Legacy Locks and Controllers. Schlage AD-Series PIM400, AD-Series WPR400, AD-Series AD-200, AD-Series AD-300, AD-Series AD-250, Legacy CM993, Legacy KC2-9000, Legacy CM5700, Legacy KC2-5500, AD-Series CT5000
โฆษณา
โฆษณา
Legacy Locks and Controllers
Supported Legacy Locks
KC2
CM
CL
BE367
Supported Controllers
PIM
WRI*
WPR*
WPR2*
WSM*
CT500/1000 Controller
CL Campus Lock Controller
* These devices cannot be configured directly. They are configured through the PIM.
All legacy devices use the serial connection type.
Be sure to change the connection type option when connecting to a
Connection Type on page 15 for more information.
and
Handheld Device on page 11 for more
information.
Program a Lock or Controller
1 Connect the HHD to the lock using the HH-Serial Cable and CIP.
2 Select
Device Options
.
3 Select
Program Lock
.
4 Select the door file that should be associated with the lock.
Î Door files are downloaded to the HHD when synchronized with the access
control software.
5 Select
OK
.
6 Wait for the screen asking for the programming credential. Then present the programming credential to the lock.
Î The lock will flash red and green alternating several times, indicating it has
entered programming mode.
Î Consult the lock user guide that came with your lock for more information
about programming mode.
7 Select
OK
. Lock programming will begin.
Schlage Utility Software User Guide 38