Reference Guide. BMC Express for Hardware
Реклама
Реклама
BMC Performance Manager Express for Hardware
Version 2.7.17
This chapter provides the following detailed chapters:
Classes and Parameters: Parameters, info boxes and menu commands for each application class
Connectors and Platforms: supported platforms, instrumentation agents or system tools they require as well as the connectors that are used to monitor them. Details are given for each connector and show all the components discovered and monitored through them.
80
BMC Performance Manager Express for Hardware
Version 2.7.17
Application Classes
This section familiarizes you with all the Application classes used by BPM Express for Hardware on the
Portal. It gives a detailed view of each application class describing its function and parameters.
Application Classes
81
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_BATTERY
SEN_HW_BATTERY can be a children of SEN_HW_ENCLOSURE and SEN_HW_DISKCONTROLLER.
Parameters
Name
Status
Type
Text
Charge Numeric
Description
Displays the battery status.
Values: OK; Warning; Alarm
Displays the percentage of the battery charge.
Locator Text Helps to physically locate a component.
Alert Conditions
“!” = Warning
“!!” = Alarm
= 50% Warning
= 30 % Alarm n/a
SEN_HW_BATTERY
82
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_BATTERY
83
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_BLADE
Each instance of the SEN_HW_BLADE class represents a blade server inside a blade enclosure. The
Status parameter represents the global status of the blade
Parameters
Name
Status
Type
Text
Locator Text
Description
Displays the overall blade status.
Values: OK; Warning; Alarm
Example: “OK” or “Alarm!! The blade is missing”
Helps to physically locate a component.
Alert Conditions
“!” = Warning
“!!” = Alarm n/a
"Sta tus" is a te x t pa ra me te r tha t giv e s the ov e ra ll sta tus of the corre sponding de v ice or se nsor. A n a le rt condition de scribe s in sy mbolic te rms wha t occurs in the pa ra me te r whe n thre sholds a re bre a che d: one e x cla ma tion ma rk trigge rs a wa rning; two e x cla ma tion ma rks ra ise a n a la rm.
Example
If BPM Express for Hardware detects that a blade has exceeded manufacturer-specified thresholds, the Status parameter will report “Warning! or Alarm!! The blade is missing”, or as the case may be.
On clicking the history graph, you can see the exact problem details, the consequences and the recommended actions.
De pe nding on y our sy ste m, a ll pa ra me te rs ma y not be use d.
SEN_HW_BLADE
84
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_BLADE
85
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_CAPACITYREPORT
Parameters
Name Type
Physical
CPU Count
Connected
Ethernet/
Fiber Ports
Memory
Size
Total
Physical
Disk Size
Numeric
Numeric
Numeric
Numeric
Total
Logical Disk
Size
Numeric
Numeric Total
Unallocate d Space
Power
Consumpti on
Numeric
Energy
Usage
Degrees
Below
Warning
Numeric
Numeric
Description
Host total number of physical processors (CPU)
Total number of connected Ethernet/Fiber Ports
Host total memory (RAM)
Unit : GB
Host total physical disk size
Unit: GB
Host total logical disk size
Unit : GB
Host Total available disk space that is not allocated to any volume
Unit: GB
Power consumed by the host
Unit: Watts
Energy usage of the system
Unit: kWh
Degrees left before reaching the defined threshold
Alert
Conditions
n/a n/a n/a n/a n/a n/a n/a n/a n/a
SEN_HW_CAPACITYREPORT
86
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_CAPACITYREPORT
87
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_CONNECTOR
Each instance of the SEN_HW_CONNECTOR class represents a connector currently used by BPM Express for Hardware in order to discover and monitor the hardware components of the server.
Connectors are continuously monitored to ensure that the underlying technology used by BPM
Express for Hardware to discover and monitor the hardware functions properly.
If something goes wrong with the hardware instrumentation layer (but not with the hardware itself), an alert is raised by the Status parameter of the corresponding SEN_HW_CONNECTOR instance.
In this case, hardware components that were discovered and monitored through this connector will no longer be monitored. Check the Test Report parameter to have more details about the connector failure.
Parameters
Name
Test Report
Status
Locator
Type Description
Text
Text
Text
Describes the tests performed to evaluate the status of the connector
Displays the overall connector status
Values: OK; Warning; Alarm
Example: “OK” or “Alarm!! The connector is not working anymore”
Helps to physically locate a component.
Alert Conditions
n/a
“!” = Warning
“!!” = Alarm
N/A
"Sta tus" is a te x t pa ra me te r tha t giv e s the ov e ra ll sta tus of the corre sponding de v ice or se nsor. A n a le rt condition de scribe s in sy mbolic te rms wha t occurs in the Sta tus pa ra me te r whe n thre sholds a re bre a che d: one e x cla ma tion ma rk trigge rs a wa rning; two e x cla ma tion ma rks ra ise a n a la rm.
Example
If BPM Express for Hardware detects that a connector has exceeded a manufacturer-specified threshold, the Status parameter will report "Alarm!!. This connector is not working anymore". On clicking the history graph, you can see the exact details of the problem, its consequences and the recommended actions.
De pe nding on y our sy ste m, a ll pa ra me te rs ma y not be use d.
SEN_HW_CONNECTOR
88
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_CONNECTOR
89
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_CPU
Each instance of the SEN_HW_CPU class represents a physical processor of the server. On high-range servers, the Status parameter will raise an alert "on the fly" as soon as a processor fails. On most servers however, a failed processor causes a server crash. Upon reboot, the processor is likely to be automatically disabled by the BIOS which will then raise an alert in BPM Express for Hardware because the processor is "missing".
The Corrected Error Count and Predicted Failure parameters (available only for a few high-end processors) help administrators intervene before such a crash occurs.
The "Sta tus" pa ra me te r will re port a n A la rm if the "C orre cte d Error C ount" pa ra me te r is gre a te r tha n ze ro (tha t is: the disk e ncounte re d some e rrors). Since the counte r is re se t e v e ry 24th hour, the corre sponding a le rt on the
"Sta tus" pa ra me te r will be a utoma tica lly cle a re d a fte r 24 hours. This me cha nism ha s be e n imple me nte d to le t BPM
Ex pre ss for Ha rdwa re /Porta l re port pure e v e nt-driv e n a le rts with no ne e d for ma nua l a cknowle dge me nt from the ope ra tors.
Parameters
Name
PredictedFailure
CorrectedErrorCou nt
CurrentSpeed
Status
Locator
Type Description Alert Conditions
Text Triggers an alert through the Status parameter if a CPU failure is expected
Values : OK; Predicted Failure n/a n/a Integer Displays the number of detected and corrected errors
Unit: Errors
Numeri c
Displays the current clock speed of the processor in megahertz n/a
Text
Text
Displays the overall CPU status.
Values: OK; Warning; Alarm
Example: “OK” or “Warning! Failure of the CPU is predicted”
Helps to physically locate a component.
“!” = Warning
“!!” = Alarm
N/A
"Sta tus" is a te x t pa ra me te r tha t de scribe s the ov e ra ll sta tus of the corre sponding de v ice or se nsor. A le rt conditions de scribe in sy mbolic te rms wha t occurs in the "Sta tus" pa ra me te r whe n thre sholds a re bre a che d: one e x cla ma tion ma rk trigge rs a wa rning; two e x cla ma tion ma rks ra ise a n a la rm.
Example
If BPM Express for Hardware detects that manufacturer-specified thresholds have been breached for a
CPU, the Status parameter will report “Warning! Problem: This processor is degraded or about to fail." Or “Alarm!! This processor is not detected anymore", or as may be the case. On clicking the history graph, you can see the exact details of the problem, its consequences and the recommended actions.
90
SEN_HW_CPU
BMC Performance Manager Express for Hardware
Version 2.7.17
De pe nding on y our sy ste m, a ll pa ra me te rs ma y not be use d.
SEN_HW_CPU
91
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_CPU
92
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_CPUCORE
SEN_HW_CPUCORE can be a children of SEN_HW_CPU only.
Parameters
Name
Status
Type
Text
UsedTim e
Percent
Numeric
Locator Text
Description
Displays the CPU Core status.
Values: OK; Warning; Alarm
Displays the percentage of the CPU core usage.
The "Used Time Percent" parameter is calculated as:
(UsedTime - LastUsedTime) / (currentTime - lastTime)
*100
Helps to physically locate a component.
Alert Conditions
“!” = Warning
“!!” = Alarm
= 50% Warning
= 100 % Alarm n/a
SEN_HW_CPUCORE
93
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_CPUCORE
94
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_DISKCONTROLLER
The purpose of the Disk Controller instance is to display the status of the disk controller battery and the status of the disk controller. In addition, some information regarding the disk controllers, like its brand, model or driver version, may be displayed.
The Battery Status parameter triggers an alert to predict that the disk controller battery will be unable to support the controller in the event of a power failure.
The Controller Status parameter displays the status of the disk controller.
Parameters
Name Type
Battery Status Text
Controller
Status
Locator
Text
Text
Description
Triggers an alert to predict that the disk controller battery will be unable to support the controller in the event of a power failure.
Values: OK; Warning; Alarm
Displays the status of the disk controller
Values: OK; Warning; Alarm
Helps to physically locate a component.
Alert Conditions
“!” = Warning
“!!” = Alarm
“!” = Warning
“!!” = Alarm
N/A
De pe nding on y our sy ste m, a ll pa ra me te rs ma y not be use d.
SEN_HW_DISKCONTROLLER
95
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_DISKCONTROLLER
96
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_ENCLOSURE
Basically, each SEN_HW_ENCLOSURE instance represents a box with some hardware components inside. This class is used to represents the computer's main chassis, but also external disk array enclosures or blade enclosures.
The Intrusion Status parameter, when available, raises an alert when the chassis is opened.
The Status parameter, if collected, represents the overall status.
Parameters
Name Type
IntrusionStatus Text
Status
Locator
Text
Text
Description
Triggers an alert if the enclosure is opened
Values : OK ; Intrusion Detected
Example: "Alarm!! Problem: The enclosure is open or has been removed"
Displays the overall status of the enclosure
Values: OK; Warning; Alarm
Helps to physically locate a component.
Alert Conditions
“!!” = Alarm
“!” = Warning
“!!” = Alarm n/a
"Sta tus" is a te x t pa ra me te r tha t de scribe s the ov e ra ll sta tus of the corre sponding de v ice or se nsor.
De pe nding on y our sy ste m, a ll pa ra me te rs ma y not be use d.
SEN_HW_ENCLOSURE
97
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_ENCLOSURE
98
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_FAN
This class creates monitoring objects for each cooling sensor it discovers. Depending on the system and the data available, one or more parameters will be associated to the fan monitoring. Critical devices like processors, power supplies etc, have fans to avoid over-heating. Monitoring fans is important because they ensure a proper temperature for the system to work efficiently.
Depending on the available information, the Speed and/or Status parameters will be displayed for each detected fan device:
The Speed parameter represents the speed of the corresponding fan (in rotations/minute). An alert is raised through Status if the fan speed is too low for proper functioning.
The Speed Percent parameter represents the speed of the corresponding fan in percentage of its maximal speed.
The Status parameter represents the overall status of the fan. An alert is triggered if the fan stops spinning or does not spin fast enough.
Parameters
Name
Speed
SpeedPerce nt
Status
Locator
Type Description
Integer Displays the speed of the fan
Unit: Rotation Per Minute (RPM)
Text Displays the speed of the fan as a percentage of its maximal speed
Unit = Percent of maximal speed
Text
Text
Displays the overall fan status
Values: OK; Warning; Alarm
Example: “OK” or “Alarm!! This fan is not detected anymore”
Helps to physically locate a component.
Alert Conditions
n/a n/a
“!” = Warning
“!!” = Alarm n/a
"Sta tus" is a te x t pa ra me te r tha t de scribe s the ov e ra ll sta tus of the corre sponding de v ice or se nsor. A le rt conditions de scribe in sy mbolic te rms wha t occurs in the pa ra me te r whe n thre sholds a re bre a che d: one e x cla ma tion ma rk trigge rs a wa rning; two e x cla ma tion ma rks ra ise a n a la rm.
Example
If BPM Express for Hardware detects that a fan has breached manufacturer-specified thresholds, the
Status parameter will report “Warning! This fan is degraded/is about to fail” or “Alarm!! This fan is not detected anymore", as may be the case. The history graph shows the exact details of the problem, its consequences and recommended actions.
De pe nding on y our sy ste m, a ll pa ra me te rs ma y not be use d.
99
SEN_HW_FAN
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_FAN
100
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_LED
SEN_HW_LED instances can be children of SEN_HW_ENCLOSURE only.
Parameters
Name
Status
Type
Text
Color Text
Locator Text
Description
Led Status. Depending on the LED, On, Off or Blinking may mean OK, WARNING or ALARM. So, if "On" means
OK, Status will be "On". But if "On" means "Degraded",
Status will be "On!". And if "On" means "Critical", Status will be "On!!". Same for "Off" and "Blinking".
Values: OK; Warning; Alarm
Color of the LED.
Helps to physically locate a component.
Alert Conditions
“!” = Warning
“!!” = Alarm n/a n/a
SEN_HW_LED
101
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_LED
102
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_LOGICALDISK
This class creates instances for each logical disk discovered. Logical disks are often a group of physical disks, configured as an array (RAID 0, 1, 5, etc.) and exposed to the operating system as a single physical volume.
The status of a logical disk typically corresponds to the status of a RAID array (on-line, degraded, rebuilding, etc.). For each logical disk discovered, the Status parameter is displayed.
The Error Count parameter represents number of errors encountered by the logical disk since the last counter reset. The error count is automatically reset every 24th hour (by default; this setting is configurable).
The Status parameter represents the overall status of the logical disk. An alert is triggered when the logical disk is not fully operational (degraded, rebuilding, etc.) or not available at all. It triggers an alert if the logical disk missing or if any of the other parameters have breached their thresholds.
It is only Status that will trigger and display the alerts. When all is fine, Status shows “OK”, and when there is a problem, it shows “Warning!” or “Alarm!!” with a detailed description of the issue, its consequences and recommended actions. The alert conditions for Status are: “!”=Warning;
“!!”=Alarm. Example: “OK” or “Alarm!!” This logical disk is no longer detected."
F or non-R A ID disk controlle rs (a s most of IDE controlle rs, for e x a mple ), no logica l disk will be displa y e d.
The "Sta tus" pa ra me te r will re port a n A la rm if the "Error C ount" pa ra me te r is gre a te r tha n ze ro (tha t is: the disk e ncounte re d some e rrors). Since the counte r is re se t e v e ry 24th hour, the corre sponding a le rt on the "Sta tus" pa ra me te r will be a utoma tica lly cle a re d a fte r 24 hours. This me cha nism ha s be e n imple me nte d to le t the sy ste m re port pure e v e nt-driv e n a le rts with no ne e d for ma nua l a cknowle dge me nt from the ope ra tors.
Parameters
Name Type Description
ErrorCount Integer Displays the number of errors encountered by the logical disk since the last counter reset (every 24hrs by default)
Unit: Errors
Status Text
Locator Text
Displays the overall status of the logical disk
Values: OK; Warning; Alarm
Example: “OK” or “Alarm!! This logical disk is no longer detected”
Helps to physically locate a component.
Alert Conditions
n/a
“!” = Warning
“!!” = Alarm n/a
"Sta tus" is a te x t pa ra me te r tha t de scribe s the ov e ra ll sta tus of the corre sponding de v ice or se nsor. A le rt conditions de scribe in sy mbolic te rms wha t occurs in the "Sta tus" pa ra me te r whe n thre sholds a re bre a che d: one e x cla ma tion ma rk trigge rs a wa rning; two e x cla ma tion ma rks ra ise a n a la rm.
103
SEN_HW_LOGICALDISK
BMC Performance Manager Express for Hardware
Version 2.7.17
Example
If BPM Express for Hardware detects that manufacturer-specified thresholds for the logical disk have been breached, the Status parameter will report “Warning! This logical disk is degraded/is about to fail” or “Alarm!! This logical disk is not detected anymore", or as may be the case. The history graph shows the exact details of the problem, its consequences and recommended actions.
De pe nding on y our sy ste m, a ll pa ra me te rs ma y not be use d.
SEN_HW_LOGICALDISK
104
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_LOGICALDISK
105
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_MAIN
The SEN_HW_MAIN class is responsible for the initialization of all the subclasses (i.e SEN_HW_Fan,
SEN_HW_LOGICALDISK, SEN_HW_CPU etc). This class has just one parameter called Machine Status.
Machine Status is a text parameter that reports whether the BPM Express for Hardware on the RSM is able to communicate with the targeted remote element. It detects whether or not the remote element is accessible for monitoring i.e. whether or not the remote element is up & running and can be monitored.
Values for this parameter are: “OK” and “WARNING”.
Example for OK
“<hostname> is alive. Detected as <OS>. Protocols used: (SNMP/WBEM/ Telnet/SSH)
If this parameter reports that the application cannot communicate with this host, it could be due to any of the following reasons:
A firewall prevents communication between the RSM and the managed server
The WMI layer has not been installed or is disabled (Windows only)
Neither SSH nor telnet connections are allowed on the managed server (UNIX and Linux only)
The supplied credentials are incorrect
The SNMP community string is wrong
None of the connectors match the platform of the remote element
Some examples of possible “Warning!” alerts:
The remote element is down.
Example
“<hostname> is down. Problem: Either the remote element is not currently running or the firewall is preventing access to the element.”
The remote element is up and running, but none of the connectors match the platform of the remote element.
Example
“<hostname> is alive. Problem: None of the connectors match this platform.”
The remote element is up and running, but the host platform cannot be detected.
Example
106
SEN_HW_MAIN
BMC Performance Manager Express for Hardware
Version 2.7.17
“<hostname> is alive. Problem: Host platform cannot be detected.”
On clicking on the History icon, you can see the details about the problem, its consequences and the recommended actions.
The wa rning "Ma chine Sta tus" trigge rs in ca se of a proble m, is not re la te d to a ny ha rdwa re issue ; a ll it indica te s is tha t the BPM Ex pre ss for Ha rdwa re ca nnot pe rform the de te ction, discov e ry or colle ction proce sse s on this re mote e le me nt.
If one or se v e ra l conne ctors a re not de te cte d a s v a lid for the ta rge te d se rv e r, y ou ne e d to e na ble the de bug mode of BPM Ex pre ss for Ha rdwa re a nd che ck the de bug output for the re a son tha t le d it to e x clude those conne ctors.
SEN_HW_MAIN
107
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_MAIN
108
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_MEMORY
Each instance of the SEN_HW_MEMORY module represents a memory module in the server.
The Status parameter will raise an "on the fly" alert on servers that can dynamically handle failed memory modules or, most often, for modules that have been disabled by the BIOS upon reboot (the module is then flagged as "missing").
The Error Count parameter represents the number of errors that have been fixed by ECC-enabled memory modules.
In some case, the Predicted Failure parameter is used to alert administrators that the memory module is about to fail.
The use of the Error Count, or Predicted Failure parameter depends on the technology being used to report the health of memory modules.
The "Sta tus" pa ra me te r re ports a n A la rm if the "Error C ount" pa ra me te r is gre a te r tha n ze ro (tha t is: the disk e ncounte re d some e rrors). Since the counte r is re se t e v e ry 24th hour, the corre sponding a le rt on the Sta tus pa ra me te r will a utoma tica lly be cle a re d a fte r 24 hours. This me cha nism e na ble s BPM Ex pre ss for Ha rdwa re /Porta l to re port pure e v e nt-driv e n a le rts with no ne e d for ma nua l a cknowle dge me nt from the ope ra tors.
Parameters
Name
PredictedFailure
ErrorCount
Status
Locator
Type
Text
Description
Raises an alert through the Status parameter if a memory failure is expected
Integer Displays the number of errors encountered since last counter reset (every 24hrs by default)
Unit: Errors
Text Displays the overall memory status.
Values: OK; Warning; Alarm
Example: “OK” or “Warning! This memory module encountered an abnormal number of internal errors”
Text Helps to physically locate a component.
Alert Conditions
n/a n/a
“!” = Warning
“!!” = Alarm n/a
"Sta tus" is a te x t pa ra me te r tha t de scribe s the ov e ra ll sta tus of the corre sponding de v ice or se nsor. A le rt conditions de scribe in sy mbolic te rms wha t occurs in the "Sta tus" pa ra me te r whe n thre sholds a re bre a che d: one e x cla ma tion ma rk trigge rs a wa rning; two e x cla ma tion ma rks ra ise a n a la rm.
Example
If BPM Express for Hardware detects that manufacturer-specified thresholds for the memory module have been breached, the Status parameter will report “Warning! This memory module encountered an abnormal number of internal errors” or “Alarm!! An imminent failure is predicted on this memory module”, or as may be the case. The history graph shows the exact details of the problem, its consequences and recommended actions.
109
SEN_HW_MEMORY
BMC Performance Manager Express for Hardware
Version 2.7.17
De pe nding on y our sy ste m, a ll pa ra me te rs ma y not be use d.
SEN_HW_MEMORY
110
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_MEMORY
111
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_NETWORK
Each SEN_HW_NETWORK instance represents a network adapter in the server.
The Link Status reports whether or not the adapter is properly linked to the network from a pure hardware cable perspective (it will not report a bad IP configuration for example). By default, the
Link Status parameter raises an alert (through Status) only for previously connected network adapters that are no longer linked to the network.
The Error Percent parameter represents the percentage of sent and received network packets that were in error. A high percentage of errors often means that the network link is improperly configured or that the network card is functioning erratically and thus needs to be replaced.
The Status parameter displays the overall status of the instance. It raises an alert if any of the other parameters breach their thresholds. Alerts are triggered only through the Status parameter.
Parameters
Name Type Description Alert Conditions
LinkStatus
ErrorPercent
Status
Text Triggers a warning if the network interface is not connected (i.
e. cable unplugged)
Integer Displays the percentage of transmitted and received packets in error between collects.
Text Displays the overall status of the network interface
Values: OK; Warning; Alarm
Example: “OK” or “Alarm!! This network adapter is not detected anymore” n/a
= 10 = Warning
= 30 = Alarm
“!” = Warning
“!!” = Alarm n/a n/a
ConnectionType Text
BandwidthUtiliza tion
Type of the network connection (ethernet/FC)
Numeric Percentage used of the available bandwidth.
DuplexMode Numeric Whether the port is configured to operate in half-duplex or full-duplex mode.
LinkSpeed Numeric Negotiated or configured link speed
PhysicalAddress Text The physical address of the network component
ReceivedBytes Numeric Number of received bytes (in GB)
ReceivedBytesR ate
Numeric Received network traffic in bytes per second.
n/a n/a n/a n/a n/a n/a TransmittedByte s
Numeric Number of transmitted bytes (in GB)
TransmittedByte
Rate
Numeric Emitted network traffic in megabytes per second.
Locator Text Helps to physically locate a component.
Numeric Port number to which the network card is connected.
ConnectedTo
PhysicalAddr ess n/a n/a n/a
112
SEN_HW_NETWORK
BMC Performance Manager Express for Hardware
Version 2.7.17
"Sta tus" is a te x t pa ra me te r tha t de scribe s the ov e ra ll sta tus of the corre sponding de v ice or se nsor. A le rt conditions de scribe in sy mbolic te rms wha t occurs in the pa ra me te r whe n thre sholds a re bre a che d: one e x cla ma tion ma rk trigge rs a wa rning; two e x cla ma tion ma rks ra ise a n a la rm.
Example
If BPM Express for Hardware detects that manufacturer-specified thresholds for the network interface have been breached, the Status parameter will report “Warning! This network adapter has degraded”,or, “Alarm!! This network adapter is not detected anymore” or as may be the case. The history graph shows the exact details of the problem, its consequences and recommended actions.
De pe nding on y our sy ste m, a ll pa ra me te rs ma y not be use d.
SEN_HW_NETWORK
113
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_NETWORK
114
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_OTHERDEVICE
This class is typically used to monitor devices that do not relate to the other classes and can rarely be monitored on servers. The device definition is given by the connector file and the device is monitored just as any other in any other class.
This represents hardware components that do not fall into other predefined categories i.e. other than processors, memory modules, temperature sensors, fans, voltage sensors, power supplies, network cards, disk controllers, physical disks and logical disks.
Parameters
Name
Status
Locator
Type Description
Text
Text
Displays the overall status of the "other device"
Values: OK; Warning; Alarm
Example: “OK” or “Alarm!! This device is no longer detected”
Helps to physically locate a component.
Alert Conditions
“!” = Warning
“!!” = Alarm n/a
"Sta tus" is a te x t pa ra me te r tha t de scribe s the ov e ra ll sta tus of the corre sponding de v ice or se nsor. A le rt conditions de scribe in sy mbolic te rms wha t occurs in the "Sta tus" pa ra me te r whe n thre sholds a re bre a che d: one e x cla ma tion ma rk trigge rs a wa rning; two e x cla ma tion ma rks ra ise a n a la rm.
Example
If BPM Express for Hardware detects that manufacturer-specified thresholds for the “other device” have been breached, the Status parameter will report “Alarm! This device has degraded.” or “Alarm!!
This device is no longer detected”, or as may be the case. The history graph shows the exact details of the problem, its consequences and recommended actions.
De pe nding on y our sy ste m, a ll pa ra me te rs ma y not be use d.
SEN_HW_OTHERDEVICE
115
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_OTHERDEVICE
116
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_PHYSICALDISK
Each instance of this class represents a hard drive detected on the platform by BPM Express for
Hardware. Its purpose is to monitor the status of each hard drive and possibly detect an incoming failure.
Physical disks must be monitored to avoid loss of data, un-availabilities and performance degradation.
When available, S.M.A.R.T technology will be used to predict a disk failure before it occurs. Depending on the available information, the Predicted Failure and/or Status parameters will be displayed for each discovered physical disk:
The Predicted Failure parameter uses S.M.A.R.T technology to predict physical disk failures. An alert will be triggered if it is predicted that the physical disk will soon break down. The Status parameter represents the current status of the physical disk. An alert is triggered if the physical disk is not available for proper operation.
The Error Count parameter is incremented each time an error occurs on this physical disk. An alert is raised by the Status parameter from the first detected error. The Status parameter represents the overall status of the physical disk and triggers an alert is triggered if the physical disk is not available for proper operation or if any of the other parameters breach their thresholds.
The Status parameter represents the overall status of the physical disk. It triggers an alert if the physical disk missing or if any of the other parameters have breached their thresholds. It is only
Status that will trigger and display the alerts. When all is fine, Status shows “OK”, and when there is a problem, it shows “Warning!” or “Alarm!!” with a detailed description of the issue, its consequences and recommended actions. The alert conditions for Status are: “!”=Warning;
“!!”=Alarm
The "Sta tus" pa ra me te r re ports a n A la rm if the "Error C ount" pa ra me te r is gre a te r tha n ze ro (tha t is: the disk e ncounte re d some e rrors). Since the counte r is re se t e v e ry 24th hour, the corre sponding a le rt on the "Sta tus" pa ra me te r will a utoma tica lly be cle a re d a fte r 24 hours. This me cha nism e na ble s BPM Ex pre ss for Ha rdwa re /Porta l to re port pure e v e nt-driv e n a le rts with no ne e d for ma nua l a cknowle dge me nt from the ope ra tors.
Parameters
Name Type Description
PredictedFailure Text
ErrorCount Integer
Triggers information if a failure is expected
Displays the number of errors encountered by the physical disk.
Unit: errors
Status Text
Locator Text
Displays the overall status of the physical disk
Values: OK; Warning; Alarm
Example: “OK” or “Alarm!! This disk is not detected anymore”
Helps to physically locate a component.
Alert Conditions
n/a n/a
“!” = Warning
“!!” = Alarm n/a
"Sta tus" is a te x t pa ra me te r tha t de scribe s the ov e ra ll sta tus of the corre sponding de v ice or se nsor. A le rt conditions de scribe in sy mbolic te rms wha t occurs in the "Sta tus" pa ra me te r whe n thre sholds a re bre a che d: one e x cla ma tion ma rk trigge rs a wa rning; two e x cla ma tion ma rks ra ise a n a la rm.
117
SEN_HW_PHYSICALDISK
BMC Performance Manager Express for Hardware
Version 2.7.17
Example
If BPM Express for Hardware detects that manufacturer-specified thresholds for the physical disk have been breached, the Status parameter will report “Warning! This physical disk is degraded/is about to fail” or “Alarm! This disk is not detected anymore", or as the case may be. The history graph shows the exact details of the problem, its consequences and recommended actions.
De pe nding on y our sy ste m, a ll pa ra me te rs ma y not be use d.
SEN_HW_PHYSICALDISK
118
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_PHYSICALDISK
119
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_POWERSUPPLY
Each instance of this class represents a power supply in the system. It is used to monitor their status and to indicate when a power supply is malfunctioning and needs attention.
Power supply is critical and should never fail, which is why servers often have redundant power supplies. Monitoring power supplies allows the operators to be alerted when a power supply fails, or in some cases when a power supply is overloaded. Depending on the information available, the Used
Capacity and/or Status parameters will be displayed for each power supply or power unit device:
The Used Capacity parameter represents the power supply’s power currently in use in percentage.
An alert is triggered if the computer uses too much power than it can be supplied.
The Status parameter represents the current status of the power supply. An alert is triggered if an error occurs with the power supply.
Parameters
Name
UsedCapacity
Status
Locator
Type Description
Integer Displays the percentage of the power supply currently in use
Unit: Percentage (%)
Text Displays the overall status of the power supply
Values: OK; Warning; Alarm
Example: “OK” or “Alarm!! The power consumed by the system is out of the supported range"
Text Helps to physically locate a component.
Alert Conditions
n/a
“!” = Warning
“!!” = Alarm n/a
"Sta tus" is a te x t pa ra me te r tha t de scribe s the ov e ra ll sta tus of the corre sponding de v ice or se nsor. A le rt conditions de scribe in sy mbolic te rms wha t occurs in the "Sta tus" pa ra me te r whe n thre sholds a re bre a che d: one e x cla ma tion ma rk trigge rs a wa rning; two e x cla ma tion ma rks ra ise a n a la rm.
Example
If BPM Express for Hardware detects that manufacturer-specified thresholds for power supply have been breached, the Status parameter will report “Warning! Problem: This power supply is in degraded state, or about to fail” or “Alarm!! The power consumed by the system is out of the supported range", or as may be the case. The history graph shows the exact details of the problem, its consequences and recommended actions.
De pe nding on y our sy ste m, a ll pa ra me te rs ma y not be use d.
120
SEN_HW_POWERSUPPLY
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_POWERSUPPLY
121
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_ROBOTICS
SEN_HW_ROBOTICS can be a child of SEN_HW_ENCLOSURE only.
Parameters
Name
Status
Type Description
Text Device status.
Values: OK; Warning; Alarm
Numeric Number of moves performed by the robot.
MoveCount
(Cumulative)
Locator Text Helps to physically locate a component.
Alert Conditions
“!” = Warning
“!!” = Alarm n/a n/a
SEN_HW_ROBOTICS
122
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_ROBOTICS
123
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_TAPEDRIVE
SEN_HW_TAPEDRIVE can be a child of SEN_HW_ENCLOSURE and SEN_HW_DISKCONTROLLER.
Parameters
Name Type Description
Status Text Device status.
Values: OK; Warning; Alarm
No / Yes NeedsCleaning Text
MountCount Numeric Number of mounts
UnmountCount Numeric Number of unmounts
Locator Text Helps to physically locate a component.
Alert Conditions
“!” = Warning
“!!” = Alarm n/a n/a n/a n/a
SEN_HW_TAPEDRIVE
124
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_TAPEDRIVE
125
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_TEMPERATURE
BPM Express for Hardware detects the temperature probes on the motherboard or devices and creates an instance of this class for each of them. Their location in the platform is described in the instance’s label if it is available.
When a temperature reading can be performed, temperature thresholds are automatically set and an alert will be triggered if the temperature rises to a dangerous level. Even in the case that no reading can made, the Status parameter will display the condition of the temperature in the system.
Parameters
Name
Temperature
Status
Locator
Type
Integer
Text
Text
Description
Displays the temperature reading
Unit: Celsius degrees (C°)
Displays the overall temperature status
Values: OK; Warning; Alarm
Example: “OK” or “Alarm!! The temperature is critically high”
Helps to physically locate a component.
n/a
Alert Conditions
n/a
“!” = Warning
“!!” = Alarm
"Sta tus" is a te x t pa ra me te r which de scribe s the ov e ra ll sta tus of the corre sponding de v ice or se nsor. A n a le rt condition de scribe s in sy mbolic te rms wha t occurs whe n thre sholds a re bre a che d.
Example
If BPM Express for Hardware detects that manufacturer-specified thresholds have been breached for temperature, the Status parameter will report “Warning! The temperature is too high (67°C)” or,
“Alarm!! The temperature is critically high” or, as may be the case. There is a complete hardware health report for this temperature sensor. The actual temperature value (when available) is reported by the Temperature parameter but alert thresholds are not directly set on this parameter. The history graph will display details about the problem, its consequences and the recommended actions.
De pe nding on y our sy ste m, a ll pa ra me te rs ma y not be use d.
SEN_HW_TEMPERATURE
126
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_TEMPERATURE
127
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_VOLTAGE
The purpose of this class is to monitor power supply voltages. For each voltage sensor (+5V, +12V, -5V, etc.), an instance is created in a container with a label describing its type.
If the computer’s configuration allows a reading of the voltages, the values will be available in the
Voltage parameter and an alert will be triggered if they do not meet the automatically set thresholds.
Otherwise, the Status parameter will inform you if a problem occurs with one of the voltages.
Parameters
Name Type
Voltage Integer
Status Text
Locator Text
Description
Displays the voltage reading
Unit : mV
Displays the overall status of the voltage
Values: OK; Warning; Alarm
Example: “OK” or “Alarm!! This voltage sensor is no longer detected"
Helps to physically locate a component.
Alert Conditions
n/a
“!” = Warning
“!!” = Alarm n/a
"Sta tus" is a te x t pa ra me te r tha t de scribe s the ov e ra ll sta tus of the corre sponding de v ice or se nsor. A le rt conditions de scribe in sy mbolic te rms wha t occurs in the "Sta tus" pa ra me te r whe n thre sholds a re bre a che d: one e x cla ma tion ma rk trigge rs a wa rning; two e x cla ma tion ma rks ra ise a n a la rm.
Example
If BPM Express for Hardware detects that manufacturer-specified thresholds for voltage have been breached, the Status parameter will report “Warning! Although still not critical, the voltage level is out of the normal range." or “Alarm!! This voltage sensor is no longer detected", or as may be the case.
The history graph shows the exact details of the problem, its consequences and recommended actions.
De pe nding on y our sy ste m, a ll pa ra me te rs ma y not be use d.
SEN_HW_VOLTAGE
128
BMC Performance Manager Express for Hardware
Version 2.7.17
SEN_HW_VOLTAGE
129
BMC Performance Manager Express for Hardware
Version 2.7.17
Special Note on Application
Collection Status
This parameter is created by default by the Portal for every application class that is added. Hence when you add BPM Express for Hardware on an element, you will see this parameter. The parameter has
Boolean values: True or False
True indicates that BPM Express for Hardware is functioning
False indicates that it is not
Special Note on Application Collection Status
130
BMC Performance Manager Express for Hardware
Version 2.7.17
Thresholds
BPM Express for Hardware dynamically sets the thresholds on all of its parameters depending on the platform it is running on. This is why a recapitulative table of the alert thresholds of BPM Express for
Hardware cannot be provided. It takes the manufacturer-set thresholds for each component and sets alert rules accordingly.
As you have seen in the previous section, it is Status, the text parameter that displays alert conditions.
BPM Express for Hardware assigns the pre-set thresholds to its symbolic conditions of exclamation marks.
For instance, when a manufacturer-set threshold reaches warning levels, BPM Express for Hardware translates it to “Warning!” with one exclamation mark, which triggers a Warning alert in the Portal; and for an alarm-level breach, the Status parameter is set to “Alarm!!” with two exclamation marks, which triggers an Alarm alert in the Portal. When a problem occurs, it is the Status parameter that reports
“WARNING!” or “ALARM!!” followed by a full description of the encountered problem, the possible consequences and the recommended action. Nevertheless, it is possible to modify these pre-set thresholds via the Configure tab.
If y ou wish to modify pre -se t thre sholds of indiv idua l pa ra me te rs, y ou must de a ctiv a te the thre sholds for the Sta tus pa ra me te r (which will othe rwise continue to conside r pre -se t thre sholds a nd trigge r a le rts a ccordingly ), a nd inste a d, dire ctly a ssign thre shold v a lue s a ga inst indiv idua l pa ra me te rs of the cla ss. Se e the Use r Guide for de ta ils.
Thresholds
131
BMC Performance Manager Express for Hardware
Version 2.7.17
Additional Configuration Properties
This section provides detailed information on how to override the default property values used within
BPM Express for Hardware. These values have to be defined in the rsmcfg.properties (%RSM_HOME%
\ RSMxx\server\rsm\conf\properties\rsm\ rsmcfg.properties) file.
The following properties may be set to override the default values for a specific element or for all elements at once.
SSH Timeout
This property allows you to override the default timeout value or the default connector specified timeout value for executing a single command using SSH. The default value is 45 seconds.
Property: net.sentrysoftware.bpm.hardware.sshTimeout.default=45000
Example
To set the value for all hosts: net.sentrysoftware.bpm.hardware.sshTimeout.default=45000
To set the value for a specific host: net.sentrysoftware.bpm.hardware.sshTimeout.default.
<hostname>=45000
To override the connector specified timeout value:
Property: net.sentrysoftware.bpm.hardware.sshTimeout.hdf=60000
Example
To set the value for all hosts: net.sentrysoftware.bpm.hardware.sshTimeout.hdf=60000
To set the value for a specific host: net.sentrysoftware.bpm.hardware.sshTimeout.hdf.
<hostname>=60000
The < hostna me > ta g must be re pla ce d with EXA C TLY the hostna me or IP a ddre ss e nte re d whe n a dding the e le me nt
Telnet timeout
This property allows you to override the default timeout value or the default connector specified timeout value for executing a single command using Telnet. The default value is 45 seconds.
132
Additional Configuration Properties
BMC Performance Manager Express for Hardware
Version 2.7.17
Property: net.sentrysoftware.bpm.hardware.telnetTimeout.default=45000*
To override the connector specified timeout value:
Property: net.sentrysoftware.bpm.hardware.telnetTimeout.hdf=60000
WMI timeout
This property allows you to override the default timeout value for executing a single WMI query. The default value is 45 seconds.
Property: net.sentrysoftware.bpm.hardware.wmiTimeout.default=45000
WBEM timeout
This property allows you to override the default timeout value for executing a single WBEM query. The default value is 45 seconds.
Property: net.sentrysoftware.bpm.hardware.wbemTimeout.default=45000
WMI namespace
This property allows you to specify the namespace that is to be used for executing the WMI query.
Property: net.sentrysoftware.bpm.hardware.wmiNamespace=root\cimv2
WBEM namespace
This property allows you to specify the namespace that is to be used for executing the WBEM query.
Property: net.sentrysoftware.bpm.hardware.wbemNamespace=root
Force Telnet
If an element responds to both Telnet and SSH, by default BPM Express for Hardware uses SSH. This property can be set to “true” in order to force Telnet over SSH.
Property: net.sentrysoftware.bpm.hardware.forceTelnet=true
Force SSH
This property is used to specify BPM Express for Hardware to use SSH.
Property: net.sentrysoftware.bpm.hardware.forceSSH=true
Force WMI Script
By default BPM Express for Hardware uses the WMI class of BMC portal sdk to perform wmi requests.
Setting this property value to “true” will force BPM Express for Hardware to use WMI Script to perform
Additional Configuration Properties
133
BMC Performance Manager Express for Hardware
Version 2.7.17
wmi requests.
Property: net.sentrysoftware.bpm.hardware.forceWMIScript=true
Force nAwk
By default BPM Express for Hardware uses the java native awk method to parse the result. Setting this property value to “true” will force BPM Express for Hardware to use nAwk to parse the result.
Property: net.sentrysoftware.bpm.hardware.forcenawk=true
Reflect Fan Speed value
By default in the class SEN_HW_FAN, BPM Express for Hardware sets the parameter “Status” in alert if the parameter “Speed” exceeds the threshold value. Setting this property value to “false” will force BPM
Express for Hardware not to reflect the threshold values on parameter “Status”.
Property: net.sentrysoftware.bpm.hardware.fan.speed=false
Reflect PowerSupply UsedCapacity value
By default in the class SEN_HW_POWERSUPPLY, BPM Express for Hardware sets the parameter
“Status” in alert if the parameter “UsedCapacity” exceeds the threshold value. Setting this property value to “false” will force BPM Express for Hardware not to reflect the threshold values on parameter
“Status”.
Property: net.sentrysoftware.bpm.hardware.powersupply.usedcapacity=false
Reflect Voltage value
By default in the class SEN_HW_VOLTAGE, BPM Express for Hardware sets the parameter “Status” in alert if the parameter “Voltage” exceeds the threshold value. Setting this property value to “false” will force BPM Express for Hardware not to reflect the threshold values on parameter “Status”.
Property: net.sentrysoftware.bpm.hardware.volt.voltage=false
Reflect Temperature value
By default in the class SEN_HW_TEMPERATURE, BPM Express for Hardware sets the parameter
“Status” in alert if the parameter “Temperature” exceeds the threshold value. Setting this property value to “false” will force BPM Express for Hardware not to reflect the threshold values on parameter “Status”.
Property: net.sentrysoftware.bpm.hardware.temp.temperature=false
SNMP Port
BPM Express for Hardware uses the default Port 161 for SNMP requests. This port number can be overriden by setting this property value in the rsmcfg.properties file.
Property: net.sentrysoftware.bpm.hardware.snmp.port=161
SSH Port
BPM Express for Hardware uses the default Port 22 for SSH requests. This port number can be overriden by setting this property value in the rsmcfg.properties file.
Property: net.sentrysoftware.bpm.hardware.ssh.port=22
Telnet Port
BPM Express for Hardware uses the default Port 23 for Telnet requests. This port number can be overriden by setting this property value in the rsmcfg.properties file.
Additional Configuration Properties
134
BMC Performance Manager Express for Hardware
Version 2.7.17
Property: net.sentrysoftware.bpm.hardware.telnet.port=23
WBEM Activation
Option to activate the WBEM protocol is added by setting a value in the rsmcfg.properties file.
Properties: net.sentrysoftware.bpm.hardware.wbemActivation=true;true
Pre-Selected Connectors
This property will force Hardware Express to perform detection process only on the specified connector files for a specified element.
Property: net.sentrysoftware.bpm.hardware.preSelectedConnectors.hostname=connector1.hdf, connector2.hdf,connector3.hdf
Additional Configuration Properties
135
BMC Performance Manager Express for Hardware
Version 2.7.17
Connectors
This section deals with connectors provided with this version of BPM Express for Hardware.
A table provides a quick overview of the connectors as well as their corresponding filenames and applicable environments (i.e. type of computers, servers, operating systems).
Connector and Platform Reference Table
The following table shows all the connectors provided with this versions of BPM Express for Hardware.
Each connector is a file with the .hdf extension and they are stored in: %RSM_HOME%
\RSMxx\server\rsm\tmp\deploy directory.
Connector Name
Adaptec Storage Manager Web Edition
Operating
System
Microsoft
Windows,
Linux
Microsoft
Windows,
Linux
Typical platform
Fujitsu-Siemens
PRIMERGY
Fujitsu-Siemens
PRIMERGY
Microsoft
Windows,
Linux
Fujitsu-Siemens
PRIMERGY
Storage Device SAN
Storage Device DDN Disk Array
Connector File
SEN_HW_DptStorageManager.hdf
SEN_HW_AAC.hdf
SEN_HW_IOManager.hdf
Cisco MDS9000 Series - SSH/Telnet
DataDirect Networks (DDN) Disk Array -
Dell CMC (Dell Chassis Management
Dell DRAC/MC (Dell Remote Access
N/A
N/A
Dell M1000E
Chassis
Dell PowerEdge
SEN_HW_CiscoTelnet.hdf
SEN_HW_DDN.hdf
SEN_HW_DellCMC.hdf
SEN_HW_DellDRACMC.hdf
Dell OpenManage Server Administrator
Dell OpenManage Storage Manager
Fibre Alliance SNMP Agent (Switches)
Fujitsu-Siemens Management Blade (FSC
Microsoft
Windows,
Linux
Microsoft
Windows,
Linux
Microsoft
Windows,
Linux
Dell PowerEdge
Dell PowerEdge
Dell PowerEdge
SEN_HW_DellArrayManager.hdf
SEN_HW_DellOpenManage.hdf
SEN_HW_DellStorageManager.hdf
Storage Device SAN Switches
N/A Fujitsu-Siemens BX
Blade Servers
Microsoft
Windows,
Linux
Fujitsu-Siemens
PRIMERGY
SEN_HW_FibreAllianceSwitch.hdf
SEN_HW_FujitsuSiemensBlade.hdf
SEN_HW_ServerviewNT.hdf
136
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Connector Name
Fujitsu-Siemens ServerView RAID Agent
HP Insight Management Agent - Drive
HP Insight Management Agent - HBA
HP Insight Management Agent - IDE
HP Insight Management Agent - iLO
HP Insight Management Agent - SCSI
HP Insight Management Agent - Server
HP Insight Management Agent – Server –
HP Insight Management Agent - Server
HP Insight Management Agent- Fiber
Operating
System
Typical platform
Microsoft
Windows,
Linux, HP
Tru64, HP
OpenVMS, Sun
Solaris
Microsoft
Windows,
Linux, HP
OpenVMS, HP
Tru64, Sun
Solaris
Microsoft
Windows,
Linux, HP
Tru64, HP
OpenVMS, Sun
Solaris
Microsoft
Windows,
Linux, HP
Tru64, HP
OpenVMS, Sun
Solaris
Microsoft
Windows,
Linux
Microsoft
Windows,
Linux
N/A
Microsoft
Windows,
Linux, HP
OpenVMS, HP
Tru64, Sun
Solaris
Microsoft
Windows,
Linux, HP
Tru64, HP
OpenVMS, Sun
Solaris
Microsoft
Windows
HP Tru64, HP
OpenVMS
Microsoft
Windows,
Linux, HP
Tru64, HP
OpenVMS, Sun
Solaris
Fujitsu-Siemens
PRIMERGY
HP BladeSystem
HP BladeSystem
HP ProLiant
HP ProLiant
HP ProLiant
HP ProLiant
HP ProLiant
HP ProLiant
HP ProLiant
HP ProLiant
HP ProLiant
Connector File
SEN_HW_FscRaid.hdf
SEN_HW_HPBladeSystem.hdf
SEN_HW_HPBladeTelnet.hdf
SEN_HW_CpqDriveArrayNT.hdf
SEN_HW_CpqHBA.hdf
SEN_HW_CpqIDEDriveArray.hdf
SEN_HW_CpMgSm2.hdf
SEN_HW_CpqSCSIDriveArray.hdf
SEN_HW_CpMgServNT.hdf
SEN_HW_HPInsightwmi.hdf
SEN_HW_CpMgServTru64.hdf
SEN_HW_CpqFCADriveArray.hdf
Connectors
137
BMC Performance Manager Express for Hardware
Version 2.7.17
Connector Name
IBM BladeCenter Management Module
IBM Director Agent 3.x - Windows
IBM Director Agent 4.x - Linux
IBM Director Agent 4.x - Windows
IBM Director Agent 5.10.x - Linux
IBM Director Agent 5.10.x - Windows
Operating
System
N/A
Typical platform
HP 9000,
Integrity,
SuperDome
HP NetServer Microsoft
Windows
Linux,
Microsoft
Windows
HP-UX
HP NetServer
HP-UX
HP-UX
HP-UX
HP-UX
IBM AIX
IBM AIX
IBM AIX
IBM AIX
IBM AIX
N/A
Microsoft
Windows
Linux
Microsoft
Windows
Linux
Microsoft
Windows
Connector File
SEN_HW_HPiLO.hdf
SEN_HW_HPTopToolsNT.hdf
SEN_HW_HpNetRaidController.hdf
HP 9000, HP
Integrity, HP
SuperDome
HP 9000, HP
Integrity, HP
SuperDome
HP 9000, HP
Integrity, HP
SuperDome
HP 9000, HP
Integrity, HP
SuperDome
HP 9000, HP
Integrity, HP
SuperDome
IBM RS/6000, IBM pSeries,
IBM eServer p5
IBM RS/6000, IBM pSeries,
IBM eServer p5
IBM RS/6000, IBM pSeries,
IBM eServer p5
IBM RS/6000, IBM pSeries, IBM eServer p5
IBM RS/6000, IBM pSeries,
IBM eServer p5
IBM BladeCenter
IBM xSeries, IBM
Netfinity
IBM xSeries, IBM
Netfinity
IBM xSeries, IBM
Netfinity
IBM xSeries, IBM
Netfinity
IBM xSeries, IBM
Netfinity
SEN_HW_HPUX.hdf
SEN_HW_HPUXDisk.hdf
SEN_HW_HPUXNetwork.hdf
SEN_HW_HPUXSasMgr.hdf
SEN_HW_HPUXStm.hdf
SEN_HW_IBMAIXChrpMachstat.hdf
SEN_HW_IBMAIX.hdf
SEN_HW_IBMAIXUeSensor.hdf
SEN_HW_IBMAIXHBA.hdf
SEN_HW_IBMAIXDisk.hdf
SEN_HW_IBMBlade.hdf
SEN_HW_Director3NT.hdf
SEN_HW_Director4Linux.hdf
SEN_HW_Director4NT.hdf
SEN_HW_Director5Linux.hdf
SEN_HW_Director5NT.hdf
Connectors
138
BMC Performance Manager Express for Hardware
Version 2.7.17
Connector Name
IBM Director Agent 5.20.x - Linux
IBM Director Agent 5.20.x - ServeRAID -
IBM Director Agent 5.20.x - ServeRAID -
IBM Director Agent 5.20.x - Windows
IBM Netfinity Manager 5.20.x - Basic
IBM Netfinity Manager 5.20.x - Disks
IBM Netfinity Manager 5.20.x -Normal
LSI 1030-based GAM Server (Alternate
LSI Logic - LsiUtil – RAID (Windows)
LSI Logic MegaRAID PowerConsole
MIB-2 Standard SNMP Agent - Network
Operating
System
Linux
Linux
Microsoft
Windows
Microsoft
Windows
Microsoft
Windows
Microsoft
Windows
Microsoft
Windows
Linux, Sun
Solaris
Linux
Typical platform
IBM xSeries, IBM
Netfinity
IBM xSeries, IBM
Netfinity
IBM xSeries, IBM
Netfinity
IBM xSeries, IBM
Netfinity
IBM Netfinity
IBM Netfinity
IBM Netfinity
Sun Fire (x64)
Connector File
SEN_HW_Director52Linux.hdf
SEN_HW_Director52ServeRAIDLinux.
hdf
SEN_HW_Director52ServeRAIDNT.
hdf
SEN_HW_Director52NT.hdf
SEN_HW_IbmNetfinityManagerBASIC
.hdf
SEN_HW_IbmNetfinityManagerRAID.
hdf
SEN_HW_IbmNetfinityManager.hdf
SEN_HW_IpmiTool.hdf
Dell PowerEdge,
HP ProLiant,
Fujitsu-Siemens
PRIMERGY, IBM xSeries, Sun Fire
Fujitsu-Siemens
PRIMERGY
SEN_HW_LinuxNetwork.hdf
Microsoft
Windows,
Linux
Microsoft
Windows,
Linux
Microsoft
Windows
Fujitsu-Siemens
PRIMERGY
SEN_HW_LSI1030.hdf
SEN_HW_LSI1030Alt.hdf
Linux, Sun
Solaris
Microsoft
Windows,
Linux
Microsoft
Windows,
Linux
Microsoft
Windows,
Linux
Microsoft
Windows,
Linux
Network, HP-
UX, Storage
Device, HP
OpenVMS, HP
Tru64
Windows servers equipped with an
LSI RAID controller
Sun Fire (x64)
SEN_HW_LSIUtilWindows.hdf
SEN_HW_LSIUtilUNIX.hdf
Fujitsu-Siemens
PRIMERGY
Fujitsu-Siemens
PRIMERGY
Fujitsu-Siemens
PRIMERGY
Fujitsu-Siemens
PRIMERGY
Any SNMPinstrumented device
SEN_HW_MegaRaidPowerConsole.
hdf
SEN_HW_MylexController.hdf
SEN_HW_LSIMegaRaidSAS.hdf
SEN_HW_LSIMegaRaidSAS5.hdf
SEN_HW_MIB2.hdf
Connectors
139
BMC Performance Manager Express for Hardware
Version 2.7.17
Connector Name
MIB-2 Standard SNMP Agent - Network
MIB-2 Standard SNMP Agent - Network
MIB-2 Standard SNMP Agent - Network
IBM DS (LSI) Disk Arrays (smcli)
SMI-S Compliant Storage Libraries
Operating
System
Typical platform
Connector File
Linux
Microsoft
Windows
Any SNMPinstrumented device
Any SNMPinstrumented device
SEN_HW_MIB2Linux.hdf
SEN_HW_MIB2NT.hdf
Sun Solaris Any SNMPinstrumented device
No-name PC
SEN_HW_MIB2Solaris.hdf
Microsoft
Windows
Microsoft
Windows,
Linux
NEC Express5800
Storage Device Disk Array
Microsoft
Windows,
Linux
Fujitsu-Siemens
PRIMERGY
SEN_HW_MBMNT.hdf
SEN_HW_NECEsmPro.hdf
SEN_HW_NetApp.hdf
SEN_HW_PromiseFSC.hdf
SEN_HW_QuantumTapeLibrary.hdf
SEN_HW_SmartMonLinux.hdf
Storage Device Tape Library
Linux Dell PowerEdge,
Fujitsu-Siemens
PRIMERGY, HP
ProLiant,
IBM xSeries, Sun
Fire (x64)
Storage Device IBM DS Storage
Systems
Disk Array Storage
Device,
Microsoft
Windows,
Linux
Microsoft
Windows,
Linux, IBM
AIX, HP-UX,
Tru64, HP
OpenVMS, Sun
Solaris
Server with HBAs
SEN_HW_smcli.hdf
SEN_HW_SMISDiskArray.hdf
SEN_HW_SMISHBA.hdf
Storage
Device,
Microsoft
Windows,
Linux
Storage
Device,
Microsoft
Windows,
Linux
SAN Switches
Storage Libraries
SEN_HW_SMISSwitch.hdf
SEN_HW_SMISLibrary.hdf
Connectors
140
BMC Performance Manager Express for Hardware
Version 2.7.17
Connector Name
StorageTek LSeries Tape Library
StorageTek StreamLine Tape Library
Sun Advanced Lights-Out Management
Sun Fire F12K/F15K/F20K/F25K (SMS)
Sun Solaris - SPARC T1/T2 Processors
N/A
Sun Solaris
Sun Solaris
N/A
N/A
Sun Solaris - Environment (ALOM-CMT snapshot)
Sun Solaris - Environment (prtdiag, lom)
Sun Solaris - Environment (prtpicl)
Sun Solaris - Fault Manager (Memory)
Sun Solaris - Processors (psrinfo)
Sun Solaris - RAID Disks (Raidctl)
Sun Solaris
Sun Solaris
Sun Solaris
Sun Solaris
Sun Solaris
Sun Solaris
Sun Solaris
Sun Solaris
Sun Solaris
Operating
System
Typical platform
Connector File
Storage
Device,
Microsoft
Windows
Tape Library SEN_HW_SNIALibrary.hdf
Storage Device StorageTek LSeries SEN_HW_StorageTekLSeries.hdf
Storage Device StorageTek
StreamLine
SEN_HW_StorageTekStreamLine.hdf
N/A Sun Fire (SPARC) SEN_HW_SunAlom.hdf
Sun Solaris
Sun Solaris
Sun Solaris
N/A
Microsoft
Windows
Microsoft
Windows
SUN Blade Chassis SEN_HW_SunBladeChassis.hdf
Sun Fire (SPARC) SEN_HW_SunF15K.hdf
Sun Fire (SPARC) SEN_HW_SunXscf.hdf
SUN Blade with
ILOM cards
SEN_HW_SunILOMSNMP.hdf
SEN_HW_SunILOMSSH.hdf
SUN Blade with
ILOM cards
Sun Fire (SPARC
T1/T2)
SEN_HW_SunScSnapshot.hdf
Sun Fire (SPARC) SEN_HW_SunPrtdiag.hdf
Sun Fire (SPARC) SEN_HW_SunPrtpicl.hdf
Sun Fire (SPARC) SEN_HW_SunFmadm.hdf
Sun Fire (SPARC) SEN_HW_SunCediag.hdf
Sun Fire (SPARC) SEN_HW_SunNetwork.hdf
Sun Fire (SPARC) SEN_HW_SunIostatNonSun.hdf
Sun Fire (SPARC) SEN_HW_SunPsrinfo.hdf
All Sun Platforms with Hardware
Raid Controllers
SEN_HW_SunRaidctl.hdf
Sun Fire (SPARC) SEN_HW_SunTapeDrives.hdf
Sun Fire (SPARC
T1, T2)
SEN_HW_SunPsrinfoT1.hdf
Sun Fire (SPARC) SEN_HW_SunIostat.hdf
VMware ESXi SEN_HW_VMwareESXi.hdf
SEN_HW_GenBatteryNT.htm
Any Windows platform
Dell PowerEdge,
Fujitsu-Siemens
PRIMERGY, HP
ProLiant,
IBM xSeries, NEC
Express5800, Sun
Fire (x64)
SEN_HW_WBEMGenDiskNT.hdf
Connectors
141
BMC Performance Manager Express for Hardware
Version 2.7.17
Connector Name
Operating
System
Microsoft
Windows
Typical platform
Dell PowerEdge,
Fujitsu-Siemens
PRIMERGY, HP
ProLiant,
IBM xSeries, NEC
Express5800, Sun
Fire (x64)
Connector File
SEN_HW_WBEMGenNetwork.hdf
Connector Details
This section provides detailed information on each connectors - stating the target, typical platforms, the pre-requisites for
BPM Express for Hardware to function optimally, technology used, and what it will discover
(stating precise application class names) and then, most importantly, what it will monitor.
In order to know all about the connectors for your systems, first identify your platforms/environments in the reference table, and then read the corresponding details.
Adaptec IOManager
This connector provides disk monitoring through the Adaptec IO Manager SNMP sub-agent which supports a few AAC-based Adaptec RAID controllers.
Target
Typical platform: Fujitsu-Siemens PRIMERGY
Operating systems: Microsoft Windows, Linux
Instrumentation layer: Adaptec IOManager
Technology used: SNMP
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Parameters collected
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
SEN_HW_PHYSICALDISK / PredictedFailure
142
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Adaptec Storage Manager (DPT)
This connector provides disk monitoring through the Adaptec Storage Manager SNMP sub-agent which supports all DPT-based Adaptec RAID controllers.
Target
Typical platform: Fujitsu-Siemens PRIMERGY
Operating systems: Microsoft Windows, Linux
Instrumentation layer: Adaptec Storage Manager
Technology used: SNMP
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Parameters collected
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
SEN_HW_PHYSICALDISK / PredictedFailure
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
Adaptec Storage Manager Web Edition (AAC)
This connector provides disk monitoring through the Adaptec Storage Manager Web Edition SNMP subagent which supports all AAC-based Adaptec RAID controllers.
Target
Typical platform: Fujitsu-Siemens PRIMERGY
Operating system: Microsoft Windows, Linux
Instrumentation layer: Adaptec Storage Manager Web Edition
Technology used: SNMP
143
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Parameters collected
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
SEN_HW_PHYSICALDISK / PredictedFailure
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
Cisco MDS9000 Series - SSH/Telnet
This connector discovers the enclosure and fiber-channel ports of SAN switches as well as the various environment sensors (temperatures, fans, power supplies, etc.).
Target
Typical platform(s): Cisco MDS9000 Series FC switches
Operating system(s): Storage Device
Instrumentation layer: Commands on the Cisco Bay Controller
Technology used: Telnet/SSH
Discovered objects
Fans (SEN_HW_FAN)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Blades (SEN_HW_BLADE)
Other devices (SEN_HW_OTHERDEVICE)
Network cards (SEN_HW_NETWORK)
Enclosure model (SEN_HW_ENCLOSURE)
144
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Collected parameters
SEN_HW_FAN / Status
SEN_HW_TEMPERATURE / Status
SEN_HW_TEMPERATURE / Temperature
SEN_HW_POWERSUPPLY / Status
SEN_HW_BLADE / Status
SEN_HW_OTHERDEVICE / Status
SEN_HW_NETWORK / LinkStatus
SEN_HW_NETWORK / ErrorCount
SEN_HW_NETWORK / TransmittedPacketsRate
SEN_HW_NETWORK / ReceivedPacketsRate
SEN_HW_NETWORK / TransmittedBytesRate
SEN_HW_NETWORK / ReceivedBytesRate
SEN_HW_NETWORK / LinkSpeed
SEN_HW_NETWORK / DuplexMode
SEN_HW_ENCLOSURE / powerconsumption
This conne ctor ta rge ts re mote de v ice s only .
DataDirect Networks (DDN) Disk Array - SNMP
Agent
This connector monitors the HBA cards present in an HP Proliant system by connecting to the HP Insight
Management agent.
Target
Typical platform(s): HP Proliant
Operating system(s): Microsoft Windows, Linux, HP Tru64, HP OpenVMS
Instrumentation layer: HP Insight Management Agents
Technology used: SNMP
Connectors
145
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Other devices (SEN_HW_OTHERDEVICE)
Collected parameters
SEN_HW_OTHERDEVICE / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
Dell OpenManage Array Manager
This connector provides disks monitoring through the Dell OpenManage Array Manager SNMP agent (not to be confused with Storage Manager).
Target
Typical platform: Dell PowerEdge
Operating system(s): Microsoft Windows, Linux
Instrumentation layer: Dell OpenManage Server Administrator
Technology used: SNMP
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Parameters collected
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
Connectors
146
BMC Performance Manager Express for Hardware
Version 2.7.17
Dell DRAC/MC (Dell Remote Access
Controller/Modular Chassis)
This connector provides environmental information (temperatures, fans and power supplies) on Dell
Blade servers through the Dell Remote Access Controller/Modular Chassis (DRAC/MC)
Target
Typical platform: Dell PowerEdge
Operating system: N/A
Instrumentation layer: Dell Remote Access Controller/Modular Chassis (DRAC/MC)
Technology used: Telnet/SSH
Discovered objects
Blades (SEN_HW_BLADE)
Enclosure model (SEN_HW_ENCLOSURE)
Fans (SEN_HW_FAN)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Other devices (SEN_HW_OTHERDEVICE)
Parameters collected
SEN_HW_BLADE / Status
SEN_HW_ENCLOSURE / Status
SEN_HW_ENCLOSURE / PowerConsumption
SEN_HW_FAN / Speed
SEN_HW_FAN / Status
SEN_HW_TEMPERATURE / Temperature
SEN_HW_TEMPERATURE / Status
SEN_HW_POWERSUPPLY / Status
SEN_HW_OTHERDEVICE / Status
This conne ctor ta rge ts re mote de v ice s only .
147
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Dell CMC (Dell Chassis Management Controller)
Provides environmental information (temperatures, fans and power supplies) on Dell Blade servers through the Dell Chassis Management Controller (CMC).
Target
Typical platform(s): Dell M1000E Chassis
Operating system(s): N/A
Instrumentation layer: Dell Chassis Management Controller (CMC)
Technology used: Telnet/SSH
Discovered objects
Fans (SEN_HW_FAN)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Other devices (SEN_HW_OTHERDEVICE)
Enclosure model (SEN_HW_ENCLOSURE)
Collected parameters
SEN_HW_FAN / Speed
SEN_HW_FAN / Status
SEN_HW_TEMPERATURE / Temperature
SEN_HW_TEMPERATURE / Status
SEN_HW_POWERSUPPLY / Status
SEN_HW_OTHERDEVICE / Status
SEN_HW_ENCLOSURE / Status
SEN_HW_ENCLOSURE / PowerConsumption
This conne ctor ta rge ts re mote de v ice s only .
Connectors
148
BMC Performance Manager Express for Hardware
Version 2.7.17
Dell OpenManage Server Administrator
This connector provides hardware monitoring through the Dell OpenManage Server Administrator SNMP agent which supports almost all DELL PowerEdge servers.
Target
Typical platform: Dell PowerEdge
Operating systems: Microsoft Windows, Linux
Instrumentation layer: Dell OpenManage Server Administrator
Technology used: SNMP
Discovered objects
Fans (SEN_HW_FAN)
Voltage sensors (SEN_HW_VOLTAGE)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Other devices (SEN_HW_OTHERDEVICE)
Memory modules (SEN_HW_MEMORY)
Processors (SEN_HW_CPU)
Enclosure model (SEN_HW_ENCLOSURE)
Parameters collected
SEN_HW_FAN / Status
SEN_HW_FAN / Speed
SEN_HW_VOLTAGE / Voltage
SEN_HW_VOLTAGE / Status
SEN_HW_TEMPERATURE / Status
SEN_HW_TEMPERATURE / Temperature
SEN_HW_POWERSUPPLY / Status
SEN_HW_OTHERDEVICE / Status
SEN_HW_MEMORY / Status
SEN_HW_CPU / Status
SEN_HW_ENCLOSURE / Status
SEN_HW_ENCLOSURE / IntrusionStatus
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
149
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Dell OpenManage Storage Manager
This connector provides DELL disk array monitoring through the Dell Storage Manager Agent which supports almost all DELL disk arrays.
Target
Typical platform: Dell PowerEdge
Operating systems: Microsoft Windows, Linux
Instrumentation layer: Dell OpenManage Server Administrator
Technology used: SNMP
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Parameters collected
SEN_HW_DISKCONTROLLER / ControllerStatus
SEN_HW_DISKCONTROLLER / BatteryStatus
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
Fibre Alliance SNMP Agent (Switches)
This connector discovers the enclosure and fiber-channel ports of SAN switches as well as the various environment sensors (temperatures, fans, power supplies, etc.). It relies on the SNMP protocol and supports the Fibre Alliance MIB (FCMGMT-MIB).
Target
Typical platform(s): SAN Switches
Operating system(s): Storage Device
Instrumentation layer: Fibre Alliance SNMP Agent (FCMGMT-MIB)
150
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Technology used: SNMP
Discovered objects
Fans (SEN_HW_FAN)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Network cards (SEN_HW_NETWORK)
Enclosure model (SEN_HW_ENCLOSURE)
Collected parameters
SEN_HW_FAN / Status
SEN_HW_TEMPERATURE / Status
SEN_HW_POWERSUPPLY / Status
SEN_HW_NETWORK / Status
SEN_HW_NETWORK / LinkStatus
SEN_HW_NETWORK / LinkSpeed
SEN_HW_NETWORK / ErrorCount
SEN_HW_NETWORK / TransmittedPacketsRate
SEN_HW_NETWORK / ReceivedPacketsRate
SEN_HW_NETWORK / TransmittedBytesRate
SEN_HW_NETWORK / ReceivedBytesRate
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
Fujitsu-Siemens Management Blade (FSC BX
Blade Servers)
This connector provides hardware monitoring through the Fujitsu-Siemens Management Blade SNMP
Agent which supports the Fujitsu-Siemens Blade servers (BX300, BX600, etc.). Needs to run remotely.
Target
Typical platform: Fujitsu-Siemens BX Blade Servers
Operating systems: N/A
Instrumentation layer: Fujitsu-Siemens Management Blade
Technology used: SNMP
151
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Fans (SEN_HW_FAN)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Blades (SEN_HW_BLADE)
Enclosure model (SEN_HW_ENCLOSURE)
Parameters collected
SEN_HW_FAN / Status
SEN_HW_FAN / Speed
SEN_HW_TEMPERATURE / Temperature
SEN_HW_POWERSUPPLY / Status
SEN_HW_BLADE / Status
This conne ctor ta rge ts re mote de v ice s only .
Fujitsu-Siemens ServerView RAID Agent
Fujitsu-Siemens ServerView RAID Agent
This connector provides disk monitoring through the Fujitsu-Siemens ServerView RAID SNMP sub-agent which supports many RAID controllers in Primergy servers.
Target
Typical platform: Fujitsu-Siemens PRIMERGY
Operating systems: Microsoft Windows, Linux
Instrumentation layer: Fujitsu-Siemens ServerView RAID Agent
Technology used: SNMP
Connectors
152
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Parameters collected
SEN_HW_DISKCONTROLLER / BatteryStatus
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
SEN_HW_PHYSICALDISK / ErrorCount
SEN_HW_PHYSICALDISK / PredictedFailure
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
Fujitsu-Siemens Serverview
This connector provides hardware monitoring through the Fujitsu-Siemens Serverview Agent which supports almost all Fujitsu-Siemens PRIMERGY servers.
Target
Typical platform: Fujitsu-Siemens PRIMERGY
Operating systems: Microsoft Windows, Linux
Instrumentation layer: Fujitsu-Siemens Serveview Agent
Technology used: SNMP
Connectors
153
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Fans (SEN_HW_FAN)
Voltage sensors (SEN_HW_VOLTAGE)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Memory modules (SEN_HW_MEMORY)
Processors (SEN_HW_CPU)
Enclosure model (SEN_HW_ENCLOSURE)
Parameters collected
SEN_HW_FAN / Status
SEN_HW_FAN / Speed
SEN_HW_VOLTAGE / Voltage
SEN_HW_TEMPERATURE / Temperature
SEN_HW_POWERSUPPLY / Status
SEN_HW_MEMORY / Status
SEN_HW_MEMORY / ErrorCount
SEN_HW_CPU / Status
SEN_HW_ENCLOSURE / IntrusionStatus
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
HP BladeSystem
This connector provides hardware monitoring for the HP BladeSystem racks through the HP Insight
Management Agents.
Target
Typical platform: HP BladeSystem
Operating systems: Microsoft Windows, Linux
Instrumentation layer: HP iLO / HP Insight Management Agents
Technology used: SNMP
Connectors
154
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Fans (SEN_HW_FAN)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Other devices (SEN_HW_OTHERDEVICE)
Enclosure model (SEN_HW_ENCLOSURE)
Parameters collected
SEN_HW_FAN / Status
SEN_HW_TEMPERATURE / Temperature
SEN_HW_TEMPERATURE / Status
SEN_HW_POWERSUPPLY / Status
SEN_HW_OTHERDEVICE / Status
SEN_HW_ENCLOSURE / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
HP BladeSystem - Telnet/SSH
This connector provides hardware monitoring for the HP BladeSystem racks through the Onboard
Administrator.
Target
Typical platform(s): HP BladeSystem
Operating system(s): N/A
Instrumentation layer: HP BladeSystem Onboard Administrator
Technology used: Telnet/SSH
Discovered objects
Fans (SEN_HW_FAN)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Blades (SEN_HW_BLADE)
Other devices (SEN_HW_OTHERDEVICE)
Enclosure model (SEN_HW_ENCLOSURE)
155
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Collected parameters
SEN_HW_FAN / Status
SEN_HW_FAN / SpeedPercent
SEN_HW_TEMPERATURE / Status
SEN_HW_TEMPERATURE / Temperature
SEN_HW_POWERSUPPLY / Status
SEN_HW_POWERSUPPLY / UsedWatts
SEN_HW_BLADE / Status
SEN_HW_OTHERDEVICE / Status
SEN_HW_ENCLOSURE / Status
SEN_HW_ENCLOSURE / powerconsumption
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
HP Insight Management Agent–Drive Array
This connector monitors the HP/Compaq Drive Arrays by connecting to the Storage Management SNMP sub-agent of the HP Insight Manager agent.
Target
Typical platform: HP ProLiant
Operating system(s): Microsoft Windows, Linux, HP OpenVMS, HP Tru64, Sun Solaris
Instrumentation layer: HP Insight Management Agents
Technology used: SNMP
Connectors
156
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Batteries (SEN_HW_BATTERY)
Parameters collected
SEN_HW_DISKCONTROLLER / ControllerStatus
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
SEN_HW_PHYSICALDISK / PredictedFailure
SEN_HW_BATTERY / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
HP Insight Management Agent–Fiber Array
This connector monitors the fiber-connected HP/Compaq StorageWorks Arrays by connecting to the
Fiber Array Management SNMP sub-agent of the HP Insight Manager agent.
Target
Typical platform: HP ProLiant
Operating systems: Microsoft Windows, Linux, HP Tru64, HP OpenVMS, Sun Solaris
Instrumentation layer: HP Insight Management Agents
Technology used: SNMP
Connectors
157
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Other devices (SEN_HW_OTHERDEVICE)
Enclosure model (SEN_HW_ENCLOSURE)
Parameters collected
SEN_HW_DISKCONTROLLER / ControllerStatus
SEN_HW_DISKCONTROLLER / BatteryStatus
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
SEN_HW_PHYSICALDISK / PredictedFailure
SEN_HW_PHYSICALDISK / ErrorCount
SEN_HW_OTHERDEVICE / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
HP Insight Management Agent - HBA
This connector monitors the HBA cards present in an HP ProLiant system by connecting to the HP Insight
Management agent.
Target
Typical platform(s): HP ProLiant
Operating system(s): Microsoft Windows, Linux, HP Tru64, HP OpenVMS, Sun Solaris
Instrumentation layer: HP Insight Management Agents
Technology used: SNMP
Discovered objects
Network cards (SEN_HW_NETWORK)
Collected parameters
SEN_HW_NETWORK / Status
SEN_HW_NETWORK / LinkStatus
158
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
HP Insight Managerment Agent - IDE Storage
This connector monitors the HP/Compaq IDE Drive Arrays by connecting to the Storage Management
SNMP sub-agent of the HP Insight Manager agent.
Target
Typical platform: HP ProLiant
Operating systems: Microsoft Windows, Linux, HP Tru64, HP OpenVMS, Sun Solaris
Instrumentation layer: HP Insight Management Agents
Technology used: SNMP
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Parameters collected
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
SEN_HW_PHYSICALDISK / PredictedFailure
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
HP Insight Management Agent–iLO
This connector provides hardware monitoring OF the HP iLO card in HP ProLiant servers through the HP
Insight Manager (Server Agent) which supports almost all HP Proliant and Integrity servers under
Windows and Linux, as well as Tru64 servers.
Target
Typical platform: HP ProLiant
Operating systems: Microsoft Windows, Linux, HP OpenVMS, HP Tru64, Sun Solaris
159
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Instrumentation layer: HP Insight Management Agents
Technology used: SNMP
Discovered objects
Other devices (SEN_HW_OTHERDEVICE)
Network cards (SEN_HW_NETWORK)
Parameters collected
SEN_HW_OTHERDEVICE / Status
SEN_HW_NETWORK / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
HP Insight Management Agent–SCSI Storage
This connector monitors the HP/Compaq SCSI disk by connecting to the Storage Management SNMP sub-agent of the HP Insight Manager agent.
Target
Typical platform: HP ProLiant
Operating systems: Microsoft Windows, Linux, HP Tru64, HP OpenVMS, Sun Solaris
Instrumentation layer: HP Insight Management Agents
Technology used: SNMP
Connectors
160
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Parameters collected
SEN_HW_DISKCONTROLLER / ControllerStatus
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
SEN_HW_PHYSICALDISK / PredictedFailure
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
HP Insight Management Agent–Server
This connector provides hardware monitoring through the HP Insight Manager (Server Agent) which supports almost all HP Proliant and Integrity servers under Windows and Linux, as well as Tru64 servers.
Target
Typical platform: HP ProLiant
Operating systems: Microsoft Windows, Linux, HP Tru64, HP OpenVMS, Sun Solaris
Instrumentation layer: HP Insight Management Agents
Technology used: SNMP
Connectors
161
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Fans (SEN_HW_FAN)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Memory modules (SEN_HW_MEMORY)
Processors (SEN_HW_CPU)
Enclosure model (SEN_HW_ENCLOSURE)
Parameters collected
SEN_HW_FAN / Status
SEN_HW_TEMPERATURE / Temperature
SEN_HW_POWERSUPPLY / Status
SEN_HW_POWERSUPPLY / UsedWatts
SEN_HW_MEMORY / Status
SEN_HW_CPU / Status
SEN_HW_CPU / PredictedFailure
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
HP Insight Management Agent–Server (Alpha)
This connector adds HP Tru64-specific hardware monitoring through the HP Insight Manager (Server
Agent).
Target
Typical platform: HP ProLiant
Operating systems: HP Tru64, HP OpenVMS
Instrumentation layer: HP Insight Management Agents
Technology used: SNMP
Connectors
162
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Fans (SEN_HW_FAN)
Power supplies (SEN_HW_POWERSUPPLY)
Parameters collected
SEN_HW_FAN / Status
SEN_HW_POWERSUPPLY / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
HP Insight Management Agent - Server - WMI
This connector provides hardware monitoring through the HP Insight Manager (Server Agent) which supports almost all HP Proliant and Integrity servers under Windows and Linux, as well as Tru64 servers.
Target
Typical platform(s): HP ProLiant
Operating system(s): Microsoft Windows
Instrumentation layer: HP Insight Management Agents - WMI
Technology used: WMI
Connectors
163
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Fans (SEN_HW_FAN)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Other devices (SEN_HW_OTHERDEVICE)
Memory modules (SEN_HW_MEMORY)
Processors (SEN_HW_CPU)
Network cards (SEN_HW_NETWORK)
Enclosure model (SEN_HW_ENCLOSURE)
Collected parameters
SEN_HW_FAN / Status
SEN_HW_TEMPERATURE / Temperature
SEN_HW_TEMPERATURE / Status
SEN_HW_POWERSUPPLY / Status
SEN_HW_OTHERDEVICE / Status
SEN_HW_MEMORY / Status
SEN_HW_CPU / CurrentSpeed
SEN_HW_CPU / Status
SEN_HW_NETWORK / Status
SEN_HW_NETWORK / LinkStatus
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
HP MP/GSP card (iLO)
This connector provides environmental information (temperatures, fans, etc.) on HP 9000 and Integrity servers through HP Integrated Lights-Out Management Card
Target
Typical platforms: HP 9000, Integrity, SuperDome
Operating system: N/A
Instrumentation layer: HP MP/GSP card (iLO)
Technology used: Telnet/SSH
164
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Fans (SEN_HW_FAN)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Enclosure model (SEN_HW_ENCLOSURE)
Parameters collected
SEN_HW_FAN / Status
SEN_HW_TEMPERATURE / Status
SEN_HW_POWERSUPPLY / Status
SEN_HW_ENCLOSURE / Status
This conne ctor ta rge ts re mote de v ice s only .
HP TopTools Agent
This connector provides hardware monitoring through the HP TopTools Agent version 5.x which supports almost all HP NetServer servers under Windows.
Target
Typical platform: HP NetServer
Operating system: Microsoft Windows
Instrumentation layer: HP TopTools Agent
Technology used: System commands, WMI
Connectors
165
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Fans (SEN_HW_FAN)
Voltage sensors (SEN_HW_VOLTAGE)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Memory modules (SEN_HW_MEMORY)
Processors (SEN_HW_CPU)
Enclosure model (SEN_HW_ENCLOSURE)
Parameters collected
SEN_HW_FAN / Speed
SEN_HW_FAN / Status
SEN_HW_VOLTAGE / Voltage
SEN_HW_VOLTAGE / Status
SEN_HW_TEMPERATURE / Temperature
SEN_HW_POWERSUPPLY / Status
SEN_HW_MEMORY / Status
SEN_HW_CPU / Status
This conne ctor is a v a ila ble for use to monitor the loca l host only .
HP TopTools NetRaid Agent
This connector monitors the RAID disks (physical and logical) attached to a HP NetRAID controller. It uses the information provided by the HP NetRAID SNMP Sub-Agent, installed with the HP TopTools
Server Agent.
Target
Typical platform: HP NetServer
Operating systems: Linux, Microsoft Windows
Instrumentation layer: HP TopTools NetRaid Agent
Technology used: SNMP
Connectors
166
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Parameters collected
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
HP-UX–Common
This connector provides hardware status information (processors, network interfaces) on HP-UX systems. Requires root privileges for disk monitoring.
Target
Typical platforms: HP 9000, HP Integrity, HP SuperDome
Operating system: HP-UX
Instrumentation layer: HP-UX system commands (ioscan, lanscan, etc.)
Technology used: System commands
Discovered objects
Processors (SEN_HW_CPU)
Network cards (SEN_HW_NETWORK)
Enclosure model (SEN_HW_ENCLOSURE)
Parameters collected
SEN_HW_CPU / Status
SEN_HW_NETWORK / Status
SEN_HW_NETWORK / LinkStatus
SEN_HW_NETWORK / ErrorCount
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
Credentials required
167
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
This connector probably requires root privileges for its proper operation. You therefore will need to configure the product to use the root login/password to execute external commands. Alternatively, you can configure the product to use the sudo utility for the following command: /usr/bin/adb.
HP-UX–Disks
This connector provides hardware SCSI disks status information on HP-UX systems. Requires root privileges.
Target
Typical platforms: HP 9000, HP Integrity, HP SuperDome
Operating system: HP-UX
Instrumentation layer: HP-UX system commands (pvdisplay, ioscan, etc.)
Technology used: System commands
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Physical disks (SEN_HW_PHYSICALDISK)
Parameters collected
SEN_HW_PHYSICALDISK / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
Credentials required
This connector probably requires root privileges for its proper operation. You therefore will need to configure the product to use the root login/password to execute external commands.
Alternatively, you can configure the product to use the sudo utility for the following command: /usr/sbin/ diskinfo
Connectors
168
BMC Performance Manager Express for Hardware
Version 2.7.17
HP-UX - Network
Discovers and monitors Ethernet adapters.
Target
Typical platform(s): HP 9000, HP Integrity, HP SuperDome
Operating system(s): HP-UX
Instrumentation layer: HP-UX system commands (lanscan, etc.)
Technology used: System commands
Discovered objects
Network cards (SEN_HW_NETWORK)
Collected parameters
SEN_HW_NETWORK / Status
SEN_HW_NETWORK / LinkStatus
SEN_HW_NETWORK / ErrorCount
SEN_HW_NETWORK / TransmittedPacketsRate
SEN_HW_NETWORK / ReceivedPacketsRate
SEN_HW_NETWORK / TransmittedBytesRate
SEN_HW_NETWORK / ReceivedBytesRate
SEN_HW_NETWORK / LinkSpeed
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
HP-UX - SASMGR Managed Disks
Provides hardware SAS Raid disks status information on HP-UX systems. Requires root privileges.
Target
Typical platform(s): HP 9000, HP Integrity, HP SuperDome
Operating system(s): HP-UX
Instrumentation layer: HP-UX system commands (sasmgr, ioscan etc.)
169
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Technology used: System commands
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Collected parameters
SEN_HW_DISKCONTROLLER / ControllerStatus
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
This connector probably requires root privileges for its proper operation. You therefore will need to configure the product to use the root login/password to execute external commands. Alternatively, you can configure the product to use the 'sudo' utility for the following commands: * /opt/sas/bin/sasmgr
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
HP-UX-STM
This connector enables monitoring physical disks and memory modules on HP-UX systems through the
Support Tools Manager utilities (STM).
Target
Typical platforms: HP 9000, HP Integrity, HP SuperDome
Operating system: HP-UX
Instrumentation layer: HP-UX Support Tools Manager (STM)
Technology used: System commands
Connectors
170
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Physical disks (SEN_HW_PHYSICALDISK)
Memory modules (SEN_HW_MEMORY)
Parameters collected
SEN_HW_PHYSICALDISK / Status
SEN_HW_PHYSICALDISK / ErrorCount
SEN_HW_MEMORY / Status
SEN_HW_MEMORY / ErrorCount
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
IBM BladeCenter Management Module
This connector provides hardware monitoring of the IBM BladeCenter chassis through the IBM
BladeCenter Management Module (SNMP-based). Needs to run remotely.
Target
Typical platform: IBM BladeCenter
Operating system: Not applicable
Instrumentation layer: IBM BladeCenter Management Module
Technology used: SNMP
Connectors
171
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Fans (SEN_HW_FAN)
Voltage sensors (SEN_HW_VOLTAGE) -
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Blades (SEN_HW_BLADE)
Enclosure model (SEN_HW_ENCLOSURE)
Parameters collected
SEN_HW_FAN / SpeedPercent
SEN_HW_VOLTAGE / Voltage
SEN_HW_TEMPERATURE / Temperature
SEN_HW_POWERSUPPLY / Status
SEN_HW_BLADE / Status
This conne ctor ta rge ts re mote de v ice s only .
IBM AIX–CHRP Environment
This connector provides hardware environment information (temperatures, voltages, fans, power supplies) on IBM CHRP-based AIX systems.
Target
Typical platforms: IBM RS/6000, IBM pSeries, IBM eServer p5
Operating system: IBM AIX
Instrumentation layer: IBM AIX system commands (machstat)
Technology used: System commands
Discovered objects
Fans (SEN_HW_FAN)
Power supplies (SEN_HW_POWERSUPPLY)
Parameters collected
SEN_HW_FAN / Status
SEN_HW_POWERSUPPLY / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
172
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Credentials required
This connector probably requires root privileges for its proper operation. You therefore will need to configure the product to use the root login/password to execute external commands.
Alternatively, you can configure the product to use the sudo utility for the following commands:
/usr/sbin/bootinfo
/usr/sbin/machstat
IBM AIX–Common
This connector provides hardware status information (processors, network interfaces) on IBM AIX systems
Target
Typical platforms: IBM RS/6000, IBM pSeries, IBM eServer p5
Operating system: IBM AIX
Instrumentation layer: IBM AIX system commands (lsdev, entstat, etc.)
Technology used: System commands
Discovered objects
Processors (SEN_HW_CPU)
Network cards (SEN_HW_NETWORK)
Enclosure model (SEN_HW_ENCLOSURE)
Parameters collected
SEN_HW_CPU / Status
SEN_HW_NETWORK / Status
SEN_HW_NETWORK / LinkStatus
SEN_HW_NETWORK / ErrorCount
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
Connectors
173
BMC Performance Manager Express for Hardware
Version 2.7.17
IBM AIX–Environment
This connector provides hardware environment information: temperatures, voltages, fans, power supplies on IBM AIX systems
Target
Typical platforms: IBM RS/6000, IBM pSeries, IBM eServer p5
Operating system: IBM AIX
Instrumentation layer: IBM AIX system commands (uesensor)
Technology used: System commands
Discovered objects
Fans (SEN_HW_FAN)
Voltage sensors (SEN_HW_VOLTAGE)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Parameters collected
SEN_HW_FAN / Speed
SEN_HW_VOLTAGE / Status
SEN_HW_VOLTAGE / Voltage
SEN_HW_TEMPERATURE / Temperature
SEN_HW_POWERSUPPLY / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
IBM AIX - HBA
Provides hardware status information for the fiber channel HBA cards on IBM AIX systems.
Target
Typical platform(s): IBM RS/6000, IBM pSeries, IBM eServer p5
Operating system(s): IBM AIX
Instrumentation layer: IBM AIX system commands (lsdev, lsattr, fcstat, etc.)
174
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Technology used: System commands
Discovered objects
Network cards (SEN_HW_NETWORK)
Collected parameters
SEN_HW_NETWORK / LinkStatus
SEN_HW_NETWORK / ErrorCount
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
IBM AIX–SCSI disks
This connector provides hardware status information of the non-RAID SCSI physical disks on IBM AIX systems
Target
Typical platforms: IBM RS/6000, IBM pSeries, IBM eServer p5
Operating systems: IBM AIX
Instrumentation layer: IBM AIX system commands (lsdev, pvdisplay, etc.)
Technology used: System commands
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Physical disks (SEN_HW_PHYSICALDISK)
Parameters collected
SEN_HW_PHYSICALDISK / Status
SEN_HW_PHYSICALDISK / ErrorCount
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
175
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
IBM Director Agent 3.x–Windows
This connector provides hardware monitoring through the IBM Director Agent version 3.x which supports almost all IBM Netfinity and xSeries servers. This connector is WBEM-based.
Target
Typical platforms: IBM xSeries, IBM Netfinity
Operating system: Microsoft Windows
Instrumentation layer: IBM Director Agent 3.x
Technology used: WMI
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Fans (SEN_HW_FAN)
Voltage sensors (SEN_HW_VOLTAGE)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Parameters collected
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
SEN_HW_FAN / Speed
SEN_HW_VOLTAGE / Voltage
SEN_HW_TEMPERATURE / Temperature
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
IBM Director Agent 4.x–Linux
This connector provides hardware monitoring through the IBM Director Agent version 4.x which supports some (not all) xSeries servers.
Target
Typical platforms: IBM xSeries, IBM Netfinity
176
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Operating system: Linux
Instrumentation layer: IBM Director Agent 4.x
Technology used: WBEM
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Fans (SEN_HW_FAN)
Voltage sensors (SEN_HW_VOLTAGE)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Memory modules (SEN_HW_MEMORY)
Processors (SEN_HW_CPU)
Enclosure model (SEN_HW_ENCLOSURE)
Parameters collected
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
SEN_HW_FAN / Speed
SEN_HW_VOLTAGE / Voltage
SEN_HW_TEMPERATURE / Temperature
SEN_HW_POWERSUPPLY / Status
SEN_HW_MEMORY / Status
SEN_HW_CPU / Status
SEN_HW_ENCLOSURE / IntrusionStatus
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
Credentials required
This connector probably requires root privileges for its proper operation. You therefore will need to configure the product to use the root login/password to execute external commands.
Alternatively, you can configure the product to use the sudo utility for the following command: /opt/IBM/ director/CIMOM/bin/cimcli.
Connectors
177
BMC Performance Manager Express for Hardware
Version 2.7.17
IBM Director Agent 4.x–Linux
This connector provides hardware monitoring through the IBM Director Agent version 4.x which supports almost all IBM Netfinity and xSeries servers.
Target
Typical platforms: IBM xSeries, IBM Netfinity
Operating system: Microsoft Windows
Instrumentation layer: IBM Director Agent 4.x
Technology used: WMI
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Fans (SEN_HW_FAN)
Voltage sensors (SEN_HW_VOLTAGE)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Memory modules (SEN_HW_MEMORY)
Processors (SEN_HW_CPU)
Enclosure model (SEN_HW_ENCLOSURE)
Parameters collected
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
SEN_HW_FAN / Speed
SEN_HW_VOLTAGE / Voltage
SEN_HW_TEMPERATURE / Temperature
SEN_HW_POWERSUPPLY / Status
SEN_HW_MEMORY / Status
SEN_HW_CPU / Status
SEN_HW_ENCLOSURE / IntrusionStatus
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
178
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
IBM Director Agent 5.10.x–Linux
This connector provides hardware monitoring through the IBM Director Agent version 5.x which supports some (not all) xSeries servers.
Target
Typical platforms: IBM xSeries, IBM Netfinity
Operating system: Linux
Instrumentation layer: IBM Director Agent 5.10.x
Technology used: WBEM
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Fans (SEN_HW_FAN)
Voltage sensors (SEN_HW_VOLTAGE)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Memory modules (SEN_HW_MEMORY)
Processors (SEN_HW_CPU)
Enclosure model (SEN_HW_ENCLOSURE)
Parameters collected
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
SEN_HW_FAN / Speed
SEN_HW_VOLTAGE / Voltage
SEN_HW_TEMPERATURE / Temperature
SEN_HW_POWERSUPPLY / Status
SEN_HW_MEMORY / Status
SEN_HW_CPU / Status
SEN_HW_ENCLOSURE / IntrusionStatus
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
179
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Credentials required
This connector probably requires root privileges for its proper operation. You therefore will need to configure the product to use the root login/password to execute external commands.
Alternatively, you can configure the product to use the sudo utility for the following command: /opt/ibm/ director/cimom/bin/CLI.
IBM Director Agent 5.10.x–Windows
This connector provides hardware monitoring through the IBM Director Agent version 5.x which supports almost all IBM Netfinity and xSeries servers.
Target
Typical platforms: IBM xSeries, IBM Netfinity
Operating system: Microsoft Windows
Instrumentation layer: IBM Director Agent 5.10.x
Technology used: WMI
Connectors
180
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Fans (SEN_HW_FAN)
Voltage sensors (SEN_HW_VOLTAGE)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Memory modules (SEN_HW_MEMORY)
Processors (SEN_HW_CPU)
Enclosure model (SEN_HW_ENCLOSURE)
Parameters collected
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
SEN_HW_FAN / Speed
SEN_HW_VOLTAGE / Voltage
SEN_HW_TEMPERATURE / Temperature
SEN_HW_POWERSUPPLY / Status
SEN_HW_MEMORY / Status
SEN_HW_CPU / Status
SEN_HW_ENCLOSURE / IntrusionStatus
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
IBM Director Agent 5.20.x–Linux
This connector provides hardware monitoring through the IBM Director Agent version 5.20.x which supports some (not all) xSeries servers.
Target
Typical platforms: IBM xSeries, IBM Netfinity
Operating system: Linux
Instrumentation layer: IBM Director Agent 5.20.x
Technology used: WBEM
181
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Fans (SEN_HW_FAN)
Voltage sensors (SEN_HW_VOLTAGE)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Memory modules (SEN_HW_MEMORY)
Processors (SEN_HW_CPU)
Enclosure model (SEN_HW_ENCLOSURE)
Parameters collected
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
SEN_HW_FAN / Speed
SEN_HW_VOLTAGE / Voltage
SEN_HW_TEMPERATURE / Temperature
SEN_HW_POWERSUPPLY / Status
SEN_HW_MEMORY / Status
SEN_HW_CPU / Status
SEN_HW_ENCLOSURE / IntrusionStatus
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
Credentials required
This connector probably requires root privileges for its proper operation. You therefore will need to configure the product to use the root login/password to execute external commands. Alternatively, you can configure the product to use the sudo utility for the command: /opt/ibm/icc/cimom/bin/CLI.
IBM Director Agent 5.20.x–ServeRAID - Linux
This connector provides IBM ServeRAID disks monitoring through the IBM ServeRAID Manager Agent component of the IBM Director Agent version 5.20.x which supports almost all IBM Netfinity and xSeries servers.
Target
Typical platforms: IBM xSeries, IBM Netfinity
Operating system: Linux
182
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Instrumentation layer: IBM Director Agent 5.20.x
Technology used: WBEM
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Collected parameters
SEN_HW_DISKCONTROLLER / ControllerStatus
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m
IBM Director Agent 5.20.x–Windows
This connector provides hardware monitoring through the IBM Director Agent version 5.20.x which supports almost all IBM Netfinity and xSeries servers.
Target
Typical platforms: IBM xSeries, IBM Netfinity
Operating system: Microsoft Windows
Instrumentation layer: IBM Director Agent 5.20.x
Technology used: WMI
Connectors
183
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Fans (SEN_HW_FAN)
Voltage sensors (SEN_HW_VOLTAGE)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Memory modules (SEN_HW_MEMORY)
Processors (SEN_HW_CPU)
Enclosure model (SEN_HW_ENCLOSURE)
Parameters collected
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
SEN_HW_FAN / Speed
SEN_HW_VOLTAGE / Voltage
SEN_HW_TEMPERATURE / Temperature
SEN_HW_POWERSUPPLY / Status
SEN_HW_MEMORY / Status
SEN_HW_CPU / Status
SEN_HW_ENCLOSURE / IntrusionStatus
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
IBM Director Agent 5.20.x–ServeRAID -
Windows
This connector provides IBM ServeRAID disks monitoring through the IBM ServeRAID Manager Agent component of the IBM Director Agent version 5.20.x which supports almost all IBM Netfinity and xSeries servers.
Target
Typical platform(s): IBM xSeries, IBM Netfinity
Operating system(s): Microsoft Windows
Instrumentation layer: IBM Director Agent 5.20.x
Technology used: WMI
184
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Collected parameters
SEN_HW_DISKCONTROLLER / ControllerStatus
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
IBM DS (LSI) Disk Arrays (smcli)
This connector provides hardware monitoring for IBM DS Storage Systems through the the SMCli utility.
Target
Typical platform(s): IBM DSxxxx Disk Array
Operating system(s): Storage Device
Instrumentation layer: SMCLI
Technology used: System commands
Connectors
185
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Fans (SEN_HW_FAN)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Other devices (SEN_HW_OTHERDEVICE)
Network cards (SEN_HW_NETWORK)
Enclosure model (SEN_HW_ENCLOSURE)
Batteries (SEN_HW_BATTERY)
Collected parameters
SEN_HW_DISKCONTROLLER / ControllerStatus
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
SEN_HW_FAN / Status
SEN_HW_TEMPERATURE / Status
SEN_HW_POWERSUPPLY / Status
SEN_HW_OTHERDEVICE / Status
SEN_HW_NETWORK / Status
SEN_HW_BATTERY / Status
This conne ctor is a ble to monitor re mote sy ste m only .
IBM Netfinity Manager 5.20.x–Basic
This connector provides basic environment monitoring through the IBM Netfinity Manager Services SNMP sub-agent which supports almost all old IBM servers (Netfinity) under Windows.
Target
Typical platform: IBM Netfinity
Operating system: Microsoft Windows
Instrumentation layer: IBM Netfinity Manager 5.20.x
Technology used: SNMP
186
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Fans (SEN_HW_FAN)
Voltage sensors (SEN_HW_VOLTAGE)
Temperature sensors (SEN_HW_TEMPERATURE)
Parameters collected
SEN_HW_FAN / Status
SEN_HW_VOLTAGE / Status
SEN_HW_TEMPERATURE / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
IBM Netfinity Manager 5.20.x–Disks
This connector provides IBM ServerRAID monitoring through the IBM Netfinity Manager Services SNMP sub-agent which supports almost all old IBM servers (Netfinity) under Windows.
Target
Typical platform: IBM Netfinity
Operating system: Microsoft Windows
Instrumentation layer: IBM Netfinity Manager 5.20.x
Technology used: SNMP
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Parameters collected
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
187
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
IBM Netfinity Manager 5.20.x–Normal
This connector provides environment monitoring through the IBM Netfinity Manager Services SNMP subagent which supports almost all old IBM servers (Netfinity) under Windows.
Target
Typical platform: IBM Netfinity
Operating systems: Microsoft Windows
Instrumentation layer: IBM Netfinity Manager 5.20.x
Technology used: SNMP
Discovered objects
Voltage sensors (SEN_HW_VOLTAGE)
Temperature sensors (SEN_HW_TEMPERATURE)
Enclosure model (SEN_HW_ENCLOSURE)
Parameters collected
SEN_HW_VOLTAGE / Voltage
SEN_HW_TEMPRATURE / Temperature
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
IPMI–In-band (IpmiTool)
This connector provides environmental information (temperatures, fans, etc.) on several IPMI-enabled servers through the ipmitool utility and OpenIPMI driver
Target
Typical platform: Sun Fire (x64)
Operating systems: Linux, Sun Solaris
Instrumentation layer: ipmitool
Technology used: System commands
188
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Fans (SEN_HW_FAN)
Voltage sensors (SEN_HW_VOLTAGE)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Enclosure model (SEN_HW_ENCLOSURE)
Parameters collected
SEN_HW_FAN / Speed
SEN_HW_VOLTAGE / Voltage
SEN_HW_TEMPERATURE / Temperature
SEN_HW_POWERSUPPLY / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
Credentials required
This connector probably requires root privileges for its proper operation. You therefore will need to configure the product to use the root login/password to execute external commands.
Alternatively, you can configure the product to use the sudo utility for the command: ipmitool.
LSI 1030-based GAM Server
This connector provides disk monitoring for LSI c1030-based disk controllers (also known as LSI
Integrated Mirroring) through the LSI1030 SNMP sub-agent.
Target
Typical platforms: Fujitsu-Siemens PRIMERGY
Operating systems: Microsoft Windows, Linux
Instrumentation layer: LSI GAM Server
Technology used: SNMP
Connectors
189
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Parameters collected
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
LSI 1030-based GAM Server (Alternate MIB)
This connector provides disk monitoring for LSI c1030-based disk controllers (also known as LSI
Integrated Mirroring) through the LSI1030 SNMP sub-agent (based on the 1.3.6.1.4.1.3582.2 MIB).
Target
Typical platform: Fujitsu-Siemens PRIMERGY
Operating system: Microsoft Windows, Linux
Instrumentation layer: LSI GAM Server
Technology used: SNMP
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Parameters collected
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
190
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
LSI Logic LsiUtil
This connector provides information about physical disks and volumes of LSI Logic SAS RAID controllers through the lsiutil utility.
Target
Typical platforms: Sun Fire (x64)
Operating systems: Linux, Sun Solaris
Instrumentation layer: lsiutil
Technology used: System commands
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Parameters collected
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
Credentials required
This connector probably requires root privileges for its proper operation. You therefore will need to configure the product to use the root login/password to execute external commands.
Alternatively, you can configure the product to use the sudo utility for the following command: lsiutil.
LSI Logic - LsiUtil - RAID (Windows)
Gives information about physical disks and volumes of LSI Logic SAS RAID controllers through the lsiutil utility.
Target
Typical platform(s): Windows servers equipped with an LSI RAID controller
191
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Operating system(s): Microsoft Windows
Instrumentation layer: lsiutil
Technology used: System commands
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Collected parameters
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
This conne ctor is a v a ila ble for use to monitor the loca l host only .
LSI Logic MegaRAID PowerConsole
This connector provides disk monitoring through the LsiLogic MegaRAID PowerConsole SNMP sub-agent which supports all MegaRAID-based RAID controllers.
Target
Typical platform: Fujitsu-Siemens PRIMERGY
Operating systems: Microsoft Windows, Linux
Instrumentation layer: LSI MegaRAID PowerConsole
Technology used: SNMP
Connectors
192
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Parameters collected
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
LsiLogic MegaRAID SAS
This connector provides disk monitoring through the LsiLogic MegaRAID SAS SNMP sub-agent which supports all LSI MegaRaid SAS RAID controllers.
Target
Typical platform: Fujitsu-Siemens PRIMERGY
Operating systems: Microsoft Windows, Linux
Instrumentation layer: LSI MegaRAID SAS SNMP Agent
Technology used: SNMP
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Parameters collected
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
SEN_HW_PHYSICALDISK / ErrorCount
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
193
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
LsiLogic MegaRAID SAS (Newer Controllers)
This connector provides disk monitoring through the LsiLogic MegaRAID SAS SNMP sub-agent which supports newer LSI MegaRaid SAS RAID controllers.
Target
Typical platform(s): Fujitsu-Siemens PRIMERGY
Operating system(s): Microsoft Windows, Linux
Instrumentation layer: LSI MegaRAID SAS SNMP Agent
Technology used: SNMP
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Collected parameters
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
SEN_HW_PHYSICALDISK / ErrorCount
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
LSI/Mylex GAM Server
This connector provides disk monitoring through the Mylex SNMP sub-agent which supports all Mylex disk controllers.
Target
Operating systems: Microsoft Windows, Linux
Instrumentation layer: Mylex GAM Servers
Technology used: SNMP
194
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Parameters collected
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
Linux–Network
This connector provides the monitoring of network cards on all Linux systems.
Target
Typical platforms: Dell PowerEdge, HP ProLiant, Fujitsu-Siemens PRIMERGY, IBM xSeries, Sun Fire
Operating system: Linux
Instrumentation layer: Linux system commands (ethtool, mii-tool)
Technology used: System commands
Discovered objects
Network cards (SEN_HW_NETWORK)
Parameters collected
SEN_HW_NETWORK / ErrorCount
SEN_HW_NETWORK / LinkStatus
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
Credentials required
This connector probably requires root privileges for its proper operation. You therefore will need to configure the product to use the root login/password to execute external commands.
Alternatively, you can configure the product to use the sudo utility for the commands: ethtool mii-tool
195
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
MIB-2 Standard SNMP Agent - Network
Interfaces
This connector discovers the enclosure and Ethernet ports of an Ethernet switch equipped with a MIB-2 standard SNMP Agent.
Target
Typical platform(s): Any SNMP-instrumented device
Operating system(s): Network, HP-UX, Storage Device, HP OpenVMS, HP Tru64
Instrumentation layer: MIB-2 Standard SNMP Agent
Technology used: SNMP
Discovered objects
Network cards (SEN_HW_NETWORK)
Collected parameters
SEN_HW_NETWORK / Status
SEN_HW_NETWORK / LinkStatus
SEN_HW_NETWORK / LinkSpeed
SEN_HW_NETWORK / ErrorCount
SEN_HW_NETWORK / ReceivedPacketsRate
SEN_HW_NETWORK / TransmittedPacketsRate
SEN_HW_NETWORK / ReceivedBytesRate
SEN_HW_NETWORK / TransmittedBytesRate
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
tool
Connectors
196
BMC Performance Manager Express for Hardware
Version 2.7.17
MIB-2 Standard SNMP Agent - Network
Interfaces - Linux
This connector discovers the enclosure and Ethernet ports of an Ethernet switch equipped with a MIB-2 standard SNMP Agent.
Target
Typical platform(s): Any SNMP-instrumented device
Operating system(s): Linux
Instrumentation layer: MIB-2 Standard SNMP Agent
Technology used: SNMP
Discovered objects
Network cards (SEN_HW_NETWORK)
Collected parameters
SEN_HW_NETWORK / Status
SEN_HW_NETWORK / LinkStatus
SEN_HW_NETWORK / LinkSpeed
SEN_HW_NETWORK / ErrorCount
SEN_HW_NETWORK / ReceivedPacketsRate
SEN_HW_NETWORK / TransmittedPacketsRate
SEN_HW_NETWORK / ReceivedBytesRate
SEN_HW_NETWORK / TransmittedBytesRate
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
Connectors
197
BMC Performance Manager Express for Hardware
Version 2.7.17
MIB-2 Standard SNMP Agent - Network
Interfaces - Windows
This connector discovers the enclosure and Ethernet ports of an Ethernet switch equipped with a MIB-2 standard SNMP Agent.
Target
Typical platform(s): Any SNMP-instrumented device
Operating system(s): Microsoft Windows
Instrumentation layer: MIB-2 Standard SNMP Agent
Technology used: SNMP
Discovered objects
Network cards (SEN_HW_NETWORK)
Collected parameters
SEN_HW_NETWORK / Status
SEN_HW_NETWORK / LinkStatus
SEN_HW_NETWORK / LinkSpeed
SEN_HW_NETWORK / ErrorCount
SEN_HW_NETWORK / ReceivedPacketsRate
SEN_HW_NETWORK / TransmittedPacketsRate
SEN_HW_NETWORK / ReceivedBytesRate
SEN_HW_NETWORK / TransmittedBytesRate
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
MIB-2 Standard SNMP Agent - Network
Interfaces - Solaris
This connector discovers the enclosure and Ethernet ports of an Ethernet switch equipped with a MIB-2 standard SNMP Agent.
Target
Typical platform(s): Any SNMP-instrumented device
198
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Operating system(s): Sun Solaris
Instrumentation layer: MIB-2 Standard SNMP Agent
Technology used: SNMP
Discovered objects
Network cards (SEN_HW_NETWORK)
Collected parameters
SEN_HW_NETWORK / Status
SEN_HW_NETWORK / LinkStatus
SEN_HW_NETWORK / LinkSpeed
SEN_HW_NETWORK / ErrorCount
SEN_HW_NETWORK / ReceivedPacketsRate
SEN_HW_NETWORK / TransmittedPacketsRate
SEN_HW_NETWORK / ReceivedBytesRate
SEN_HW_NETWORK / TransmittedBytesRate
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
Motherboard Monitor
This connector provides hardware monitoring through Motherboard Monitor version 5.x which supports almost all non-branded PCs under Windows.
Target
Typical platform: Unbranded PC
Operating system: Microsoft Windows
Instrumentation layer: Motherboard Monitor
Technology used: System commands
Connectors
199
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Fans (SEN_HW_FAN)
Voltage sensors (SEN_HW_VOLTAGE)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Enclosure model (SEN_HW_ENCLOSURE)
Parameters collected
SEN_HW_FAN / Speed
SEN_HW_VOLTAGE / Voltage
SEN_HW_TEMPERATURE / Temperature
This conne ctor is a v a ila ble for use to monitor the loca l host only .
NetApp Filer - SNMP Agent
This connector discovers the enclosure and the disks of NetApp disk arrays (filer) as well as the various environment sensors (temperatures, fans, power supplies, etc.). It relies on the SNMP protocol.
Target
Typical platform(s): Disk Array
Operating system(s): Storage Device
Instrumentation layer: NetApp SNMP Agent
Technology used: SNMP
Connectors
200
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Fans (SEN_HW_FAN)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Network cards (SEN_HW_NETWORK)
Enclosure model (SEN_HW_ENCLOSURE)
Collected parameters
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
SEN_HW_FAN / Status
SEN_HW_TEMPERATURE / Temperature
SEN_HW_POWERSUPPLY / Status
SEN_HW_NETWORK / Status
SEN_HW_NETWORK / LinkStatus
This conne ctor is a ble to monitor re mote sy ste m only .
NEC ESMPRO Agent
This connector provides hardware monitoring through the NEC ESMPRO Agent which supports almost all
NEC Express5800 and some BULL NovaScale servers running Windows and Linux.
Target
Typical platform: NEC Express5800
Operating systems: Microsoft Windows, Linux
Instrumentation layer: NEC ESMPRO Agent
Technology used: SNMP
Connectors
201
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Fans (SEN_HW_FAN)
Voltage sensors (SEN_HW_VOLTAGE)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Memory modules (SEN_HW_MEMORY)
Processors (SEN_HW_CPU)
Enclosure model (SEN_HW_ENCLOSURE)
Parameters collected
SEN_HW_FAN / Status
SEN_HW_VOLTAGE / Voltage
SEN_HW_TEMPERATURE / Temperature
SEN_HW_POWERSUPPLY / Status
SEN_HW_MEMORY / Status
SEN_HW_CPU / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
Promise FastTrack
This connector provides disk monitoring through the Promise FastTrack SNMP agent.
Target
Typical platform: Fujitsu-Siemens PRIMERGY
Operating systems: Microsoft Windows, Linux
Instrumentation layer: Promise FastTrack SNMP Agent
Technology used: SNMP
Connectors
202
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Parameters collected
SEN_HW_DISKCONTROLLER / BatteryStatus
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
MS_HW_PHYSICALDISK / PredictedFailure
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
Quantum (ADIC) Based Tape Libraries
Target
Typical platform(s): Quantum (ADIC) Tape Library
Operating system(s): Storage Device
Instrumentation layer: Quantum SNMP Agent (ADIC-TAPE-LIBRARY-MIB)
Technology used: SNMP
Connectors
203
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Fans (SEN_HW_FAN)
Power supplies (SEN_HW_POWERSUPPLY)
Enclosure model (SEN_HW_ENCLOSURE)
Tape drive (SEN_HW_TAPEDRIVE)
Robotic (SEN_HW_ROBOTIC)
Collected parameters
SEN_HW_DISKCONTROLLER / ControllerStatus
SEN_HW_FAN / Status
SEN_HW_POWERSUPPLY / Status
SEN_HW_ENCLOSURE / Status
SEN_HW_TAPEDRIVE / Status
SEN_HW_TAPEDRIVE / NeedsCleaning
SEN_HW_TAPEDRIVE / MountCount
SEN_HW_ROBOTIC / Status
This conne ctor is a ble to monitor re mote sy ste m only .
SmartMonTools
This connector provides S.M.A.R.T.-enabled physical disk information through the smartd/smartctl utility under Linux
Target
Typical platforms: Dell PowerEdge, Fujitsu-Siemens PRIMERGY, HP ProLiant, IBM xSeries, Sun Fire
(x64)
Operating system: Linux
Instrumentation layer: SmartMonTools
Technology used: System commands
Connectors
204
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Physical disks (SEN_HW_PHYSICALDISK)
Temperature sensors (SEN_HW_TEMPERATURE)
Parameters collected
SEN_HW_PHYSICALDISK / PredictedFailure
SEN_HW_PHYSICALDISK / Status
SEN_HW_TEMPERATURE / Temperature
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
Credentials required
This connector probably requires root privileges for its proper operation. You therefore will need to configure the product to use the root login/password to execute external commands.
Alternatively, you can configure the product to use the sudo utility for the command:
/usr/sbin/smartctl
/bin/dd.
SMI-S Compliant Disk Arrays
This connector discovers the enclosure and the disks of SAN disk arrays, as well as the storage pools and storage volumes. It will also discovery and monitor the FC ports of the array and the various environment sensors when available (temperatures, fans, power supplies, etc.). It relies on the WBEM technology and supports SMI-S compliant disk arrays only.
Target
Typical platform(s): Disk Array
Operating system(s): Storage Device
Instrumentation layer: SMI-S Agent provided by the array vendor
Technology used: WBEM
Connectors
205
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Fans (SEN_HW_FAN)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Other devices (SEN_HW_OTHERDEVICE)
Network cards (SEN_HW_NETWORK)
Enclosure model (SEN_HW_ENCLOSURE)
Collected parameters
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
SEN_HW_FAN / Status
SEN_HW_TEMPERATURE / Temperature
SEN_HW_TEMPERATURE / Status
SEN_HW_POWERSUPPLY / Status
SEN_HW_OTHERDEVICE / Status
SEN_HW_NETWORK / Status
SEN_HW_NETWORK / LinkStatus
SEN_HW_ENCLOSURE / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
SMI-S Compliant HBAs
This connector discovers the HBAs of a server. It relies on the WBEM technology and supports SMI-S compliant HBAs only.
Target
Typical platform(s): Server with HBAs
Operating system(s): Microsoft Windows, Linux, IBM AIX, HP-UX, Tru64, HP OpenVMS, Sun Solaris
Instrumentation layer: SMI-S Agent provided by the HBA vendor
Technology used: WBEM
206
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Network cards (SEN_HW_NETWORK)
Collected parameters
SEN_HW_LOGICALDISK / Status
SEN_HW_NETWORK / Status
SEN_HW_NETWORK / LinkStatus
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
SMI-S Compliant Storage Libraries
This connector discovers the enclosure of a storage library as well as its specialized devices: tape drives, cartridges, media changers, etc.. It will also discovery and monitor the FC ports of the array and the various environment sensors when available (temperatures, fans, power supplies, etc.). It relies on the WBEM technology and supports SMI-S compliant tape libraries only.
Target
Typical platform(s): Storage Libraries
Operating system(s): Storage Device
Instrumentation layer: SMI-S Agent provided by the library vendor
Technology used: WBEM
Connectors
207
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Fans (SEN_HW_FAN)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Other devices (SEN_HW_OTHERDEVICE)
Network cards (SEN_HW_NETWORK)
Enclosure model (SEN_HW_ENCLOSURE)
Tape drives (SEN_HW_TAPEDRIVE)
Robotics (SEN_HW_ROBOTIC)
Collected parameters
SEN_HW_FAN / Status
SEN_HW_TEMPERATURE / Temperature
SEN_HW_TEMPERATURE / Status
SEN_HW_POWERSUPPLY / Status
SEN_HW_OTHERDEVICE / Status
SEN_HW_NETWORK / Status
SEN_HW_NETWORK / LinkStatus
SEN_HW_ENCLOSURE / Status
SEN_HW_TAPEDRIVE / Status
SEN_HW_TAPEDRIVE / MountCount
SEN_HW_TAPEDRIVE / NeedsCleaning
SEN_HW_ROBOTIC / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
SMI-S Compliant SAN Switches
This connector discovers the enclosure and fiber-channel ports of SAN switches as well as the various environment sensors (temperatures, fans, power supplies, etc.). It relies on the WBEM technology and supports SMI-S compliant switches only.
Target
Typical platform(s): SAN Switches
Operating system(s): Storage Device
Instrumentation layer: SMI-S Agent provided by the switch vendor
Technology used: WBEM
208
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Fans (SEN_HW_FAN)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Other devices (SEN_HW_OTHERDEVICE)
Network cards (SEN_HW_NETWORK)
Enclosure model (SEN_HW_ENCLOSURE)
Collected parameters
SEN_HW_FAN / Status
SEN_HW_TEMPERATURE / Temperature
SEN_HW_TEMPERATURE / Status
SEN_HW_POWERSUPPLY / Status
SEN_HW_OTHERDEVICE / Status
SEN_HW_NETWORK / Status
SEN_HW_NETWORK / LinkStatus
SEN_HW_ENCLOSURE / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
SNIA Compliant Tape Libraries
Target
Typical platform(s): IBM Tape Library 3584 / Various TS3xxx libraries from IBM based on the SNIA mib
Operating system(s): Storage Device
Instrumentation layer: SNIA Compliant SNMP Agent (SNIA-SML-MIB)
Technology used: SNMP
Connectors
209
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Enclosure model (SEN_HW_ENCLOSURE)
Tape drive (SEN_HW_TAPEDRIVE)
Robotic (SEN_HW_ROBOTIC)
Collected parameters
SEN_HW_ENCLOSURE / Status
SEN_HW_TAPEDRIVE / Status
SEN_HW_TAPEDRIVE / NeedsCleaning
SEN_HW_ROBOTIC / Status
This conne ctor ta rge ts re mote de v ice s only .
StorageTek LSeries Tape Library
This connector provides basic hardware monitoring of the StorageTek LSeries tape libraries through their built-in SNMP agent. Needs to run remotely.
Target
Typical platform(s): StorageTek LSeries
Operating system(s): Storage Device
Instrumentation layer: StorageTek LSeries SNMP Agent
Technology used: SNMP
Connectors
210
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Fans (SEN_HW_FAN)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Other devices (SEN_HW_OTHERDEVICE)
Enclosure model (SEN_HW_ENCLOSURE)
Tape drive (SEN_HW_TAPEDRIVE)
Robotic (SEN_HW_ROBOTIC)
Collected parameters
SEN_HW_FAN / Status
SEN_HW_TEMPERATURE / Temperature
SEN_HW_POWERSUPPLY / Status
SEN_HW_OTHERDEVICE / Status
SEN_HW_OTHERDEVICE / usagecount
SEN_HW_ENCLOSURE / Status
SEN_HW_TAPEDRIVE / Status
SEN_HW_TAPEDRIVE / MountCount
SEN_HW_ROBOTIC / Status
SEN_HW_ROBOTIC / MoveCount
SEN_HW_ROBOTIC / ErrorCount
This conne ctor is a ble to monitor re mote sy ste m only .
StorageTek StreamLine Tape Library
This connector provides basic hardware monitoring of the StorageTek StreamLine tape libraries through their built-in SNMP agent. Needs to run remotely.
Target
Typical platform(s): StorageTek StreamLine
Operating system(s): Storage Device
Instrumentation layer: StorageTek StreamLine SNMP Agent
Technology used: SNMP
211
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Enclosure model (SEN_HW_ENCLOSURE)
Tape drive (SEN_HW_TAPEDRIVE)
Collected parameters
SEN_HW_ENCLOSURE / Status
SEN_HW_TAPEDRIVE / Status
SEN_HW_TAPEDRIVE / MountCount
This conne ctor is a ble to monitor re mote sy ste m only .
Sun Advanced Lights–Out Management (ALOM) card
This connector provides environmental and disk information (temperatures, fans, etc.) on Sun SPARC servers equipped with an ALOM card. Telnet must be enabled on the ALOM card.
Target
Typical platform: Sun Fire (SPARC)
Operating system: N/A
Instrumentation layer: Sun Advanced Lights-Out Management (ALOM) card
Technology used: Telnet/SSH
Connectors
212
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Physical disks (SEN_HW_PHYSICALDISK)
Fans (SEN_HW_FAN)
Voltage sensors (SEN_HW_VOLTAGE)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Other devices (SEN_HW_OTHERDEVICE)
Enclosure model (SEN_HW_ENCLOSURE)
Parameters collected
SEN_HW_PHYSICALDISK / Status
SEN_HW_FAN / Status
SEN_HW_FAN / Speed
SEN_HW_VOLTAGE / Status
SEN_HW_VOLTAGE / Voltage
SEN_HW_TEMPERATURE / Status
SEN_HW_TEMPERATURE / Temperature
SEN_HW_POWERSUPPLY / Status
SEN_HW_OTHERDEVICE / Status
This conne ctor ta rge ts re mote de v ice s only .
SUN Blade Chassis
This connector provides hardware monitoring for the SUN Blade Chassis through the CMM SNMP Agent /
SSH (optional).
Target
Typical platform(s): SUN Blade Chassis
Operating system(s): N/A
Instrumentation layer: SUN Blade Chassis CMM SNMP Agent
Technology used: SNMP
Connectors
213
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Fans (SEN_HW_FAN)
Voltage sensors (SEN_HW_VOLTAGE)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Enclosure model (SEN_HW_ENCLOSURE)
Collected parameters
SEN_HW_FAN / Speed
SEN_HW_FAN / Status
SEN_HW_VOLTAGE / Status
SEN_HW_VOLTAGE / Voltage
SEN_HW_TEMPERATURE / Temperature
SEN_HW_POWERSUPPLY / Speed
SEN_HW_POWERSUPPLY / Status
This conne ctor is a ble to monitor re mote sy ste m only .
Sun Fire F12K/F15K/F20K/F25K (SMS)
This connector provides environmental information (temperatures, fans, etc.) and boards status on Sun
Fire F12K, F15K, F20K and F25K servers.
Target
Typical platform: Sun Fire (SPARC)
Operating system: Sun Solaris
Instrumentation layer: Sun SMS utilities installed on the System Controller (SC on F15K, etc.)
Technology used: System commands
Connectors
214
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Fans (SEN_HW_FAN)
Voltage sensors (SEN_HW_VOLTAGE)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Other devices (SEN_HW_OTHERDEVICE)
Enclosure model (SEN_HW_ENCLOSURE)
Parameters collected
SEN_HW_FAN / Status
SEN_HW_VOLTAGE / Status
SEN_HW_VOLTAGE / Voltage
SEN_HW_TEMPERATURE / Status
SEN_HW_TEMPERATURE / Temperature
SEN_HW_POWERSUPPLY / Status
SEN_HW_OTHERDEVICE / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
Sun Fire Mx000 (XSCF)
This connector provides environmental information (temperatures, fans, etc.) and boards status on Sun
Fire M4000, M5000, M8000 and M9000 servers.
Target
Typical platform: Sun Fire (SPARC)
Operating system: Sun Solaris
Instrumentation layer: Sun XSCF utilities installed on the System Controller
Technology used: System commands
Connectors
215
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Fans (SEN_HW_FAN)
Voltage sensors (SEN_HW_VOLTAGE)
Power supplies (SEN_HW_POWERSUPPLY)
Other devices (SEN_HW_OTHERDEVICE)
Memory modules (SEN_HW_MEMORY)
Processors (SEN_HW_CPU)
Enclosure model (SEN_HW_ENCLOSURE)
Collected parameters
SEN_HW_FAN / Status
SEN_HW_VOLTAGE / Voltage
SEN_HW_POWERSUPPLY / Status
SEN_HW_OTHERDEVICE / Status
SEN_HW_MEMORY / Status
SEN_HW_CPU / Status
This conne ctor ta rge ts re mote de v ice s only .
SUN ILOM (SNMP)
This connector provides hardware monitoring for the SUN Blades with ILOM cards via SNMP.
Target
Typical platform(s): SUN Blade with ILOM cards
Operating system(s): N/A
Instrumentation layer: SUN Blade SP SNMP Agent
Technology used: SNMP
Connectors
216
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Physical disks (SEN_HW_PHYSICALDISK)
Voltage sensors (SEN_HW_VOLTAGE)
Temperature sensors (SEN_HW_TEMPERATURE)
Memory modules (SEN_HW_MEMORY)
Processors (SEN_HW_CPU)
Enclosure model (SEN_HW_ENCLOSURE)
Collected parameters
SEN_HW_PHYSICALDISK / Status
SEN_HW_PHYSICALDISK / PredictedFailure
SEN_HW_VOLTAGE / Status
SEN_HW_VOLTAGE / Voltage
SEN_HW_TEMPERATURE / Temperature
SEN_HW_MEMORY / Status
SEN_HW_CPU / Status
This conne ctor is a ble to monitor re mote sy ste m only .
SUN ILOM (SSH)
This connector provides hardware monitoring for the SUN Blades with ILOM cards via SSHP.
Target
Typical platform(s): SUN Blade with ILOM cards
Operating system(s): N/A
Instrumentation layer: SUN Blade SP
Technology used: Telnet/SSH
Connectors
217
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Physical disks (SEN_HW_PHYSICALDISK)
Voltage sensors (SEN_HW_VOLTAGE)
Temperature sensors (SEN_HW_TEMPERATURE)
Memory modules (SEN_HW_MEMORY)
Processors (SEN_HW_CPU)
Enclosure model (SEN_HW_ENCLOSURE)
Collected parameters
SEN_HW_PHYSICALDISK / Status
SEN_HW_PHYSICALDISK / PredictedFailure
SEN_HW_VOLTAGE / Voltage
SEN_HW_TEMPERATURE / Temperature
SEN_HW_MEMORY / Status
SEN_HW_CPU / Status
SEN_HW_ENCLOSURE / Status
This conne ctor is a ble to monitor re mote sy ste m only .
Sun Solaris–Environment (ALOM-CMT snapshot)
This connector provides environmental and disk information (temperatures, fans, etc.) on Sun SPARC
T1/T2 servers equipped with an ALOM card. Gathers the hardware information from the ALOM card inband (no telnet or SSH connection over the network). Requires the SUNWexplo (Sun Explorer) package.
Target
Typical platform: Sun Fire (SPARC T1/T2)
Operating system: Sun Solaris
Instrumentation layer: Sun Explorer and the ALOM-CMT card
Technology used: System commands
Connectors
218
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Physical disks (SEN_HW_PHYSICALDISK)
Fans (SEN_HW_FAN)
Voltage sensors (SEN_HW_VOLTAGE)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Other devices (SEN_HW_OTHERDEVICE)
Enclosure model (SEN_HW_ENCLOSURE)
Collected parameters
SEN_HW_PHYSICALDISK / Status
SEN_HW_FAN / Status
SEN_HW_FAN / Speed
SEN_HW_VOLTAGE / Status
SEN_HW_VOLTAGE / Voltage
SEN_HW_TEMPERATURE / Status
SEN_HW_TEMPERATURE / Temperature
SEN_HW_POWERSUPPLY / Status
SEN_HW_OTHERDEVICE / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
This connector probably requires root privileges for its proper operation. You therefore will need to configure the product to use the root login/password to execute external commands.
Alternatively, you can configure the product to use the 'sudo' utility for the following commands: /opt/
SUNWexplo/bin/snapshot.
Sun Solaris–Environment (prtpicl)
This connector provides environmental information (temperatures, fans, etc.) on several Sun platforms through the prtpicl utility. This connector is to be used mainly on Solaris 10 systems.
Target
Typical platform: Sun Fire (SPARC)
Operating system: Sun Solaris
Instrumentation layer: Sun Solaris system commands (prtpicl, etc.)
Technology used: System commands
219
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Fans (SEN_HW_FAN)
Voltage sensors (SEN_HW_VOLTAGE)
Temperature sensors (SEN_HW_TEMPERATURE)
Collected parameters
SEN_HW_FAN / Speed
SEN_HW_FAN / SpeedPercent
SEN_HW_FAN / Status
SEN_HW_VOLTAGE / Voltage
SEN_HW_VOLTAGE / Status
SEN_HW_TEMPERATURE / Temperature
SEN_HW_TEMPERATURE / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
Sun Solaris–Environment (prtdiag, lom)
This connector provides environmental information (temperatures, fans, etc.) on several Sun platforms through the prtdiag or lom utility.
Target
Typical platform: Sun Fire (SPARC)
Operating system: Sun Solaris
Instrumentation layer: Sun Solaris system commands (prtdiag, lom, psrinfo, etc.)
Technology used: System commands
Connectors
220
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Fans (SEN_HW_FAN)
Voltage sensors (SEN_HW_VOLTAGE)
Temperature sensors (SEN_HW_TEMPERATURE)
Power supplies (SEN_HW_POWERSUPPLY)
Memory modules (SEN_HW_MEMORY)
Enclosure model (SEN_HW_ENCLOSURE)
Parameters collected
SEN_HW_FAN / Status
SEN_HW_VOLTAGE / Voltage
SEN_HW_VOLTAGE / Status
SEN_HW_TEMPERATURE / Temperature
SEN_HW_TEMPERATURE / Status
SEN_HW_POWERSUPPLY / Status
SEN_HW_MEMORY / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
Credentials required
This connector probably requires root privileges for its proper operation. You therefore will need to configure the product to use the root login/password to execute external commands. Alternatively, you can configure the product to use the 'sudo' utility for the following command: /usr/sbin/lom.
Sun Solaris - Fault Manager (Memory)
This connector parses fmadm faulty command looking for faulty memory modules
Target
Typical platform(s): Sun Fire (SPARC)
Operating system(s): Sun Solaris
Instrumentation layer: Sun Solaris system commands (fmadm)
Technology used: System commands
221
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Memory modules (SEN_HW_MEMORY)
Collected parameters
SEN_HW_MEMORY / Status
SEN_HW_MEMORY / ErrorCount
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
This connector probably requires root privileges for its proper operation. You therefore will need to configure the product to use the root login/password to execute external commands.
Alternatively, you can configure the product to use the 'sudo' utility for the following commands:
* /usr/sbin/fmadm
Sun Solaris–Memory modules
This connector provides memory modules monitoring on Sun Solaris 8 and 9 SPARC systems. Requires root privileges
Target
Typical platform: Sun Fire (SPARC)
Operating system: Sun Solaris
Instrumentation layer: Sun Solaris system commands (cediag, cestat)
Technology used: System commands
Discovered objects
Memory modules (SEN_HW_MEMORY)
Parameters collected
SEN_HW_MEMORY / PredictedFailure
SEN_HW_MEMORY / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
222
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Credentials required
This connector probably requires root privileges for proper operation. You therefore will need to configure the product to use the root login/password to execute external commands.
Alternatively, you can configure the product to use the sudo utility for the command: /opt/SUNWcest/ bin/cediag.
Both ce dia g a nd ce sta t ne e d to be a dde d to the sudoe rs file .
Sun Solaris–Network
This connector provides the monitoring of network cards on all Sun Solaris systems.
Target
Typical platform: Sun Fire (SPARC)
Operating system: Sun Solaris
Instrumentation layer: Sun Solaris system commands (kstat, ndd, ifconfig, etc.)
Technology used: System commands
Discovered objects
Network cards (SEN_HW_NETWORK)
Parameters collected
SEN_HW_NETWORK / Status
SEN_HW_NETWORK / ErrorCount
SEN_HW_NETWORK / LinkStatus
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
Credentials required
This connector probably requires root privileges for its proper operation. You therefore will need to configure the product to use the root login/password to execute external commands. Alternatively, you can configure the product to use the sudo utility for the following commands:
/usr/bin/kstat
/usr/sbin/ndd
223
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Sun Solaris–Non-Sun Disks
This connector provides physical disk information (status and error count) on Sun Solaris platforms through the iostat -En utility. Supports only non-Sun disks in Sun systems. This connector needs to be manually activated and will never be picked up automatically during the platform detection and components discovery.
Target
Typical platform: Sun Fire (SPARC)
Operating system: Sun Solaris
Instrumentation layer: Sun Solaris system commands (iostat, dd)
Technology used: System commands
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Physical disks (SEN_HW_PHYSICALDISK)
Collected parameters
SEN_HW_PHYSICALDISK / ErrorCount
SEN_HW_PHYSICALDISK / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
Credentials required
This connector probably requires root privileges for its proper operation. You therefore will need to configure the product to use the root login/password to execute external commands.
Alternatively, you can configure the product to use the 'sudo' utility for the following command: /usr/bin/ dd.
Sun Solaris–Processors (psrinfo)
This connector discovers and monitors the processor in any Sun SPARC-based Solaris machine through the psrinfo system command.
Target
Typical platform: Sun Fire (SPARC)
224
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Operating system: Sun Solaris
Instrumentation layer: Sun Solaris system commands (psrinfo, etc.)
Technology used: System commands
Discovered objects
Processors (SEN_HW_CPU)
Parameters collected
SEN_HW_CPU / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
Sun Solaris - RAID Disks (Raidctl)
Gives physical disk and array status.
Target
Typical platform(s): All Sun Platforms with Hardware Raid Controllers
Operating system(s): Sun Solaris
Instrumentation layer: Sun Solaris system commands (raidctl)
Technology used: System commands
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Logical disks, RAIDs (SEN_HW_LOGICALDISK)
Physical disks (SEN_HW_PHYSICALDISK)
Collected parameters
SEN_HW_LOGICALDISK / Status
SEN_HW_PHYSICALDISK / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
225
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
This connector probably requires root privileges for its proper operation. You therefore will need to configure the product to use the root login/password to execute external commands. Alternatively, you can configure the product to use the 'sudo' utility for the following commands:* /usr/sbin/raidctl
Sun Solaris - SPARC T1/T2 Processors (psrinfo)
This connector discovers and monitors the processor in any Sun SPARC T1, T2-based Solaris machine
(also called CMT, or CoolThreads systems) through the psrinfo system command.
Target
Typical platform(s): Sun Fire (SPARC T1, T2)
Operating system(s): Sun Solaris
Instrumentation layer: Sun Solaris system commands (psrinfo, etc.)
Technology used: System commands
Discovered objects
Processors (SEN_HW_CPU)
CPU Cores (SEN_HW_CPUCORE)
Collected parameters
SEN_HW_CPUCORE / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
Sun Solaris–Sun Disks
This connector provides physical disk information (status and error count) on Sun Solaris systems through the iostat -En utility. Supports only official Sun disks.
Target
Typical platform: Sun Fire (SPARC)
Operating system: Sun Solaris
Instrumentation layer: Sun Solaris system commands (iostat, dd)
226
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Technology used: System commands
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Physical disks (SEN_HW_PHYSICALDISK)
Parameters collected
SEN_HW_PHYSICALDISK / ErrorCount
SEN_HW_PHYSICALDISK / Status
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
Credentials required
This connector probably requires root privileges for its proper operation. You therefore will need to configure the product to use the root login/password to execute external commands.
Alternatively, you can configure the product to use the sudo utility for the command: /usr/sbin/dd.
Sun Solaris - Tape Drives
Gives physical disk information (status and error count) on Sun Solaris systems through the iostat -En utility. Supports only official Sun disks.
Target
Typical platform(s): Sun Fire (SPARC)
Operating system(s): Sun Solaris
Instrumentation layer: Sun Solaris system commands (iostat, dd)
Technology used: System commands
Discovered objects
Tape drives (SEN_HW_TAPEDRIVE)
Collected parameters
SEN_HW_TAPEDRIVE / ErrorCount
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
227
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
This connector probably requires root privileges for its proper operation. You therefore will need to configure the product to use the root login/password to execute external commands.
Alternatively, you can configure the product to use the 'sudo' utility for the following commands:
* /usr/bin/dd
VMware ESXi
This connector provides hardware monitoring through the VMware ESXi firmware.
Target
Typical platform: VMware ESXi
Operating system: N/A
Instrumentation layer: WBEM
Technology used: WBEM
Discovered objects
Fans (SEN_HW_FAN)
Power supplies (SEN_HW_POWERSUPPLY)
Memory modules (SEN_HW_MEMORY)
Processors (SEN_HW_CPU)
Enclosure model (SEN_HW_ENCLOSURE)
Collected parameters
SEN_HW_FAN / Status
SEN_HW_POWERSUPPLY / Status
SEN_HW_MEMORY / Status
SEN_HW_CPU / Status
SEN_HW_ENCLOSURE / Status
This conne ctor ta rge ts re mote de v ice s only .
228
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
WMI - Battery
This connector provides battery monitoring for Windows computers.
Target
Typical platform(s): Any Windows platform
Operating system(s): Microsoft Windows
Instrumentation layer: WMI
Technology used: WMI
Discovered objects
Batteries (SEN_HW_BATTERY)
Collected parameters
SEN_HW_BATTERY / Status
SEN_HW_BATTERY / Charge
SEN_HW_BATTERY / TimeLeft
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
WMI–Disks
This connector provides monitoring of the S.M.A.R.T.-enabled disks that are directly handled by
Windows (and WBEM through the WMI service). It tries to exclude disks that are actually logical disks exposed by some RAID controllers.
Target
Typical platforms: Dell PowerEdge, Fujitsu-Siemens PRIMERGY, HP ProLiant, IBM xSeries, NEC
Express5800, Sun Fire (x64)
Operating system: Microsoft Windows
Instrumentation layer: WMI
Technology used: WMI
229
Connectors
BMC Performance Manager Express for Hardware
Version 2.7.17
Discovered objects
Disk controllers (SEN_HW_DISKCONTROLLER)
Physical disks (SEN_HW_PHYSICALDISK)
Parameters collected
SEN_HW_PHYSICALDISK / Status
SEN_HW_PHYSICALDISK / PredictedFailure
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
WMI–Network
This connector provides the monitoring of network cards on all Windows-based systems through the
WMI layer (root/WMI namespace).
Target
Typical platforms: Dell PowerEdge, Fujitsu-Siemens PRIMERGY, HP ProLiant, IBM xSeries, NEC
Express5800, Sun Fire (x64)
Operating system: Microsoft Windows
Instrumentation layer: WMI
Technology used: WMI
Discovered objects
Network cards (SEN_HW_NETWORK)
Parameters collected
SEN_HW_NETWORK / Status
SEN_HW_NETWORK / LinkStatus
SEN_HW_NETWORK / ErrorCount
This conne ctor is a ble to monitor the loca l host a nd/or a re mote sy ste m.
230
Connectors
Изтегляне
Реклама