE
Disable
Check Digit
Transmission
Enable
Check Digit
Transmission
END
MSI/Plessey
User Manual 5-85
Symbologies
MSI/Plessey — continued
Length Control
Fixed Length Decoding —
When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.
Variable Length Decoding —
When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length.
Configuring Fixed Length Decoding:
1. Scan the START bar code.
2. Scan the Fixed Length Decoding bar code.
3. Scan the END bar code.
4. Set Length 1 to the first fixed length by following the
Length 1, Length 2 Programming Instructions
below.
5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the
MSI/Plessey Length 1, Length 2
below.
Configuring Variable Length Decoding:
1. Scan the START bar code.
2. Scan the Variable Length Decoding bar code.
3. Scan the END bar code.
4. Set Length 1 to the minimum length by following the
Length 1, Length 2 Programming Instructions
below.
5. Set Length 2 to the maximum length by following the
Length 1, Length 2 Programming Instructions
below.
5-86 PowerScan® 7000 SRI
MSI/Plessey — continued
START
MODE
Variable
Length
Decoding
BAR CODE
Fixed Length
Decoding
END
MSI/Plessey
User Manual 5-87
Symbologies
MSI/Plessey — continued
MSI/Plessey Length 1, Length 2 Programming Instructions
1. Scan the START bar code.
2. Scan either the Set Length 1 or Set Length 2 bar code.
and scan the three digits
(zero padded) representing the length in decimal notation.
For MSI/Plessey bar codes, all check and data characters are included in the length calculations.
NOTE
Scan the END bar code
.
SETTING BAR CODE
Set Length 1
DEFAULT SETTING FOR THIS FEATURE: 004
Set Length 2
DEFAULT SETTING FOR THIS FEATURE:
016 decimal
END
5-88 PowerScan® 7000 SRI
MSI/Plessey
MSI/Plessey — continued
MSI/Plessey Stitching
Enables/disables stitching for MSI/Plessey bar codes. When parts of an
MSI/Plessey label are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met.
START
STATE
Disable
MSI/Plessey
Stitching
BAR CODE
Enable
MSI/Plessey
Stitching
END
User Manual 5-89
Symbologies
MSI/Plessey — continued
Minimum Reads
This feature specifies the minimum number of consecutive times an
MSI/Plessey label must be decoded before it is accepted as good read.
START
READS
Minimum =
1 Read
BAR CODE
Minimum =
2 Reads
Minimum =
3 Reads
Minimum =
4 Reads
END
5-90 PowerScan® 7000 SRI
MSI/Plessey
Standard 2 of 5
The following options apply to the Standard 2 of 5 symbology.
Disable/Enable Standard 2 of 5
When this feature is disabled, the scanner will not read Standard 2 of 5 bar codes.
Check Digit Verification
When enabled, the scanner will verify the check digit of the labels.
Check Digit Transmit
When this option is enabled, the scanner will transmit the check digit.
User Manual 5-91
Symbologies
Standard 2 of 5 — continued
START
STATE BAR CODE
Disable
Std 2 of 5
Enable
Std 2 of 5
Disable
Check Digit
Verification
Enable
Check Digit
Verification
Disable
Check Digit
Transmission
Enable
Check Digit
Transmission
END
5-92 PowerScan® 7000 SRI
MSI/Plessey
Standard 2 of 5 — continued
Length Control
Fixed Length Decoding —
When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.
Variable Length Decoding —
When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length.
Configuring Fixed Length Decoding:
1. Scan the START bar code.
2. Scan the Fixed Length Decoding bar code.
3. Scan the END bar code.
4. Set Length 1 to the first fixed length by following the
5 Length 1, Length 2 Programming Instructions
below.
5. Set Length 2 to the second fixed length (or to ‘000’ if there is only
one fixed length) by following the
Standard 2 of 5 Length 1, Length 2
Configuring Variable Length Decoding:
1. Scan the START bar code.
2. Scan the Variable Length Decoding bar code.
3. Scan the END bar code.
4. Set Length 1 to the minimum length by following the
Standard 2 of 5 Length 1, Length 2 Programming Instructions
below.
5. Set Length 2 to the maximum length by following the
Standard 2 of 5 Length 1, Length 2 Programming Instructions
below.
User Manual 5-93
Symbologies
Standard 2 of 5 — continued
START
MODE
Variable
Length
Decoding
BAR CODE
Fixed Length
Decoding
END
5-94 PowerScan® 7000 SRI
MSI/Plessey
Standard 2 of 5 — continued
Standard 2 of 5 Length 1, Length 2 Programming Instructions
1. Scan the START bar code.
2. Scan either the Set Length 1 or Set Length 2 bar code.
and scan the three digits
(zero padded) representing the length in decimal notation.
For Standard 2 of 5 bar codes, all check and data characters are included in the length calculations.
NOTE
4. Scan the END bar code.
SETTING BAR CODE
Set Length 1
DEFAULT SETTING FOR THIS FEATURE: 008
Set Length 2
DEFAULT SETTING FOR THIS FEATURE:
050 decimal
END
User Manual 5-95
Symbologies
Standard 2 of 5 — continued
Standard 2 of 5 Stitching
Enables/disables stitching for Standard 2 of 5 bar codes. When parts of a
Standard 2 of 5 label are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met.
START
STATE
Disable
Std 2 of 5
Stitching
BAR CODE
Enable
Std 2 of 5
Stitching
END
5-96 PowerScan® 7000 SRI
MSI/Plessey
Standard 2 of 5 — continued
Minimum Reads
This feature specifies the minimum number of consecutive times a Standard 2 of 5 label must be decoded before it is accepted as good read.
START
READS
Minimum =
1 Read
BAR CODE
Minimum =
2 Reads
Minimum =
3 Reads
Minimum =
4 Reads
END
User Manual 5-97
Symbologies
PDF 417
The following options apply to the PDF 417 symbology.
Disable/Enable PDF 417
When this feature is disabled, the scanner will not read PDF 417 bar codes.
START
STATE
Disable
PDF417
BAR CODE
Enable
PDF 417
END
5-98 PowerScan® 7000 SRI
PDF 417
PDF 417 — continued
Length Control
Fixed Length Decoding —
When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.
Variable Length Decoding —
When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length.
Configuring Fixed Length Decoding:
1. Scan the START bar code.
2. Scan the Fixed Length Decoding bar code.
3. Scan the END bar code.
4. Set Length 1 to the first fixed length by following the
Length 1, Length 2 Programming Instructions
below.
5. Set Length 2 to the second fixed length (or to ‘0000’ if there is only one fixed length) by following the
Configuring Variable Length Decoding:
1. Scan the START bar code.
2. Scan the Variable Length Decoding bar code.
3. Scan the END bar code.
4. Set Length 1 to the minimum length by following the
Length 1, Length 2 Programming Instructions
below.
5. Set Length 2 to the maximum length by following the
Length 1, Length 2 Programming Instructions
below.
User Manual 5-99
Symbologies
PDF 417 — continued
START
MODE
Variable
Length
Decoding
BAR CODE
Fixed Length
Decoding
END
5-100 PowerScan® 7000 SRI
PDF 417
PDF 417 — continued
PDF 417 Length 1, Length 2 Programming
Instructions
1. Scan the START bar code.
2. Scan either the Set Length 1 or Set Length 2 bar code.
and scan the three digits
(zero padded) representing the length in decimal notation.
For PDF 417 bar codes, only the data characters are included in the length calculations.
NOTE
Scan the END bar code.
SETTING BAR CODE
Set Length 1
DEFAULT SETTING FOR THIS FEATURE: 001
Set Length 2
DEFAULT SETTING FOR THIS FEATURE:
600 decimal
END
User Manual 5-101
Symbologies
PDF 417 — continued
Minimum Reads
This feature specifies the minimum number of consecutive times a PDF
417 label must be decoded before it is accepted as good read.
START
READS
Minimum =
1 Read
BAR CODE
Minimum =
2 Reads
Minimum =
3 Reads
Minimum =
4 Reads
END
5-102 PowerScan® 7000 SRI
Micro PDF 417
Micro PDF 417
The following options apply to the Micro PDF 417 symbology.
Disable/Enable Micro PDF 417
When this feature is disabled, the scanner will not read Micro PDF 417 bar codes.
START/END
STATE
Disable
Micro PDF417
BAR CODE
Enable
Micro PDF 417
User Manual 5-103
Symbologies
Micro PDF 417 — continued
PDF 128 Emulation
Depending upon the other configuration features listed below, this feature specifies which AIM ID to use for Micro PDF 417 labels when performing EAN 128 or Code 128 emulation.
• If this feature (
is enabled while the scanner is performing EAN 128 or Code
128 emulation for a Micro PDF 417 label, the appropriate EAN
128 or Code 128 AIM ID is appended to the label data.
• If this feature (
) is disabled, and the feature
is enabled while the scanner is performing EAN 128 or Code
128 emulation for a Micro PDF 417 label, the Micro PDF 417
AIM ID is appended to the label data.
• If this feature (
is disabled while the scanner is performing EAN 128 or Code
128 emulation for a Micro PDF 417 label, the label type is changed to either EAN 128 or Code 128 as applicable.
• If this feature (
) is disabled, and the feature
is disabled while the scanner is performing EAN 128 or Code
128 emulation for a Micro PDF 417 label, the label type remains
Micro PDF 417.
START/END
STATE BAR CODE
Disable PDF
128 Emulation
Enable
PDF 128
Emulation
5-104 PowerScan® 7000 SRI
Micro PDF 417
Micro PDF 417 — continued
Length Control
Fixed Length Decoding —
When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.
Variable Length Decoding —
When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length.
Configuring Fixed Length Decoding:
1. Scan the START/END bar code.
2. Scan the Fixed Length Decoding bar code.
3. Scan the START/END bar code.
4. Set Length 1 to the first fixed length by following the
417 Length 1, Length 2 Programming Instructions
.
5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the
Micro PDF 417 Length 1, Length 2
Configuring Variable Length Decoding:
1. Scan the START/END bar code.
2. Scan the Variable Length Decoding bar code.
3. Scan the START/END bar code.
4. Set Length 1 to the minimum length by following the
417 Length 1, Length 2 Programming Instructions
.
5. Set Length 2 to the maximum length by following the
417 Length 1, Length 2 Programming Instructions
.
User Manual 5-105
Symbologies
Micro PDF 417 — continued
START/END
MODE
Variable
Length
Decoding
BAR CODE
Fixed Length
Decoding
5-106 PowerScan® 7000 SRI
Micro PDF 417
Micro PDF 417 — continued
Micro PDF 417 Length 1, Length 2 Programming Instructions
1. Scan the START/END bar code.
2. Scan either the Set Length 1 or Set Length 2 bar code.
and scan the three digits
(zero padded) representing the length in decimal notation.
For Micro PDF 417 bar codes, only the data characters are included in the length calculations.
NOTE
Scan the START/END bar code.
START/END
SETTING BAR CODE
Set Length 1
DEFAULT SETTING FOR THIS FEATURE: 001
Set Length 2
DEFAULT SETTING FOR THIS FEATURE:
366 decimal
User Manual 5-107
Symbologies
Micro PDF 417 — continued
Minimum Reads
This feature specifies the minimum number of consecutive times a
Micro PDF 417 label must be decoded before it is accepted as good read.
START/END
READS
Minimum =
1 Read
BAR CODE
Minimum =
2 Reads
Minimum =
3 Reads
Minimum =
4 Reads
5-108 PowerScan® 7000 SRI
Appendix A
Product Specifications
Optical and Read Performance
Parameters
Parameter Specification
Scanning Width
2” wide at 1” from scanner
6” wide at 7” from scanner
Minimum Resolution
4mil minimum element size
(at some distance, no implied DOF)
5 mil — 3 to 6”/7.6 to 15.2 cm
7.5 mil — 2 to 16”/5.1 to 40.6 cm
10 mil — 1.5 to 22”/3.8 to 55.9 cm
13 mil — 1 to 30”/2.5 to 76.2 cm
20 mil — 1 to 42”/2.5 to 106.7 cm
55 mil — 2 to 80”/5.1 to 203.2 cm Depth of Field
(75% read rate; 90% PCS;
Code 39 with 2.5:1 W/N ratio except for 13 mils)
Minimum distance determined by symbol length and scan angle. Printing resolution, contrast and ambient light dependent.
13 mil DOF based on UPC. All others are Code
39. All labels grade A, minimum illumination:
300 Lux, 20
° C, label perpendicular to the optical axis.
Minimum Print Contrast Ratio
Skew a
(Yaw)
20%
± 60
°
Pitch
± 65
°
Roll
± 40
° a. DOF will be reduced whenever the label is not perpendicular to the optical axis.
User Manual A-1
Physical Properties
Parameter
Dimensions (Typical):
Height
Length
Width
Weight
Voltage Requirements
Specification
7.5”/190 mm
4.5”/115 mm
3.0”/75 mm
10 ounces/284 g (without cable)
+4 to 14 VDC +/- 5%
Electrical Parameters
Parameter
Input Voltage
Input Power
Maximum Operating Power
Typical Operating Power
Typical Standby Power
Input Current
Maximum Operating Current
Typical Operating Current
Typical Standby Current
Sleep Mode Current
2.4 W
1.4 W
1 w
Specification
+4 to 14 VDC
480 mA @ 5VDC
270 mA @ 5VDC
210 mA @ 5VDC
Less than 1 mA
A-2 4600
Environmental Parameters
Environmental Parameters
Parameter
Mechanical Shock
Contaminants
Spray/rain
Dust/particulate
Specification
50 drops from 6.5 feet (2 meters) to concrete
-22
° F to 122° F (-30° C to +50° C)
Scanners:
Spray/rain — IEC 529-IPX5
Dust/particulate — IEC 529-IP6X
Base Stations and Charger:
Spray/rain — IEC 529-IPX4
Dust/particulate — IEC 529-IP5X
Temperature Ranges:
Operating
Storage
Humidity
Beeper/Speaker
Vibration
-22
° F to +122° F (-30° C to +50° C) Corded
-4
° F to +122° F (-20° C to +50° C) RF
-40
° F to +140° F (-40° C to + 60°C)
0 to 95% non-condensing
87 dBA for operator at a distance of 19” (50cm)
Meets MIL-STD-810F
User Manual A-3
NOTES
A-4 4600
Appendix B
Cable Pinouts
Standard Cable Pinouts (Primary
Interface Cables)
RS-232
1
2 CTS
3
4 RTS
5 RXD
6 TXD
7
8 VCC IN
9 GND
10
Pin 1
10 Position RJ
(Scanner End)
IBM Port 5B/9B/17
1
2
3
4 DATA -
5
6 DATA +
7
8 VCC_IN
9 GND
10
Pin 1
10 Position RJ
(Scanner End)
User Manual B-1
Cable Pinouts
IBM USB
1
2
3
4 D -
5
6 D +
7
8 VIN
9 GND
10
Pin 1
USB & USB Keyboard
1
2
3
4 D -
5
6 D +
7
8 VBUS_VIN
9 GND
10
Pin 1
Wand Emulation
1
2
3 WAND~
4
5
6
7
8 VCC_IN
9 GND
10
Pin 1
B-2
10 Position RJ
(Scanner End)
10 Position RJ
(Scanner End)
10 Position RJ
(Scanner End)
PowerScan® 7000 SRI
Standard Cable Pinouts (Primary Interface Cables)
Keyboard Wedge
1
2 KB_DATA
3 AT_CLK
4 KB_CLK
5
6 AT_DATA
7
8 VCC_IN
9 GND
10
Pin 1
10 Position RJ
(Scanner End)
User Manual B-3
Cable Pinouts
NOTES
B-4 PowerScan® 7000 SRI
Appendix C
Alpha-Numeric Pad
A
B
C
D
E
F
User Manual C-1
Alpha-Numeric Pad
1
3
C-2
9
5
7
2
4
6
8
0
PowerScan® 7000 SRI
Appendix D
Default Settings
Standard Feature Defaults
The table immediately below lists the default settings for the standard
RS-232 interface.
Feature
Std.
RS-232
Setting
.4 Second
Disable
Enable
After Decode
Enable
Medium
80 msec
High
Single
5 Seconds
Disable
Interface-Specific
Exceptions
Page #
User Manual D-1
Feature
Std.
RS-232
Setting
Interface-Specific
Exceptions
Host Commands
Host Transmission
Buffers
Baud Rate
Data Bits
Stop Bits
Parity
9600 Baud
8 Data Bits
1 Stop Bit
Parity=None
Disable
No Delay
Disable
Disable
10 msec
Normal
RS-232
RS-232 Std.
Interface as required
IBM Default:
IBM Port 9B
Wincor/Nixdorf Default:
RS-232-WN
Keyboard Wedge
Default:
USB Keyboard
Obey Host
Commands
Buffers=2
IBM:
Buffers=1
Wincor/Nixdorf:
Buffers=1
Wincor/Nixdorf:
Parity=Odd
Wincor/Nixdorf:
CTS Flow Control
Page #
D-2 PowerScan® 7000 SRI
Standard Feature Defaults
Feature
IBM Transmit Labels in Code 39 Format
Wand Emulation:
Wand Emulation:
Wand Emulation:
Wand Emulation:
Enable
200 msec
3
Ignore Errors
Detected
Enable
—
—
—
—
—
—
Std.
RS-232
Setting
Disable
Enable
Enable
Disable
ACK
!
Interface-Specific
Exceptions
IBM-USB: Configure as
Handheld Scanner
IBM: Disable
Wand Emulation: Bar/
Space = High/Low
Wand Emulation: Low
Wand Emulation:
660 msec
Wand Emulation:
Enable
Page #
User Manual D-3
Feature
Wand Emulation:
Wand Emulation:
Keyboard Wedge/
USB Keyboard:
Keyboard Wedge/
USB Keyboard:
Keyboard Wedge/
USB Keyboard:
Keyboard Wedge/
USB Keyboard:
Keyboard Wedge/
USB Keyboard:
Keyboard Wedge/
USB Keyboard:
Global Prefix
Global Suffix
UPC-A Label ID
Std.
RS-232
Setting
—
—
—
—
—
—
—
—
None
CR
Disable
Label ID
Position:
Before Bar
Code Data
A
Interface-Specific
Exceptions
Wand Emulation:
Enable
Wand Emulation:
No Conversion
KBW/USB KB: USA
KBW/USB KB:
100 msec
KBW/USB KB:
10 msec
IBM: No Suffix
IBM: Disable
Keyboard Wedge:
Disable
Page #
KBW/USB KB: Disable
KBW/USB KB: Disable
KBW/USB KB: Disable
D-4 PowerScan® 7000 SRI
Feature
UPC-A w/P2 Addon
Label ID
UPC-A w/P5 Addon
Label ID
UPC-A w/C128 Addon
Label ID
UPC-E Label ID
UPC-E w/P2 Addon
Label ID
UPC-E w/P5 Addon
Label ID
UPC-E w/C128 Addon
Label ID
EAN-8 Label ID
EAN-8 w/P2 Addon
Label ID
EAN-8 w/P5 Addon
Label ID
EAN-8 w/C128 Addon
Label ID
EAN-13 Label ID
EAN-13 w/P2 Addon
Label ID
EAN-13 w/P5 Addon
Label ID
EAN-13 w/C128
Addon Label ID
F
F
F
F
FF
FF
FF
FF
E
E
E
E
Std.
RS-232
Setting
A
A
A
Standard Feature Defaults
Interface-Specific
Exceptions
Page #
Wincor/Nixdorf:
‘C’
Wincor/Nixdorf:
‘B’
Wincor/Nixdorf:
‘F’
User Manual D-5
Feature
ISBN Label ID
GTIN Label ID
GTIN w/P2 addon
Label ID
GTIN w/P5 addon
Label ID
GTIN w/C128 addon
Label ID
RSS-14 Label ID
RSS-14 Composite
Label ID
RSS Expanded Label
ID
RSS Expanded Composite Label ID
RSS Limited Label ID
RSS Limited Composite Label ID
Code 39 Label ID
Pharmacode 39 Label
ID
Code 128 Label ID
I 2 of 5 Label ID
Codabar Label ID
RX
RX
R4
R4
RL
RL
*
A
Std.
RS-232
Setting
I
G
G2
G5
G8
# i
%
Interface-Specific
Exceptions
Wincor/Nixdorf:
‘A’
Page #
Wincor/Nixdorf:
‘E’
Wincor/Nixdorf:
‘E’
Wincor/Nixdorf:
‘E’
Wincor/Nixdorf:
‘E’
Wincor/Nixdorf:
‘E’
Wincor/Nixdorf:
‘E’
Wincor/Nixdorf:
‘K’
Wincor/Nixdorf:
‘I’
Wincor/Nixdorf:
‘N’
D-6 PowerScan® 7000 SRI
Standard Feature Defaults
Feature
Code 93 Label ID
Code 11 Label ID
MSI/Plessey Label ID
Std 2 of 5 Label ID
PDF 417 Label ID
Micro PDF 417 Label
ID
UPC-A
P mP
Disable
No
Conversion
Enable
Send Check
Digit
Don’t
Expand to
EAN-13
Enable
1
1
70 msec
Enable
Std.
RS-232
Setting
&
CE
@ i
Interface-Specific
Exceptions
Wincor/Nixdorf:
“L’
Wincor/Nixdorf:
‘O’
Wincor/Nixdorf:
‘H’
Wincor/Nixdorf:
‘Q’
Page #
User Manual D-7
Feature
EAN-13
EAN-13
EAN-8
EAN-8
Optional 2-Digit
Addons
Optional 5-Digit
Addons
Std.
RS-232
Setting
Send Check
Digit
Exclude System Number
Don’t
Expand
Don’t
Expand
2
Disable
Enable
Send
Check Digit
Transmit
Disable
1
Enable
Send
Check Digit
Don’t
Expand
1
Disable
Disable
Interface-Specific
Exceptions
Page #
D-8 PowerScan® 7000 SRI
Feature
Optional Code 128
Add-ons
RSS-14
RSS Expanded
RSS Expanded
Length 1
RSS Expanded
Length 2
RSS Expanded
Std.
RS-232
Setting
Disable
Disable
Disable
1
Disable
Disable
Disable
Variable
Length
1
74
1
Disable
Disable
Disable
1
Standard Feature Defaults
Interface-Specific
Exceptions
Page #
User Manual D-9
Feature
Code 39
Code 39
Code 39
Code 39
Code 39 Length 1
Code 39 Length 2
Code 39
Pharmacode 39
Disable/Enable
Code 128
Disable/Enable
EAN 128
Std.
RS-232
Setting
Disable
Enable
Disable
Enable
Don’t
Transmit
Disable
Variable
Length
3
50
Don’t
Require
Disable
1
Disable
Don’t
Transmit
Enable
Enable
Disable
D-10
Interface-Specific
Exceptions
Page #
PowerScan® 7000 SRI
Feature
Code 128
Code 128 Length 1
Code 128 Length 2
Code 128
Disable/Enable Interleaved 2 of 5
I 2 of 5 Length 1
I 2 of 5 Length 2
I 2 of 5
Codabar Check Character Verification
Codabar Check Character Transmit
1
Disable
Disable
Enable
Std.
RS-232
Setting
Don’t
Transmit
Variable
Length
1
80
Disable
1
Disable
Disable
Enable
Variable
Length
6
50
Disable
Standard Feature Defaults
Interface-Specific
Exceptions
Page #
User Manual D-11
Feature
Codabar Length 1
Codabar Length 2
Std.
RS-232
Setting
Variable
Length
3
50
Don’t
Require
Start/Stop
Type: abcd/ abcd
Codabar
Code 93 Length 1
Code 93 Length 2
Code 11
Enable
Disable
Disable
1
Disable
Variable
Length
1
50
Disable
1
Disable
1
Interface-Specific
Exceptions
Page #
D-12 PowerScan® 7000 SRI
Feature
Code 11 Check Character Transmit
Code 11 Length 1
Code 11 Length 2
MSI/Plessey Length 1
MSI/Plessey Length 2
Disable/Enable Standard 2 of 5
Std 2 of 5 Length 1
Disable
Disable
Enable
Variable
Length
8
Disable
Disable
1-Digit
Variable
Length
4
16
Disable
1
Std.
RS-232
Setting
Enable
Variable
Length
4
50
1
Standard Feature Defaults
Interface-Specific
Exceptions
Page #
User Manual D-13
Feature
Std 2 of 5 Length 2
Std 2 of 5
PDF 417 Length 1
PDF 417 Length 2
PDF 417
Micro PDF 417 Length
1
Micro PDF 417 Length
2
Std.
RS-232
Setting
50
Disable
1
Disable
Variable
Length
1
600
1
Disable
Disable
Variable
Length
1
366
1
Interface-Specific
Exceptions
Page #
D-14 PowerScan® 7000 SRI
Appendix E
Keyboard Function
Key Mappings
Keyboard Model Cross Reference
summarizes the keyboard models, their defined protocol, scancode set, and some unique features. The remaining tables in this chapter provide the function key maps associated with each of the scancode sets.
User Manual E-1
Table E-1. Keyboard Model Cross Reference
Model Type I/F ID
Transmission
Protocol
Scancode
Set
Func.
Key
Map
Support
Use
Country
Mode
PC/XT Foreign ALT Mode Wedge A PC/XT Scan Set 1 No
AT;
PS/2 25-286;
PS/2 30-286;
Wedge B AT/PS2 Scan Set 2 No
PS/2 50, 50Z;
PS/2 60,70,80,90,95
Foreign ALT Mode
PS/2 25 and 30
Foreign ALT Mode
PC/XT U.S. Mode
Wedge C
Wedge D
AT/PS2 Scan Set 1
PC/XT Scan Set 1
No
Yes
AT;
PS/2 25-286;
PS/2 30-286;
PS/2 50, 50Z;
PS/2 60,70,80,90,95
U.S. Mode + specific country support
PS/2 25 and 30
Wedge E
Wedge F
AT/PS2 Scan Set 2
AT/PS2 Scan Set 1
Yes
Yes
U.S. Mode
IBM 3xxx Terminals
(122-key keyboard)
IBM 3xxx Terminals
(102-key keyboard)
PS55 5530T with
JAPANESE DOS (TDOS)
Wedge G
Wedge H
Wedge I
AT/PS2 Scan Set 3
AT/PS2 Scan Set 3
AT/PS2
Japanese
DOS
Yes
Yes
Yes
NEC 9801 Wedge J
NEC
9801
NEC 9801 Yes
No
No
No
No
Yes
No
No
No
No
No
E-2 PowerScan® 7000 SRI
Keyboard Model Cross Reference
Table E-2. Scanset 1 Function Key Map
ASCII
(hex)
0C
0D
0E
0F
08
09
0A
0B
10
11
12
13
14
04
05
06
07
00
01
02
03
ASCII code Key
NUL ALT right Make
SOH ALT right Break
STX
ETX
ALT left Make
ALT left Break
EOT
ENQ
ACK
BEL
CTRL left Make
CTRL left Break
CTRL right Make
CTRL right Break
DLE
DC1
DC2
DC3
DC4
BS
HT
LF
VT
BS
TAB right
RIGHT arrow (inner keypad)
TAB left
FF Enter (inner keypad)
CR CR
SO
SI
INSERT (inner keypad)
PAGE UP (inner keypad)
PAGE DOWN (inner keypad)
HOME (inner keypad)
LEFT arrow (inner keypad)
DOWN arrow (inner keypad)
UP arrow (inner keypad)
Scancode
E0h 38h
E0h B8h
38h
B8h
1Dh
9Dh
E0h 1Dh
E0h 9Dh
0Eh
0Fh
4Dh + E0
0Fh + S
1Ch + E0
1Ch
52h + E0
49h + E0
51h + E0
47h + E0
4Bh + E0
50h + E0
48h + E0
User Manual E-3
Table E-3. Scanset 2 Function Key Map
ASCII
(hex)
1C
1D
1E
1F
18
19
1A
1B
14
15
16
17
10
11
12
13
0C
0D
0E
0F
08
09
0A
0B
04
05
06
07
00
01
02
03
ASCII code
CAN
EM
SUB
ESC
FS
GS
RS
US
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
Key
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
ALT right Make
ALT right Break
ALT left Make
ALT left Break
CTRL left Make
CTRL left Break
CTRL right Make
CTRL right Break
BS
HT
LF
VT
BS
TAB right
RIGHT arrow (inner keypad)
TAB left
FF Enter (right keypad)
CR CR
SO
SI
INSERT (inner keypad)
PAGE UP (inner keypad)
PAGE DOWN (inner keypad)
HOME (inner keypad)
LEFT arrow (inner keypad)
DOWN arrow (inner keypad)
UP arrow (inner keypad)
F6
F1
F2
F3
F4
F5
ESC
F7
F8
F9
F10
Scancode
04h
0Ch
03h
76h
83h
0Ah
01h
09h
7Ah + E0
6Ch + E0
6Bh + E0
72h + E0
75h + E0
0Bh
05h
06h
E0h 11h
E0h F0h 11h
11h
F0h 11h
14h
F0h 14h
E0h 14h
E0h F0h 14h
66h
0Dh
74h + E0
0Dh + S
5Ah + E0
5Ah
70h + E0
7Dh + E0
E-4 PowerScan® 7000 SRI
Keyboard Model Cross Reference
Table E-4
.
Scanset 3, 102-Key Function Key Map
ASCII (hex) ASCII code
1C
1D
1E
1F
18
19
1A
1B
14
15
16
17
10
11
12
13
0C
0D
0E
0F
08
09
0A
0B
04
05
06
07
00
01
02
03
Key
CAN
EM
SUB
ESC
FS
GS
RS
US
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
ALT right Make
ALT right Break
ALT left Make
ALT left Break
CTRL left Make
CTRL left Break
CTRL right Make
CTRL right Break
BS
HT
LF
VT
BS
TAB right
RIGHT arrow (inner keypad)
TAB left
FF Enter (inner keypad)
CR CR
SO
SI
INSERT (inner keypad)
PAGE UP (inner keypad)
PAGE DOWN (inner keypad)
HOME (inner keypad)
LEFT arrow (inner keypad)
DOWN arrow (inner keypad)
UP arrow (inner keypad)
F6
F1
F2
F3
F4
F5
ESC
F7
F8
F9
F10
Scancode
17h
1Fh
27h
08h
37h
3Fh
47h
4Fh
6Dh
6Eh
61h
60h
63h
2Fh
07h
0Fh
39h
F0h 39h
19h
F0h 19h
11h
F0h 11h
58h
F0h 58h
66h
0Dh
6Ah
0Dh + S
79h
5Ah
67h
6Fh
User Manual E-5
Table E-5. Scanset 3 122-Key Function Key Map
ASCII (hex) ASCII code
1C
1D
1E
1F
18
19
1A
1B
14
15
16
17
10
11
12
13
0C
0D
0E
0F
08
09
0A
0B
04
05
06
07
00
01
02
03
Key
FF
CR
SO
SI
BS
HT
LF
VT
NUL ALT Right Make
SOH ALT Right Break
STX ALT left Make
ETX ALT left Break
EOT CTRL left (RESET) Make only
ENQ CTRL left (RESET) Make/Break
ACK ONLINE Enter Make only
BEL ONLINE Enter Make/Break
BS
TAB right
RIGHT arrow (inner keypad)
TAB left
CR (FIELD EXIT) Make only
CR (FIELD EXIT) Make/Break
INSERT (inner keypad)
FIELD +
DLE FIELD -
DC1 HOME (inner keypad)
DC2 LEFT arrow (inner keypad)
DC3 DOWN arrow (inner keypad)
DC4 UP arrow (inner keypad)
NAK F6
SYN
ETB
F1
F2
CAN F3
EM F4
SUB
ESC
F5
ESC
FS
GS
RS
US
F7
F8
F9
F10
Scancode
17h
1Fh
27h
08h
37h
3Fh
47h
4Fh
7Ch
62h
61h
60h
63h
2Fh
07h
0Fh
39h
F0h 39h
19h
F0h 19h
11h
11h F0h 11h
58h
58h F0h 58h
66h
0Dh
6Ah
0Dh + S
5Ah F0h 5Ah
5Ah
65h
79h
E-6 PowerScan® 7000 SRI
Keyboard Model Cross Reference
Table E-6. Japanese DOS Function Key Map
ASCII value
18h
19h
1Ah
1Bh
1Ch
1Dh
1Eh
1Fh
10h
11h
12h
13h
14h
15h
16h
17h
08h
09h
0Ah
0Bh
0Ch
0Dh
0Eh
0Fh
04h
05h
06h
07h
00h
01h
02h
03h
ASCII code Key
CAN
EM
SUB
ESC
FS
GS
RS
US
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
ALT right Make
ALT right Break
ALT left Make
ALT left Break
CTRL left Make
CTRL left Break
CTRL right Make
CTRL right Break
BS
HT
LF
VT
BS
TAB right
RIGHT arrow (inner keypad)
TAB left
FF Enter (right keypad)
CR CR
SO
SI
INSERT (inner keypad)
PAGE UP (inner keypad)
PAGE DOWN (inner keypad)
HOME (inner keypad)
LEFT arrow (inner keypad)
DOWN arrow (inner keypad)
UP arrow (inner keypad)
F6
F1
F2
F3
F4
F5
ESC
F7
F8
F9
F10
Scancode
6Ah
6Bh
6Ch
3Dh
6Eh
6Fh
70h
71h
51h
4Ch
4Bh
4Ah
4Eh
6Dh
68h
69h
3Eh
3Ch
4Dh
3Ch + S
60h
3Bh
52h
49h
31h
B1h
31h
B1h
41h
C1h
41h
C1h
User Manual E-7
Table E-7. NEC 9801-Key Function Key Map
ASCII value
18h
19h
1Ah
1Bh
1Ch
1Dh
1Eh
1Fh
10h
11h
12h
13h
14h
15h
16h
17h
08h
09h
0Ah
0Bh
0Ch
0Dh
0Eh
0Fh
00h
01h
02h
03h
04h
05h
06h
07h
ASCII code Key Scancode
CAN
EM
SUB
ESC
FS
GS
RS
US
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
NUL unused
SOH CR
STX
ETX
CAPS LOCK ON (make)
CAPS LOCK OFF (break)
EOT
ENQ
ACK
BEL
CTRL left Make
CTRL left Break n/a
1Ch
71h
F1h
74h
F4h
CTRL-C 60h n/a n/a
BS
HT
LF
VT
BS
TAB right
RIGHT arrow (inner keypad)
TAB left
FF DELETE
CR CR
SO
SI
INSERT (inner keypad)
KATAKANA LOCK ON (Make)
0Eh
0Fh
3Ch
0Fh + S
39h
1Ch
38h
72h
KATAKANA LOCK OFF (Break)
HOME (inner keypad)
LEFT arrow (inner keypad)
DOWN arrow (inner keypad)
UP arrow (inner keypad)
F6
F1
F2
F3
F4
F5
ESC
F7
F8
F9
F10
64h
65h
66h
00h
68h
69h
6Ah
6Bh
F2h
3Eh
3Bh
3Dh
3Ah
67h
62h
63h
E-8 PowerScan® 7000 SRI
Keyboard Model Cross Reference
Table E-8. USB Keyboard Function Key Usage Map
Key Value
CAN
EM
SUB
ESC
FS
GS
RS
US
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
FF
CR
SO
SI
BS
HT
LF
VT
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
ASCII
1C
1D
1E
1F
18
19
1A
1B
14
15
16
17
10
11
12
13
0C
0D
0E
0F
08
09
0A
0B
04
05
06
07
00
01
02
03
Usage Name
ALT right Make
ALT right Break
F11
F12
GUI right Make
GUI right Break
CTRL right Make
CTRL right Break
BS
TAB right
RIGHT arrow (inner keypad)
TAB left
Enter (right keypad)
CR
INSERT (inner keypad)
PAGE UP (inner keypad)
F3
F4
F5
ESC
F7
F8
F9
F10
PAGE DOWN (inner keypad)
HOME (inner keypad)
LEFT arrow (inner keypad)
DOWN arrow (inner keypad)
UP arrow (inner keypad)
F6
F1
F2
User Manual E-9
NOTES
E-10 PowerScan® 7000 SRI
Appendix F
Host Commands
Accepting RS-232 Commands
The scanner responds to the following RS-232 commands:
COMMAND
Enable Scanner
Disable
Scanner
Reset Scanner
Not On File
Indication
Beep Good
Read Tone
Force Good
Read Tone
Bel
Identification request
Health request
ASCII
E
D
R
F
B i
HEX
0x45
0x44
0x52
0x46
0x42
0x01
0x07
0x69 h 0x68
Status request s 0x73 a. Call Tech Support for information.
COMMENT
Long series of beeps
Beeps if Good Read Beep is enabled
Beeps regardless of beep setting
Force Good Read Tone
Returns long response a
If one of the above commands is received, the scanner will perform the steps indicated for the command. Host commands for other interfaces is also available. Contact Tech Support for more details.
User Manual F-1
NOTES
F-2 PowerScan® 7000 SRI
Appendix G
Sample Symbols
UPC-A
Interleaved 2 of 5
0 123456 7890
Code 128
1234567890
EAN-13
Code 128
Code 39
9 780330 290951
Codabar
BC321
Code 93
A13579B
Code 2 of 5
123456-9$
123456
User Manual G-1
Sample Symbols
PDF417
Car Registration
RSS Expanded
0100123456789050
RSS-14
(01)00123456789012
G-2 PowerScan® 7000 SRI
Appendix H
Beeper/LED
Indications
LED and Beep Indications
INDICATION
Power-up
Beep
Good Read
Beep
ROM Failure
Limited
Scanning
Label Read
DESCRIPTION
The scanner is in the process of powering-up.
A label has been successfully scanned by the scanner.
LED
N/A
LED behavior for this indication is configurable via the feature
BEEPER
Scanner beeps once for one second at highest frequency and volume upon power-up.
If
is enabled, the scanner will beep once at current frequency, volume and duration upon a successful label scan.
Scanner sounds one error beep at highest volume for 200 mS.
There is an error in the scanner's software/programming
Indicates that a host connection is not established when the IBM or
USB interface is enabled.
200ms on /
200ms off
N/A
Scanner 'chirps' six times at the highest frequency and current volume for 20 mS on /
20 mS off.
User Manual H-1
INDICATION
Scanner
Active Mode
Scanner
Disabled
DESCRIPTION
The scanner is active and ready to scan.
The scanner has been disabled by the host.
LED
The LED is lit steadily. (ONLY applicable if
Dim")
The LED blinks continuously
100mS on / 900 mS off
BEEPER
N/A
N/A
Programming Mode - The following indications ONLY occur when the scanner is in Programming Mode.
Label Programming
Mode Entry
A valid programming label has been scanned.
LED blinks continuously 1 second on / 1 second off
Scanner sounds one good read beep.
Label Programming
Mode Rejection of Label
A label has been rejected.
N/A
Scanner sounds six beeps at highest frequency & current volume for 20 mS on / 20 mS off.
Label Programming
Mode Acceptance of Partial Label
In cases where multiple labels must be scanned to program one feature, this indication acknowledges each portion as it is successfully scanned.
N/A
Scanner sounds one short beep at current frequency & volume for 20 mS.
H-2 4600
INDICATION
Label Programming
Mode Acceptance of Programming
DESCRIPTION
Configuration option(s) have been successfully programmed via labels and the scanner has exited
Programming
Mode.
LED and Beep Indications
LED BEEPER
N/A
Scanner sounds three beeps at current frequency volume for 80 mS on / 20 mS off.
User Manual H-3
Error Codes
Upon startup, if the scanner sounds a long tone, this means the scanner has not passed its automatic Selftest and has entered FRU
1
isolation mode. If the scanner is reset, the sequence will be repeated. The following table describes the LED flashes/beep codes associated with an error found.
NUMBER OF LED
FLASHES/BEEPS
1
2
4
5
6
14
ERROR
Configuration
Interface PCB
Imager Module
Laser Pointer (if so equipped)
Digital PCB
CPLD/Code Mismatch
CORRECTIVE ACTION
Contact Helpdesk for assistance
H-4
1. Field Replaceable Unit (FRU)
4600
NOTES
Error Codes
User Manual H-5
NOTES
H-6 4600
ASCII Chart
ASCII
Char.
CAN
EM
SUB
ESC
FS
GS
RS
US
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
FF
CR
SO
SI
BS
HT
LF
VT
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
Hex No.
1C
1D
1E
1F
18
19
1A
1B
14
15
16
17
10
11
12
13
0C
0D
0E
0F
08
09
0A
0B
04
05
06
07
00
01
02
03
ASCII
Char.
>
?
<
=
;
:
8
9
6
7
4
5
2
3
0
1
/
.
-
,
*
+
)
(
&
’
$
%
SP
!
“
#
Hex No.
3C
3D
3E
3F
38
39
3A
3B
34
35
36
37
30
31
32
33
2C
2D
2E
2F
28
29
2A
2B
24
25
26
27
20
21
22
23
ASCII
Char.
^
_
]
\
Z
[
X
Y
T
U
V
W
P
Q
R
S
L
M
N
O
J
K
H
I
F
G
D
E
@
A
B
C
Hex No.
5C
5D
5E
5F
58
59
5A
5B
54
55
56
57
50
51
52
53
4C
4D
4E
4F
48
49
4A
4B
44
45
46
47
40
41
42
43
ASCII
Char.
}
|
~
DEL z
{ x y v w t u r s p q n o l m k j h i f g d e b c
‘ a
Hex
No.
7C
7D
7E
7F
78
79
7A
7B
74
75
76
77
70
71
72
73
6C
6D
6E
6F
68
69
6A
6B
64
65
66
67
60
61
62
63
©2007 Datalogic Scanning, Inc.
R44-2704 (Rev. A) 4/07
Изтегляне
Реклама