Order codes

4222 = Universal I/f converter

4501 = Display / programming front

Electrical specifications

Specifications range ............................................... -20°C to +60°C

Calibration temperature ........................................ 20...28°C

Relative humidity..................................................... < 95% RH (non-cond.)

Protection degree .................................................... IP20

Mechanical specifications

Dimensions (HxBxD) ............................................... 109 x 23.5 x 104 mm

Dimensions, with 4501 / 4511 (HxBxD) ......... 109 x 23.5 x 116 / 131 mm

Weight .......................................................................... 155 g

Weight with 4501 / 4511 .................................... 170 g / 255 g

Max. wire size ............................................................ 1 x 2.5 mm 2

Screw terminal torque ........................................... 0.5 Nm

stranded wire

Common specifications

Supply voltage, universal ..................................... 21.6...253 VAC, 50...60 Hz or

19.2...300 VDC

Max. consumption .................................................... ≤ 2.5 W

Fuse ............................................................................... 400 mA SB / 250 VAC

Isolation voltage, test / operation .................... 2.3 kVAC / 250 VAC

Communications interface ................................... Communication enabler 4511

Programming front 4501

Signal / noise ratio .................................................. Min. 60 dB (0...100 kHz)

Response time (0...90%, 100...10%), programmable:

Temperature input ............................................. 1...60 s

mA / V input ......................................................... 0,4...60 s

Accuracy, the greater of the general and basic values:

Input type

All

General values

Absolute accuracy

≤ ±0.1% of span

Temperature coefficient

≤ ±0.01% of span / °C

12 4222V101-UK

Input type mA

Volt

Pt100

Linear resistance

Potentiometer

TC type:

E, J, K, L, N, T, U

TC type: B, R, S,

W3, W5, LR

Basic values

Basic accuracy

≤ ±4 µA

≤ ±20 µV

≤ ±0.2°C

≤ ±0.1 Ω

≤ ±0.1 Ω

≤ ±1°C

≤ ±2°C

Temperature coefficient

≤ ±0.4 µA / °C

≤ ±2 µV / °C

≤ ±0.01°C / °C

≤ ±0.01 Ω / °C

≤ ±0.01 Ω / °C

≤ ±0.05°C / °C

≤ ±0.2°C / °C

EMC immunity influence ........................................... < ±0.5% of span

Extended EMC immunity:

NAMUR NE 21, A criterion, burst .......................... < ±1% of span

Auxiliary supplies:

2-wire supply (terminal 44...43) ........................ 25...16 VDC / 0...20 mA

RTD, linear resistance and potentiometer input:

Input for RTD types:

Pt10, Pt20, Pt50, Pt100, Pt200, Pt250, Pt300, Pt400, Pt500, Pt1000

Ni50, Ni100, Ni120, Ni1000

Input type

Pt100

Ni100

Lin. resistance

Potentiometer

Min. value

-200°C

-60°C

0 Ω

10 Ω

Max. value

+850°C

+250°C

10000 Ω

100 k Ω

Standard

IEC60751

DIN 43760

-

-

Cable resistance per wire (max.), RTD............. 50 Ω

Sensor current, RTD ................................................ Nom. 0.2 mA

Effect of sensor cable resistance

(3- / 4-wire), RTD ..................................................... < 0.002 Ω / Ω

Sensor error detection, RTD ................................ Yes

Short circuit detection, RTD ................................ < 15 Ω

4222V101-UK 13

TC input

Type

L

N

R

S

B

E

J

K

T

U

W3

W5

LR

Min. value

+400°C

-100°C

-100°C

-180°C

-200°C

-180°C

-50°C

-50°C

-200°C

-200°C

0°C

0°C

-200°C

Max. value

+1820°C

+1000°C

+1200°C

+1372°C

+900°C

+1300°C

+1760°C

+1760°C

+400°C

+600°C

+2300°C

+2300°C

+800°C

Standard

IEC 60584-1

IEC 60584-1

IEC 60584-1

IEC 60584-1

DIN 43710

IEC 60584-1

IEC 60584-1

IEC 60584-1

IEC 60584-1

DIN 43710

ASTM E988-90

ASTM E988-90

GOST 3044-84

Cold junction compensation (CJC)

via internally mounted sensor ...................... < ±1.0 °C

Sensor error detection, all TC types................. Yes

Sensor error current:

when detecting ................................................... Nom. 2 μA

else .......................................................................... 0 μA

Current input

Measurement range ................................................ -1...25 mA

Programmable measurement ranges ............... 0...20 and 4...20 mA

Input resistance........................................................ Nom. 20 Ω + PTC 50 Ω

Sensor error detection:

loop break 4...20 mA ......................................... Yes

Voltage input:

Measurement range ................................................ -20 mV...12 VDC

Programmable measurement ranges ............... 0...1 / 0.2...1 / 0...2.5 / 0.5...2.5 /

0...5 / 1...5 / 0...10 and 2...10 VDC

Input resistance........................................................ Nom. 10 M Ω

Output

Frequency output

Frequency range ...................................................... 0...25000 Hz

Min. frequency (span) ............................................ 0.001 Hz

Duty cycle (0...25000 Hz) .................................... 50% or

Programmable pulse time (f

≤ 500 Hz) .......... 1...1000 ms (max. 90% duty cycle)

14 4222V101-UK

PNP output

I out

max. ....................................................................... 30 mA

V out

................................................................................ 24 VDC ± 10%

C out

................................................................................ 10 nF

R out

typ. ....................................................................... 20

Ω

Electromechanical counter ................................... 24 V / 135 mA / 20 ms / ≤ 10 Hz

NPN output

I sink

max. ...................................................................... 150 mA

I sink

max. peak ........................................................... 300 mA

External voltage (terminal 23) max. ................ 55 VDC

C out

................................................................................ 10 nF

R out

typ. ....................................................................... 10

Ω

TTL output

I

I sink/source sink/source

R out

max. .......................................................... 15 mA

peak.......................................................... 100 mA

V out

................................................................................ 5 V ±5%

C out

................................................................................ 10 nF

typ. ....................................................................... 55 Ω

Sensor error detection

Programmable ........................................................... 0...26250 Hz

Ex / I.S. approval

FM, applicable in ....................................................... Class I, Div. 2, Group A, B, C, D

Class I, Div. 2, Group IIC

Zone 2

Max. ambient temperature for T5 .................... 60°C

Observed authority requirements Standard

EMC 2004/108/EC .................................................. EN 61326-1

LVD 2006/95/EC ...................................................... EN 61010-1

FM .................................................................................. 3600, 3611, 3810 and ISA 82.02.01

UL, Standard for Safety ......................................... UL 508

EAC TR-CU 020/2011 ............................................ EN 61326-1 of span = of the currently selected measurement range