TABLE 6

TEMPERATURE PRESSURE CHART

-25 [-31.6]

-20 [-28.8]

-15 [-26.1]

-10 [-23.3]

-5 [-20.5]

0 [-17.7]

5 [-15]

10 [-12.2]

15 [-9.4]

20 [-6.6]

25 [-3.8]

30 [-1.1]

35 [1.6]

40 [4.4]

45 [7.2]

50 [10]

TEMP

(Deg. F) [°C]

-150 [-101.1]

-140 [-95.5]

-130 [-90]

-120 [-84.4]

-110 [-78.8]

-100 [-73.3]

-90 [-67.7]

-80 [-62.2]

-70 [-56.6]

-60 [-51.1]

-50 [-45.5]

-40 [-40]

-35 [-37.2]

-30 [-34.4]

55 [12.7]

60 [15.5]

65 [18.3]

70 [21.1]

75 [23.3]

80 [26.6]

85 [29.4]

90 [32.2]

95 [35]

100 [37.7]

105 [40.5]

110 [43.3]

115 [46.1]

120 [48.8]

125 [51.6]

130 [54.4]

135 [57.2]

140 [60]

145 [62.7]

150 [65.5]

22.0 [151.7]

26.4 [182.0]

31.3 [215.8]

36.5 [251.6]

42.2 [290.9]

48.4 [333.7]

55.1 [379.9]

62.4 [430.2]

70.2 [484.0]

78.5 [541.2]

87.5 [603.3]

97.2 [670.2]

107.5 741.2]

118.5 [817.0]

130.2 [897.7]

142.7 [983.9]

R-410A

PSIG [kPa]

0.4 [2.7]

5.1 [35.1]

10.9 [75.1]

14.2 [97.9]

17.9 [123.4]

156.0 [107.6]

170.1 [1172.8]

185.1 [1276.2]

201.0 [1385.8]

217.8 [1501.7]

235.6 [1624.4]

254.5 [1754.7]

274.3 [1891.2]

295.3 [2036.0]

317.4 [2188.4]

340.6 [2348.3]

365.1 [2517.3]

390.9 [2695.2]

418.0 [2882.0]

446.5 [3078.5]

476.5 [3285.3]

508.0 [3502.5]

541.2 [3731.4]

576.0 [3971.4]

612.8 [4225.1]

16.5 SUBCOOLING CALCULATION

1. Measure the liquid pressure at the liquid line service valve.

2. Convert the liquid line pressure to saturated temperature. See Table 6.

3. Measure the liquid line temperature at the liquid line service valve.

4. Compare the liquid line temperature to the saturated temperature.

5. The difference between saturated temperature and liquid line temperature is the subcooling. Subcooling normal range 9° to 12° in the cooling mode. Subcooling in the heating mode can vary widely from model to model and should never be used to determine the correct charge in the field.

TABLE 7

HEAT PUMP SYSTEM TROUBLESHOOTING TIPS

SYSTEM PROBLEM

Overcharge

Undercharge

Liquid Restriction (Drier)

Low Evaporator Airflow

Dirty Heat Pump

Low Outside Ambient Temperature

Inefficient Compressor

TEV Feeler Bulb Charge Lost

Poorly Insulated Sensing Bulb

HEAT PUMP SYSTEM

TROUBLESHOOTING TIPS

INDICATORS

DISCHARGE SUCTION

PRESSURE PRESSURE

High High

Low

Low

Low

High

Low

Low

Low

High

Low

Low

Low

High

Low

High

Low

High

SUPERHEAT SUBCOOLING

Low

High

High

Low

Low

High

High

High

Low

High

Low

High

Low

Low

High

High

High

Low

COMPRESSOR

AMPS

High

Low

Low

Low

High

Low

Low

Low

High

25