Alternate Priming Method

Alternate Priming Method

4.

Hold sprayer above sink or waste area, disengage the trigger lock, and quickly trigger sprayer until material comes out of the drain tube.

1.

Engage trigger lock and put prime/relief valve UP to release pressure.

ti14995a ti14991a ti14994a ti14999a

2.

Remove material cup and fill with flushing material.

NOTE: Material can shoot out of the drain tube

when performing this procedure. Be sure to wear appropriate safety equipment and point drain tube away from yourself when pulling the trigger,

5.

Thread the material cup back onto sprayer.

3.

With sprayer in prime mode, turn sprayer upside-down, remove strainer and slowly pour flushing material into the intake tube until full.

6.

Trigger the gun for 10 seconds then release the trigger and put the prime/relief valve DOWN to spray position. ti15425a

7.

Reverse spray tip to UNCLOG position and spray into waste area for five seconds to ensure sprayer has primed.

3A0159D

ti14995a ti14991a

8.

Sprayer is now ready to spray. Follow Starting New

Job instructions on page 12.