Cables and Connectors
PIN DESCRIPTION WIRE
1 Bell-
2 Bell+
Purble
Brown
3 Sensor
4 GND
5 Button
White
Black
Gray
6 NO
7 COM
8 NC
9 Alarm+
10 Alarm-
Blue
Red
Yellow
Orange
Green
PIN DESCRIPTION WIRE
1 WD0 Green
2 WD1 White
3 GND
4 232 RX
5 232 TX
6 GND
7 485A
8 485B
Black
Gray
Purple
Black
Blue
Yellow
PIN DESCRIPTION WIRE
1 12V Red
2 GND
3 INWD1
Black
White
4 INWD0
5 RLED
6 GLED
7 BEEP
Green
Blue
Gray
Purple
1
2
7
8
5
6
3
4
1
2
•
Alarm
Lock
•
Button
Door Sensor
•
Door Bell
•
Wiegand Output
RS232
•
RS485
•
Wiegand Output
LED
•
Power Out
Beep
PIN DESCRIPTION WIRE
1 RJ45-1 Yellow
2 RJ45-2
3 RJ45-3
4 RJ45-6
Green
Red
Black
PIN DESCRIPTION WIRE
1 12V DC Red
2 GND Black
•
•
TCP/IP
Power In
F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE
9
advertisement
Related manuals
advertisement
Table of contents
- 2 What’s in the Box
- 4 Optional accessories
- 5 Safety Precautions
- 6 Product PIN Diagram
- 8 Product Dimension
- 9 Cables and Connectors
- 10 Mounting the reader on the Wall
- 11 Power Connection
- 12 Ethernet Connection
- 14 RS485 Connection
- 16 RS485 Connection
- 18 Lock Relay Connection
- 20 Weigand Output Connection
- 21 Standalone Installation
- 22 Standalone Installation
- 23 How Does F18 work
- 24 How to Place a Finger
- 26 Troubleshooting
- 27 Electrical Specifications
- 28 Specifications