2: Installing the QE-PRO
Connect Spectroscopic Accessories
To find operating instructions for QE Pro compatible products (such as light sources, sampling chambers, and probes), visit the Ocean Optics website at
http://www.oceanoptics.com/technical/operatinginstructions.asp.
External Triggering Options
You can trigger the QE Pro using a variety of External Triggering options through the 30-pin Accessory
Connector on the spectrometer. See the External Triggering Options document located at
http://oceanoptics.com///wp-content/uploads/External-Triggering-
Options_Firmware3.0andAbove.pdf
. The triggering document contains instructions for configuring
External Triggering options for the QE Pro.
Change the Slit
There’s no need to calibrate your spectrometer when changing the slit, just install and start measuring.
There is one exception to this. You cannot change from a standard slit to a slit with a filter because it changes the optical focus and wavelength calibration of the spectrometer. In this case you would need to send the spectrometer back to Ocean Optics. A filter must be ordered for each slit (if your application requires a filter) and the spectrometer needs to be calibrated and focused with the filter installed. This only applies to filters installed inside the slit assembly.
►
Procedure
1. Find the SMA connector. If a fiber is attached, remove it.
18
2. Use the Allen key to remove the 2 the screws attaching the slit to the spectrometer.
3. Pull the slit out of the spectrometer.
4. Put the new INTSMA slit connector into the spectrometer; with the key of the connector on the left side.
891-00000-000-02-201603
2: Installing the QE-PRO
5. Install the 2 screws again. Use the Allen key to tighten the screws carefully (do not over-tighten).
6. If necessary, connect the fiber again.
891-00000-000-02-201603 19
advertisement
Related manuals
advertisement
Table of contents
- 9 Product Overview
- 10 Models
- 10 Features
- 11 System Requirements
- 12 EEPROM Utilization
- 12 About Ocean Optics Software
- 12 Sampling System Overview
- 12 How Sampling Works
- 12 Modular Sampling Accessories
- 12 Interface Options
- 13 Shipment Components
- 14 Other Accessories Available
- 14 Breakout Box
- 15 Overview
- 15 QE Pro Installation
- 15 USB Mode
- 16 QE Pro Spectrometer Device Driver Installation
- 16 Installing the Driver Software for QE Pro Spectrometers on Windows 7 (32 and 64-bit)
- 20 Serial Port Mode
- 20 LED Operation
- 21 Configuring the QE Pro
- 21 Configuring QE Pro in OceanView
- 22 OceanView QE Pro Acquisition Controls
- 26 Connect Spectroscopic Accessories
- 26 External Triggering Options
- 26 Change the Slit
- 28 Overview
- 28 QE Pro Connected to Computer Prior to Software Installation
- 28 Windows Operating Systems
- 28 Remove the Unknown Device from Windows Device Manager
- 29 Apple Mac OSX Operating Systems
- 29 Linux Operating Systems
- 30 Overview
- 30 About Wavelength Calibration
- 31 Calibrating the Spectrometer
- 31 Preparing for Calibration
- 31 Calibrating the Wavelength of the Spectrometer
- 33 Saving the New Calibration Coefficients: USB Mode
- 35 Overview
- 35 How the QE Pro Works
- 36 QE Pro Components Table
- 37 QE Pro Specifications
- 37 CCD Detector Specifications
- 37 QE Pro Spectrometer Specifications
- 38 System Compatibility
- 39 30-Pin Accessory Connector Pinout
- 39 30-Pin Accessory Connector Pinout Diagram
- 39 – Pin Definitions and Descriptions
- 41 30-Pin J2 Accessory Connector - Part Numbers
- 41 HR4-CBL-DB15 Accessory Cable Pinout
- 43 Index