Specifications
Model
Test Volume in cubic feet (liters)
Workspace Dimensions (width x depth x height) inches (cm)
Exterior Dimensions (width x depth x height) inches (cm)
924
0.4 ft
3
934
(11.3)
10 x 10 x 7 in
25 x 25 x 18 cm
17.5 x 18.5 x 11 in
44 x 47 x 28 cm
925
0.78 ft
3
935
(22.1)
14.5 x 11 x 8.5 in
37 x 28 x 22 cm
17.5 x 19 x 19.5 in
44 x 48 x 50 cm
926
0.78 ft
3
936
(50.4)
20 x 14 x 11 in
51 x 36 x 28 cm
35 x 24.5 x 15.5 in
89 x 62 x 39 cm
Temperature Range 924, 925, 926
°F -100 to + 525
°C -73.3 to +274
934, 935, 936
-300 to +392
-184 to +200
2
3
1
Average Heat-up Rate
Temperature Control
2
1
Average Cool-down Rate
/min
1
/min
°F 72
°C 40
°F
°C
46
26
°F ±0.25
°C ±0.14
Watts 500
54
30
±0.25
±0.14
Live Load Capacity
2
Temperature
85
65
2
200
93
2 Heater Capacity in kW
Power Draw in Amps (120V-1ph-60Hz)
3
18
Air Flow
23
Horizontal
50 CFM (24 lps)
Approximate Weight lbs kg
38
17
41
19
32
18
27
15
±0.25
±0.14
700
85
65
2
20
Vertical
150 CFM (71 lps)
58
26
40
22
±0.25
±0.14
200
93
2
24
61
28
20
11
41
23
±0.25
±0.14
1000
85
65
2
20
Horizontal
29
16
±0.25
±0.14
24
175 CFM (82.5 lps)
102
47
200
93
2
108
49
Cooling rates are approximate and represent the average rate achieved over the stated temperature range with an empty chamber. Actual cooling rate achieved may vary depending on the temperature range, the type of cooling, the pressure of the gas, and other factors.
Additionally, all cooling rates stated are for the condition when the controller is not cycling the gas flow. The controller will slow the rate of cooling as the temperature nears set-point, so as to not overshoot the set-point.
At steady state conditions.
A three wire 6 ft (1.8m) power cord is provided (120V single phase)
4
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 8 INTRODUCTION
- 8 230 Volt, 50/60 HZ Operation
- 9 Specifications
- 10 INSTRUCTIONS
- 10 Operator Training Requirements
- 11 Installation
- 13 Installation of Cooling Gas
- 14 Installation of Carbon Dioxide
- 18 Cylinder Installation
- 19 Installation of Liquid Nitrogen
- 21 Liquid Nitrogen Cylinder
- 23 Operating
- 23 Controller Power Up
- 24 Heating Only Operation
- 25 Cooling Operation
- 26 Safety Information
- 26 Performance Characteristics
- 31 THEORY OF OPERATION
- 31 Functional Description
- 33 High Limit Controller
- 34 Watlow EZ-Zone PM Controller
- 35 Digital Communication
- 37 MAINTENANCE
- 39 Preventative Maintenance Schedule
- 40 Test Equipment Required
- 40 Chamber
- 41 Coolant Solenoid Orifice Assembly
- 42 Filter
- 43 Corrective Maintenance
- 45 Service Procedures
- 46 Electronic Control Chassis
- 47 HI-LIMIT Thermoswitch
- 48 APPENDIX
- 48 IEEE 488 Interface Converter Set-up
- 50 IEEE 488 Interface Converter
- 51 Serial Signal Descriptions
- 53 XON/XOFF Protocol
- 53 XON/XOFF Versus RTS/CTS Handshaking
- 54 Sample Program
- 55 Sample Output
- 56 Troubleshooting
- 57 Schematic Diagrams