58

8.5 Setting up tank gear alarms

8.5. Setting up tank gear alarms

Gear alarms will trigger if the gear ratio value entered in the drive setup menu is different to the value calculated based on the shaft sensor and motor encoder.

1. Select Settings Menu / Alarm Settings Menu / Tank

Gear Alarms

.

2. Select Tank Gear # to enable the alarm. # denotes the tank number.