advertisement
Inlet Valve Cleaning
Inlet Valve Cleaning
Removal
1.
Engage trigger lock and pull relief valve UP to release pressure.
ti14994a ti14999a
2.
Remove material cup and suction tube.
4.
Clean as much excess material from pump cavity as possible. Make sure you also clean spring (a), o-ring
(c), and top of inlet fitting (d).
Installation
NOTE: Before installing, make sure o-ring (c) is installed
on inlet valve (b).
1.
Place inlet valve (b) with spring (a) on top of inlet fitting (d). Push inlet fitting up into pump cavity. a b c ti15504a
3.
Hold sprayer upside-down and use wrench or socket to loosen and remove inlet fitting, inlet valve, and spring. d ti15502a
2.
Hold inlet in place and turn sprayer upside-down.
Remove inlet fitting and visually check to see that inlet valve has seated correctly.
24
3.
Replace inlet fitting and use wrench and socket to tighten to 10 ft-lb.
NOTICE
Do NOT over-tighten inlet fitting. Damage to the equipment will occur.
ti15505a
NOTE: Make sure the spring also comes out. Use
needle-nose pliers to remove if needed. Inlet cavity should be completely empty (as shown below).
ti15530a
4.
Use your Fine-Finish Optimizer cleaning tool to lightly push on inlet valve to make sure it moves up and down freely.
ti15509a
3A0159D
advertisement
Related manuals
advertisement
Table of contents
- 2 Table of Contents
- 2 Important User Information
- 2 Read this before using your sprayer. See the Operation Manual provided with your sprayer for complete instructions on proper use and safety warnings.
- 3 Warnings
- 6 TrueCoat™ Component Identification
- 7 TrueCoat™ Plus Component Identification
- 8 Using Electrical Cords
- 8 Grounding and Electrical Requirements
- 8 Power Cord
- 8 Extension Cord Requirements
- 9 Common Procedures
- 9 Pressure Relief Procedure
- 9 Trigger Lock
- 9 Spray Tip Position
- 9 Control Lever Position
- 10 Setup
- 10 Overheating Protection
- 10 Installing Suction Tube
- 10 Spraying Stains or Clear Coats (Fine-Finish Optimizer)
- 11 Sprayer Setup
- 13 Install Tip/Guard Assembly (if not installed)
- 13 Shoulder Strap Installation
- 14 Basic Spraying Techniques
- 14 Triggering Sprayer
- 14 Aiming Sprayer
- 15 Unclogging Spray Tip/Guard Assembly
- 16 Shutdown and Cleaning
- 16 Flushing Sprayer
- 18 Cleaning Sprayer Exterior
- 18 Tips
- 18 Storage
- 19 Replacement Parts and Kits
- 20 Troubleshooting
- 23 Alternate Priming Method
- 24 Inlet Valve Cleaning
- 25 Technical Data
- 26 Notes
- 27 Notes
- 28 Graco Standard Warranty
- 28 For the latest information about Graco products, visit www.graco.com. Contact Graco Customer Service at 1-888-541-9788.